HVGC-150-1050A
LED Driver, IO Adj W/ POT, LED Lighting, 150.15 W, 143 V, 1.05 A, Constant Current, 180 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HVGC-150 Series
- Output Current: 1.05A
- LED Driver Mode: Constant Current
- Output Power Max: 150.15W
- Input Voltage Max: 528V
- Input Voltage Min: 180V
- Output Voltage Max: 143V
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 69.05 € |
| Current stock | 10+ |
| Lead time | 30 days |
**HVGC - 150 series** 150W Constant Current Mode LED Driver **==> picture [42 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g ~~2~~ **www.ID 2000000000tuv.com** FECBCELE CP Hl W **** ~~w~~ ## ** ** ~~(CD~~ \/ \7 \7 ## ** IP65 IP67** ## ■ **** ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧Ⅰ - ‧ - ‧ - ‧ - ‧Ⅰ - ‧ - - ‧ ## ■ **** - ‧ - ‧ ## ■ **** ~ ℃℃ ■ **** ** ** ~~TL~~ ||||| |---|---|---|---| |A|||| ||||| |||<br>|| |D|||| _File Name:HVGC-150-SPEC 2022-02-18_ **HVGC - 150 series** 150W Constant Current Mode LED Driver ## **SPECIFICATION** ||**MODEL**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**CURRENT ADJ. RANGE**<br>**SET UP TIME Note.4**<br>**VOLTAGE RANGENote.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>500ms / 230Vac 400ms / 347VAC,480VAC<br>47 ~ 63Hz<br>0.5A / 347VAC 0.38A / 480VAC<br><0.75mA / 480VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 60℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>1755.7K hrs min. Telcordia SR-332 (Bellcore) ; 179.5K hrs min. MIL-HDBK-217F (25℃)<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level (surge immunity Line-Earth 4KV,<br>Line-Line 2KV), EAC TP TC 020<br>245*68*38.8mm (L*W*H)<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>430 ~ 460V<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>Shut down o/p voltage with auto-recovery or re-power on to recovery<br>**SHORT CIRCUIT**<br>91%<br>**HVGC-150-350**<br>**HVGC-150-1050**<br>**HVGC-150-1400**<br>**HVGC-150-700**<br>**HVGC-150-500**<br>UL8750(type”HL”), CSA C22.2 No. 250.0-08, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, EAC TP TC 004 IP65 or IP67 approved<br>,<br>Constant current limiting, recovers automatically after fault condition is removed<br>210 ~ 350mA<br>630 ~ 1050mA<br>840 ~ 1400mA<br>420 ~ 700mA<br>300 ~ 500mA<br>350mA<br>149.8W<br>42 ~ 428V<br>1.24Kg; 12pcs/15.9Kg/0.78CUFT<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>90%<br>90%<br>91%<br>91%<br>151 ~ 165V<br>113 ~ 124V<br>226 ~ 247V<br>316 ~ 346V<br>1050mA<br>1400mA<br>700mA<br>500mA<br>150.15W<br>149.8W<br>150.5W<br>150W<br>15 ~ 143V<br>12 ~ 107V<br>21 ~ 215V<br>30 ~ 300V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (<br>≧50%) ; BS EN/EN61000-3-3, FCC part 15 class B,<br>@ load<br>EAC TP TC 020<br>COLD START 35A(twidth=790 s measured at 50% Ipeak) at 480VAC;<br> Per NEMA 410<br>μ<br>**TOTAL HARMONIC DISTORTION**<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 480VAC<br>**CONSTANT CURRENT REGIONNote.2**<br>**CURRENT TOLERANCE**<br>±5.0%<br>180 ~ 528VAC 254VDC ~ 747VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>PF<br>0.9 /230VAC, PF<br>0.9 /277VAC<br>full load<br>≧<br>8<br>≧<br>7<br>, PF≧0.95/347VAC, PF≧0.93/480VAC @<br>(Please refer to "<br>"<br>)<br>POWER FACTOR (PF) CHARACTERISTIC section<br>THD< 20%(@ load≧50%/230VAC, 277VAC, 347VAC; @ load≧75%/480VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)<br>Tcase=-40 ~ +80℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>**MAX. CASE TEMP.**<br>Tcase=+80℃<br>℃<br><br><br><br><br><br><br><br><br>℃<br>http://www.meanwell.com.<br>℃℃<br><br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>**CURRENT RIPPLENote.5**<br>8.0% max. @rated current|**MODEL**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**CURRENT ADJ. RANGE**<br>**SET UP TIME Note.4**<br>**VOLTAGE RANGENote.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>500ms / 230Vac 400ms / 347VAC,480VAC<br>47 ~ 63Hz<br>0.5A / 347VAC 0.38A / 480VAC<br><0.75mA / 480VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 60℃)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>1755.7K hrs min. Telcordia SR-332 (Bellcore) ; 179.5K hrs min. MIL-HDBK-217F (25℃)<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level (surge immunity Line-Earth 4KV,<br>Line-Line 2KV), EAC TP TC 020<br>245*68*38.8mm (L*W*H)<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>430 ~ 460V<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>Shut down o/p voltage with auto-recovery or re-power on to recovery<br>**SHORT CIRCUIT**<br>91%<br>**HVGC-150-350**<br>**HVGC-150-1050**<br>**HVGC-150-1400**<br>**HVGC-150-700**<br>**HVGC-150-500**<br>UL8750(type”HL”), CSA C22.2 No. 250.0-08, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, EAC TP TC 004 IP65 or IP67 approved<br>,<br>Constant current limiting, recovers automatically after fault condition is removed<br>210 ~ 350mA<br>630 ~ 1050mA<br>840 ~ 1400mA<br>420 ~ 700mA<br>300 ~ 500mA<br>350mA<br>149.8W<br>42 ~ 428V<br>1.24Kg; 12pcs/15.9Kg/0.78CUFT<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>90%<br>90%<br>91%<br>91%<br>151 ~ 165V<br>113 ~ 124V<br>226 ~ 247V<br>316 ~ 346V<br>1050mA<br>1400mA<br>700mA<br>500mA<br>150.15W<br>149.8W<br>150.5W<br>150W<br>15 ~ 143V<br>12 ~ 107V<br>21 ~ 215V<br>30 ~ 300V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (<br>≧50%) ; BS EN/EN61000-3-3, FCC part 15 class B,<br>@ load<br>EAC TP TC 020<br>COLD START 35A(twidth=790 s measured at 50% Ipeak) at 480VAC;<br> Per NEMA 410<br>μ<br>**TOTAL HARMONIC DISTORTION**<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 480VAC<br>**CONSTANT CURRENT REGIONNote.2**<br>**CURRENT TOLERANCE**<br>±5.0%<br>180 ~ 528VAC 254VDC ~ 747VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>PF<br>0.9 /230VAC, PF<br>0.9 /277VAC<br>full load<br>≧<br>8<br>≧<br>7<br>, PF≧0.95/347VAC, PF≧0.93/480VAC @<br>(Please refer to "<br>"<br>)<br>POWER FACTOR (PF) CHARACTERISTIC section<br>THD< 20%(@ load≧50%/230VAC, 277VAC, 347VAC; @ load≧75%/480VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)<br>Tcase=-40 ~ +80℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>**MAX. CASE TEMP.**<br>Tcase=+80℃<br>℃<br><br><br><br><br><br><br><br><br>℃<br>http://www.meanwell.com.<br>℃℃<br><br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx<br>**CURRENT RIPPLENote.5**<br>8.0% max. @rated current|**HVGC-150-350**|**HVGC-150-500**|**HVGC-150-700**|**HVGC-150-1050**|**HVGC-150-1400**| |---|---|---|---|---|---|---|---| |||**RATED CURRENT**|350mA|500mA|700mA|1050mA|1400mA| |||**RATED POWER**|149.8W|150W|150.5W|150.15W|149.8W| |||**CONSTANT CURRENT REGIONNote.2**|42 ~ 428V|30 ~ 300V|21 ~ 215V|15 ~ 143V|12 ~ 107V| |||**CURRENT ADJ. RANGE**|Adjustable for A/AB-Type only (via built-in potentiometer)<br>210 ~ 350mA<br>630 ~ 1050mA<br>840 ~ 1400mA<br>420 ~ 700mA<br>300 ~ 500mA||||| |||**CURRENT RIPPLENote.5**|8.0% max. @rated current||||| |||**CURRENT TOLERANCE**|±5.0%||||| |||**SET UP TIME Note.4**|500ms / 230Vac 400ms / 347VAC,480VAC||||| |||**VOLTAGE RANGENote.3**|180 ~ 528VAC 254VDC ~ 747VDC<br>(Please refer to "STATIC CHARACTERISTIC" section)||||| |||**FREQUENCY RANGE**|47 ~ 63Hz||||| |||**POWER FACTOR (Typ.)**|PF<br>0.9 /230VAC, PF<br>0.9 /277VAC<br>full load<br>≧<br>8<br>≧<br>7<br>, PF≧0.95/347VAC, PF≧0.93/480VAC @<br>(Please refer to "<br>"<br>)<br>POWER FACTOR (PF) CHARACTERISTIC section||||| |||**TOTAL HARMONIC DISTORTION**|THD< 20%(@ load≧50%/230VAC, 277VAC, 347VAC; @ load≧75%/480VAC)<br>(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)||||| |||**EFFICIENCY (Typ.)**|91%|91%|91%|90%|90%| |||**AC CURRENT (Typ.)**|0.5A / 347VAC 0.38A / 480VAC||||| |||**INRUSH CURRENT (Typ.)**|COLD START 35A(twidth=790 s measured at 50% Ipeak) at 480VAC;<br> Per NEMA 410<br>μ||||| |||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 480VAC||||| |||**LEAKAGE CURRENT**|<0.75mA / 480VAC||||| |||**SHORT CIRCUIT**|Constant current limiting, recovers automatically after fault condition is removed||||| |||**OVER VOLTAGE**|430 ~ 460V<br>Shut down o/p voltage with auto-recovery or re-power on to recovery<br>151 ~ 165V<br>113 ~ 124V<br>226 ~ 247V<br>316 ~ 346V||||| |||**OVER TEMPERATURE**|Shut down o/p voltage, recovers automatically after temperature goes down||||| |||**WORKING TEMP.**|Tcase=-40 ~ +80℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)||||| |||**MAX. CASE TEMP.**|Tcase=+80℃||||| |||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing||||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +80℃, 10 ~ 95% RH||||| |||**TEMP. COEFFICIENT**|±0.03%/℃(0 ~ 60℃)||||| |||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes||||| |||**SAFETY STANDARDS**|UL8750(type”HL”), CSA C22.2 No. 250.0-08, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, EAC TP TC 004 IP65 or IP67 approved<br>,||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC||||| |||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH||||| |||**EMC EMISSION**|Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (<br>≧50%) ; BS EN/EN61000-3-3, FCC part 15 class B,<br>@ load<br>EAC TP TC 020||||| |||**EMC IMMUNITY**|Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level (surge immunity Line-Earth 4KV,<br>Line-Line 2KV), EAC TP TC 020||||| |||**MTBF**|1755.7K hrs min. Telcordia SR-332 (Bellcore) ; 179.5K hrs min. MIL-HDBK-217F (25℃)||||| |||**DIMENSION**|245*68*38.8mm (L*W*H)||||| |||**PACKING**|1.24Kg; 12pcs/15.9Kg/0.78CUFT||||| |||℃<br><br><br><br><br><br><br><br><br>℃<br>http://www.meanwell.com.<br>℃℃<br><br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>※ : , https://www.meanwell.com/serviceDisclaimer.aspx|||||| _File Name:HVGC-150-SPEC 2022-02-18_ **HVGC - 150 series** ## 150W Constant Current Mode LED Driver ## **Block Diagram** **==> picture [472 x 427] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 130KHz<br>PWM fosc : 70KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.L.P. DIM+<br>DIM-<br>(B Type)<br>DETECTION<br>FG O.L.P.<br>PWM & PFC CIRCUIT<br>PFC CONTROL<br>CONTROL<br>O.T.P. O.V.P.<br>DRIVING METHODS OF LED MODULE<br>※ This series works in constant current mode to directly drive the LEDs.<br>In the constant current region, the highest voltage at the output of the driver<br>100<br>depends on the configuration of the end systems.<br>Should there be any compatibility issues, please contact MEAN WELL.<br>Constant<br>Current region<br>50 100 Io (%)<br>Typical output current normalized by rated current (%)<br>Vo(%)<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** _File Name:HVGC-150-SPEC 2022-02-18_ **HVGC - 150 series** 150W Constant Current Mode LED Driver ## **DIMMING OPERATION** **==> picture [501 x 63] intentionally omitted <==** **----- Start of picture text -----**<br> FG (Green/Yellow) DIM+(Purple)DIM-(Pink)<br>AC/L(Brown) HVGC-150<br>AC/N(Blue) -V(Black)<br>+V(Red)<br>**----- End of picture text -----**<br> ## ※ **3 in 1 dimming function (for B/AB-Type)** - ‧Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: - 0 ~ 10VDC, or 10V PWM signal or resistance. - ‧Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. - ‧Dimming source current from power supply: 100μA (typ.) ◎ Applying additive 0 ~ 10VDC **==> picture [215 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>+V +<br>-<br>-V -<br>DIM+<br>+<br>Additive Voltage<br>-<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> - Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): **==> picture [215 x 247] intentionally omitted <==** **----- Start of picture text -----**<br> +<br>+V +<br>-<br>-V -<br>DIM+<br>Additive PWM signal<br>DIM-<br>“DO NOT connect "DIM- to -V"<br> Applying additive resistance:<br>+<br>+V +<br>-<br>-V -<br>DIM+<br>Additive Resistance<br>DIM-<br>“DO NOT connect "DIM- to -V"<br>**----- End of picture text -----**<br> - Applying additive resistance: **==> picture [157 x 469] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>100%<br>90%<br>80%<br>70%<br>60%<br>50%<br>40%<br>30%<br>20%<br>10%<br>0%<br>Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> Note : 1. Min. dimming level is about 6% and the output current is not defined when 0%< Iout<6%. 2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle. _File Name:HVGC-150-SPEC 2022-02-18_ **HVGC - 150 series** 150W Constant Current Mode LED Driver ## **OUTPUT LOAD vs TEMPERATURE(Note.9)** **==> picture [495 x 597] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>60 60<br>40 40<br>20 20<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -25 0 20 45 55 65 75 80 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( � ) Tcase ( � )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 70�<br>1<br>100 0.98<br>0.96<br>90<br>0.94<br>80 0.92 480V<br>0.9<br>70 0.88 347V<br>0.86 277V<br>60 0.84 230V<br>50 0.82<br>0.8<br>40 0.78<br>50% 60% 70% 80% 90% 100%<br>180 200 347 440 480 528 (150W)<br>LOAD<br>INPUT VOLTAGE (V) 60Hz<br>※ De-rating is needed under low input voltage.<br>TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD<br>HVGC-150 series possess superior working efficiency that up to 91% can<br>※ 350mA Model, Tcase at 70� be reached in field applications.<br>※ 350mA Model, Tcase at 70�<br>18<br>95<br>16<br>14 90<br>12<br>85<br>480V<br>10 480VAC<br>80 347V<br>8 347VAC<br>277V<br>6 277VAC 75<br>230V<br>4 230VAC<br>70<br>2<br>0 65<br>50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>LOAD<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>THD(%)<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:HVGC-150-SPEC 2022-02-18_ **HVGC - 150 series** 150W Constant Current Mode LED Driver ## **LIFE TIME** **==> picture [309 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>20 30 40 50 60 70 80<br>Tcase�(℃ )<br>LIFETIME(Kh)<br>**----- End of picture text -----**<br> _File Name:HVGC-150-SPEC 2022-02-18_ **HVGC - 150 series** 150W Constant Current Mode LED Driver **==> picture [501 x 556] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No. 994 Unit:mm<br>※ A-Type<br>245<br>12 221<br>9.6<br>Io<br>300±20 ADJ. 300±20<br>FG (Green/Yellow) 106.9 -V(Black)<br>AC/L(Brown) tc +V(Red)<br>AC/N(Blue) STW 18AWG×3C STW 18AWG×2C<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ B-Type<br>245<br>12 221<br>9.6<br>300±20<br>300±20<br>DIM+(Purple)<br>FG AC/L(Brown) (Green/Yellow) tc 106.9 UL2517 18AWG×2C DIM-(Pink)<br>AC/N(Blue) STW 18AWG×3C -V(Black)<br>+V(Red)<br>STW 18AWG×2C<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>**----- End of picture text -----**<br> _File Name:HVGC-150-SPEC 2022-02-18_ **HVGC - 150 series** 150W Constant Current Mode LED Driver **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※ AB-Type<br>245<br>12 221<br>9.6<br>300±20<br>Io<br>300±20 ADJ. DIM+(Purple)<br>FG AC/L(Brown) (Green/Yellow) tc 106.9 UL2517 18AWG×2C DIM-(Pink)<br>AC/N(Blue) STW 18AWG×3C -V(Black)<br>+V(Red)<br>STW 18AWG×2C<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>※ D-Type<br>245<br>12 221<br>9.6<br>300±20<br>FG (Green/Yellow) 106.9 300±20<br>AC/L(Brown) tc<br>AC/N(Blue) STW 18AWG×3C -V(Black)<br>STW 18AWG×2C +V(Red)<br>ψ4.2×4PL<br>‧ : Max. Case Temperaturetc<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>9.4<br>34.2 68<br>34<br>9.4<br>38.8<br>**----- End of picture text -----**<br> _File Name:HVGC-150-SPEC 2022-02-18_ **HVGC - 150 series** 150W Constant Current Mode LED Driver ## **WATERPROOF CONNECTION** ※ **Waterproof connector** Waterproof connector can be assembled on the output cable of HVGC-150 to operate in dry/wet/damp or outdoor environment. **==> picture [494 x 605] intentionally omitted <==** **----- Start of picture text -----**<br> AC<br>HVGC-150<br>source I/P O/P<br>Size Pin Configuration (Female) Size Pin Configuration (Female)<br>M12 M15<br>4-PIN 5-PIN 2-PIN<br>5A/PIN 5A/PIN 12A/PIN<br>Order No. M12-04 M12-05 Order No. M15-02<br>Suitable Current 10A max. 10A max. Suitable Current 12A max. LED Lamp<br>※ Cable Joiner<br>CJ04-1 suitable for 14AWG~16AWG<br>66<br>CJ04-2 suitable for 18AWG~22AWG<br>26 20<br>Up to four wires can be connected through this cable joiner by<br>soldering or clamping by tools.<br>LED Lamp<br>HVGC-150<br>O/P Wires<br>◎ CJ04 cable joiner can be purchased independently for user's own assembly.<br> MEAN WELL order No. : CJ04-1, CJ04-2.<br>※ Junction Box Option<br>221 76 10<br>383 5<br>FG (Green/Yellow)<br>AC/L(Brown) -V(Black)<br>AC/N(Blue) +V(Red)<br>SJTW 14AWG×2C<br>SJTW 18AWG×3C<br>2-ψ5<br>3- PF 1/2" 3- PF 1/2"<br>150±20 150±20<br>86<br>◎ Junction box option is available for A - Type. Please contact MEAW WELL for details.<br>25<br>ψ<br>6<br>8.5<br>68 61 32<br>8.5<br>35 38.8<br>**----- End of picture text -----**<br> ## **INSTALLATION MANUAL** Please refer to : http://www.meanwell.com/manual.html _File Name:HVGC-150-SPEC 2022-02-18_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →