Image not available
Illustrative purposes only
GSM12E15-P1J
AC/DC Power Supply, Medical, 1 Output, 12 W, 15 VDC, 800 mA
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC External Plug In Adaptor Power Supplies
- SVHC: No SVHC (12-Jan-2017)
- Plug Type: EU
- Product Range: GSM12E Series
- No. of Outputs: 1 Output
- Output Connector: Barrel Plug Center Positive 2.1mm x 5.5mm x 11mm
- Output Power Max: 12W
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 800mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 15VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 14.27 € |
| Current stock | 10+ |
| Lead time | 30 days |
**GSM12E series**
12W AC-DC Reliable Green Medical Adaptor
**==> picture [113 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
( Cable connection )<br>**----- End of picture text -----**<br>
## ( USB connection )
**==> picture [397 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
IP22 + +<br>•■ UniversalFeaturesAC input/ Full range •■ Applicati<br>•<br>EN60601-1/EN60601-1-11Medical safety approved (2 x MOPP) accroding to •• BloodBlood glucose<br>•<br>Extremely low leakage current • Nebulizer<br>• No load power consumption< 0.075W__0.1W (< for 18V/48V) Inhaler<br>•<br>• Energy efficiency- Level Ⅵ Portable<br>•<br>• -20~+70 ℃ wide range working temperature Sleep apnea<br>• Class Ⅱ power (no earth pin)<br>• Protections: Short circuit / Overload / Over voltage<br>• Fully enclosed plastic case<br>•<br>**----- End of picture text -----**<br>
**==> picture [13 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
■<br>**----- End of picture text -----**<br>
**==> picture [68 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ⅱ<br>the demands<br>medical<br>devices in<br>working<br>(< 0.1W for<br>**----- End of picture text -----**<br>
**==> picture [13 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
■<br>**----- End of picture text -----**<br>
## {
ψ× ψ×
_File Name:GSM12E-SPEC 2018-09-28_
**GSM12E series**
12W AC-DC Reliable Green Medical Adaptor
## **SPECIFICATION**
|**SPECIFICATION**|**SPECIFICATION**||||
|---|---|---|---|---|
|**ORDER NO.**<br>**SAFETY MODEL NO.**<br>**DC VOLTAGE**<br>**Note.2**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER (max.)**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**SETUP, RISE, HOLD UP TIME**<br>**VOLTAGE RANGE**<br>**Note.7**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (max.)**<br>**LEAKAGE CURRENT(max.)**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**LIFE**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>5V<br>9V<br>7.5V<br>12V<br>15V<br>18V<br>24V<br>48V<br>GSM12E05<br>GSM12E07<br>GSM12E09<br>GSM12E12<br>GSM12E15<br>GSM12E18<br>GSM12E24<br>GSM12E48<br>**GSM12E07-P1J GSM12E09-P1J GSM12E12-P1J GSM12E15-P1J GSM12E18-P1J GSM12E24-P1J GSM12E48-P1J**<br>2.4A<br>1.33A<br>1.6A<br>1A<br>0.8A<br>0.66A<br>0.5A<br>0.25A<br>0 ~ 2.4A<br>0 ~ 1.33A<br>0 ~ 1.6A<br>0 ~ 1A<br>0 ~ 0.8A<br>0 ~ 0.66A<br>0 ~ 0.5A<br>60mVp-p<br>60mVp-p<br>60mVp-p<br>80mVp-p<br>80mVp-p<br>80mVp-p<br>80mVp-p<br>100mVp-p<br>**VOLTAGE TOLERANCE Note.4**<br>**LINE REGULATION**<br>**Note.5**<br>**LOAD REGULATION**<br>**Note.6**<br>±5.0%<br>±4.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±5.0%<br>±4.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>0.4A / 115VAC 0.2A / 230VAC<br>**WITHSTAND VOLTAGE**<br>I/P-O/P:5656VDC<br>TUV EN60601-1/EN60601-1-11 (3.1 version),<br>approved<br>EAC TP TC 004<br>GSM12E05-USB without EN60601-1-11<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>3 years : 100% load 40<br>, 12hours / day<br>℃<br>400Khrs min. MIL-HDBK-217F(25<br>)<br>℃<br>-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20% ~ 90% RH non-condensing<br>-20 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03% /<br>(0 ~ 40<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>62.2*27.4*39.7mm (L*W*H)<br>**CONNECTOR**<br>**PLUG**<br>**CABLE**<br>12W<br>12W<br>12W<br>12W<br>12W<br>12W<br>12W<br>12W<br>0 ~ 0.25A<br>℃<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>110 ~ 200% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>110 ~ 140% rated output voltage<br>Protection type : Clamp by zener diode, output short<br>500ms, 30ms, 16ms/230VAC 500ms, 30ms, 16ms/115VAC at full load<br>80%<br>82%<br>82%<br>82.5%<br>84%<br>85%<br>85%<br>87%<br>See page 4 5 ; other type available by customer requested<br>~<br>100g, 90pcs / 10kg / CARTON for cable connection ; 76g, 150pcs / 12.5kg / CARTON for USB connection<br>See page 4 5 ; other type available by customer requested<br>~<br>Touch current <<br>0 A/264VAC<br>10 μ<br>Level 3, 10V/m(80MHz~2.7GHz)<br>Table 9, 9~28V/m(385MHz~5.78GHz)<br>**GSM12E05-**<br>**=P1J**<br>**USB**<br>**SAFETY &**<br>**EMC**<br>**(Note. 8)**<br>**ISOLATION RESISTANCE**<br>**Parameter**<br>**Parameter**<br>ESD<br>**Standard**<br>**Standard**<br>EN61000-3-2<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55024 , EN60601-1-2, EN61204-3<br>Level 4, 15KV air ; Level 4, 8KV contact<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Level 3, 1KV/Line-Line<br>Level 4, 30A/m<br>Level 2, 3V<br>Level 3, 2KV<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Conductedemission<br>Radiated emission<br>Harmonic current<br>Voltage flicker<br>**ISOLATION LEVEL**<br>Pimary - Secondary: 2 x MOPP<br>30A / 115VAC 60A / 230VAC<br>Cold start<br>Re<br>a<br>eee<br>~~LC~~<br>~~Ge~~<br>a<br>~~—————~~<br>1.All parameters are specified at 230VAC input, rated load, 25<br>70% RH ambient.<br>2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.<br>3.Ripple & noise are measured at20MHz by using a 12" twisted pair terminated with a 0.1<br>f & 47<br>f capacitor.<br>4.Tolerance: includes set up tolerance, line regulation, load regulation.<br>5.Line regulation is measured from low line to high line at rated load.<br>6.Load regulation is measured from 10% to 100% rated load.<br>7.Derating may be needed under low input voltage. Please check the derating curve for more details.<br>8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)||**GSM12E07-P1J GSM12E09-P1J GSM12E12-P1J GSM12E15-P1J GSM12E18-P1J GSM12E24-P1J GSM12E48-P1J**<br>**GSM12E05-**<br>**=P1J**<br>**USB**|||
||**SAFETY MODEL NO.**|GSM12E05<br>GSM12E07<br>GSM12E09<br>GSM12E12<br>GSM12E15<br>GSM12E18<br>GSM12E24<br>GSM12E48|||
||**DC VOLTAGE**<br>**Note.2**|5V<br>9V<br>7.5V<br>12V<br>15V<br>18V<br>24V<br>48V|||
||**RATED CURRENT**|2.4A<br>1.33A<br>1.6A<br>1A<br>0.8A<br>0.66A<br>0.5A<br>0.25A|||
||**CURRENT RANGE**|0 ~ 2.4A<br>0 ~ 1.33A<br>0 ~ 1.6A<br>0 ~ 1A<br>0 ~ 0.8A<br>0 ~ 0.66A<br>0 ~ 0.5A<br>0 ~ 0.25A|||
||**RATED POWER (max.)**|12W<br>12W<br>12W<br>12W<br>12W<br>12W<br>12W<br>12W|||
||**RIPPLE & NOISE (max.) Note.3**|60mVp-p<br>60mVp-p<br>60mVp-p<br>80mVp-p<br>80mVp-p<br>80mVp-p<br>80mVp-p<br>100mVp-p|||
||**VOLTAGE TOLERANCE Note.4**|±5.0%<br>±4.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%|||
||**LINE REGULATION**<br>**Note.5**|±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%|||
||**LOAD REGULATION**<br>**Note.6**<br>Re|±5.0%<br>±4.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>±2.0%|||
||**SETUP, RISE, HOLD UP TIME**<br>Re|500ms, 30ms, 16ms/230VAC 500ms, 30ms, 16ms/115VAC at full load|||
||**VOLTAGE RANGE**<br>**Note.7**<br>Re|80 ~ 264VAC 113 ~ 370VDC|||
||**FREQUENCY RANGE**|47 ~ 63Hz|||
||**EFFICIENCY (Typ.)**|80%<br>82%<br>82%<br>82.5%<br>84%<br>85%<br>85%<br>87%|||
||**AC CURRENT**|0.4A / 115VAC 0.2A / 230VAC|||
||**INRUSH CURRENT (max.)**|30A / 115VAC 60A / 230VAC<br>Cold start|||
||**LEAKAGE CURRENT(max.)**|Touch current <<br>0 A/264VAC<br>10 μ|||
||**OVERLOAD**<br>a|110 ~ 200% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>eee|||
||**OVER VOLTAGE**<br>a|110 ~ 140% rated output voltage<br>Protection type : Clamp by zener diode, output short<br>eee|||
||**WORKING TEMP.**<br>a<br>~~LC~~|-20 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>eee<br>~~LC~~|||
||**WORKING HUMIDITY**<br>~~LC~~<br>~~Ge~~|20% ~ 90% RH non-condensing<br>~~LC~~<br>~~Ge~~|||
||**STORAGE TEMP., HUMIDITY**|-20 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||
||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03% /<br>(0 ~ 40<br>)|||
||**VIBRATION**<br>a|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes|||
||**SAFETY STANDARDS**|TUV EN60601-1/EN60601-1-11 (3.1 version),<br>approved<br>EAC TP TC 004<br>GSM12E05-USB without EN60601-1-11|||
||**ISOLATION LEVEL**|Pimary - Secondary: 2 x MOPP|||
||**WITHSTAND VOLTAGE**|I/P-O/P:5656VDC|||
||**ISOLATION RESISTANCE**|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||
||**LIFE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~—————~~|**Parameter**|**Standard**|**Test Level / Note**|
|||Conductedemission|EN55011 (CISPR11)|Class B|
|||Radiated emission|EN55011 (CISPR11)|Class B|
|||Harmonic current|EN61000-3-2|Class A|
|||Voltage flicker|EN61000-3-3|-----|
|||EN55024 , EN60601-1-2, EN61204-3|||
|||**Parameter**|**Standard**|**Test Level / Note**|
|||ESD|EN61000-4-2|Level 4, 15KV air ; Level 4, 8KV contact|
|||RF field susceptibility|EN61000-4-3|Level 3, 10V/m(80MHz~2.7GHz)<br>Table 9, 9~28V/m(385MHz~5.78GHz)|
|||EFT bursts|EN61000-4-4|Level 3, 2KV|
|||Surge susceptibility|EN61000-4-5|Level 3, 1KV/Line-Line|
|||Conducted susceptibility|EN61000-4-6|Level 2, 3V|
|||Magnetic field immunity|EN61000-4-8|Level 4, 30A/m|
|||Voltage dip, interruption<br>~~—————~~|EN61000-4-11<br>~~—————~~|>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|
|||3 years : 100% load 40<br>, 12hours / day<br>℃<br>~~—————~~|||
||**MTBF**<br>~~—————~~|400Khrs min. MIL-HDBK-217F(25<br>)<br>℃<br>~~—————~~|||
||**DIMENSION**<br>~~—————~~|62.2*27.4*39.7mm (L*W*H)<br>~~—————~~|||
||**PACKING**<br>~~—————~~|100g, 90pcs / 10kg / CARTON for cable connection ; 76g, 150pcs / 12.5kg / CARTON for USB connection<br>~~—————~~|||
||**PLUG**<br>~~—————~~|See page 4 5 ; other type available by customer requested<br>~<br>~~—————~~|||
||**CABLE**|See page 4 5 ; other type available by customer requested<br>~|||
||℃<br>1.All parameters are specified at 230VAC input, rated load, 25<br>70% RH ambient.<br>2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.<br>3.Ripple & noise are measured at20MHz by using a 12" twisted pair terminated with a 0.1<br>f & 47<br>f capacitor.<br>4.Tolerance: includes set up tolerance, line regulation, load regulation.<br>5.Line regulation is measured from low line to high line at rated load.<br>6.Load regulation is measured from 10% to 100% rated load.<br>7.Derating may be needed under low input voltage. Please check the derating curve for more details.<br>8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)||||
**NOTE**
_File Name:GSM12E-SPEC 2018-09-28_
**GSM12E series**
12W AC-DC Reliable Green Medical Adaptor
**==> picture [512 x 728] intentionally omitted <==**
**----- Start of picture text -----**<br>
Derating Curve Static Characteristics<br>100<br>90<br>100<br>80<br>70<br>70<br>50 60<br>50<br>40<br>-20 10 20 30 40 50 70 80 100 115 120 130 140 160 180 200 220 240 264<br>Ta ( ℃ ) INPUT VOLTAGE<br>Mechanical Specification Unit:mm<br>※Cable Connection<br>62.2 UL2468 18AWG 1000+150/-0mm for 5~7.5V<br>UL2468 22AWG 1200+150/-0mm for 9V<br>UL2468 24AWG 1800+150/-0mm for 12V~48V<br>2 pole EURO plug<br>※USB Connection<br>62.2<br>USB Type A<br>4 +V<br>3 N.C<br>2 N.C<br>1 -V<br>LOAD (%) LOAD (%)<br>27.4<br>39.7<br>27.4<br>39.7<br>+<br>-<br>**----- End of picture text -----**<br>
_File Name:GSM12E-SPEC 2018-09-28_
**GSM12E series**
12W AC-DC Reliable Green Medical Adaptor
## **DC output plug**
Standard plug: P1J Unit:mm **P1J Pin Assignment** ~~a~~ 5.5 11 ±0.5mm C"+" 2.1 Outside Inside ~~“oe~~ Optional DC plug: A B C Tuning Fork Style Type No. OD ID L ~~a~~ C P1I 5.5 2.1 9.5 P1L 5.5 2.5 9.5 (Straight) P1M 5.5 2.5 11.0 A C P1IR 5.5 2.1 9.5 ‘~™~ ~~6~~ B ~~55ACL~~ P1JR 5.5 2.1 11.0 P1LR 5.5 2.5 9.5 (Right-angled) ~~SS~~ P1MR 5.5 2.5 11.0 ~~———a~~ A B C Barrel Style Type No. ~~pt~~ OD ID L C ~~ee~~ P2I 5.5 ~~ee~~ 2.1 9.5 P2J 5.5 2.1 11.0 P2L 5.5 2.5 9.5 A (Straight) P2M 5.5 2.5 11.0 B C P2IR 5.5 2.1 9.5 R ~~m—~~ P2JR 5.5 2.1 11.0 ~~ee~~ P2LR 5.5 ~~ee~~ 2.5 9.5 (Right-angled) P2MR 5.5 2.5 11.0 ~~fF ——[Ee] ———a~~ A B C Lock Style Type No. OD ID L ~~rr~~ A Locking C P2S ~~ee~~ (S761K) 5.53 2.03 12.06 P2K(761K) 5.53 2.54 12.06 B P2C(S760K) 5.53 2.03 9.52 SWITCHCRAFT original or equivalent P2D(760K) 5.53 2.54 9.52 ~~———a~~ A B C Min. Pin Style Type No. OD ID L ~~rr~~ A C P3A 2.35 0.7 11.0 ~~|~~ P3B 4.0 1.7 11.0 B ~~be~~ EIAJ equivalent P3C 4.75 1.7 11.0
◎ Standard plug: P1J
◎ Optional DC plug:
_File Name:GSM12E-SPEC 2018-09-28_
12W AC-DC Reliable Green Medical Adaptor
## **GSM12E series**
A B C D Center Pin Style Type No. OD ID L Center Pin A C P4A 5.5 3.4 11.0 1.0 ~~r= r~~ h ~~] P~~ P4B 6.5 4.4 11.0 1.4 B ~~ee~~ D EIAJ equivalent ~~ee~~ P4C 7.4 5.1 11.0 0.6 ~~Cre ee~~ Pin Assi ~~ee~~ gnment ~~ee~~ Min. DIN 3 Pin with Lock (male) Type No. ~~eeee~~ PIN No. ~~ee~~ Output 1 +Vo 1 2 R6B 2 -Vo 3 KYCON KPPX-3P equivalent 3 +Vo w ~~e ——~~ Pin Assignment Min. DIN 4 Pin with Lock (male) Type No. ~~ee~~ ee PIN No ~~ee~~ . ~~ee~~ Output 1 +Vo 2 3 2 -Vo R7B 1 4 3 -Vo Xe ~~.~~ KYCON KPPX-4P equivalent ~~ee ee ee~~ 4 +Vo Pin Assignment Stripped and tinned leads Type No. ~~ee~~ PIN No. Output L 1 1 +Vo 2 ( Ribbed ) L1 by customer Length of Land L1 by request 2 -Vo (MW’s standard length, L: 25 mm, L1: 10 mm) ( Letter ) ~~<=] b~~ **Installation Manual** Please refer to : http://www.meanwell.com/manual.html
_File Name:GSM12E-SPEC 2018-09-28_
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →