Image not available
Illustrative purposes only
G9TA5027M
Power Relay, G9TA Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON / PARTNER STOCK
- Product type: Power Relays
- SVHC: No SVHC (27-Jun-2024)
- Product Range: G9TA Series
| Delivery and price | |
|---|---|
| Units per pack | 18 |
| Price | 15.28 € |
| Current stock | 10+ |
| Lead time | 30 days |
G9TA AC Power Latching Relay ~~ee~~ **60 A High power latching relay** G 9 T A - High power switching, Compact size • High magnetic latching force provides vibration resistance • Low contact resistance • PCB terminals type available • Conforms to UL 508 (Except PCB terminals type) **RoHS Compliant** - ~~aie~~ **Model Number Structure Application Examples G9TA-** **1 A** • Smart Meter • Lighting control 1 2 3 4 • PV Inverter • EV Charger - 1. Relay Function 2. Number of poles ~~ns~~ U: Single-winding latching 1: 1-Pole G - K: Double-winding latching 3. Contact Form 4. Terminal shape - A: SPST-NO TH: M5 securing screw TW: Welding terminals P: PCB terminals **Ordering Information** Classification Contact Form Terminal Shape Enclosure rating Model Rated coil voltage Minimum packing unit M5 securing screw G9TA-U1ATH Single coil Welding terminals G9TA-U1ATW 12 VDC PCB terminals G9TA-U1AP SPST-NO Flux protection 25 pcs/tray M5 securing screw G9TA-K1ATH Double coils Welding terminals G9TA-K1ATW 12 VDC PCB terminals G9TA-K1AP Note. When ordering, add the rated coil voltage to the model number. Example: G9TA-U1ATH DC12 ~~_foe~~ Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as[][] VDC. ## **Ratings** **Coil** **Single-winding Latching Type** Must reset Item Rated current (mA) Coil resistance (Ω) Must set voltage voltage Max. voltage Power consumption Rated Voltage (V) % of rated voltage Set coil (W) Reset coil (W) DC 12 83 145 80% max. 80% max. 110% max. Approx. 1.0 ~~ES~~ **Double-winding Latching Type** ~~————~~ Must reset Item Rated current (mA) Coil resistance (Ω) Must set voltage voltage Max. voltage Power consumption Rated Voltage (V) Set coil Reset coil Set coil Reset coil % of rated voltage Set coil (W) Reset coil (W) ~~SSS~~ DC 12 217 217 55 55 80% max. 80% max. 110% max. Approx. 2.6 Approx. 2.6 Note 1. The rated current and coil resistance were measured at a coil temperature of 23°C with tolerances of ± 10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The maximum permissible voltage is the maximum value of the fluctuation range for the Relay coil operating power supply and was measured at an ambient temperature of 23°C. **Contacts** Model G9TA-U1A /G9TA-K1A Item Load Resistive load Inductive load (PF=0.5) Contact type SPST-NO Contact material Ag Alloy Rated load 60 A at 250 VAC Rated carry current 60 A Max. switching voltage 250 VAC ~~_~~ Max. switching current 60 A **1** G9TA **AC Power Latching Relay** G 9 T A ## **Characteristics** |Item|Item|G9TA-U1A|G9TA-K1A| |---|---|---|---| |Contact resistance *1||2 mΩmax.|| |Set time *2||30 ms max.|20 ms max.| |Reset time *2||30 ms max.|20 ms max.| |Minimum pulse width||100 ms|| |Maximum pulse width||1,000 ms|| |Insulation resistance *3||1,000 MΩmin.|| |Dielectric strength|Between coil and contacts|4,000 VAC, 50/60 Hz for 1 min|| ||Between contacts of the<br>same polarity|1,500 VAC, 50/60 Hz for 1 min|| |Impulse withstand<br>voltage|Between coil and contacts|6 kV|| |Vibration resistance|Destruction|10 to 150 to 10 Hz, f < 60 Hz: Constant amplitude 0.075 mm, f > 60 Hz: Constant acceleration 9.8 m/s2|| ||Malfunction|10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)|| |Shock resistance|Destruction|1,000 m/s2|| ||Malfunction|100 m/s2|| |Durability|Mechanical|100,000 operations min. (at 7,200 operations/h)|| ||Electrical *4|5,000 operations, resistive load and then<br>5,000 operations, inductive load (PF=0.5) (operation: ON for 10 sec, OFF for 20 sec) *5|| |Ambient operating temperature||-40 to 85°C (with no icing or condensation)|| |Ambient operating humidity||5 to 85%|| |Weight||Approx. 42 g|| Note. The values given above are initial values. *1. Measurement conditions: 24 VDC, 1 A, voltage drop method. *2. Measurement conditions: Rated operating voltage applied, not including contact bounce. Ambient temperature: 23°C - *3. Measurement conditions: The insulation resistance was measured with a 500 VDC megohm meter at the same locations as the dielectric strength was measured. *4. Contact your OMRON sales representative for Electrical Durability technical data. *5. The characteristic meets IEC62055-31 test requirement. **2** G9TA **AC Power Latching Relay** (Unit: mm) G 9 T A ## **Dimensions** Please visit our website, which is noted on the last page. ## **G9TA-U1ATH** **==> picture [511 x 669] intentionally omitted <==** **----- Start of picture text -----**<br> 39.1 max.<br>Terminal arrangement/Internal Connections<br>(TOP VIEW)<br>34.5 max. 30 S<br>R<br>1 2 3 4<br>4<br> 4.95 4<br>5 9.9<br>10 5 6.7 Check carefully the coil polarity of the Relay.<br> 10<br>4.65<br>9.3 Two, �5.5 dia.<br>5±0.05<br>7.7<br>18.55 Two, �0.64±0.01<br>14.2 [18 max.]<br> 3.7<br>1 1 3.7 CAD Data<br>G9TA-U1ATW<br>39.1 max.<br>Terminal arrangement/Internal Connections<br>(TOP VIEW)<br>34.5 max. S -<br>30 - R<br>1 2 3 4<br>4<br>8.8<br>Check carefully the coil polarity of the Relay.<br>5±0.05<br>7.7 18.55 Two, �0.64±0.01<br>12 [10.6]<br>14.2 [18 max.]<br>1 1 CAD Data<br>G9TA-U1AP<br>39.1 max. 18 max. PCB Mounting Holes<br>(BOTTOM VIEW)<br>5±0.1<br>8.7±0.1 19.05±0.1 (2.8)<br>(3.4)<br>36.7 max.<br>30 4±0.1 0.6±0.1<br>4±0.1 Two, �1.2±0.1<br>5.5<br>8.7 19.05 5 4 4 Six, �2±0.1<br>1 1 Two, �0.64 6-1.5<br>Terminal arrangement/Internal Connection<br>(BOTTOM VIEW)<br>1 2 3 4<br>S -<br>- R<br>-<br>-<br>**----- End of picture text -----**<br> Check carefully the coil polarity of the Relay. **3** G9TA **AC Power Latching Relay** (Unit: mm) ## **G9TA-K1ATH** **==> picture [545 x 631] intentionally omitted <==** **----- Start of picture text -----**<br> 39.1 max.<br>Terminal arrangement/Internal Connections<br>(TOP VIEW)<br>34.5 max.<br>30 S - R<br>1 2 3 4 5<br>4<br>5 4 6.7 Check carefully the coil polarity of the Relay.<br>10 5<br> 10<br>4.65<br>9.3 4.95 Two, �5.5 dia.<br>9.9<br>5±0.05 5±0.05<br>7.7 13.55 Three, �0.64±0.01<br>18 max.<br>14.2<br> 3.7<br>1 1 3.7 CAD Data<br>G G9TA-K1ATW 39.1 max.<br>9<br>Terminal arrangement/Internal Connections<br>T (TOP VIEW)<br>A<br>34.5 max.<br>30 S - R<br>1 2 3 4 5<br>4<br>8.8 Check carefully the coil polarity of the Relay.<br>5±0.05 5±0.05<br>7.7 13.55 Three, �0.64±0.01<br>12 [10.6]<br>14.2 [18 max.]<br>1 1 CAD Data<br>G9TA-K1AP<br>39.1 max. 18 max. PCB Mounting Holes<br>(BOTTOM VIEW)<br>5±0.1 5±0.1<br>8.7±0.1 14.05±0.1 (2.8)<br>(3.4)<br>36.7 max. 30 4±0.1 0.6±0.1<br>4±0.1 Three, �1.2±0.1<br>5.5<br>1 8.7 114.05 5 5 Three, �0.64 4 46-1.5 Six, �2±0.1<br>Terminal arrangement/Internal Connections<br>(BOTTOM VIEW)<br>1 2 3 4 5<br>S - R<br>**----- End of picture text -----**<br> **==> picture [135 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Check carefully the coil polarity of the Relay.<br>**----- End of picture text -----**<br> > Note 1. Relay is delivered as "reset" status unless specified otherwise. However, the status may change due to the shock from transportation or mounting operations. Therefore, it is recommended the relay should be set to the expected status via a power supply before being used. Note 2. In order to maintain "set" or "reset" status, the energizing voltage to coil & the pulse width shouldn't lower then the rated value. Note 3. Do not energize both of set and reset coil simultaneously. Note 4. Energizing time longer than 1,000 ms should be avoided. **4** G9TA **AC Power Latching Relay** G 9 T A ## **Engineering Data** **Maximum Switching Capacity G9TA-U1A** **G9TA-K1A** **==> picture [276 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> 1000 1000<br>100 AC Resistive Load 100 AC Inductive Load (PF=0.5)<br>60 60<br>10 10<br>1 1<br>1 10 100 250 1000 1 10 100 250 1000<br>Switching voltage (V) Switching voltage (V)<br>Switching current (A) Switching current (A)<br>**----- End of picture text -----**<br> ## **Approved Standards** The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values before use. ## **UL Recognized: (File No. E41515)** |**Model**|**Contact form**|**Coil ratings**|**Contact ratings**|**Number of test operations**| |---|---|---|---|---| |G9TA-U1ATH<br>G9TA-U1ATW<br>G9TA-K1ATW<br>G9TA-K1ATH|SPST-NO (1a)|12V DC|60 A, 277 V AC (Resistive) 70°C|6,000| ||||60 A, 250 V AC (Resistive) and then 60 A,<br>250 V (PF=0.5), 10 sec. ON / 20 sec. OFF,<br>40°C|5,000 for resistive and then<br>5,000 for PF=0.5| ## **Safety Precautions** - **Please refer to "PCB Relays Common Precautions" for correct use.** ## Correct Use ## **Installation** - The relay contacts are polarized. Incorrect wiring may cause a failure to break the circuit. Wire the Relay with care. - Install the Relays in locations that are as dry as possible and have as little dust, dirt, and harmful gas. - Using the Relay under high temperature, high humidity, or harmful gas may deteriorate its performance characteristics due to condensation or corrosive materials, resulting in failure or burn damage to the Relay. ## **Relay Service Life** - The electrical durability of these Relays is specified as the number of load switching operations under a resistive load and OMRON-specified standard testing conditions. The coil drive circuit, ambient environment, switching frequency, or load conditions (e.g., inductive load or capacitor load) may reduce the service life and possibly lead to failure to break. Always confirm the service life in the actual equipment. ## **Wiring** - Be sure to tighten all screws to the appropriate torque given below. - Loose screws may result in burning due to abnormal heat generation during energization. - M5 screws: 1.57 to 2.35 N·m - Use a spring washer in order to prevent deformation and looseness. - Allow suitable slack on leads when wiring, and do not apply excessive force to the terminals. Please check each region's Terms & Conditions by region website. ## **OMRON Corporation** **Electronic and Mechanical Components Company** ## **Regional Contact** **Americas Europe** https://www.components.omron.com/ http://components.omron.eu/ **Asia-Pacific China** https://ecb.omron.com.sg/ https://www.ecb.omron.com.cn/ **Korea Japan** https://www.omron-ecb.co.kr/ https://www.omron.co.jp/ecb/ © OMRON Corporation 2018-2020 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. **Cat. No. J220-E1-03** 0120(0318) **5**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →