HWS3000GT-60
POWER SUPPLY, AC-DC, 60V, 50A, 3KW
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Power Supply Applications:ITE, Industrial, LED Lighting; No. of Outputs:1Outputs; Output Power Max:3kW; Output Voltage - Output 1:60V; Output Current - Output 1:50A 13AM5664
- SVHC: No SVHC (15-Jan-2018)
- Product Range: HWS3000GT Series
- No. of Outputs: 1Outputs
- Output Power Max: 3kW
- Current, Output 4: -
- Input Voltage VAC: 170V AC to 265V AC
- Power Supply Output Type: Programmable
- Output Current - Output 1: 50A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 60V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial, LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 1220.61 € |
| Current stock | 10+ |
| Lead time | 30 days |
HWS3000GT Series Three phase input 3,000W Programmable CVCC AC-DC Power Supplies https://product.tdk.com/en/power/hws-g www.emea.lambda.tdk.com/hws-g The compact HWS3000GT AC-DC power supplies can deliver 3,000W with a 3-three phase input voltage of 170 - 265Vac. The nominal output voltages (24V, 48V, 60V, 80V, 130V or 250V) and output current are fully programmable from zero up to their maximum rating. This can be achieved using a serial RS485 interface (MODBus protocol) or analog 1-5V or 4-20mA signal. Up to three units can be connected in series and / or ten units in parallel. The HWS3000GT is packaged in a compact 270 x 150 x 61mm (10.6 x 5.9 x 2.4”) footprint and has conservatively rated electrolytic capacitor temperatures for long field life. The /HD option code includes dual sided board coating and designed to meet shock and vibration for MIL-STD-810G. The warranty period is seven years[(1)] . |**Features**|**Benefits**| |---|---| |• Serial or Analog Programming (CV/CC)|• Choice of Programming Interfaces| |• Series and/or Parallel Operation|• Scalable Voltage and Current| |• Compact 270 x 150 x 61mm (10.6 x 5.9 x 2.4”) Footprint|• Space Saving in End Equipment| |• Single and Three Phase Models (See Related Products)|• Global Use| |• Seven Year Warranty(1)|• Low Cost of Ownership| |• Optional Board Coating & Ruggedization|• Designed to meet MIL-STD-810G (Shock and Vibration) (HD Option Code)| ## **Model Selector** |Model||Nominal Output<br>Voltage|Nominal Output<br>Voltage|Output Adjustment<br>(Potentiometer)|Output Adjustment<br>(Potentiometer)|Output Adjustment<br>(Potentiometer)|Output Adjustment<br>Output Adustment<br>(Programming)|Output Adjustment<br>Output Adustment<br>(Programming)|Output Adustment|Output Current (A)<br>(3-phase 170 - 265Vac Input) (3-phase 170 - 265Vac Input) (220 / 230Vac)|Output Current (A)<br>(3-phase 170 - 265Vac Input) (3-phase 170 - 265Vac Input) (220 / 230Vac)|Output Current (A)<br>(3-phase 170 - 265Vac Input) (3-phase 170 - 265Vac Input) (220 / 230Vac)|Output Current (A)<br>(3-phase 170 - 265Vac Input) (3-phase 170 - 265Vac Input) (220 / 230Vac)|Max Power<br>(3-phase 170 - 265Vac Input) (3-phase 170 - 265Vac Input) (220 / 230Vac)|Max Power<br>(3-phase 170 - 265Vac Input) (3-phase 170 - 265Vac Input) (220 / 230Vac)|Max Power<br>(3-phase 170 - 265Vac Input) (3-phase 170 - 265Vac Input) (220 / 230Vac)|Max Power<br>Efficiency<br>(3-phase 170 - 265Vac Input) (3-phase 170 - 265Vac Input) (220 / 230Vac)|Max Power<br>Efficiency<br>(3-phase 170 - 265Vac Input) (3-phase 170 - 265Vac Input) (220 / 230Vac)|Max Power<br>Efficiency<br>(3-phase 170 - 265Vac Input) (3-phase 170 - 265Vac Input) (220 / 230Vac)| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||(V)|||(V)||(V)|(V)||||(Programming)||||(W)||(%)|| |HWS3000GT-24||24||19.2 - 28.8|||0 - 28.8||||||0 - 125|||3000||91|| |HWS3000GT-48||48||38.4 - 52.8|||0 - 52.8||||||0 - 62.6|||3004.8||92|| |HWS3000GT-60||60||48.0 - 66.0|||0 - 66.0||||||0 - 50|||3000||92|| |HWS3000GT-80||80||64.0 - 96.0|||0 - 96.0||||||0 - 37.5|||3000||92|| |HWS3000GT-130||130||104.0 - 156.0|||0 - 156.0||||||0 - 23.2|||3016||93|| |HWS3000GT-250||250||200.0 - 300.0|||0 - 300.0||||||0 - 12.0|||3000||93|| ||||||||||||||||||||| |**HWS3000GT**||||**-**|**-**||**24**|||||**/**|**/**|||**HD**|||| ||||||||||||||||||||| |Series|||||||Output voltage|Output voltage|||||||Blank No Options|Blank No Options|||| ||||||||24, 48, 60, 80, 130, 250||24, 48, 60, 80, 130, 250||||Option Code||HD<br>RF|Board coating + MIL-STD-810<br>Reverse Fan (Intake Airflow)|||| ||||||||||||||||||||| |**Related Products**|||||||||||||||||||| |Type|||||Part Number(s)|||||||||Description|||||| |EMC filter|||||RTMN-5020||||||||High attenuation 20A 500Vac two stage filter||||||| |3kW Programmable Power Supplies|||||HWS3000G||||||||Single phase 85 - 265Vac input|||Single phase 85 - 265Vac input|||| |100-800W Programmable Power Supplies|||||Z+ Low Voltage||||||||Z+ 10V to 100V Programmable Power Supplies||||||| |100-800W Programmable Power Supplies|||||Z+ High Voltage||||||||Z+ 160V to 650V Programmable Power Supplies||||||| HWS3000GT Series 1 **==> picture [517 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---|---|---|---|---| |Model<br>HWS3000GT-24|||HWS3000GT-48|HWS3000GT-80|HWS3000GT-130|HWS3000GT-250| |**Input**||||||| |Input Voltage Range (Operating)|Vac|3-phase 170- 265<br>||||| |Nominal Input Voltage Range|Vac|3-phase 200 - 240 (Note: Safety certifed for 180 - 264Vac only)<br>||||| |Input Frequency|Hz|47 - 63 (Note: Safety certifed for 50-60Hz)||||| |Input Current at 200 / 230Vac|A|10|9.9|9.9|9.9|9.9| |Inrush Current at 200Vac (Cold Start)|A|80 (at 2nd Inrush)||||| |Leakage Current|mA|<3 at 240Vac 60Hz||||| |Power Factor (200Vac)|-|0.95||||| |Harmonic Compliance|-|Meets IEC61000-3-2||||| |No Load Power Consumption|W|See evaluation data on website||||| |Hold Up Time (typ<br>|ms|20 at 1500W load, 10 at 3000W||||| |Effciency|-|See model selector||||| |Conducted & Radiated EMI|-|EN55032A, EN55011-A, FCC-A||||| |Immunity|-|IEC61000-6-2, IEC61000-4.2, -3, -4, -5, -6, -8, -11||||| |Insulation Class<br>|-|Class I||||| |Safety Certifcations and Markings|-|IEC/EN/UL/CSA62368-1, IEC/EN62477-1 (OVC III, 2,000m altitude). CE Mark and UKCA Mark||||| ## **Immunity** |**Immunity**|**Immunity**|**Immunity**|**Immunity**|**Immunity**| |---|---|---|---|---| |Test<br>ESD|Standard<br>EN61000-4-2|Test Level<br>Contact Discharge: 1, 2<br>Air Discharge: 1, 2, 3|Criteria<br>B<br>B|Notes<br>-<br>-| |Radiated Susceptibility|EN61000-4-3|2<br>3|A<br>A|1.4 - 6.0GHz<br>80 - 1000MHz| |Electrical Fast Transient Burst|EN61000-4-4|1, 2, 3|B|-| |Surge|EN61000-4-5|1, 2, 3<br>1, 2|B<br>B|Common mode<br>Normal mode| |Conducted Susceptibility<br>|EN61000-4-6|1, 2, 3|A|| |Magnetic felds|EN61000-4-8|1, 2, 3, 4|A|| |Voltage Dips and Input Interruptions|EN61000-4-11|30% 500ms|A|L1 - L2, L2 - L3, L3 - L1| |||60% 200ms|A|L1 - L2, L2 - L3, L3 - L1| |||100% 20ms|A|L1 - L2, L2 - L3, L3 - L1| |||100% 5000ms|C<br>C<br>A|L1 - L2<br>L2 - L3<br>L3 - L1| |SEMI F47 Line Dip|SEMI F47|-|-|At input voltages > 200Vac| HWS3000GT Series 2 **==> picture [516 x 34] intentionally omitted <==** |**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**|**Specifcations**| |---|---|---|---|---|---| |Model<br>HWS3000GT-24|||HWS3000GT-48|HWS3000GT-60|HWS3000GT-130| |**Output**|||||| |Switching Frequency|kHz|Primary: 120, secondary: 240|||| |Line Regulation|mV|24V: 96, 48V: 192, 60V: 240, 80V: 320, 130V: 520, 250V: 1000|||| |Load Regulation|mV|24V: 192, 48V: 384, 60V: 480, 80V: 640, 130V: 1040, 250V: 2000|||| |Ripple & Noise|mV|24V: 300, 48V: 400, 60V: 500, 80V: 600 130V: 866, 250V: 1250|||| |Standby Voltage|-|5V 2A|||| |Series Operation|-|See Instruction Manual|||| |Parallel Operation|-|Up to ten units, see the Instruction Manual|||| |External Load Capacitance<br>|uF|Not applicable|||| |Temperature Coeffcient|%/°C|±0.02|||| |Minimum Load|-|No minimum load required|||| |Overcurrent Protection(2)|A|24V: 131.2<, 48V: 65.7<, 60V: 52.5<, 80V: 39.3 <, 130V: 24.3<, 250V: 12.6 <|||| |Overvoltage Protection|V|24V: 30.4 - 31.5, 48V: 56.1 - 58.1, 60V: 70.2 - 72.6, 80V: 101.6 -104.8, 130V: 165.1 - 170.3, 250V: 317.5 - 327.5|||| |Remote Sense|-|0.3V compensation|||| |Remote On/Off|-|Yes, see Instruction Manual|||| |Signals|-|AC Fail, Voltage and Current Good, Fan Fail (Open collector)|||| |**Output (Constant Current Mode)**|||||| |Line Regulation|mA|24V: 500, 48V: 250.4, 60V: 200, 80V: 150, 130V: 92.8, 250V: 48|||| |Load Regulation|mA|24V: 1000, 48V: 500.8, 60V: 400, 80V: 300 130V: 185.6, 250V: 96|||| |**Programing and monitoring**|||||| |Communication Interface|-|Modbus RTU (RS-485): Controls output voltage and current, product status (including product life)<br>Operational history - OCP, OVP, AC Fail, etc.|||| |Output Voltage Monitor using VB terminal|-|Output Voltage : 0% - Nominal output voltage, VB terminal voltage : 1 - 5V|||| |Output Current Monitor using CB terminal|-|Output Current : 0% - Maximum, CB terminal voltage : 1 - 5V|||| |Output Voltage Ext. Control Using CV Terminal|-|Apply external voltage or current : 1 - 5V or 4 - 20mA, Output Voltage: 0% - Nominal output voltage|||| |Output Current Ext. Control Using CC Terminal|-|Apply external voltage or current (1 - 5V or 4 - 20mA). Output Current: 0% - Max.|||| |Output Voltage Ext. Control Using Modbus RTU|-|0 - 4,000. Output Voltage: 0% - Nominal output voltage|||| |Output Current Ext. Control Using Modbus RTU|-|0 - 4,000. Output Current: 0% - Max.|||| |**Environmental**|||||| |Operating Temperature (-40°C start-up)|°C|-20 to +70, derate output current linearly to 50% load from 50 to 70|||| |Storage Temperature|°C|-40 to +85|||| |Humidity (non condensing)|%RH|Operating: 20 - 90, Storage: 10 - 95|||| |Cooling|-|Variable speed fan, air exits across rear. Fan noise is 45dB (typ) at 25°C and 70% load|||| |Altitude|m|5,000. Operating, transportation and storage. IEC/EN62477-1 (OVC III, 2,000m altitude)|||| |Withstand Voltage (For 1 minute)|Vac|Input to Ground 2,000, Input to Output 3,000, Output to Ground 1,500|||| |Isolation Resistance|MΩ|>100 at 25°C, 70%RH & 500Vdc|||| |Vibration (Non Operating)|-|10-55Hz (1 min sweep). Maximum 19.6m/s2, 1 hour each|||| |Shock|-|<196m/s2|||| |**Other**|||||| |Weight (Typ)|g|2,300|||| |Size (LxWxH)|mm|270 x 150 x 61|||| |Size (LxWxH)|Inches|10.63 x 5.91 x 2.4<br>|||| |Connectors|-|Input/Output: Screw terminals, Output connector is user confgurable for vertical or horizontal orientation|||| |MTBF - Telcordia SR-332*|-|25°C: 825,678, 40°C: 527,785|||| |Warranty|yrs|7(1)|||| Notes: See website for detailed specifications, test methods and Instruction Manual. Specification parameters apply at 25°C ambient temperature unless otherwise stated. (1) The Americas and EMEA regions: 7 years. Other regions: 5 years. See applicable regional terms of sale. (2) Constant current with automatic recovery. If the overload lasts more than 30s, the output will shutdown *24V 125A, 230Vac input Link to GUI Link to Communication manual HWS3000GT Series 3 ## **Outline Drawing** HWS3000GT Series 4 ## **TDK-Lambda France SAS** Tel: +33 1 60 12 71 65 tlf.fr-powersolutions@tdk.com www.emea.lambda.tdk.com/fr ## **Italy Sales Office** Tel +39 02 61 29 38 63 tlf.it-powersolutions@tdk.com www.emea.lambda.tdk.com/it ## **Netherlands** tlf.nl-powersolutions@tdk.com www.emea.lambda.tdk.com/nl ## **TDK-Lambda Europe GmbH** Tel: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de ## **Austria Sales Office** Tel: +43 2256 655 84 tlg.at-powersolutions@tdk.com www.emea.lambda.tdk.com/at ## **Switzerland Sales Office** Tel: +41 44 850 53 53 tlg.ch-powersolutions@tdk.com www.emea.lambda.tdk.com/ch ## **TDK-Lambda Americas** Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com ## **TDK Electronics do Brasil Ltda** Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en ## **TDK-Lambda Corporation** Tel: +81-3-6778-1113 www.jp.lambda.tdk.com ## **TDK-Lambda (China) Electronics Co. Ltd.** Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn ## **TDK-Lambda Singapore Pte Ltd.** Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com ## **TDK India Private Limited, Power Supply Division** Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com ## **TDK-Lambda Europe GmbH** Tel: Tel. +45 3222 8086 tlg.dk-powersolutions@tdk.com www.emea.lambda.tdk.com/dk ## **TDK-Lambda UK Ltd.** Tel: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk ## **TDK-Lambda Ltd.** Tel: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en For Additional Information, please visit ~~a~~ https://product.tdk.com/en/power/ HWS3000GT_Datasheet_360185 V7, May 18th, 2026 HWS3000GT Series 5
Updated at June 4, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →