- Manufacturer: LEM
- Product type: Current Sensors
- SVHC: No SVHC (25-Jun-2025)
- Accuracy: ± 1%
- Product Range: HAT Series
- Primary Current: 1.5kA
- Sensor Mounting: Panel Mount
- Measured Current: AC / DC / Pulsed
- Sensor Output Type: Analogue
- Supply Voltage Range: ± 15V
- Secondary Signal Type: -4V to 4V
- Current Sensor Technology: Open Loop Hall Effect
- Operating Temperature Max: 105°C
- Operating Temperature Min: -40°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 90.34 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Current Transducer HAT 200 ... 1500-S** For the electronic measurement of currents: DC, AC, pulsed,..., with galvanic separation between the primary circuit and the secondary circuit. _I_ **= 200 ... 1500 A** P N _U_ **= ±4 V** out ## ~~**Electrical data** CO~~ |~~**Electrical data**~~<br>~~CO~~|~~**Electrical data**~~<br>~~CO~~|~~**Electrical data**~~<br>~~CO~~| |---|---|---| |Type<br>Primary nominal<br>Primary current,<br>RoHS since||| |RMS current<br>measuring range1)||date code| |_I_P N(A)<br>_I_P M(A)||| |HAT 200-S<br>200<br>±600||47143| |HAT 400-S<br>400<br>±1200<br>HAT 500-S<br>500<br>±1500||46115<br>46129| |HAT 600-S<br>600<br>±1800<br>HAT 800-S<br>800<br>±2400<br>HAT 1000-S<br>1000<br>±2500<br>HAT 1200-S<br>1200<br>±2500||46115<br>46115<br>46097<br>77271| |HAT 1500-S<br>1500<br>±2500||46158| |_U_C<br>Supply voltage (±5 %)1)<br>_I_C<br>Current consumption<br>_R_INS<br>Insulation resistance @ 500 V DC<br>_U_out<br>Output voltage (Analog) @ ±_I_P N,_R_L= 10 kΩ,_T_A= 25 °C<br>_R_out<br>Output internal resistance<br>_R_L<br>Load resistance<br>~~**Accuracy - Dynamic performance data**~~<br>~~|~~|±15<br>V<br>±20<br>mA<br>> 1000<br>MΩ<br>±4<br>V<br>100<br>Ω<br>> 10<br>kΩ<br>~~|~~|| |_ε_<br>Error @_I_P N,_T_A= 25 °C (excluding offset)|≤ ±1|% of_I_P N| |_ε_L<br>Linearity error2)(0 ... ±_I_P N)<br>_U_O E<br>Electrical offset voltage @_T_A= 25 °C<br>_U_O H<br>Hysteresis offset voltage @_I_P= 0,<br>after an excursion of 1 x_I_P N< ±10<br>_TCU_O ETemperature coefficient of_U_O E<br>−40 °C ... +80 °C<br>+80 °C ... +105 °C < ±1.5<br>_TCU_out Temperature coefficient of_U_out(% of reading)<br>_t_D 90<br>Delay time3)to 90 % of_I_P N<br>_BW_<br>Frequency bandwidth4)(−3 dB)|≤ ±1<br>< ±20<br>< ±10<br>< ±1<br>+80 °C ... +105 °C < ±1.5<br>< ±0.1<br>< 5<br>DC ... 25|% of_I_P N<br>< ±20<br>mV<br>< ±10<br>mV<br>mV/K<br>+80 °C ... +105 °C < ±1.5<br>mV/K<br>< ±0.1<br>%/K<br>µs<br>DC ... 25<br>kHz| ## ~~**Accuracy - Dynamic performance data** |~~ |~~**General data**~~<br>~~PO~~|~~**General data**~~<br>~~PO~~|~~**General data**~~<br>~~PO~~|~~**General data**~~<br>~~PO~~| |---|---|---|---| |_T_A|Ambient operating temperature|−40 ... +105|°C| |_T_S|Ambient storage temperature|−40 ... +105|°C| |_m_|Mass|300|g| ||Standards|EN 50178: 1997|| |||UL 508: 20105)|| Notes:[1) ] Operating at ±12 V ≤ _U_ C < ±15 V will reduce the measuring range 2) Linearity data exclude the electrical offset ## **Features** - ●Hall effect measuring principle - ●Insulating plastic case recognized according to UL 94-V0. ## **Advantages** - ●Easy installation - ●Low power consumption - ●Small size and space saving - ●Only one design for wide current ratings range - ●High immunity to external interference. ## **Applications** - ●DC motor drives - ●Switched Mode Power Supplies (SMPS) - ●AC variable speed drives - ●Uninterruptible Power Supplies (UPS) - ●Battery supplied applications - ●Power supplies for welding applications. ## **Application domain** - ●Industrial. > 3) For a d _i_ / d _t_ = 50 A/µs. 4) Please refer to derating curves in the technical file to avoid excessive core heating at high frequency - 5) UL conform is only applicable @ _T_ A = −40 °C ... +85 °C. N° 74.02.44.000.0, N° 74.02.48.000.0, N° 74.02.50.000.0, N° 74.02.52.000.0 N° 74.02.56.000.0, N° 74.02.60.000.0, N° 74.02.62.000.0, N° 74.02.65.000.0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 1/3 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com 27May2019/version 23 ## **Current Transducer HAT 200 ... 1500-S** ## ~~**Insulation coordination**~~ |_U_d|RMS voltage for AC insulation test, 50 Hz, 1 min|4.9|kV| |---|---|---|---| |_U_Ni|Impulse withstand voltage 1.2/50 µs|> 9.9|kV| |||Min|| |_d_Cp|Creepage distance|11|mm| |_d_CI|Clearance|11|mm| |_CTI_|Comparative tracking index (group IIIa)|275|| ## **Applications examples** **According to EN 50178 and IEC 61010-1 standards** and following conditions: - ●Over voltage category III - ●Pollution degree PD2 - ●Non-uniform field ||**EN 50178**|**IEC 61010-1**| |---|---|---| |_d_Cp,_d_CI,_U_Ni|Rated insulation voltage|Nominal voltage| |Basic insulation|1100 V|1100 V| |Reinforced insulation|550 V|550 V| ## **Safety** This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 27May2019/version 23 **Dimensions HAT 200 ... 1500-S** (in mm) **==> picture [511 x 373] intentionally omitted <==** **----- Start of picture text -----**<br> Connection<br>I P U C<br>R M<br>U C<br>d CI d Cp<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** - ●General tolerance - ●Transducer fastening - ●Connection of secondary ±1 mm By base-plate or on busbar with M4 screws All holes ⌀ 4.5 mm Molex 5045-04A ## **Remarks** - _U_ out is positive when _I_ P flows in the direction of the arrow. - ●Temperature of the primary conductor should not exceed 105 °C. - ●Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to - LEM document N°ANE120504 available on our Web site: . - **https://www.lem.com/en/file/3137/download/** Page 3/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice 27May2019/version 23 LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →