Image not available
Illustrative purposes only
GSM06E07-P1J
AC/DC Power Supply, Medical, 1 Output, 6 W, 7.5 VDC, 800 mA
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC External Plug In Adaptor Power Supplies
- Available until stocks are exhausted
- SVHC: No SVHC (12-Jan-2017)
- Plug Type: EU
- Product Range: GSM06E Series
- No. of Outputs: 1 Output
- Output Connector: Barrel Plug Center Positive 2.1mm x 5.5mm x 11mm
- Output Power Max: 6W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 800mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 7.5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 11.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
**GSM06E series**
6W AC-DC Reliable Green Medical Adaptor
**==> picture [409 x 198] intentionally omitted <==**
**----- Start of picture text -----**<br>
+ +<br>HAL CE bo) boas<br>■ Features ■ Applications<br>• 2 pole EURO plug , Class Ⅱ —_— power unit • Blood glucose<br>• Medical safety approved (2 x MOPP) accroding to • Blood pressure<br>•<br>EN60601-1 Nebulizer<br>• •<br>Extremely low leakage current Inhaler<br>• •<br>No load power consumption< 0.3W Portable medical<br>• Energy efficiency Level Ⅴ<br>• Protections: Short circuit / Overload / Over voltage<br>• Fully enclosed plastic case<br>•<br>**----- End of picture text -----**<br>
## ■
**==> picture [13 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
■<br>**----- End of picture text -----**<br>
**==> picture [6 x 31] intentionally omitted <==**
**----- Start of picture text -----**<br>
{<br>**----- End of picture text -----**<br>
**==> picture [35 x 6] intentionally omitted <==**
_File Name:GSM06E-SPEC 2018-01-15_
**GSM06E series**
6W AC-DC Reliable Green Medical Adaptor
## **SPECIFICATION**
|**ORDER NO.**<br>**SAFETY MODEL NO.**<br>**DC VOLTAGE**<br>**Note.2**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**SETUP, RISE, HOLD UP TIME**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (max.)**<br>**LEAKAGE CURRENT(max.)**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>5V<br>7.5V<br>6V<br>9V<br>12V<br>15V<br>18V<br>24V<br>GSM06E05<br>GSM06E06<br>GSM06E07<br>GSM06E09<br>GSM06E12<br>GSM06E15<br>GSM06E18<br>GSM06E24<br>1.2A<br>0.8A<br>1A<br>0.66A<br>0.5A<br>0.4A<br>0.33A<br>0.25A<br>0 ~ 1.2A<br>0 ~ 0.8A<br>0 ~ 1A<br>0 ~ 0.66A<br>0 ~ 0.5A<br>0 ~ 0.4A<br>0 ~ 0.33A<br>0 ~ 0.25A<br>6W<br>6W<br>6W<br>6W<br>6W<br>6W<br>6W<br>6W<br>50mVp-p<br>80mVp-p<br>50mVp-p<br>80mVp-p<br>100mVp-p<br>120mVp-p<br>150mVp-p<br>180mVp-p<br>**VOLTAGE TOLERANCE Note.4**<br>**LINE REGULATION**<br>**Note.5**<br>**LOAD REGULATION**<br>**Note.6**<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±4.0%<br>1000ms, 50ms, 12ms at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>68%<br>74%<br>74%<br>76%<br>77%<br>79%<br>80%<br>82%<br>0.18A / 100VAC<br>Cold start 15A/ 115VAC 30A / 230VAC<br>TUV EN60601-1, EN60601-1-11,<br>approved<br>EAC TP TC 004<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:5656VDC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>500Khrs min. MIL-HDBK-217F(25<br>)<br>℃<br>0 ~ +50<br>(Refer to "Derating Curve")<br>℃<br>20% ~ 90% RH non-condensing<br>-20 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.04% /<br>(0 ~ 40<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>32*66*42.5mm (L*W*H)<br>100g ; 90pcs / 10Kg / CARTON<br>**CONNECTOR**<br>**PLUG**<br>**CABLE**<br>See page 4~5 ; Other type available by customer requested<br>See page 4~5 ; Other type available by customer requested<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>110 ~ 140% rated output power<br>>105% rated output power<br>Protection type : Clamp by zener diode<br>**GSM06E05-P1J GSM06E06-P1J GSM06E07-P1J GSM06E09-P1J GSM06E12-P1J GSM06E15-P1J GSM06E18-P1J GSM06E24-P1J**<br>Touch current < 50 A/264VAC<br>μ<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>**VOLTAGE RANGE**<br>℃<br>**SAFETY &**<br>**EMC**<br>**(Note. 7)**<br>**ISOLATION LEVEL**<br>Pimary - Secondary: 2 x MOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>**Standard**<br>**Standard**<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55024 , EN60601-1-2, EN61204-3<br>Level 4, 15KV air ; Level 4, 8KV contact<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Level 3, 10V/m(80MHz~2.7GHz)<br>Table 9, 9~28V/m(385MHz~5.78GHz)<br>Level 3, 1KV/Line-Line<br>Level 4, 30A/m<br>Level 2, 3V<br>Level 3, 2KV<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Conductedemission<br>Radiated emission<br>Harmonic current<br>Voltage flicker<br>Po<br>~~GQ~~<br>~~QC~~<br>~~Re~~<br>Ge<br>Ge<br>GG<br>~~Se~~<br>Ge<br>~~OO~~<br>~~Po~~<br>~~CG~~<br>~~CO~~<br>~~Re~~<br>se ~~GGG~~<br>se eG<br>Po<br>~~a~~<br>a<br>a<br>ee<br>GG<br>~~ee~~<br>a<br>a ~~Ce~~<br>~~|~~<br>Re<br>~~PO~~<br>~~ae~~<br>as<br>a<br>a<br>a<br>a<br>a~~|~~<br>~~ee~~<br>~~GO~~<br>~~GQ~~<br>~~GO~~<br>~~GG~~<br>~~eG~~<br>~~Ce~~<br>~~Ge~~<br>~~GG~~<br>~~GO~~<br>~~GO~~<br>~~De~~<br>~~eG~~<br>es<br>es<br>a<br>a<br>es<br>1.All parameters are specified at230VAC input, rated load, 25<br>70% RH ambient.<br>2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.<br>3.Ripple & noise are measured at20MHz by using a 12" twisted pair terminated with a 0.1<br>f & 47<br>f capacitor.<br>4.Tolerance: includes set up tolerance, line regulation, load regulation.<br>5.Line regulation is measured from low line to high line at rated load.<br>6.Load regulation is measured from 0% to 100% rated load.<br>7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http://www.meanwell.com)|**ORDER NO.**<br>**SAFETY MODEL NO.**<br>**DC VOLTAGE**<br>**Note.2**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**SETUP, RISE, HOLD UP TIME**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (max.)**<br>**LEAKAGE CURRENT(max.)**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>5V<br>7.5V<br>6V<br>9V<br>12V<br>15V<br>18V<br>24V<br>GSM06E05<br>GSM06E06<br>GSM06E07<br>GSM06E09<br>GSM06E12<br>GSM06E15<br>GSM06E18<br>GSM06E24<br>1.2A<br>0.8A<br>1A<br>0.66A<br>0.5A<br>0.4A<br>0.33A<br>0.25A<br>0 ~ 1.2A<br>0 ~ 0.8A<br>0 ~ 1A<br>0 ~ 0.66A<br>0 ~ 0.5A<br>0 ~ 0.4A<br>0 ~ 0.33A<br>0 ~ 0.25A<br>6W<br>6W<br>6W<br>6W<br>6W<br>6W<br>6W<br>6W<br>50mVp-p<br>80mVp-p<br>50mVp-p<br>80mVp-p<br>100mVp-p<br>120mVp-p<br>150mVp-p<br>180mVp-p<br>**VOLTAGE TOLERANCE Note.4**<br>**LINE REGULATION**<br>**Note.5**<br>**LOAD REGULATION**<br>**Note.6**<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±4.0%<br>1000ms, 50ms, 12ms at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>68%<br>74%<br>74%<br>76%<br>77%<br>79%<br>80%<br>82%<br>0.18A / 100VAC<br>Cold start 15A/ 115VAC 30A / 230VAC<br>TUV EN60601-1, EN60601-1-11,<br>approved<br>EAC TP TC 004<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:5656VDC<br>I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>500Khrs min. MIL-HDBK-217F(25<br>)<br>℃<br>0 ~ +50<br>(Refer to "Derating Curve")<br>℃<br>20% ~ 90% RH non-condensing<br>-20 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.04% /<br>(0 ~ 40<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>32*66*42.5mm (L*W*H)<br>100g ; 90pcs / 10Kg / CARTON<br>**CONNECTOR**<br>**PLUG**<br>**CABLE**<br>See page 4~5 ; Other type available by customer requested<br>See page 4~5 ; Other type available by customer requested<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>110 ~ 140% rated output power<br>>105% rated output power<br>Protection type : Clamp by zener diode<br>**GSM06E05-P1J GSM06E06-P1J GSM06E07-P1J GSM06E09-P1J GSM06E12-P1J GSM06E15-P1J GSM06E18-P1J GSM06E24-P1J**<br>Touch current < 50 A/264VAC<br>μ<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>**VOLTAGE RANGE**<br>℃<br>**SAFETY &**<br>**EMC**<br>**(Note. 7)**<br>**ISOLATION LEVEL**<br>Pimary - Secondary: 2 x MOPP<br>**Parameter**<br>**Parameter**<br>ESD<br>**Standard**<br>**Standard**<br>EN55011 (CISPR11)<br>EN55011 (CISPR11)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>Class B<br>Class A<br>-----<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55024 , EN60601-1-2, EN61204-3<br>Level 4, 15KV air ; Level 4, 8KV contact<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Level 3, 10V/m(80MHz~2.7GHz)<br>Table 9, 9~28V/m(385MHz~5.78GHz)<br>Level 3, 1KV/Line-Line<br>Level 4, 30A/m<br>Level 2, 3V<br>Level 3, 2KV<br>RF field susceptibility<br>EFT bursts<br>Surge susceptibility<br>Conducted susceptibility<br>Magnetic field immunity<br>Voltage dip, interruption<br>Conductedemission<br>Radiated emission<br>Harmonic current<br>Voltage flicker<br>Po<br>~~GQ~~<br>~~QC~~<br>~~Re~~<br>Ge<br>Ge<br>GG<br>~~Se~~<br>Ge<br>~~OO~~<br>~~Po~~<br>~~CG~~<br>~~CO~~<br>~~Re~~<br>se ~~GGG~~<br>se eG<br>Po<br>~~a~~<br>a<br>a<br>ee<br>GG<br>~~ee~~<br>a<br>a ~~Ce~~<br>~~|~~<br>Re<br>~~PO~~<br>~~ae~~<br>as<br>a<br>a<br>a<br>a<br>a~~|~~<br>~~ee~~<br>~~GO~~<br>~~GQ~~<br>~~GO~~<br>~~GG~~<br>~~eG~~<br>~~Ce~~<br>~~Ge~~<br>~~GG~~<br>~~GO~~<br>~~GO~~<br>~~De~~<br>~~eG~~<br>es<br>es<br>a<br>a<br>es<br>1.All parameters are specified at230VAC input, rated load, 25<br>70% RH ambient.<br>2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.<br>3.Ripple & noise are measured at20MHz by using a 12" twisted pair terminated with a 0.1<br>f & 47<br>f capacitor.<br>4.Tolerance: includes set up tolerance, line regulation, load regulation.<br>5.Line regulation is measured from low line to high line at rated load.<br>6.Load regulation is measured from 0% to 100% rated load.<br>7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http://www.meanwell.com)|**GSM06E05-P1J GSM06E06-P1J GSM06E07-P1J GSM06E09-P1J GSM06E12-P1J GSM06E15-P1J GSM06E18-P1J GSM06E24-P1J**|**GSM06E05-P1J GSM06E06-P1J GSM06E07-P1J GSM06E09-P1J GSM06E12-P1J GSM06E15-P1J GSM06E18-P1J GSM06E24-P1J**|**GSM06E05-P1J GSM06E06-P1J GSM06E07-P1J GSM06E09-P1J GSM06E12-P1J GSM06E15-P1J GSM06E18-P1J GSM06E24-P1J**|
|---|---|---|---|---|
||**SAFETY MODEL NO.**<br>Po<br>~~Re~~|GSM06E05<br>GSM06E06<br>GSM06E07<br>GSM06E09<br>GSM06E12<br>GSM06E15<br>GSM06E18<br>GSM06E24<br>~~QC~~|||
||**DC VOLTAGE**<br>**Note.2**<br>Po<br>~~GQ~~<br>~~Re~~|5V<br>7.5V<br>6V<br>9V<br>12V<br>15V<br>18V<br>24V<br>~~GQ~~<br>~~QC~~<br>Ge<br>Ge<br>GG|||
||**RATED CURRENT**<br>~~GQ~~<br>~~Re~~<br>~~Po~~|1.2A<br>0.8A<br>1A<br>0.66A<br>0.5A<br>0.4A<br>0.33A<br>0.25A<br>~~GQ~~<br>~~QC~~<br>Ge<br>Ge<br>GG<br>Ge<br>~~OO~~|||
||**CURRENT RANGE**<br>~~Re~~<br>~~Se~~<br>~~Po~~|0 ~ 1.2A<br>0 ~ 0.8A<br>0 ~ 1A<br>0 ~ 0.66A<br>0 ~ 0.5A<br>0 ~ 0.4A<br>0 ~ 0.33A<br>0 ~ 0.25A<br>~~QC~~<br>Ge<br>Ge<br>GG<br>~~Se~~<br>Ge<br>~~OO~~|||
||**RATED POWER**<br>~~Se~~<br>~~Po~~<br>~~Re~~|6W<br>6W<br>6W<br>6W<br>6W<br>6W<br>6W<br>6W<br>~~Se~~<br>Ge<br>~~OO~~<br>~~CO~~|||
||**RIPPLE & NOISE (max.) Note.3**<br>~~Po~~<br>~~CG~~<br>~~Re~~|50mVp-p<br>80mVp-p<br>50mVp-p<br>80mVp-p<br>100mVp-p<br>120mVp-p<br>150mVp-p<br>180mVp-p<br>Ge<br>~~OO~~<br>~~CG~~<br>~~CO~~|||
||**VOLTAGE TOLERANCE Note.4**<br>~~CG~~<br>~~Re~~|±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±4.0%<br>~~CG~~<br>~~CO~~<br>se~~GGG~~|||
||**LINE REGULATION**<br>**Note.5**<br>~~Re~~<br>Po<br>~~a~~|±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>±0.5%<br>~~CO~~<br>se ~~GGG~~<br>seeG<br>Po|||
||**LOAD REGULATION**<br>**Note.6**<br>Po<br>~~a~~|±5.0%<br>±5.0%<br>±5.0%<br>±5.0%<br>±3.0%<br>±3.0%<br>±3.0%<br>±2.0%<br>se eG<br>Po|||
||**SETUP, RISE, HOLD UP TIME**<br>Po<br>~~a~~|1000ms, 50ms, 12ms at full load<br>Po|||
||**VOLTAGE RANGE**<br>a<br>a|85 ~ 264VAC 120 ~ 370VDC|||
||**FREQUENCY RANGE**<br>a|47 ~ 63Hz|||
||**EFFICIENCY (Typ.)**<br>a<br>ee|68%<br>74%<br>74%<br>76%<br>77%<br>79%<br>80%<br>82%<br>ee<br>GG|||
||**AC CURRENT**<br>~~ee~~|0.18A / 100VAC<br>~~ee~~|||
||**INRUSH CURRENT (max.)**<br>a|Cold start 15A/ 115VAC 30A / 230VAC|||
||**LEAKAGE CURRENT(max.)**<br>a|Touch current < 50 A/264VAC<br>μ<br>|||
||**OVERLOAD**<br>a|Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>>105% rated output power<br> ~~Ce~~<br>~~|~~|||
||**OVER VOLTAGE**<br>~~ae~~|110 ~ 140% rated output power<br>Protection type : Clamp by zener diode<br>Re<br>~~PO~~|||
||**WORKING TEMP.**<br>~~ae~~<br>as|0 ~ +50<br>(Refer to "Derating Curve")<br>℃<br>~~PO~~|||
||**WORKING HUMIDITY**<br>~~ae~~<br>as|20% ~ 90% RH non-condensing<br>~~PO~~|||
||**STORAGE TEMP., HUMIDITY**<br>as<br>a|-20 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||
||**TEMP. COEFFICIENT**<br>a|±<br>℃<br>℃<br>0.04% /<br>(0 ~ 40<br>)|||
||**VIBRATION**<br>a<br>a|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes|||
||**SAFETY STANDARDS**<br>a<br>a<br>a|TUV EN60601-1, EN60601-1-11,<br>approved<br>EAC TP TC 004<br>|||
||**ISOLATION LEVEL**<br>a|Pimary - Secondary: 2 x MOPP<br>|||
||**WITHSTAND VOLTAGE**<br>a~~|~~|I/P-O/P:5656VDC<br>~~|~~|||
||**ISOLATION RESISTANCE**<br>~~|~~<br>~~ee~~|I/P-O/P:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>~~|~~<br>~~ee~~|||
||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~ee~~<br>es<br>es|**Parameter**<br>~~ee~~<br>~~GO~~<br>~~GQ~~|**Standard**<br>~~ee~~<br>~~GO~~<br>~~GQ~~|**Test Level / Note**<br>~~ee~~<br>~~GO~~<br>~~GQ~~|
|||Conductedemission<br>~~GQ~~|EN55011 (CISPR11)<br>~~GQ~~|Class B<br>~~GQ~~|
|||Radiated emission<br>~~GO~~<br>~~GG~~|EN55011 (CISPR11)<br>~~GO~~<br>~~GG~~|Class B<br>~~GO~~<br>~~GG~~|
|||Harmonic current<br>~~GG~~<br>~~eG~~|EN61000-3-2<br>~~GG~~<br>~~eG~~|Class A<br>~~GG~~<br>~~eG~~|
|||Voltage flicker<br>~~eG~~<br>~~Ce~~|EN61000-3-3<br>~~eG~~<br>~~Ce~~|-----<br>~~eG~~<br>~~Ce~~|
|||EN55024 , EN60601-1-2, EN61204-3<br>~~Ce~~|||
|||**Parameter**<br>~~Ge~~|**Standard**<br>~~Ge~~|**Test Level / Note**<br>~~Ge~~|
|||ESD<br>~~GG~~|EN61000-4-2<br>~~GG~~|Level 4, 15KV air ; Level 4, 8KV contact<br>~~GG~~|
|||RF field susceptibility|EN61000-4-3|Level 3, 10V/m(80MHz~2.7GHz)<br>Table 9, 9~28V/m(385MHz~5.78GHz)|
|||EFT bursts<br>~~GO~~|EN61000-4-4<br>~~GO~~|Level 3, 2KV<br>~~GO~~|
|||Surge susceptibility<br>~~GO~~|EN61000-4-5<br>~~GO~~|Level 3, 1KV/Line-Line<br>~~GO~~|
|||Conducted susceptibility<br>~~De~~|EN61000-4-6<br>~~De~~|Level 2, 3V<br>~~De~~|
|||Magnetic field immunity<br>~~De~~<br>~~eG~~|EN61000-4-8<br>~~De~~<br>~~eG~~|Level 4, 30A/m<br>~~De~~<br>~~eG~~|
|||Voltage dip, interruption|EN61000-4-11|>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|
|||500Khrs min. MIL-HDBK-217F(25<br>)<br>℃|||
||**DIMENSION**<br>es<br>es|32*66*42.5mm (L*W*H)|||
||**PACKING**<br>es<br>a|100g ; 90pcs / 10Kg / CARTON|||
||**PLUG**<br>a<br>es|See page 4~5 ; Other type available by customer requested|||
||**CABLE**<br>See page 4~5 ; Other type available by customer requested<br>℃<br>es<br>1.All parameters are specified at230VAC input, rated load, 25<br>70% RH ambient.<br>2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.<br>3.Ripple & noise are measured at20MHz by using a 12" twisted pair terminated with a 0.1<br>f & 47<br>f capacitor.<br>4.Tolerance: includes set up tolerance, line regulation, load regulation.<br>5.Line regulation is measured from low line to high line at rated load.<br>6.Load regulation is measured from 0% to 100% rated load.<br>7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http://www.meanwell.com)||||
**NOTE**
_File Name:GSM06E-SPEC 2018-01-15_
**GSM06E series**
## 6W AC-DC Reliable Green Medical Adaptor
**==> picture [511 x 668] intentionally omitted <==**
**----- Start of picture text -----**<br>
Derating Curve Static Characteristics<br>100 100<br>90<br>80<br>70 70<br>60<br>50<br>40<br>0 10 20 30 40 50 85 100 110 135 155 230 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>Mechanical Specification<br>34.5±1<br>Name Plate<br>4ψ<br>13.6 18.3<br>18 19.8<br>2 pole EURO plug<br>19±0.5 UL2468 22AWG 1220 +150/-0mm for 5~9V<br>UL2468 24AWG 1830 +150/-0mm for 12~24V<br>62.5±1<br>42.5 ± 1<br>66 ± 1<br>32 ± 1<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br>
_File Name:GSM06E-SPEC 2018-01-15_
**GSM06E series**
6W AC-DC Reliable Green Medical Adaptor
## **DC output plug**
◎ Standard plug: P1J
**==> picture [369 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
Unit:mm<br>P1J Pin Assignment<br>5.5 11±0.5mm C"+"<br>2.1<br>Outside Inside<br>**----- End of picture text -----**<br>
◎ Optional DC plug:
|Tuning Fork Style<br>~~rs~~|Tuning Fork Style<br>~~rs~~|Type No.<br>~~rs~~|A<br>~~rs~~|B<br>~~rs~~|C<br>~~rs~~|
|---|---|---|---|---|---|
||||OD<br>~~rs~~|ID<br>~~rs~~|L<br>~~rs~~|
|B<br>A<br>~~rs~~<br>ee|C<br>(Straight)<br>~~rs~~<br>~~Ce~~|P1I<br>~~rs~~<br>~~Ce~~|5.5<br>~~rs~~<br>~~Ce~~|2.1<br>~~rs~~<br>~~Ce~~|9.5<br>~~rs~~<br>~~Ce~~|
|||P1L<br>~~rs~~<br>~~Ce~~|5.5<br>~~rs~~<br>~~Ce~~|2.5<br>~~rs~~<br>~~Ce~~|9.5<br>~~rs~~<br>~~Ce~~|
|||P1M<br>~~Ce~~|5.5<br>~~Ce~~|2.5<br>~~Ce~~|11.0<br>~~Ce~~|
||C<br>(Right-angled)<br>~~Ce~~<br>~~a~~<br>~~=~~<br>~~—<—~~|P1IR<br>~~Ce~~<br>~~a~~<br>~~=~~|5.5<br>~~Ce~~<br>~~a~~<br>~~=~~|2.1<br>~~Ce~~<br>~~a~~<br>~~=~~|9.5<br>~~Ce~~<br>~~a~~<br>~~=~~|
|||P1JR<br>~~Ce~~<br>~~a~~<br>~~=~~|5.5<br>~~Ce~~<br>~~a~~<br>~~=~~|2.1<br>~~Ce~~<br>~~a~~<br>~~=~~|11.0<br>~~Ce~~<br>~~a~~<br>~~=~~|
|||P1LR<br>~~=~~<br>~~—<—~~|5.5<br>~~=~~<br>~~—<—~~|2.5<br>~~=~~<br>~~—<—~~|9.5<br>~~=~~<br>~~—<—~~|
|||P1MR<br>~~=~~<br>~~—<—~~|5.5<br>~~=~~<br>~~—<—~~|2.5<br>~~=~~<br>~~—<—~~|11.0<br>~~=~~<br>~~—<—~~|
|Barrel Style<br>~~=~~<br>~~—<—~~<br>~~rr~~||Type No.<br>~~=~~<br>~~—<—~~<br>~~rr~~|A<br>~~=~~<br>~~—<—~~<br>~~rr~~|B<br>~~=~~<br>~~—<—~~<br>~~rr~~|C<br>~~=~~<br>~~—<—~~<br>~~rr~~|
||||OD<br>~~rr~~<br>~~ee~~|ID<br>~~rr~~<br>~~ee~~|L<br>~~rr~~<br>~~ee~~|
|A<br>B<br>~~rr~~<br>R~~w~~<br>7~~>=~~|C<br>(Straight)<br>~~rr~~<br>~~ee~~<br>~~—~~<br>~~——~~<br>|P2I<br>~~rr~~<br>~~ee~~<br>~~—~~|5.5<br>~~rr~~<br>~~ee~~<br>~~ee~~<br>~~—~~|2.1<br>~~rr~~<br>~~ee~~<br>~~ee~~<br>~~—~~|9.5<br>~~rr~~<br>~~ee~~<br>~~ee~~<br>~~—~~|
|||P2J<br>~~—~~|5.5<br>~~ee~~<br>~~—~~|2.1<br>~~ee ~~<br>~~—~~|11.0<br> ~~ee~~<br>~~—~~|
|||P2L<br>~~—~~<br>~~——~~<br>|5.5<br>~~—~~<br>|2.5<br>~~—~~<br>|9.5<br>~~—~~<br>|
|||P2M<br>~~—~~<br>~~——~~<br>|5.5<br>~~—~~<br>|2.5<br>~~—~~<br>|11.0<br>~~—~~<br>|
||C<br>(Right-angled)<br>~~—~~<br>~~——~~<br>~~>=~~<br>~~ee~~<br>~~—~~|P2IR<br>~~—~~<br>~~——~~<br>~~>=~~|5.5<br>~~—~~<br>~~>=~~|2.1<br>~~—~~<br>~~>=~~|9.5<br>~~—~~<br>~~>=~~|
|||P2JR<br>~~—~~<br>~~——~~<br>~~>=~~|5.5<br>~~—~~<br>~~>=~~|2.1<br>~~—~~<br>~~>=~~|11.0<br>~~—~~<br>~~>=~~|
|||P2LR<br>~~>=~~<br>~~ee~~|5.5<br>~~>=~~<br>~~ee~~|2.5<br>~~>=~~<br>~~ee~~|9.5<br>~~>=~~<br>~~ee~~|
|||P2MR<br>~~>=~~<br>~~ee ~~<br>~~—~~|5.5<br>~~>=~~<br> ~~ee~~<br>~~—~~|2.5<br>~~>=~~<br>~~ee ~~<br>~~—~~|11.0<br>~~>=~~<br> ~~ee~~<br>~~—~~|
|Lock Style<br>~~>=~~<br>~~—~~<br>~~rr~~<br>~~=~~<br>~~ee~~<br>SS||Type No.<br>~~>=~~<br>~~—~~<br>~~rr~~<br>~~ee~~<br>|A<br>~~>=~~<br>~~—~~<br>~~rr~~|B<br>~~>=~~<br>~~—~~<br>~~rr~~|C<br>~~>=~~<br>~~—~~<br>~~rr~~|
||||OD<br>~~rr~~<br>|ID<br>~~rr~~<br>~~ee~~<br>|L<br>~~rr~~<br>~~ee~~<br>|
|A<br>B<br>C<br>Locking<br>SWITCHCRAFT original or equivalent<br>~~rr~~<br>~~=~~<br>~~ee~~<br>SS ~~6~~(~~oa—<~~||P2S(S761K)<br>P2K(761K)<br>~~rr~~<br>~~ee~~<br>~~—<~~|5.53<br>5.53<br>~~rr~~<br>~~—<~~|2.03<br>2.54<br>~~rr~~<br>~~ee~~<br>~~—<~~|12.06<br>12.06<br>~~rr~~<br>~~ee~~<br>~~—<~~|
|||P2C(S760K)<br>P2D(760K)<br>~~ee~~<br>~~—<~~|5.53<br>5.53<br>~~—<~~|2.03<br>2.54<br>~~ee~~<br>~~—<~~|9.52<br>9.52<br>~~ee~~<br>~~—<~~|
|Min. Pin Style<br> ~~6 ~~(~~oa —<~~<br>~~ARR~~||Type No.<br>~~—<~~<br>~~ARR~~|A<br>~~—<~~<br>~~ARR~~|B<br>~~—<~~<br>~~ARR~~|C<br>~~—<~~<br>~~ARR~~|
||||OD<br>~~ARR~~|ID<br>~~ARR~~|L<br>~~ARR~~|
|B<br>A<br>C<br>EIAJ equivalent<br>~~ARR~~<br>~~ee~~<br>~~ee~~||P3A<br>~~ARR~~<br>~~ee~~|2.35<br>~~ARR~~<br>~~ee~~|0.7<br>~~ARR~~<br>~~ee~~|11.0<br>~~ARR~~<br>~~ee~~|
|||P3B<br>~~ee~~|4.0<br>~~ee~~|1.7<br>~~ee~~|11.0<br>~~ee~~|
|||P3C<br>P3B<br>~~ee~~<br>~~ee~~|4.0<br>4.75<br>~~ee~~<br>~~ee~~<br>~~ee~~|1.7<br>1.7<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|11.0<br>11.0<br>~~ee~~<br>~~ee~~<br>~~ee~~|
_File Name:GSM06E-SPEC 2018-01-15_
**GSM06E series**
6W AC-DC Reliable Green Medical Adaptor
A B C D Center Pin Style Type No. ~~ee~~ OD ID L Center Pin A C P4A 5.5 3.4 11.0 1.0 P4B 6.5 4.4 11.0 1.4 B D EIAJ equivalent ~~ee~~ P4C 7.4 5.1 11.0 0.6 ~~ee~~ Pin Assignment Min. DIN 3 Pin with Lock (male) ~~ea am~~ Type No. ~~ee ee eee EE~~ PIN No. Output 1 +Vo 1 2 R6B 2 -Vo 3 KYCON KPPX-3P equivalent 3 +Vo Pin Assignment Min. DIN 4 Pin with Lock (male) Type No. ~~eecee~~ PIN No. ~~eee~~ Output 1 +Vo 2 3 2 -Vo (@\) 1 4 ~~cam~~ ff ~~l~~ R7B 3 -Vo KYCON KPPX-4P equivalent 4 +Vo 24 Js | ~~e=~~ ~~**e**~~ Pin Assignment Min. DIN 4 Pin with Lock (female) Type No. ~~eeee~~ PIN No. Output ~~ee ee~~ 1 +Vo 2 -Vo 2 3 R7BF 1 4 3 -Vo KYCON KPJX-CM-4S equivalent ~~a~~ 4 +Vo Pin Assignment Stripped and tinned leads Type No. ~~ees~~ PIN No. Output 1 1 +Vo ( Ribbed ) 2 L1 by customer 2 Length of Land L1 by request -Vo (MW’s standard length, L: 25 mm, L1: 10 mm) ( Letter ) ~~- ==] eee~~ **Installation Manual** Please refer to : http://www.meanwell.com/manual.html
_File Name:GSM06E-SPEC 2018-01-15_
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →