Image not available
Illustrative purposes only
HLP-60H-42
LED Driver, ITE, Household & LED Lighting, 60.9 W, 42 V, 1.45 A, Constant Current, 90 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (23-Jan-2024)
- Product Range: HLP-60H Series
- Output Current: 1.45A
- LED Driver Mode: Constant Current
- Output Power Max: 60.9W
- Input Voltage Max: 305V
- Input Voltage Min: 90V
- Output Voltage Max: 42V
- Power Supply Applications: ITE, Household & LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 31.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- HLP 60H series** 60W Single Output Switching Power Supply ## ■ **==> picture [43 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ ## ■ **** - ‧ **SPECIFICATION** ~~BT~~ ** ** & AW Wi; FAL ~~4)-~~ www.IDBauarSicherheitbeegelod2000000000wacmatuv.comt geprufto ges g |@CBC €uK **MODEL HLP-60H-15 HLP-60H-20 HLP-60H-24 HLP-60H-30 HLP-60H-36 HLP-60H-42 HLP-60H-48 HLP-60H-54** ~~rer~~ s rs Ge ~~YQ~~ **DC VOLTAGE** 15V 20V 24V 30V 36V 42V 48V 54V **CONSTANT CURRENT REGION Note.4** 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V 32.4 ~ 54V ~~es~~ ny GO ~~CC GQ~~ **RATED CURRENT** 4A 3A 2.5A OQ 2A 1.7A 1.45A 1.3A 1.15A ~~GG~~ **RATED POWER** 60W 60W 60W 60W 61.2W 60.9W 62.4W 62.1W **RIPPLE & NOISE (max.) Note.2** 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 300mVp-p 300mVp-p 300mVp-p ~~—~~ **VOLTAGE ADJ. RANGE** 13.5 ~ 17V 17 ~ 22V 22 ~ 27V 27 ~ 33V 33 ~ 40V ~~OO~~ 40 ~ 46V 44 ~ 53V 49 ~ 58V **OUTPUT** Can be adjusted by internal potentiometer **CURRENT ADJ. RANGE** a 2.4 ~ 4A 1.8 ~ 3A 1.5 ~ 2.5A 1.2 ~ 2A 1 ~ 1.7A 0.87 ~ 1.45A 0.78 ~ 1.3A 0.69 ~ 1.15A **VOLTAGE TOLERANCE Note.3** ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% es ~~GG Gs~~ **LINE REGULATION** ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% **LOAD REGULATION** ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ~~es GQ~~ **SETUP, RISE TIME Note.6** 500ms, 80ms at full load 230VAC / 115VAC a ~~GO =~~ **HOLD UP TIME (Typ.)** CC ~~[TTT] es~~ 16ms/230VAC 16ms/115VAC at full load ~~esGsQO Gn~~ **VOLTAGE RANGE Note.5** 90 ~ 305VAC 127 ~ 431VDC a **FREQUENCY RANGE** 47 ~ 63Hz **POWER FACTOR (Typ.)** PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) a a **TOTAL HARMONIC DISTORTION** THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input **INPUT** GD **EFFICIENCY (Typ.)** 88% 89% GQ 89.5% 90% 90% 90% 90.5% 90.5% **AC CURRENT (Typ.)** 0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC ~~|~~ **INRUSH CURRENT (Typ.)**[Cn] COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC **MAX. No. of PSUs on 16A** 9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC **CIRCUIT BREAKER LEAKAGE CURRENT** <0.75mA / 277VAC ~~aH#!~~ 95 ~ 108% **OVER CURRENT Note.4** po ~~pe~~ Protection type : Constant current limiting, recovers automatically after fault condition is removed ~~|~~ **SHORT CIRCUIT** Hiccup mode, recovers automatically after fault condition is removed **PROTECTION** 18 ~ 24V 23 ~ 30V 28 ~ 35V 35 ~ 43V 41 ~ 49V 48 ~ 58V 54 ~ 65V 59 ~ 68V **OVER VOLTAGE** Protection type : Shut down o/p voltage, re-power on to recover ~~————————————|~~ **OVER TEMPERATURE** Shut down o/p voltage, re-power on to recover **WORKING TEMP.** -40 ~ +70℃ (Refer to "Derating Curve") ~~a~~ **WORKING HUMIDITY** 20 ~ 95% RH non-condensing **ENVIRONMENT** ~~|~~ **STORAGE TEMP., HUMIDITY** -40 ~ +80℃, 10 ~ 95% RH **TEMP. COEFFICIENT** ±0.03%/℃ (0 ~ 50℃) ~~—EeE—————————~~ **VIBRATION** 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), BS EN/EN61347-1, BS EN/EN61347-2-13, GB19510.14, GB19510.1, **SAFETY STANDARDS** EAC TP TC 004 approved ; design refer to UL60950-1, BS EN/EN60335-1 es **SAFETY &** ~~a~~ **WITHSTAND VOLTAGE** I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC **EMC** ~~|~~ **ISOLATION RESISTANCE** I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH **EMC EMISSION** Compliance to BS EN/EN55015, GB17743, GB17625.1, BS EN/EN61000-3-2 Class C (≧60% load) ; BS EN/EN61000-3-3, EAC TP TC 020 **EMC IMMUNITY** Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), ~~——————~~ ee EAC TP TC 020 a **MTBF** 3130.5K hrs min. Telcordia SR-332(Bellcore) ; 288.5K hrs min. MIL-HDBK-217F (25℃) **OTHERS DIMENSION** 147*53*27mm (L*W*H) ~~=~~ **PACKING** ~~OOOO~~ 0.2Kg;72pcs/15.4Kg/1.01CUFT **NOTE** ℃ ~~fo~~ ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:HLP-60H-SPEC 2022-02-18_ **- HLP 60H series** ## 60W Single Output Switching Power Supply **==> picture [487 x 646] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Unit:mm<br>147<br>3.5 140<br>CN2<br>6<br>5 6<br>4 5<br>3 4<br>2 SVR1 SVR2 3<br>1 2<br>CN1 FS1 1<br>T3.15A/300V Io Vo<br>ADJ ADJ<br>AC Input Connector (CN1) : JST B6P-VH or equivalent DC Output Connector (CN2) : JST B6P-VH or equivalent<br>Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal<br>1 AC/L 1 DIM+<br>2,4,5 No Pin JST VHR JST SVH-21T-P1.1 2 DIM- JST VHR JST SVH-21T-P1.1<br>3 AC/N or equivalent or equivalent 3,4 -V or equivalent or equivalent<br>6 FG 5,6 +V<br>: Grounding required<br>Block Diagram<br>fosc : 100KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.L.P. DIM+<br>DIM-<br>O.T.P. O.L.P. DETECTION<br>FG<br>PWM & PFC CIRCUIT<br>CONTROL<br>O.V.P.<br>Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>230VAC 80<br>Input only<br>60 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 305<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>5<br>53 43<br>27max.<br>3max.<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:HLP-60H-SPEC 2022-02-18_ **- HLP 60H series** 60W Single Output Switching Power Supply ## **Power Factor Characteristic** **==> picture [271 x 382] intentionally omitted <==** **----- Start of picture text -----**<br> Constant Current Mode<br>1<br>0 .9 9<br>0 .9 8<br>0 .9 7<br>0 .9 6<br>0 .9 5<br>0 .9 4<br>0 .9 3 2 7 7 V A C<br>0 .9 2<br>2 3 0 V A C<br>0 .9 1<br>0 .9 1 1 5 V A C<br>0 .8 9<br>0 .8 8<br>0 .8 7<br>0 .8 6<br>0 .8 5<br>0 .8 4<br>5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 %<br>(60W)<br>LOAD<br>EFFICIENCY vs LOAD (48V Model)<br>93<br>92<br>91<br>90<br>89<br>88<br>87<br>86<br>277VAC<br>85<br>84 230VAC<br>83 115VAC<br>82<br>81<br>80<br>79<br>78<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>PF<br>EFFICIENCY (%)<br>**----- End of picture text -----**<br> HLP-60H series possess superior working efficiency that up to 90.5% can be reached in field applications. ## **DRIVING METHODS OF LED MODULE** This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs. **==> picture [429 x 149] intentionally omitted <==** **----- Start of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver<br>100<br>depends on the configuration of the end systems.<br>Should there be any compatibility issues, please contact MEAN WELL.<br>Constant<br>Current area<br>60<br>(min.)<br>Hiccup<br>Protection<br>50 100 Io (%)<br>Typical LED power supply I-V curve<br>Vo(%)<br>**----- End of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. _File Name:HLP-60H-SPEC 2022-02-18_ **- HLP 60H series** 60W Single Output Switching Power Supply ## **DIMMING OPERATION** **==> picture [328 x 107] intentionally omitted <==** **----- Start of picture text -----**<br> FG<br>+V<br>+V<br>AC/N -V<br>-V<br>AC/L DIM-<br>DIM+<br>**----- End of picture text -----**<br> - ※ Output constant current level can be adjusted through output connector by 1~10VDC, PWM signal, or connecting a resistance between DIM+ and DIM-. - ※ Please DO NOT connect "DIM-" to "-V". |※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".|※Please DO NOT connect "DIM-" to "-V".| |---|---|---|---|---|---|---|---|---|---|---|---|---| |※Reference resistance value for output current adjustment (Typical)||||||||||||| |Resistance<br>value|Single driver<br>|10KΩ|20KΩ|30KΩ|40KΩ|50KΩ|60KΩ|70KΩ|80KΩ|90KΩ|100KΩ|OPEN| ||Multiple drivers<br>(N=driver quantity for synchronized<br> dimmingoperation)<br>|10KΩ/N|20KΩ/N|30KΩ/N|40KΩ/N|50KΩ/N|60KΩ/N|70KΩ/N|80KΩ/N|90KΩ/N|100KΩ/N|-----| |Percentage of rated current||10%|20%|30%|40%|50%|60%|70%|80%|90%|100%|95%~108%| |※1 ~ 10V dimming function for output current adjustment (Typical)||||||||||||| |Dimming value||1V|2V|3V|4V|5V|6V|7V|8V|9V|10V|OPEN| |Percentage of rated current||10%|20%|30%|40%|50%|60%|70%|80%|90%|100%|95%~108%| |※10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz||||||||||||| |Duty value||10%|20%|30%|40%|50%|60%|70%|80%|90%|100%|OPEN| |Percentage of rated current||10%|20%|30%|40%|50%|60%|70%|80%|90%|100%|95%~108%| ※Using the built-in dimming function can't turn the lighting fixture totally dark. Please refer to the connection method below to achieve 0% brightness of the lighting fixture connecting to the LED power supply unit. Dimming connection diagram for turning the lighting fixture ON/OFF : **==> picture [382 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> N FG L<br>Relay Switch Adjuster<br>10~100K Ohms resistance<br>1~10V DC Voltage<br>10V PWM Signal<br>Blue<br>Green/ DIM+ White<br>Yellow Brown AC/LAC/N HLP-60H DIM-V(-)V(+) BlackRed LED Lighting Fixture<br>Blue<br>**----- End of picture text -----**<br> Using a switch and relay can turn ON/OFF the lighting fixture. 1.Output constant current level can be adjusted through output connector by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-. 2.The LED lighting fixture can be turned ON/OFF by the switch. _File Name:HLP-60H-SPEC 2022-02-18_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →