Image not available
Illustrative purposes only
HOYL 400-S-0100
Current Transducer, HOYL-S Series, 400 A, -1kA to 1kA, 1 %, Voltage Output, 4.5 Vdc to 5.5 Vdc
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- SVHC: No SVHC (17-Jan-2022)
- Accuracy: ± 1%
- Accuracy %: 1%
- Product Range: HOYL-S Series
- Response Time: 3µs
- Primary Current: 400A
- Sensor Mounting: Panel Mount
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Voltage
- Supply Voltage Range: 4.5V to 5.5V
- Supply Voltage DC Max: 5.5V
- Supply Voltage DC Min: 4.5V
- Current Sensor Technology: Open Loop, Hall Effect
- Operating Temperature Max: 105°C
- Operating Temperature Min: -40°C
- Current Measuring Range AC: -1kA to 1kA
- Current Measuring Range DC: -1kA to 1kA
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 47.16 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Current Transducer HOYL-S series** _I_ **= 200 … 800 A** P N **Ref: HOYL 200-S-0100, HOYL 400-S-0100, HOYL 600-S-0100, HOYL 800-S-0100** **For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.** ## **Features** - ●Open loop multi-range current transducer - ●Voltage output - ●Single supply +5 V - ●Overcurrent detect 2.93 × _I_ P N (peak value) - ●Galvanic separation between primary and secondary circuit - ●Low power consumption - ●For busbar mounting - ●Aperture: 40 × 13 mm - ●Factory calibrated - ●Mating JST connector: - housing PAP-05V-S - contact SPHD-00xT-P0.5. ## **Advantages** - ●Low offset drift - ●Over-drivable _V_ ref - ●Creepage / clearance > 10.5 mm ## **Applications** - ●AC variable speed and servo motor drives - ●Static converters for DC motor drives - ●Battery supplied applications - ●Uninterruptible Power Supplies (UPS) - ●Switched Mode Power Supplies (SMPS) - ●Power supplies for welding applications - ●Combiner box - ●Solar inverter on DC side of the inverter (MPPT). ## **Standards** - ●IEC 61800-2: 2015 - ●IEC 61800-3: 2004 - ●IEC 61800-5-1: 2007 - ●IEC 62109-1: 2010 - ●UL 508: 2013. ## **Application Domain** - ●Industrial. - ●Fast response - ●Low profile 2 mm pitch connector for 22 to 28 AWG wire. N°97.N5.44.000.0, N°97.N5.48.000.0, N°97.N5.52.000.0, N°97.N5.56.000.0 Page 1/14 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 www.lem.com **HOYL 200** … **800-S series** ## **Absolute maximum ratings** **==> picture [512 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Value<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Value**| |---|---|---|---| ||||| |Maximum supply voltage (not destructive)|_U_C max|V|8| |Maximum supply voltage (not entering non<br>standard modes)|_U_C max|V|6.5| |Maximum primary conductor temperature|_T_B max|°C|120| |Electrostatic discharge voltage|_U_ESD|kV|2| Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may degrade reliability. ## **UL 508: Ratings and assumptions of certification** File # E189713 Volume: 2 Section: 5 ## **Standards** - ●CSA C22.2 NO. 14-10 INDUSTRIAL CONTROL EQUIPMENT - Edition 12 - ●UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 ## **Ratings** **==> picture [512 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Value<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Value**| |---|---|---|---| ||||| |Primary potential involved||V AC/DC|600| |Max surrounding air temperature|_T_A|°C|100| |Primary current|_I_P|A|According to series primary<br>current| |Secondary supply voltage|_U_C|V DC|5| |Output voltage|_V_out|V|0 to 5| ## **Conditions of acceptability** - _1 - These devices have been evaluated for overvoltage category III and for use in pollution degree 2 environment._ - _2 - A suitable enclosure shall be provided in the end-use application._ - _3 - The terminals have not been evaluated for field wiring._ - _5 - Primary terminals shall not be straightened since assembly of housing case depends upon bending of the terminals._ - _6 - Any surface of polymeric housing have not been evaluated as insulating barrier._ - _7 - Low voltage control circuit shall be supplied by an isolating source (such as a transformer, optical isolator, limiting impedance or electro-mechanical relay)._ ## **Marking** Only those products bearing the UR Mark should be considered to be Listed or Recognized and covered under UL's Follow-Up Service. Always look for the Mark on the product. Page 2/14 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 **HOYL 200** … **800-S series** ## **Insulation coordination** **==> picture [512 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Value Comment<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Value**|**Comment**| |---|---|---|---|---| |||||| |RMS voltage for AC insulation test 50/60 Hz/1 min|_U_d|kV|5.1|| |Impulse withstand voltage 1.2/50 µs|_Û_W|kV|9.6|| |Partial discharge RMS test voltage (_q_m< 10 pC)|_U_t|V|1650|Busbar/secondary.<br>According to:<br>IEC 61800-5-1<br>IEC 62109-1| |Clearance (pri. - sec.)|_d_CI|mm|> 10.5|Shortest distance through<br>air| |Creepage distance (pri. - sec.)|_d_Cp|mm|> 10.5|Shortest path along device<br>body| |Case material|-|-|V0|According to UL 94| |Comparative tracking index|_CTI_||600|| |Application example|-|-|600 V<br>CAT III PD2|Reinforced insulation<br>according to<br>IEC 61800-5-1| |Application example|-|-|1000 V<br>CAT III PD2|Basic insulation, non<br>uniform feld according to<br>IEC 61800-5-1| |Application example|-|-|600 V<br>CAT III PD2|According to UL 508| ## **Environmental and mechanical characteristics** |**Parameter**|**Symbol**|**Unit**|**Min**|**Typ**|**Max**|**Comment**| |---|---|---|---|---|---|---| |Ambient operating temperature|_T_A|°C|−40||105|| |Ambient storage temperature|_T_S|°C|−40||105|| |Mass|_m_|g||232||| Page 3/14 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 **HOYL 200** … **800-S series** ## **Electrical data HOYL 200-S-0100** At _T_ A = 25 °C, _U_ C = +5 V, _R_ L = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 12). **==> picture [512 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Min Typ Max Comment<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Min**|**Typ**|**Max**|**Comment**| |---|---|---|---|---|---|---| |||||||| |Primary nominal RMS current|_I_P N|A||200||| |Primary current, measuring range|_I_P M|A|−500||500|2.5 ×_I_P N**@**_U_C ≥ 4.6 V| |Number of primary turns|_N_P|-||1||Bus bar| |Supply voltage1)|_U_C|V|4.5|5|5.5|| |Current consumption|_I_C|mA||19|25|| |Reference voltage (output)|_V_ref|V|2.48|2.5|2.52|Internal reference| |Reference voltage (input)|_V_ref|V|0.5||2.65|External reference| |Output voltage range @_I_P M|_V_out−_V_ref|V|−2||2|Over operating temperature range| |_V_refoutput resistance|_R_ref|Ω|130|200|300|Series| |_V_outoutput resistance|_R_out|Ω||2|5|Series| |Allowed capacitive load|_C_L|nF|0||6|| |Overcurrent detection output on<br>resistance|_R_on|Ω|70|95|150|Open drain, active low<br>Over operating temperature range| |Overcurrent detection hold|_t_hold|ms|0.7|1|1.4|Additional time after threshold has<br>released| |EEPROM control|_V_out|mV|0||50|_V_outforced to GND when EEPROM in<br>an error state2)| |Electrical ofset voltage @_I_P= 0 A|_V_O E|mV|−5||5|_V_out−_V_ref@ _V_ref= 2.5 V| |Electrical ofset current<br>Referred to primary|_I_O E|A|−1.25||1.25|| |Temperature coefcient of_V_ref|_TCV_ref|ppm/K|−170||170|−40 °C … 105 °C| |Temperature coefcient of_V_O E|_TCV_O E|mV/K|−0.075||0.075|−40 °C … 105 °C| |Temperature coefcient of_I_O E<br>@_I_P= 0 A|_TCI_O E|mA/K|−18.75||18.75|−40 °C … 105 °C| |Theoretical sensitivity|_G_th|mV/A||4||800 mV @_I_P N| |Sensitivity error @_I_P N|_εG_|%|−0.5||0.5|Factory adjustment| |Temperature coefcient of_G_|_TCG_|ppm/K|−250||250|−40 °C … 105 °C| |Linearity error 0 …_I_P N|_ε_L|% of_I_P N|−0.5||0.5|| |Linearity error 0 …_I_P M|_ε_L|% of_I_P M|−0.5||0.5|| |Magnetic ofset current (@ 10 ×_I_P N)<br>referred to primary|_I_O M|A|−1.27||1.27|One turn| |Reaction time @ 10 % of_I_P N|_t_ra|µs||3|3.5|@ 100 A/µs| |Response time @ 90 % of_I_P N|_t_r|µs||3|3.5|@ 100 A/µs| |Frequency bandwidth (−3 dB)|_BW_|kHz||140||Small signal| |Output RMS noise voltage (spectral<br>density) 100 Hz … 100 kHz|_e_no|µV/ Hz<br>~~√~~||7.4||| |Output RMS noise voltage<br>(DC … 10 kHz)<br>(DC … 100 kHz)<br>(DC … 1 MHz)|_V_no|mVpp||4.5<br>7.7<br>12.5||| |Primary current, detection threshold|_I_P Th|A|2.64 ×_I_P N|2.93 ×_I_P N|3.22 ×_I_P N|Peak value ±10 %, overcurrent<br>detection OCD| |Accuracy @_I_P N|_X_|% of_I_P N|−1||1|| |Accuracy @_I_P N@_T_A= +105 °C|_X_|% of_I_P N|−3.8||3.8|See formula note3)| |Accuracy @_I_P N@_T_A= +85 °C|_X_|% of_I_P N|−3.1||3.1|| - Notes: 1) 3.3 V SP version available 2) EEPROM in an error state makes the transducer behave like a reverse current saturation. Use of the OCD may help to differentiate the two cases 3) Accuracy @ _T_ A (% of _I_ P N) = _X_ + ( 10000 _TCG_ × ( _T_ A –25) + 1000 _TCI_ O E × _I_ P N × 100 × ( _T_ A –25)). Page 4/14 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 www.lem.com **HOYL 200** … **800-S series** ## **Electrical data HOYL 400-S-0100** At _T_ A = 25 °C, _U_ C = +5 V, _R_ L = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 12). **==> picture [512 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Min Typ Max Comment<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Min**|**Typ**|**Max**|**Comment**| |---|---|---|---|---|---|---| |||||||| |Primary nominal RMS current|_I_P N|A||400||| |Primary current, measuring range|_I_P M|A|−1000||1000|2.5 ×_I_P N**@**_U_C ≥ 4.6 V| |Number of primary turns|_N_P|-||1||Bus bar| |Supply voltage1)|_U_C|V|4.5|5|5.5|| |Current consumption|_I_C|mA||19|25|| |Reference voltage (output)|_V_ref|V|2.48|2.5|2.52|Internal reference| |Reference voltage (input)|_V_ref|V|0.5||2.65|External reference| |Output voltage range @_I_P M|_V_out−_V_ref|V|−2||2|Over operating temperature range| |_V_refoutput resistance|_R_ref|Ω|130|200|300|Series| |_V_outoutput resistance|_R_out|Ω||2|5|Series| |Allowed capacitive load|_C_L|nF|0||6|| |Overcurrent detection output on<br>resistance|_R_on|Ω|70|95|150|Open drain, active low<br>Over operating temperature range| |Overcurrent detection hold|_t_hold|ms|0.7|1|1.4|Additional time after threshold has<br>released| |EEPROM control|_V_out|mV|0||50|_V_outforced to GND when EEPROM<br>in an error state2)| |Electrical ofset voltage @_I_P= 0 A|_V_O E|mV|−5||5|_V_out−_V_ref@ _V_ref= 2.5 V| |Electrical ofset current<br>Referred to primary|_I_O E|A|−2.5||2.5|| |Temperature coefcient of_V_ref|_TCV_ref|ppm/K|−170||170|−40 °C … 105 °C| |Temperature coefcient of_V_O E|_TCV_O E|mV/K|−0.075||0.075|−40 °C … 105 °C| |Temperature coefcient of_I_O E<br>@_I_P= 0 A|_TCI_O E|mA/K|−37.5||37.5|−40 °C … 105 °C| |Theoretical sensitivity|_G_th|mV/A||2||800 mV @_I_PN| |Sensitivity error @_I_P N|_εG_|%|−0.5||0.5|Factory adjustment| |Temperature coefcient of_G_|_TCG_|ppm/K|−250||250|−40 °C … 105 °C| |Linearity error 0 …_I_P N|_ε_L|% of_I_P N|−0.5||0.5|| |Linearity error 0 …_I_P M|_ε_L|% of_I_P M|−0.5||0.5|| |Magnetic ofset current (@ 10 ×_I_P N)<br>referred to primary|_I_O M|A|−1.27||1.27|One turn| |Reaction time @ 10 % of_I_P N|_t_ra|µs||3|3.5|@ 100 A/µs| |Response time @ 90 % of_I_P N|_t_r|µs||3|3.5|@ 100 A/µs| |Frequency bandwidth (−3 dB)|_BW_|kHz||140||Small signal| |Output RMS noise voltage (spectral<br>density) 100 Hz … 100 kHz|_e_no|µV/ Hz<br>~~√~~||6.1||| |Output RMS noise voltage<br>(DC … 10 kHz)<br>(DC … 100 kHz)<br>(DC … 1 MHz)|_V_no|mVpp||4.3<br>6.4<br>9.7||| |Primary current, detection threshold|_I_P Th|A|2.64 ×_I_P N|2.93 ×_I_P N|3.22 ×_I_P N|Peak value ±10 %, overcurrent<br>detection OCD| |Accuracy @_I_P N|_X_|% of_I_P N|−1||1|| |Accuracy @_I_P N@_T_A= +105 °C|_X_|% of_I_P N|−3.8||3.8|See formula note3)| |Accuracy @_I_P N@_T_A= +85 °C|_X_|% of_I_P N|−3.1||3.1|| Notes: 1) 3.3 V SP version available 2) EEPROM in an error state makes the transducer behave like a reverse current saturation. Use of the OCD may help to differentiate the two cases 3) Accuracy @ _T_ A (% of _I_ P N) = _X_ + ( 10000 _TCG_ × ( _T_ A –25) + 1000 _TCI_ O E × _I_ P N × 100 × ( _T_ A –25)). LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 5/14 16February2018/Version 4 www.lem.com **HOYL 200** … **800-S series** ## **Electrical data HOYL 600-S-0100** At _T_ A = 25 °C, _U_ C = +5 V, _R_ L = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 12). **==> picture [512 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Min Typ Max Comment<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Min**|**Typ**|**Max**|**Comment**| |---|---|---|---|---|---|---| |||||||| |Primary nominal RMS current|_I_P N|A||600||| |Primary current, measuring range|_I_P M|A|−1500||1500|2.5 ×_I_P N**@**_U_C ≥ 4.6 V| |Number of primary turns|_N_P|-||1||Bus bar| |Supply voltage1)|_U_C|V|4.5|5|5.5|| |Current consumption|_I_C|mA||19|25|| |Reference voltage (output)|_V_ref|V|2.48|2.5|2.52|Internal reference| |Reference voltage (input)|_V_ref|V|0.5||2.65|External reference| |Output voltage range @_I_P M|_V_out−_V_ref|V|−2||2|Over operating temperature range| |_V_refoutput resistance|_R_ref|Ω|130|200|300|Series| |_V_outoutput resistance|_R_out|Ω||2|5|Series| |Allowed capacitive load|_C_L|nF|0||6|| |Overcurrent detection output on<br>resistance|_R_on|Ω|70|95|150|Open drain, active low<br>Over operating temperature range| |Overcurrent detection hold|_t_hold|ms|0.7|1|1.4|Additional time after threshold has<br>released| |EEPROM control|_V_out|mV|0||50|_V_outforced to GND when EEPROM<br>in an error state2)| |Electrical ofset voltage @_I_P= 0 A|_V_O E|mV|−5||5|_V_out−_V_ref@ _V_ref= 2.5 V| |Electrical ofset current<br>Referred to primary|_I_O E|A|−3.75||3.75|| |Temperature coefcient of_V_ref|_TCV_ref|ppm/K|−170||170|−40 °C … 105 °C| |Temperature coefcient of_V_O E|_TCV_O E|mV/K|−0.075||0.075|−40 °C … 105 °C| |Temperature coefcient of_I_O E<br>@_I_P= 0 A|_TCI_O E|mA/K|−56.25||56.25|−40 °C … 105 °C| |Theoretical sensitivity|_G_th|mV/A||1.333||800 mV @_I_P N| |Sensitivity error @_I_P N|_εG_|%|−0.5||0.5|Factory adjustment| |Temperature coefcient of_G_|_TCG_|ppm/K|−250||250|−40 °C … 105 °C| |Linearity error 0 …_I_P N|_ε_L|% of_I_P N|−0.5||0.5|| |Linearity error 0 …_I_P M|_ε_L|% of_I_P M|−0.5||0.5|| |Magnetic ofset current (@ 10 ×_I_P N)<br>referred to primary|_I_OM|A|−1.27||1.27|One turn| |Reaction time @ 10 % of_I_P N|_t_ra|µs||3|3.5|@ 100 A/µs| |Response time @ 90 % of_I_P N|_t_r|µs||3|3.5|@ 100 A/µs| |Frequency bandwidth (−3 dB)|_BW_|kHz||140||Small signal| |Output RMS noise voltage (spectral<br>density) 100 Hz … 100 kHz|_e_no|µV/ Hz<br>~~√~~||5.7||| |Output RMS noise voltage<br>(DC … 10 kHz)<br>(DC … 100 kHz)<br>(DC … 1 MHz)|_V_no|mVpp||4.3<br>6.0<br>8.8||| |Primary current, detection threshold|_I_P Th|A|2.64 ×_I_P N|2.93 ×_I_P N|3.22 ×_I_P N|Peak value ±10 %, overcurrent<br>detection OCD| |Accuracy @_I_P N|_X_|% of_I_P N|−1||1|| |Accuracy @_I_P N@_T_A= +105 °C|_X_|% of_I_P N|−3.8||3.8|See formula note3)| |Accuracy @_I_P N@_T_A= +85 °C|_X_|% of_I_P N|−3.1||3.1|| Notes: 1) 3.3 V SP version available 2) EEPROM in an error state makes the transducer behave like a reverse current saturation. Use of the OCD may help to differentiate the two cases 3) Accuracy @ _T_ A (% of _I_ P N) = _X_ + ( 10000 _TCG_ × ( _T_ A –25) + 1000 _TCI_ O E × _I_ P N × 100 × ( _T_ A –25)). LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 6/14 16February2018/Version 4 www.lem.com **HOYL 200** … **800-S series** ## **Electrical data HOYL 800-S-0100** At _T_ A = 25 °C, _U_ C = +5 V, _R_ L = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 12). **==> picture [512 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Parameter Symbol Unit Min Typ Max Comment<br>**----- End of picture text -----**<br> |**Parameter**|**Symbol**|**Unit**|**Min**|**Typ**|**Max**|**Comment**| |---|---|---|---|---|---|---| |||||||| |Primary nominal RMS current|_I_P N|A||800||| |Primary current, measuring range|_I_P M|A|−2000||2000|2.5 ×_I_P N**@**_U_C ≥ 4.6 V| |Number of primary turns|_N_P|-||1||Bus bar| |Supply voltage1)|_U_C|V|4.5|5|5.5|| |Current consumption|_I_C|mA||19|25|| |Reference voltage (output)|_V_ref|V|2.48|2.5|2.52|Internal reference| |Reference voltage (input)|_V_ref|V|0.5||2.65|External reference| |Output voltage range @_I_P M|_V_out−_V_ref|V|−2||2|Over operating temperature range| |_V_refoutput resistance|_R_ref|Ω|130|200|300|Series| |_V_outoutput resistance|_R_out|Ω||2|5|Series| |Allowed capacitive load|_C_L|nF|0||6|| |Overcurrent detection output on<br>resistance|_R_on|Ω|70|95|150|Open drain, active low<br>Over operating temperature range| |Overcurrent detection hold|_t_hold|ms|0.7|1|1.4|Additional time after threshold has<br>released| |EEPROM control|_V_out|mV|0||50|_V_outforced to GND when EEPROM<br>in an error state2)| |Electrical ofset voltage @_I_P= 0 A|_V_O E|mV|−5||5|_V_out−_V_ref@ _V_ref= 2.5 V| |Electrical ofset current<br>Referred to primary|_I_O E|A|−5||5|| |Temperature coefcient of_V_ref|_TCV_ref|ppm/K|−170||170|−40 °C … 105 °C| |Temperature coefcient of_V_O E|_TCV_O E|mV/K|−0.075||0.075|−40 °C … 105 °C| |Temperature coefcient of_I_O E<br>@_I_P= 0 A|_TCI_O E|mA/K|−75||75|−40 °C … 105 °C| |Theoretical sensitivity|_G_th|mV/A||1||800 mV @_I_P N| |Sensitivity error @_I_P N|_εG_|%|−0.5||0.5|Factory adjustment| |Temperature coefcient of_G_|_TCG_|ppm/K|−250||250|−40 °C … 105 °C| |Linearity error 0 …_I_P N|_ε_L|% of_I_P N|−0.5||0.5|| |Linearity error 0 …_I_P M|_ε_L|% of_I_P M|−0.5||0.5|| |Magnetic ofset current (@ 10 ×_I_P N)<br>referred to primary|_I_O M|A|−1.27||1.27|One turn| |Reaction time @ 10 % of_I_P N|_t_ra|µs||3|3.5|@ 100 A/µs| |Response time @ 90 % of_I_P N|_t_r|µs||3|3.5|@ 100 A/µs| |Frequency bandwidth (−3 dB)|_BW_|kHz||140||Small signal| |Output RMS noise voltage (spectral<br>density) 100 Hz … 100 kHz|_e_no|µV/ Hz<br>~~√~~||5.5||| |Output RMS noise voltage<br>(DC … 10 kHz)<br>(DC … 100 kHz)<br>(DC … 1 MHz)|_V_no|mVpp||4.2<br>5.8<br>8.4||| |Primary current, detection threshold|_I_P Th|A|2.64 ×_I_P N|2.93 ×_I_P N|3.22 ×_I_P N|Peak value ±10 %, overcurrent<br>detection OCD| |Accuracy @_I_P N|_X_|% of_I_P N|−1||1|| |Accuracy @_I_P N@_T_A= +105 °C|_X_|% of_I_P N|−3.8||3.8|See formula note3)| |Accuracy @_I_P N@_T_A= +85 °C|_X_|% of_I_P N|−3.1||3.1|| Notes: 1) 3.3 V SP version available 2) EEPROM in an error state makes the transducer behave like a reverse current saturation. Use of the OCD may help to differentiate the two cases 3) Accuracy @ _T_ A (% of _I_ P N) = _X_ + ( 10000 _TCG_ × ( _T_ A –25) + 1000 _TCI_ O E × _I_ P N × 100 × ( _T_ A –25)). LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 7/14 16February2018/Version 4 www.lem.com **HOYL 200** … **800-S series** ## **Measuring range versus external reference voltage** **==> picture [313 x 612] intentionally omitted <==** **----- Start of picture text -----**<br> 1200<br>900<br>600 Uc = 5 V<br>Uc = 4.75 V<br>Uc = 4.6 V<br>300<br>HOYL 200-S<br>0<br>-300<br>-600<br>-900<br>-1200<br>0.5 1 1.5 2 2.5<br>V ref (V)<br>2500<br>2000<br>1500<br>Uc = 5 V<br>1000 Uc = 4.75 V<br>Uc = 4.6 V<br>500<br>HOYL 400-S<br>0<br>-500<br>-1000<br>-1500<br>-2000<br>-2500<br>0.5 1 1.5 2 2.5<br>V ref (V)<br>2500<br>2000<br>Uc = 5 V<br>1500 Uc = 4.75 V<br>Uc = 4.6 V<br>1000<br>500<br>HOYL 600-S<br>0<br>-500<br>-1000<br>-1500<br>-2000<br>-2500<br>0.5 1 1.5 2 2.5<br>V ref (V)<br>I (A)P<br>I (A)P<br>I (A)P<br>**----- End of picture text -----**<br> Page 8/14 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 www.lem.com **HOYL 200** … **800-S series** ## **Measuring range versus external reference voltage** **==> picture [313 x 197] intentionally omitted <==** **----- Start of picture text -----**<br> 2500<br>2000 UUcc = 5 V = 4.75 V<br>1500 Uc = 4.6 V<br>1000<br>500<br>HOYL 800-S<br>0<br>-500<br>-1000<br>-1500<br>-2000<br>-2500<br>0.5 1 1.5 2 2.5<br>V ref (V)<br>I (A)P<br>**----- End of picture text -----**<br> Page 9/14 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 www.lem.com **HOYL 200** … **800-S series** ## **Maximum continuous DC current** For all ranges: **==> picture [394 x 224] intentionally omitted <==** **----- Start of picture text -----**<br> 2500<br>HOYL 200 ... 800-S<br>2000<br>1500<br>1000<br>500<br>0<br>-40 -20 0 20 40 60 80 100 120 140<br>T A (°C)<br>(A)<br>P<br>I<br>**----- End of picture text -----**<br> Important notice: whatever the usage and/or application, the transducer primary bar / jumper temperature shall not go above the maximum rating of 120 °C as stated in page 2 of this datasheet. Page 10/14 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 **HOYL 200** … **800-S series** ## **HOYL-S series: name and codification** HOYL-S family products may be ordered _**on request**_[1)] with a dedicated setting of the parameters as described below (standard products are delivered with the setting 0100 according to the table). ## **HOYL-S-XXXX** |**_Internal_**|**_reference_**2)|**_Response time_**|**_Response time_**|**_EEPROM Control_**|**_EEPROM Control_**|**_Overcurrent_**|**_Overcurrent_**|**_detection (_**×_I_P N)3)|**_detection (_**×_I_P N)3)| |---|---|---|---|---|---|---|---|---|---| |0|2.5 V|0|4 µs|0|YES|0|2.93|<br>A|0.68| |1|1.65 V|1|3 µs|1|NO|1|3.59|<br>B|0.93| |2|1.5 V|2|6 µs|||2|3.99|<br>C|1.17| |3|0.5 V|||||3|4.77|<br>D|1.44| |4|External_V_refonly|||||4|5.19|<br>E|1.60| |||||||5|5.76|<br>F|1.91| |||||||6|1.68|<br>G|2.08| |||||||7|2.35|<br>H|2.31| Notes:[1)] For dedicated settings, minimum quantities apply, please contact your local LEM support 2) _V_ ref electrical data **==> picture [277 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> V ref V ref (V) TCV ref (ppm/ K )<br>parameter min typ max min max<br>0 2.48 2.5 2.52 −170 170<br>1 1.63 1.65 1.67 −170 170<br>2 1.48 1.5 1.52 −170 170<br>3 0.49 0.5 0.51 −250 250<br>**----- End of picture text -----**<br> > 3) OCD (× _I_ P N) correction table versus range and temperature. All other values or empty cells: no change **==> picture [223 x 205] intentionally omitted <==** **----- Start of picture text -----**<br> HOYL-S-010x<br>OCD<br>Parameter<br>200 400 600 800<br>A<br>B<br>C<br>D<br>E<br>6<br>F<br>G<br>H<br>7<br>0<br>1<br>2<br>3 7.06<br>4 -<br>5 6.03 -<br>**----- End of picture text -----**<br> **==> picture [187 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> Tolerance on OCD value<br>±20 %<br>±15 %<br>±10 % No change<br>- Do not use<br>**----- End of picture text -----**<br> Page 11/14 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 **HOYL 200** … **800-S series** ## **Application information** HOYL-S series is designed to be used with a bus-bar or cable[1)] to carry the current through the aperture with a maximum crosssection of 40 × 13 mm. Note:[1)] The maximum magnetic offset referred to primary is inversely proportional to the number of turns, thus is divided by 2 with 2 turns. ## **Definition of typical, minimum and maximum values** Minimum and maximum values for specified limiting and safety conditions have to be understood as such as well as values shown in “typical” graphs. On the other hand, measured values are part of a statistical distribution that can be specified by an interval with upper and lower limits and a probability for measured values to lie within this interval. Unless otherwise stated (e.g. “100 % tested”), the LEM definition for such intervals designated with “min” and “max” is that the probability for values of samples to lie in this interval is 99.73 %. For a normal (Gaussian) distribution, this corresponds to an interval between −3 sigma and +3 sigma. If “typical” values are not obviously mean or average values, those values are defined to delimit intervals with a probability of 68.27 %, corresponding to an interval between −sigma and +sigma for a normal distribution. Typical, minimum and maximum values are determined during the initial characterization of the product. ## **Remark** Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: **Products/Product Documentation** ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61800-5-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage.This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 12/14 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 **HOYL 200** … **800-S series** ## **Insulation distance (nominal values):** |**ulation distance (nominal values):**||| |---|---|---| ||_d_Cp|_d_CI| |Betweenprimarybusbar and secondary pins|24.3 mm|24.3 mm| |Betweenprimarybusbar and core|21.1 mm|-| |Between core and secondaryterminal|12.3 mm|12.3 mm| Page 13/14 www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 **HOYL 200** … **800-S series** ## **Dimensions** (mm, general linear tolerance ±0.3 mm) **==> picture [511 x 512] intentionally omitted <==** **----- Start of picture text -----**<br> Connection<br>Cref 1 µF I P VV ref out (IN/OUT)<br>C U C 47 nF<br>U C +U C<br>**----- End of picture text -----**<br> ## **Remarks:** - _V_ out is positive with respect to _V_ ref when positive _I_ P flows in direction of the arrow shown on the drawing above. - ●Connection system equivalent to JST B05B-PASK. - ●Transducer fastening 1 hole ⌀ 4.5 mm 1 steel screw M4 - Recommended fastening torque 4 N ⋅ m Page 14/14 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 16February2018/Version 4 www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →