Image not available
Illustrative purposes only
HDR-30-24
AC/DC DIN Rail Power Supply (PSU), Ultra Slim, ITE, 1 Output, 36 W, 24 VDC, 1.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- No. of Outputs:1 Output; Output Power Max:36W; Output Voltage - Output 1:24V; Output Current - Output 1:1.5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltag
- SVHC: No SVHC (25-Jun-2025)
- Product Range: HDR-30 Series
- No. of Outputs: 1 Output
- Output Power Max: 36W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 18.24 € |
| Current stock | 1000+ |
| Lead time | 30 days |
**- HDR 30 series** ## 30W Ultra Slim Step Shape DIN Rail **==> picture [42 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> **==> picture [334 x 60] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>LPS @x UL508 Abn UL62368 1- (S/S BS EN/EN61558www.ID 2000000000tuv.com hnerl TPTC004 HA AS/NZS60950-1 & CBC IEC62368-1 ELSE?CA<br>■ Features ■<br>Ultra slim design with 35mm(<br>**----- End of picture text -----**<br> Ⅱ ass LPS (Limited power source) > ooling by free air convection (working temperature:-30~+70°C) ■ GTIN CODE DIN rail TS-35/7.5 or 15 mountable MW Search: https://www.meanwell.com/serviceGTIN.aspx ED indicator for power on ## ■ ℃ ℃ ## ■ _File Name:HDR-30-SPEC 2024-03-11_ **- HDR 30 series** ## 30W Ultra Slim Step Shape DIN Rail ## **SPECIFICATION** ||**HDR-30-5**<br>**HDR-30-12**<br>**HDR-30-15**<br>**HDR-30-24**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>12V<br>15V<br>24V<br>3A<br>2A<br>2A<br>1.5A<br>0 ~ 3A<br>0 ~ 2A<br>0 ~ 2A<br>0 ~ 1.5A<br>15W<br>24W<br>30W<br>36W<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>150mVp-p<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>47 ~ 63Hz<br>82%<br>88%<br>89%<br>89%<br>0.88A/115VAC 0.48A/230VAC<br>COLD START 25A/115VAC 45A/230VAC<br>105 ~ 160% rated output power<br>Protection type : Shut down o/p voltage, re-power on to recover<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>) RH non-condensing<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:4KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**HDR-30-48**<br>48V<br>0.75A<br>0 ~ 0.75A<br>36W<br>240mVp-p<br>±1.0%<br>±1.0%<br>±1.0%<br>90%<br>13.5 ~ 18V<br>21.6 ~ 29V<br>10.8 ~ 1 . V<br>3 8<br>4. ~ . V<br>5<br>5 5<br>43.2 ~ 55.2V<br>5 75<br>7.5<br>. ~ V<br>1 ~ 1 V<br>5<br>8<br>18.8 ~ 22.5V<br>30 ~ 36V<br>5 . ~ 6 . V<br>7 6<br>7 2<br>85 ~ 2 VAC (<br>) 120 ~ 3 VDC (<br>)<br>64<br>277VAC operational<br>70<br>390VDC operational<br>**OPERATING ALTITUDE**<br>2000 meters<br>UL62368-1, U 508, TUV<br>EN61558-2-16<br>,IEC62368-1,<br>, BSMI CNS15598-1 a<br>BS EN/<br>L<br>,<br>pproved;<br>BS EN/EN61558-1<br>EAC TP TC 004<br>Design refer to TUV<br>EN62368-1<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2,<br>EN61204-3<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032(CISPR32), CNS15936<br>BS EN/EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>BS EN/EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>BS EN/<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>BS EN/<br>EN61000-4-4<br>BS EN/<br>EN61000-4-6<br>BS EN/<br>EN61000-4-5<br>BS EN/<br>EN61000-4-8<br>BS EN/<br>EN61000-4-11<br>BS EN/<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>BS EN/EN55032(CISPR32), CNS15936<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>35*90*54.5mm (W*H*D)<br>0.13Kg 96pcs/14.2Kg/1.04CUFT<br>;<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>μ<br>μ<br>F<br>F<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>※Product Liability Disclaimer<br>For detailed information, please refer to<br>:<br>><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>><br>**OVER VOLTAGE CATEGORY**<br>According to E 61558, EN50178,EN60664-1, EN62477-1 altitude up to 2000<br>;<br>;<br>N<br>meters<br>Ⅲ<br>H<br>, recovers automatically after fault condition is removed<br>iccup mode when output voltage 50<br><<br>%<br>Constant current limiting<br>recovers automatically after fault condition is removed<br>���������������������������������<br>3670.4K hrs min.<br>Telcordia SR-332 (Bellcore) ; 968.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃|**HDR-30-5**<br>**HDR-30-12**<br>**HDR-30-15**<br>**HDR-30-24**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>12V<br>15V<br>24V<br>3A<br>2A<br>2A<br>1.5A<br>0 ~ 3A<br>0 ~ 2A<br>0 ~ 2A<br>0 ~ 1.5A<br>15W<br>24W<br>30W<br>36W<br>80mVp-p<br>120mVp-p<br>120mVp-p<br>150mVp-p<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load<br>30ms/230VAC 12ms/115VAC at full load<br>47 ~ 63Hz<br>82%<br>88%<br>89%<br>89%<br>0.88A/115VAC 0.48A/230VAC<br>COLD START 25A/115VAC 45A/230VAC<br>105 ~ 160% rated output power<br>Protection type : Shut down o/p voltage, re-power on to recover<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>) RH non-condensing<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:4KVAC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**HDR-30-48**<br>48V<br>0.75A<br>0 ~ 0.75A<br>36W<br>240mVp-p<br>±1.0%<br>±1.0%<br>±1.0%<br>90%<br>13.5 ~ 18V<br>21.6 ~ 29V<br>10.8 ~ 1 . V<br>3 8<br>4. ~ . V<br>5<br>5 5<br>43.2 ~ 55.2V<br>5 75<br>7.5<br>. ~ V<br>1 ~ 1 V<br>5<br>8<br>18.8 ~ 22.5V<br>30 ~ 36V<br>5 . ~ 6 . V<br>7 6<br>7 2<br>85 ~ 2 VAC (<br>) 120 ~ 3 VDC (<br>)<br>64<br>277VAC operational<br>70<br>390VDC operational<br>**OPERATING ALTITUDE**<br>2000 meters<br>UL62368-1, U 508, TUV<br>EN61558-2-16<br>,IEC62368-1,<br>, BSMI CNS15598-1 a<br>BS EN/<br>L<br>,<br>pproved;<br>BS EN/EN61558-1<br>EAC TP TC 004<br>Design refer to TUV<br>EN62368-1<br>BS EN/<br>BS EN/<br>BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2,<br>EN61204-3<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032(CISPR32), CNS15936<br>BS EN/EN61000-3-2<br>**Test Level / Note**<br>Class B<br>-------<br>BS EN/EN61000-3-3<br>Class B<br>Class A<br>**Parameter**<br>ESD<br>Radiated Susceptibility<br>EFT/Burest<br>Surge<br>**Standard**<br>EN61000-4-2<br>BS EN/<br>**Test Level /Note**<br>Level 3, 8KV air; Level 2, 4KV contact, criteria A<br>Level 4,2KV/L-N, criteria A<br>Conducted<br>Magnetic Field<br>EN61000-4-3<br>BS EN/<br>EN61000-4-4<br>BS EN/<br>EN61000-4-6<br>BS EN/<br>EN61000-4-5<br>BS EN/<br>EN61000-4-8<br>BS EN/<br>EN61000-4-11<br>BS EN/<br>Voltage Dips and interruptions<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 3, criteria A<br>Level 4, criteria A<br>BS EN/EN55032(CISPR32), CNS15936<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>35*90*54.5mm (W*H*D)<br>0.13Kg 96pcs/14.2Kg/1.04CUFT<br>;<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>μ<br>μ<br>F<br>F<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>※Product Liability Disclaimer<br>For detailed information, please refer to<br>:<br>><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>><br>**OVER VOLTAGE CATEGORY**<br>According to E 61558, EN50178,EN60664-1, EN62477-1 altitude up to 2000<br>;<br>;<br>N<br>meters<br>Ⅲ<br>H<br>, recovers automatically after fault condition is removed<br>iccup mode when output voltage 50<br><<br>%<br>Constant current limiting<br>recovers automatically after fault condition is removed<br>���������������������������������<br>3670.4K hrs min.<br>Telcordia SR-332 (Bellcore) ; 968.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃|**HDR-30-5**|**HDR-30-12**|**HDR-30-12**|**HDR-30-15**|**HDR-30-24**|**HDR-30-24**|**HDR-30-48**| |---|---|---|---|---|---|---|---|---|---| |||**DC VOLTAGE**|5V|12V||15V|24V||48V| |||**RATED CURRENT**|3A|2A||2A|1.5A||0.75A| |||**CURRENT RANGE**|0 ~ 3A|0 ~ 2A||0 ~ 2A|0 ~ 1.5A||0 ~ 0.75A| |||**RATED POWER**|15W|24W||30W|36W||36W| |||**RIPPLE & NOISE (max.) Note.2**|80mVp-p|120mVp-p||120mVp-p|150mVp-p||240mVp-p| |||**VOLTAGE ADJ. RANGE**|4. ~ . V<br>5<br>5 5|10.8 ~ 1 . V<br>3 8||13.5 ~ 18V|21.6 ~ 29V||43.2 ~ 55.2V| |||**VOLTAGE TOLERANCE Note.3**|±2.0%|±1.0%||±1.0%|±1.0%||±1.0%| |||**LINE REGULATION**|±1.0%|±1.0%||±1.0%|±1.0%||±1.0%| |||**LOAD REGULATION**|±1.0%|±1.0%||±1.0%|±1.0%||±1.0%| |||**SETUP, RISE TIME**|500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load||||||| |||**HOLD UP TIME (Typ.)**|30ms/230VAC 12ms/115VAC at full load||||||| |||**VOLTAGE RANGE**|85 ~ 2 VAC (<br>) 120 ~ 3 VDC (<br>)<br>64<br>277VAC operational<br>70<br>390VDC operational||||||| |||**FREQUENCY RANGE**|47 ~ 63Hz||||||| |||**EFFICIENCY (Typ.)**|82%|88%||89%|89%||90%| |||**AC CURRENT (Typ.)**|0.88A/115VAC 0.48A/230VAC||||||| |||**INRUSH CURRENT (Typ.)**|COLD START 25A/115VAC 45A/230VAC||||||| |||**OVERLOAD**|105 ~ 160% rated output power<br>H<br>, recovers automatically after fault condition is removed<br>iccup mode when output voltage 50<br><<br>%<br>Constant current limiting<br>recovers automatically after fault condition is removed<br>���������������������������������||||||| |||**OVER VOLTAGE**|Protection type : Shut down o/p voltage, re-power on to recover<br>5 75<br>7.5<br>. ~ V<br>1 ~ 1 V<br>5<br>8<br>18.8 ~ 22.5V<br>30 ~ 36V<br>5 . ~ 6 . V<br>7 6<br>7 2||||||| |||**WORKING TEMP.**|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃||||||| |||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing||||||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃||||||| |||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>) RH non-condensing||||||| |||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6||||||| |||**OPERATING ALTITUDE**|2000 meters||||||| |||**OVER VOLTAGE CATEGORY**|According to E 61558, EN50178,EN60664-1, EN62477-1 altitude up to 2000<br>;<br>;<br>N<br>meters<br>Ⅲ||||||| |||**SAFETY STANDARDS**|UL62368-1, U 508, TUV<br>EN61558-2-16<br>,IEC62368-1,<br>, BSMI CNS15598-1 a<br>BS EN/<br>L<br>,<br>pproved;<br>BS EN/EN61558-1<br>EAC TP TC 004<br>Design refer to TUV<br>EN62368-1<br>BS EN/||||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:4KVAC<br>||||||| |||**MTBF**<br>**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**DIMENSION**|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||||| ||||**Parameter**||**Standard**|||**Test Level / Note**|| ||||Conducted||BS EN/EN55032(CISPR32), CNS15936|||Class B|| ||||Radiated||BS EN/EN55032(CISPR32), CNS15936|||Class B|| ||||Harmonic Current||BS EN/EN61000-3-2|||Class A|| ||||Voltage Flicker||BS EN/EN61000-3-3|||-------|| ||||BS EN/<br>BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2,<br>EN61204-3||||||| ||||**Parameter**||**Standard**|||**Test Level /Note**|| ||||ESD||EN61000-4-2<br>BS EN/|||Level 3, 8KV air; Level 2, 4KV contact, criteria A|| ||||Radiated Susceptibility||EN61000-4-3<br>BS EN/|||Level 3, criteria A|| ||||EFT/Burest||EN61000-4-4<br>BS EN/|||Level 3, criteria A|| ||||Surge||EN61000-4-5<br>BS EN/|||Level 4,2KV/L-N, criteria A|| ||||Conducted||EN61000-4-6<br>BS EN/|||Level 3, criteria A|| ||||Magnetic Field||EN61000-4-8<br>BS EN/|||Level 4, criteria A|| ||||Voltage Dips and interruptions||EN61000-4-11<br>BS EN/|||><br>.<br>95% dip 0 5 periods, 30% dip 25 periods,<br>95% interruptions 250 periods<br>>|| ||||3670.4K hrs min.<br>Telcordia SR-332 (Bellcore) ; 968.1K hrs min. MIL-HDBK-217F (25<br>)<br>℃||||||| ||||35*90*54.5mm (W*H*D)||||||| |||**PACKING**|0.13Kg 96pcs/14.2Kg/1.04CUFT<br>;||||||| |||1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>μ<br>μ<br>F<br>F<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC<br>directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>※Product Liability Disclaimer<br>For detailed information, please refer to<br>:|||||||| _File Name:HDR-30-SPEC 2024-03-11_ **- HDR 30 series** ## 30W Ultra Slim Step Shape DIN Rail **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>RECTIFIERS RECTIFIERS<br>EMI POWER +V<br>I/P & &<br>SWITCHING<br>FILTER -V<br>FILTER FILTER<br>DETECTION<br>CIRCUIT<br>O.L.P. CONTROL<br>O.V.P.<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100<br>90<br>80<br>80<br>60 70<br>50<br>60<br>40<br>50<br>20<br>40<br>-30 0 10 20 30 40 50 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 277<br>(operational)<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:HDR-30-SPEC 2024-03-11_ **- HDR 30 series** 30W Ultra Slim Step Shape DIN Rail ## **Mechanical Specification** ( Unit: mm , tolerance ± 0.5mm) **==> picture [345 x 238] intentionally omitted <==** **----- Start of picture text -----**<br> 58.4<br>35<br>54.5<br>2 1<br>4 3<br>90 63.65 45.15<br>**----- End of picture text -----**<br> **==> picture [5 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 35<br>**----- End of picture text -----**<br> ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Terminal Pin No. Assignment |Pin No.|<br>Assignment|Pin No.<br>Assignment| |---|---|---| |1|+V|3<br>AC/L| |2|-V|4<br>AC/N| ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:HDR-30-SPEC 2024-03-11_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →