Image not available
Illustrative purposes only
HXS 10-NP/SP3
Current Transducer, HXS Series, PCB, 10A, -30A to 30A, 1 %, Voltage Output, 5 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Voltage; Supply Voltage DC Min:4.75V; Supply Voltage DC Max:5.25V; Current Measuring Range DC:-30A to 30A; Current Measuring Range AC:-30A to 30A; Response Time:3µs; Accuracy %
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: 1%
- Accuracy %: 1%
- Product Range: HXS Series
- Response Time: 3µs
- Primary Current: 10A
- Sensor Mounting: Through Hole
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Voltage
- Supply Voltage Range: 5V
- Supply Voltage DC Max: 5.25V
- Supply Voltage DC Min: 4.75V
- Current Sensor Technology: Open Loop, Hall Effect
- Operating Temperature Max: 85°C
- Operating Temperature Min: -40°C
- Current Measuring Range AC: -30A to 30A
- Current Measuring Range DC: -30A to 30A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 7.73 € |
| Current stock | 200+ |
| Lead time | 30 days |
## **Current Transducer HXS 10-NP/SP3** For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). **==> picture [335 x 245] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---| |@|ce|A)A|BS Ass|All Data are given with a|R|L|= 10 kΩ| |Electrical data| |Lo| |I|PN|Primary nominal current rms|Serial Parallel| |± 10|± 20|A| |I|PM|Primary current, measuring range|Serial Parallel| |± 30|± 60|A| |V|OUT|Analog Output voltage @|I|P|V|OE ±|(0.625.|I|P/|I|PN) V| |G|TH|Theoretical sensitivity|0.625|V|/|I|PN| |V|REF|Reference voltage|[1)]|Ouput voltage|2.5 ± 0.025|V| |Ouput impedance|typ. 200|Ω| |Load impedance|≥ 200|kΩ| |R|L|Load resistance|≥ 2|kΩ| |R|OUT|Output internal resistance|< 5|Ω| |C|L|Capacitive loading (± 20 %)|= 4.7|nF| |V|C|Supply voltage (± 5 %)|[ 2)]|5|V| |I|C|Current consumption @|V|C = 5V|19|mA| **----- End of picture text -----**<br> **==> picture [336 x 336] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||||| |---|---|---|---|---|---|---|---|---|---| |Accuracy - Dynamic performance data| |Lo| |X|Accuracy|[3)]|@|I|PN ,|T|A = 25°C|≤ ± 1|%| |εL|Linearity error|0 ..|I|PN|≤ ± 0.5|%| |0 .. 3 x|I|PN|≤ ± 1|%| |TCV|OE|Temperature coefficient of|V|OE|(+25.. 85°C)|≤ ± 0.4|mV/K| |(-40.. +25°C)|≤ ± 0.525|mV/K| |TCV|REF|Temperature coefficient of|V|REF|(+25.. 85°C)|≤ ± 0.01|%/K| |(-40.. +25°C)|≤ ± 0.015|%/K| |TCV|OE/|V|REFTemperature coefficient of|V|OE /|V|REF|≤ ± 0.15|mV/K| |TCG|Temperature coefficient of|G|≤ ±0.05 % of reading/K| |V|OE|Electrical offset voltage @|I|P = 0,|T|A = 25°C|V|REF ± 0.0125|V| |V|OM|Magnetic offset voltage @|I|P = 0| |after an overload of 3 x|I|PN|± 0.7|%| |t|ra|Reaction time to 10 % of|I|PN step|< 3|µs| |t|r|Response time to 90 % of|I|PN step|< 5|µs| |di/dt|di/dt accurately followed|> 50|A/µs| |V|no|Output voltage noise (DC .. 10 kHz)|< 20|mVpp| |(DC .. 1 MHz)|< 40|mVpp| |BW|Frequency bandwidth (- 3 dB)|[4)]|DC .. 50|kHz| |General data| |Lo| |T|A|Ambient operating temperature|- 40 .. + 85|°C| |T|S|Ambient storage temperature|- 40 .. + 85|°C| |m|Mass|10|g| |Standards|EN 50178: 1997| |Notes:|[1)]|It is possible to overdrive|V|REF with an external reference voltage between| |1.5 - 2.8 V providing its ability to sink or source approximately 5 mA.| **----- End of picture text -----**<br> - [2)] Maximum supply voltage (not operating) < 6.5V ## **I = 10, 20 A** PN ## **DUAL PHASE** ## **Features** - ●Hall effect measuring principle - ●Multirange current transducer through PCB pattern lay-out - ●Galvanic isolation between primary and secondary circuit - ●Isolation test voltage 3500 V between Primary and Secondary - ●Low power consumption - ●Extremely low profile < 11 mm - ●Single power supply + 5 V - ●Fixed offset & sensitivity - ●Isolated plastic case recognized according to UL 94-V0. ## **Special feature** - ●Two separate primary windings for dual phase measurement. ## **Advantages** - ●Small size and space saving - ●Only one design for wide current ratings range - ●High immunity to external interference - ●Internal & external reference. ## **Applications** - ●AC variable speed drives and servo motor drives - ●Static converters for DC motor drives - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power supplies for welding applications. ## **Application domain** - [3)] Excluding Offset and Magnetic offset voltage. > [4)] Small signal only to avoid excessive heatings of the magnetic core ●Industrial. Page 1/3 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 120416/14 ## **Current Transducer HXS 10-NP/SP3** ## **Isolation characteristics** |**V**d|Rms voltage for AC isolation test, 50 Hz, 1 min||| |---|---|---|---| ||Primary to secondary|3.5|kV| ||Primary 1 to primary 2|2.5|kV| |**dCp**|Creepage distance|> 5.5|mm| |**dCI**|Clearance distance|> 5.5|mm| |**CTI**|Comparative Tracking Index (group I)|> 600|V| ## **Applications examples** **According to EN 50178, IEC 61010-1 standards** and following conditions: - ●Over voltage category OV 3 - ●Pollution degree PD2 - ●Non-uniform field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |Single isolation|600 V|600 V| |Reinforced isolation|300 V|150 V| **According to UL508 standard** and following conditions: Max. Voltage 600V - ●Over voltage category OV 3 - ●Pollution degree PD2 ## **Safety** This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 120416/14 ## **Dimensions HXS 10-NP/SP3** (in mm) ## `Required connection circuit` **==> picture [189 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> 5V<br>HXS 10-NP<br>47nF<br>/SP3<br>0V<br>4.7nF<br>Output<br>47nF<br>V Ref. IN/OUT<br>**----- End of picture text -----**<br> **==> picture [378 x 99] intentionally omitted <==** **----- Start of picture text -----**<br> connectionsPrimary nominalPrimary currentmaximum resistancePrimary Primary insertioninductance PCB connectionsRecommended<br>IPN [ A ] IP [ A ] RP [ mΩ ] LP [ µH ]<br>IN 1 7<br>Serial 10 30 0.2 0.1<br>ogfo)<br>2 8 OUT<br>IN 1 7<br>o_o<br>Parallel 20 60 0.05 0.025<br>o———o<br>2 8 OUT<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** - ●General tolerance ± 0.2 mm ●Transducer fastening & connection of primary jumper 4 pins □ 1.2 mm (corner R 0.4mm) ●Transducer fastening & connection of secondary 4 pins 0.5 x 0.25 mm ## **Recommended PCB hole** - ●Primary PCB hole Ø 1.5 mm ●Secondary PCB hole Ø 0.7 mm ## **Remarks** - **V** OUT is positive when **I** P flows from terminals 1, 7 (IN) to terminals 2, 8 (OUT). - ●Temperature of the primary conductor should not exceed 100°C. Page 3/3 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 120416/14
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →