Image not available
Illustrative purposes only
HX 15-P/SP2
Current Transducer, HX Series, 15A, -45A to 45A, 1 %, Voltage Output, 12 Vdc to 15 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Voltage; Supply Voltage DC Min:12V; Supply Voltage DC Max:15V; Current Measuring Range DC:-45A to 45A; Current Measuring Range AC:-45A to 45A; Response Time:3µs; Accuracy %:1%; Product R
- SVHC: No SVHC (17-Jan-2022)
- Accuracy: 1%
- Accuracy %: 1%
- Product Range: HX Series
- Response Time: 3µs
- Sensor Output Type: Voltage
- Supply Voltage DC Max: 15V
- Current Measuring Range AC: -45A to 45A
- Current Measuring Range DC: -45A to 45A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 11.79 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Current Transducer HX 03..50-P/SP2** ## **I = 3 .. 50 A PN** For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). ## **Electrical data** |Primary nominal|Primary current,<br>Primary conductor||**Type**|RoHS since|RoHS since|RoHS since| |---|---|---|---|---|---|---| |current rms|measuring range1)<br>diameter x turns||||date code|| |**I**PN(A)|**I**PM(A)<br>(mm)|||||| |3|± 9<br>0.6d x 20T|**HX 03-P/SP2**||||46128| |5<br>10<br>15|± 15<br>0.8d x 12T<br>± 30<br>1.1d x 6T<br>± 45<br>1.4d x 4T|**HX 05-P/SP2**<br>**HX 10-P/SP2**<br>**HX 15-P/SP2**||||46019<br>45352<br>46133| |20|± 60<br>1.6d x 3T|**HX 20-P/SP2**|||planned|| |25<br>50|± 75<br>1.6d x 2T<br>± 150<br>1.2 x 6.3 x 1T|**HX 25-P/SP2**<br>**HX 50-P/SP2**||||46233<br>46152| |**V**OUT|Output voltage (Analog) @ ±**I**PN,**R**L= 2 kΩ,|,**T**A= 25°C|= 25°C|VOE± 0.625|± 0.625<br>V|| |**R**OUT|Output internal resistance|||< 50||Ω| |**R **L|Load resistance|||≥2||kΩ| |**V**C|Supply voltage (± 5 %)|||+ 12 .. 15<br>V||| |**I **C|Current consumption|||< 15||mA| |**V**d|Rms voltage for AC isolation test, 50 Hz, 1 min|Rms voltage for AC isolation test, 50 Hz, 1 min||> 3||kV| |**V**e|Partial discharge extinction voltage rms @|Partial discharge extinction voltage rms @|10 pC|≥1||kV| |**V**W|Impulse withstand voltage, 1.2/50 µs|||≥6||kV| |**Accuracy-Dynamic performance data**||||||| |**X**|Accuracy @**I**PN,**T**A= 25°C (excluding offset)|||< ± 1||% of**I**PN| |**ε**L|Linearity error (0 .. ±**I**PN)|||< ± 1||% of**I**PN| |**V**OE|Electrical offset voltage @**T**A= 25°C|||+ 2.5V ± 50||+ 2.5V ± 50 mV| |**V**OH|Hysteresis offset voltage @**I**P= 0;<br>after an excursion of 1 x**I**PN|||< ± 10||mV| |**TCV**OE|Temperature coefficient of**V**OE|||< ± 1.5||mV/K| |**TCV**OUT|Temperature coefficient of**V**OUT(% of reading)|||± 0.1||%/K| |**t **r<br>**BW**|Response time to 90% of**I**PNstep<br>Frequency bandwidth (- 3 dB)2)|||≤3<br>50 kHz|50 kHz|µs<br>50 kHz| |**General data**|**General data**|||||| |**T**A|Ambient operating temperature|||- 25 .. + 85<br>°C||| |**T**S|Ambient storage temperature|||- 25 .. + 85<br>°C||| |**_m_**|Mass|||8||g| |**dCp**|Creepage distance|||≥5.5||m m| ||Isolation material group|||I||| ||Standards|||EN50178: 1997||| ## **Features** - Galvanic isolation between primary and secondary circuit - Hall effect measuring principle - Isolation voltage 3000V - Low power consumption - Extended measuring range(3x **I** PN) - Isolated plastic case recognized according to UL94-V0. ## **Special feature** - Single supply from +12V to +15V ## **Advantages** - Low insertion losses - Easy to mount with automatic handling system - Small size and space saving - Only one design for wide current ratings range - High immunity to external interference. ## **Applications** - Switched Mode Power Supplies (SMPS) - AC variable speed drives - Uninterruptible Power Supplies (UPS) - Electrical appliances - Battery supplied applications - DC motor drives ## **Application domain** - Industrial Notes :[ 1)] With **R** L=2kΩ - 2) Small signal only to avoid excessive heating of the magnetic core Page 1/2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 070313/6 www.lem.com ## **Dimensions HX 03..50-P/SP2** (in mm. 1 mm = 0.0394 inch) **==> picture [479 x 368] intentionally omitted <==** **----- Start of picture text -----**<br> HX 03..25-P/SP2 HX 03...25-PHX 02..25-P HX 50-PHX 50-P/SP2 HX 50-P<br>19 Max. 19 Max.<br>Terminal Pin Identification<br>1 ..... 0V<br>2 ..... 0V<br>3 ..... +12V to +15V<br>4 ..... Output<br>5 ..... Primary input Current (+)<br>6 ..... Primary input Current (-)<br>3 10.85 3 8.8 5.4<br>Primary conductor diameter<br>d<br>Bottom view Bottom view 03-P/ 05-P/ 10-P/ 15-P/<br>HX<br>SP2 SP2 SP2 SP2<br>4 OUT 6 4 OUT 6 5 d 0.6 0.8 1.1 1.4<br>3 +V 3 +V 20-P/ 25-P/ 50-P/<br>HX<br>2 0 2 0 SP2 SP2 SP2<br>1 -V or 0 5 1 -V or 0 d 1.6 1.6 1.2 x 6.3<br>1.2<br>3 10.85 3 8.8 5.4<br>Secondary pins dimension<br>0.5 x 0.25<br>Top view<br>HX 0HX 0 5-P /<br>SP2<br>41123<br>Lot No.<br>20Max. 20Max.<br>0.5 0.5<br>3.5 3.5 3.5 3<br>6 5<br>3-P=2.54 15.4 Max. 3-P=2.54 15.4 Max.<br>1.3<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** ## **Safety** • General tolerance ± 0.5 mm This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/2 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 070313/6 www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →