Image not available
Illustrative purposes only
GST18A12-P1J
AC/DC Power Supply, ITE, 1 Output, 18 W, 12 VDC, 1.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC External Plug In Adaptor Power Supplies
- No. of Outputs:1 Output; Output Power Max:18W; Output Voltage - Output 1:12V; Output Current - Output 1:1.5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Connector:Barrel P
- SVHC: No SVHC (25-Jun-2025)
- Plug Type: -
- Product Range: GST18A Series
- No. of Outputs: 1 Output
- Output Connector: Barrel Plug Center Positive 2.1mm x 5.5mm x 11mm
- Output Power Max: 18W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 14.25 € |
| Current stock | 100+ |
| Lead time | 30 days |
> 18W AC-DC High Reliability Industrial Adaptor **GST18A series**
Ⅰ
**==> picture [512 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
THOMAS SAMUEL THOMAS SAMUEL<br>(optional)<br>(3) (CH @s wigter B e S & @ Ao S CBFECE<br>■ ■<br>**----- End of picture text -----**<br>
Ⅰ
℃
## ■
**==> picture [13 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
■<br>**----- End of picture text -----**<br>
× ×
{
_File Name:GST18A-SPEC 2016-12-07_
**GST18A series**
18W AC-DC High Reliability Industrial Adaptor
## **SPECIFICATION**
|**ORDER NO.**<br>**SAFETY MODEL NO.**<br>**DC VOLTAGE**<br>**Note.2**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER (max.)**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**SETUP, RISE, HOLD UP TIME**<br>**VOLTAGE RANGE**<br>**Note.7**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (max.)**<br>**LEAKAGE CURRENT(max.)**<br>**SAFETY STANDARDS Note. 8**<br>**SAFETY &**<br>**EMC**<br>**(Note. 9)**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>5V<br>7.5V<br>9V<br>12V<br>15V<br>18V<br>24V<br>28V<br>48V<br>GST18A05<br>**GST18A05-P1J**<br>**GST18A09-P1J**<br>**GST18A15-P1J**<br>**GST18A24-P1J**<br>**GST18A48-P1J**<br>**GST18A07-P1J**<br>**GST18A12-P1J**<br>**GST18A18-P1J**<br>**GST18A28-P1J**<br>GST18A07<br>GST18A09<br>GST18A12<br>GST18A15<br>GST18A18<br>GST18A24<br>GST18A28<br>GST18A48<br>3.0A<br>2.0A<br>2.0A<br>1.50A<br>1.20A<br>1.0A<br>0.75A<br>0.64A<br>0.375A<br>0 ~ 3.0A<br>0 ~ 2.0A<br>0 ~2.0A<br>0 ~ 1.20A<br>0 ~ 1.0A<br>80mVp-p<br>80mVp-p<br>80mVp-p<br>100mVp-p<br>150mVp-p<br>180mVp-p<br>240mVp-p<br>240mVp-p<br>**VOLTAGE TOLERANCE Note.4**<br>**LINE REGULATION**<br>**Note.5**<br>**LOAD REGULATION**<br>**Note.6**<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>47 ~ 63Hz<br>0.75mA / 240VAC<br>UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336<br>,<br>,<br>AS/NZS 60950.1<br>, CCC GB4943, PSE J60950-1<br>BIS IS13252,<br>KC K60950-1,EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) approved<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:4242VDC , I/P-FG:2121VDC<br>I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>500Khrs min. MIL-HDBK-217F(25<br>)<br>℃<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20% ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>93*54*36mm (L*W*H)<br>209g; 60pcs/13.5Kg/1.12CUFT<br>**CONNECTOR**<br>**PLUG**<br>**CABLE**<br>See page 3 ; Other type available by customer requested<br>See page 3 ; Other type available by customer requested<br>15W<br>15W<br>18W<br>18W<br>0 ~ 1.50A<br>18W<br>18W<br>18W<br>0 ~ 0.75A<br>18W<br>0 ~ 0.64A<br>18W<br>0 ~ 0.375A<br>℃<br>Compliance to EN55022<br>EN61000-3-2,3<br>class B<br>, FCC PART 15 / CISPR22 class B, CAN ICES-3(B)/NMB-3(B),CNS13438 class B<br>,<br>,<br>GB9254, GB17625.1, EAC TP TC 020 MSIP KN32<br>,<br>Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, MSIP KN35<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>110 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Clamp by zener diode, output short<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>80mVp-p<br>85 ~ 264VAC<br>0.5A / 115VAC 0.3A / 230VAC<br>35A / 115VAC 65A / 230VAC<br>110 ~ 140% rated output voltage<br>1000ms, 30ms, 50ms/230VAC 1500ms, 30ms, 15ms/115VAC at full load<br>81%<br>85%<br>85%<br>86%<br>87%<br>88%<br>88%<br>88.5%<br>89%<br>~~|==========~~<br>~~=—S—SSS===~~<br>——————————————<br>Rs~~G~~<br>a<br>re<br>a<br>a<br>~~LC~~<br>1.All parameters are specified at230VAC input, rated load, 25<br>70% RH ambient.<br>2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.<br>3.Ripple & noise are measured at20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.<br>4.Tolerance: includes set up tolerance, line regulation, load regulation.<br>5.Line regulation is measured from low line to high line at rated load.<br>6.Load regulation is measured from 10% to 100% rated load.<br>7.Derating may be needed under low input voltage. Please check the derating curve for more details.<br>8.The demand for Malaysia safety is processed with the order no. GST18A| -SIRIM by request. Please contact MEAN WELL for details.<br>9.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)|**ORDER NO.**<br>**SAFETY MODEL NO.**<br>**DC VOLTAGE**<br>**Note.2**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER (max.)**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**SETUP, RISE, HOLD UP TIME**<br>**VOLTAGE RANGE**<br>**Note.7**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (max.)**<br>**LEAKAGE CURRENT(max.)**<br>**SAFETY STANDARDS Note. 8**<br>**SAFETY &**<br>**EMC**<br>**(Note. 9)**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>5V<br>7.5V<br>9V<br>12V<br>15V<br>18V<br>24V<br>28V<br>48V<br>GST18A05<br>**GST18A05-P1J**<br>**GST18A09-P1J**<br>**GST18A15-P1J**<br>**GST18A24-P1J**<br>**GST18A48-P1J**<br>**GST18A07-P1J**<br>**GST18A12-P1J**<br>**GST18A18-P1J**<br>**GST18A28-P1J**<br>GST18A07<br>GST18A09<br>GST18A12<br>GST18A15<br>GST18A18<br>GST18A24<br>GST18A28<br>GST18A48<br>3.0A<br>2.0A<br>2.0A<br>1.50A<br>1.20A<br>1.0A<br>0.75A<br>0.64A<br>0.375A<br>0 ~ 3.0A<br>0 ~ 2.0A<br>0 ~2.0A<br>0 ~ 1.20A<br>0 ~ 1.0A<br>80mVp-p<br>80mVp-p<br>80mVp-p<br>100mVp-p<br>150mVp-p<br>180mVp-p<br>240mVp-p<br>240mVp-p<br>**VOLTAGE TOLERANCE Note.4**<br>**LINE REGULATION**<br>**Note.5**<br>**LOAD REGULATION**<br>**Note.6**<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>47 ~ 63Hz<br>0.75mA / 240VAC<br>UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336<br>,<br>,<br>AS/NZS 60950.1<br>, CCC GB4943, PSE J60950-1<br>BIS IS13252,<br>KC K60950-1,EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) approved<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:4242VDC , I/P-FG:2121VDC<br>I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>500Khrs min. MIL-HDBK-217F(25<br>)<br>℃<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20% ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>93*54*36mm (L*W*H)<br>209g; 60pcs/13.5Kg/1.12CUFT<br>**CONNECTOR**<br>**PLUG**<br>**CABLE**<br>See page 3 ; Other type available by customer requested<br>See page 3 ; Other type available by customer requested<br>15W<br>15W<br>18W<br>18W<br>0 ~ 1.50A<br>18W<br>18W<br>18W<br>0 ~ 0.75A<br>18W<br>0 ~ 0.64A<br>18W<br>0 ~ 0.375A<br>℃<br>Compliance to EN55022<br>EN61000-3-2,3<br>class B<br>, FCC PART 15 / CISPR22 class B, CAN ICES-3(B)/NMB-3(B),CNS13438 class B<br>,<br>,<br>GB9254, GB17625.1, EAC TP TC 020 MSIP KN32<br>,<br>Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, MSIP KN35<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>110 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Clamp by zener diode, output short<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>80mVp-p<br>85 ~ 264VAC<br>0.5A / 115VAC 0.3A / 230VAC<br>35A / 115VAC 65A / 230VAC<br>110 ~ 140% rated output voltage<br>1000ms, 30ms, 50ms/230VAC 1500ms, 30ms, 15ms/115VAC at full load<br>81%<br>85%<br>85%<br>86%<br>87%<br>88%<br>88%<br>88.5%<br>89%<br>~~|==========~~<br>~~=—S—SSS===~~<br>——————————————<br>Rs~~G~~<br>a<br>re<br>a<br>a<br>~~LC~~<br>1.All parameters are specified at230VAC input, rated load, 25<br>70% RH ambient.<br>2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.<br>3.Ripple & noise are measured at20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.<br>4.Tolerance: includes set up tolerance, line regulation, load regulation.<br>5.Line regulation is measured from low line to high line at rated load.<br>6.Load regulation is measured from 10% to 100% rated load.<br>7.Derating may be needed under low input voltage. Please check the derating curve for more details.<br>8.The demand for Malaysia safety is processed with the order no. GST18A| -SIRIM by request. Please contact MEAN WELL for details.<br>9.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)|**GST18A05-P1J**<br>**GST18A09-P1J**<br>**GST18A15-P1J**<br>**GST18A24-P1J**<br>**GST18A48-P1J**<br>**GST18A07-P1J**<br>**GST18A12-P1J**<br>**GST18A18-P1J**<br>**GST18A28-P1J**<br>~~|==========~~|
|---|---|---|
||**SAFETY MODEL NO.**<br>~~|==========~~|GST18A05<br>GST18A07<br>GST18A09<br>GST18A12<br>GST18A15<br>GST18A18<br>GST18A24<br>GST18A28<br>GST18A48<br>~~|==========~~|
||**DC VOLTAGE**<br>**Note.2**<br>~~|==========~~|5V<br>7.5V<br>9V<br>12V<br>15V<br>18V<br>24V<br>28V<br>48V<br>~~|==========~~|
||**RATED CURRENT**<br>~~|==========~~|3.0A<br>2.0A<br>2.0A<br>1.50A<br>1.20A<br>1.0A<br>0.75A<br>0.64A<br>0.375A<br>~~|==========~~|
||**CURRENT RANGE**<br>~~|==========~~|0 ~ 3.0A<br>0 ~ 2.0A<br>0 ~2.0A<br>0 ~ 1.20A<br>0 ~ 1.0A<br>0 ~ 1.50A<br>0 ~ 0.75A<br>0 ~ 0.64A<br>0 ~ 0.375A<br>~~|==========~~|
||**RATED POWER (max.)**<br>~~|==========~~|15W<br>15W<br>18W<br>18W<br>18W<br>18W<br>18W<br>18W<br>18W<br>~~|==========~~|
||**RIPPLE & NOISE (max.) Note.3**<br>~~|==========~~|80mVp-p<br>80mVp-p<br>80mVp-p<br>100mVp-p<br>150mVp-p<br>180mVp-p<br>240mVp-p<br>240mVp-p<br>80mVp-p<br>~~|==========~~|
||**VOLTAGE TOLERANCE Note.4**<br>~~|==========~~|±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>~~|==========~~|
||**LINE REGULATION**<br>**Note.5**<br>~~|==========~~|±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>~~|==========~~|
||**LOAD REGULATION**<br>**Note.6**<br>~~|==========~~|±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%<br>±2.0%<br>~~|==========~~|
||**SETUP, RISE, HOLD UP TIME**<br>~~|==========~~<br>~~=—S—SSS===~~|1000ms, 30ms, 50ms/230VAC 1500ms, 30ms, 15ms/115VAC at full load<br>~~|==========~~<br>~~=—S—SSS===~~|
||**VOLTAGE RANGE**<br>**Note.7**<br>~~|==========~~<br>~~=—S—SSS===~~|85 ~ 264VAC<br>~~|==========~~<br>~~=—S—SSS===~~|
||**FREQUENCY RANGE**<br>~~=—S—SSS===~~|47 ~ 63Hz<br>~~=—S—SSS===~~|
||**EFFICIENCY (Typ.)**<br>~~=—S—SSS===~~|81%<br>85%<br>85%<br>86%<br>87%<br>88%<br>88%<br>88.5%<br>89%<br>~~=—S—SSS===~~|
||**AC CURRENT**<br>~~=—S—SSS===~~|0.5A / 115VAC 0.3A / 230VAC<br>~~=—S—SSS===~~|
||**INRUSH CURRENT (max.)**<br>~~=—S—SSS===~~|35A / 115VAC 65A / 230VAC<br>~~=—S—SSS===~~|
||**LEAKAGE CURRENT(max.)**<br>~~=—S—SSS===~~<br>—————————————|0.75mA / 240VAC<br>~~=—S—SSS===~~<br>—————————————|
||**OVERLOAD**<br>~~=—S—SSS===~~<br>—————————————|110 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>~~=—S—SSS===~~<br>—————————————|
||**OVER VOLTAGE**<br>—————————————|Protection type : Clamp by zener diode, output short<br>110 ~ 140% rated output voltage<br>—————————————|
||**WORKING TEMP.**<br>—————————————<br>Rs|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>—————————————<br>~~G~~|
||**WORKING HUMIDITY**<br>Rs<br>a|20% ~ 90% RH non-condensing<br>~~G~~|
||**STORAGE TEMP., HUMIDITY**<br>Rs<br>a|-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>~~G~~|
||**TEMP. COEFFICIENT**<br>a|±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)|
||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes|
||**SAFETY STANDARDS Note. 8**<br>re|UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336<br>,<br>,<br>AS/NZS 60950.1<br>, CCC GB4943, PSE J60950-1<br>BIS IS13252,<br>KC K60950-1,EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) approved|
||**WITHSTAND VOLTAGE**<br>re|I/P-O/P:4242VDC , I/P-FG:2121VDC|
||**ISOLATION RESISTANCE**<br>re|I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|
||**EMC EMISSION**|Compliance to EN55022<br>EN61000-3-2,3<br>class B<br>, FCC PART 15 / CISPR22 class B, CAN ICES-3(B)/NMB-3(B),CNS13438 class B<br>,<br>,<br>GB9254, GB17625.1, EAC TP TC 020 MSIP KN32<br>,|
||**EMC IMMUNITY**<br>a|Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, MSIP KN35|
||**MTBF**<br>a<br>a|500Khrs min. MIL-HDBK-217F(25<br>)<br>℃|
||**DIMENSION**|93*54*36mm (L*W*H)|
||**PACKING**<br>~~LC~~|209g; 60pcs/13.5Kg/1.12CUFT<br>~~LC~~|
||**PLUG**|See page 3 ; Other type available by customer requested|
||**CABLE**|See page 3 ; Other type available by customer requested|
||℃<br>1.All parameters are specified at230VAC input, rated load, 25<br>70% RH ambient.<br>2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.<br>3.Ripple & noise are measured at20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.<br>4.Tolerance: includes set up tolerance, line regulation, load regulation.<br>5.Line regulation is measured from low line to high line at rated load.<br>6.Load regulation is measured from 10% to 100% rated load.<br>7.Derating may be needed under low input voltage. Please check the derating curve for more details.<br>8.The demand for Malaysia safety is processed with the order no. GST18A| -SIRIM by request. Please contact MEAN WELL for details.<br>9.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)||
_File Name:GST18A-SPEC 2016-12-07_
**GST18A series**
## 18W AC-DC High Reliability Industrial Adaptor
**==> picture [511 x 668] intentionally omitted <==**
**----- Start of picture text -----**<br>
Derating Curve Static Characteristics<br>100<br>85<br>100<br>80<br>70<br>50 60<br>50<br>40<br>-30 10 20 30 40 50 60 70 85 95 100 110 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>Mechanical Specification Unit:mm<br>UL1185 16AWG 1200±50mm for 5~12V<br>UL1185 18AWG 1800±50mm for 15~48V<br>70±10mm<br>POWER LED C"+"<br>11±0.5mm<br>ID 2.1 x OD 5.5<br>Outside Inside<br>NAME PLATE<br>-V not connected to AC FG<br>Plug Assignment<br>93 36<br>Standard plug: P1J<br>P1J<br>P/N OUTPUT<br>CENTER +<br>Installation Manual<br>Please refer to : http://www.meanwell.com/manual.html<br>LOAD (%) LOAD (%)<br>54<br>**----- End of picture text -----**<br>
_File Name:GST18A-SPEC 2016-12-07_
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →