- Manufacturer: LEM
- Product type: Current Sensors
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: ± 2%
- Accuracy %: 2%
- Product Range: HTR Series
- Primary Current: 200A
- Sensor Mounting: Panel Mount
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Voltage
- Supply Voltage Range: ± 12V to ± 15V
- Secondary Signal Type: ± 4V
- Supply Voltage DC Max: 15V
- Supply Voltage DC Min: 12V
- Current Sensor Technology: Open Loop, Hall Effect
- Operating Temperature Max: 70°C
- Operating Temperature Min: -10°C
- Current Measuring Range AC: -400A to 400A
- Current Measuring Range DC: -400A to 400A
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 120.47 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Current Transducer HTR 50 ... 500-SB** ## _I_ **= 50 ... 500 A** P N For the electronic measurement of currents: DC, AC, pulsed,..., with galvanic separation between the primary circuit and the secondary circuit. ## ~~**Electrical data** LT~~ |HTR 50-SB|Type<br>HTR 50-SB|Primary nominal Primary current,<br>RMS current measuring range<br> _I_P N(A)<br>50|Primary nominal Primary current,<br>RMS current measuring range<br> _I_P M(A)<br>±100|| |---|---|---|---|---| |HTR 100-SB|HTR 100-SB|100|±200|| |HTR 200-SB<br> HTR 300-SB|HTR 200-SB<br>HTR 300-SB|200<br>300|±400<br>±600|| |HTR 400-SB|HTR 400-SB|400|±800|| |HTR 500-SB|HTR 500-SB|500|±1000|| |_U_out|Output voltage (Analog)|Output voltage (Analog)|±4|V| |_R_L|Load resistance||> 10|kΩ| |_U_C|Supply voltage (±5 %)||±12 ... 15|V| |_I_C|Current consumption (max)||20|mA| ## ~~**Accuracy - Dynamic performance data** LT~~ _ε_ Error[1)] @ _I_ P N, _T_ A = 25 °C, @ ±12 ... 15 V (±5 %) < ±2 % _ε_ L Linearity error[1)] < ±1 % Typ Max _U_ O E Electrical offset voltage @ _I_ P = 0, _T_ A = 25 °C ±45 ±65 mV _U_ O M Magnetic offset voltage @ _I_ P = 0 and specified _R_ M, after an overload of 3 × _I_ P N ±10 ±20 mV _U_ O _T_ Temperature variation of _U_ O, _T_ A = −10 ... +70 °C ±70 ±240 mV _TCS_ Temperature coefficient of _S_ ±140 ±450 mV _t_ D 90 Delay time to 90 % of _I_ P N[2)] < 10 µs _BW_ Frequency bandwidth (−1 dB) DC ... 10 kHz ~~**General data** [~~ _T_ A Ambient operating temperature −10 ... +70 °C _T_ S Ambient storage temperature −20 ... +85 °C _m_ Mass 80 g Standards EN 50178: 1997[3)] UL 508: 2013 ## **Features** - ●Open loop Hall effect transducer - ●Busbar mounting or panel mounting - ●Insulating plastic case recognized according to UL 94-V0. ## **Advantages** - ●Low power consumption - ●Split core easy for mounting - ●High insulation between the primary and the secondary circuit - ●Through-hole, no insertion losses. ## **Applications** - ●Power supplies for TELECOM (monitoring & measuring) - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Electrical chemistry - ●Chopper - ●Battery supplied applications. ## **Application domain** - ●Industrial. Notes:[1)] Excludes the electrical offset - 2) For a d _i_ /d _t_ = 50 A/µs - 3) Regarding compliance towards IEC 61000-4-3 (EN61000-6-2 (2005)): Output is above to 7.7 % of _U_ S N between 80 MHz and 1 GHz with a field intensity of 10 [V/m]. N° 74.22.25.000.0; N° 74.22.34.000.0; N° 74.22.44.000.0; N° 74.22.46.000.0; N° 74.22.48.000.0; N° 74.22.50.000.0; Page 1/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com 17April2019/version9 ## **Current Transducer HTR 50 ... 500-SB** ||~~**Insulation coordination**~~||| |---|---|---|---| |_U_d|RMS voltage for AC insulation test, 50 Hz, 1 min|3|kV| |_U_Ni|Impulse withstand voltage 1.2/50 µs|> 6|kV| |_U_e|Partial discharge extinction RMS voltage|> 1.5|kV| |||Min|| |_d_Cp|Creepage distance|28.1|mm| |_d_CI|Clearance|17.1|mm| |_CTI_|Comparative tracking index (group IIIa)|225|| ## **Applications examples** **According to EN 50178 and IEC 61010-1 standards** and following conditions: - ●Over voltage category OV 3 - ●Pollution degree PD2 - ●Non-uniform field |Pollution degree PD2<br>Non-uniform feld||| |---|---|---| ||**EN 50178**|**IEC 61010-1**| |_d_Cp,_d_CI,_U_Ni|Rated insulation voltage|Nominal voltage| |Basic insulation|1000 V|1000 V| |Reinforced insulation|500 V|500 V| ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 17April2019/version9 ## **Dimensions HTR 50 ... 500-SB** (in mm) **==> picture [363 x 313] intentionally omitted <==** **==> picture [123 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> Connection<br>I P U C<br>R M<br>U C<br>**----- End of picture text -----**<br> **==> picture [195 x 32] intentionally omitted <==** **----- Start of picture text -----**<br> d d<br>Cl Cp<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** - ●General tolerance - ●Primary through hole - ●Fastening Distance between holes axes or Distance between hole and spigot axes - ●Connection of secondary ±1 mm - ⌀ 21 mm 2 holes ⌀ 3.2 mm 50 × 36 mm - 1 hole ⌀ 3.2 mm and 1 spigot ⌀ 2.5 mm 36 mm Molex 5046-04A ## **Remarks** - _U_ out is positive when _I_ P flows in the direction of the arrow. - ●Temperature of the primary conductor should not exceed 100 °C. - ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: . - **https://www.lem.com/en/file/3137/download/** - ●The retrun busbar and primary conductor elbow must be located at least at 2.5 mm × window length more far away from the transducer case. - ●Dynamic performances are best with a primary busbar completely filling the primary aperture. - ●This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com 17April2019/version9
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →