Image not available
Illustrative purposes only
G9KB-1A-E DC24
Power Relay, SPST-NO-DM, 24 VDC, 100 A, G9KB Series, Through Hole, Non Latching
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON ELECTRONIC COMPONENTS
- Product type: Power Relays
- SVHC: No SVHC (27-Jun-2024)
- Coil Type: Non Latching
- Coil Voltage: 24VDC
- Product Range: G9KB Series
- Relay Mounting: Through Hole
- Coil Resistance: 206ohm
- Contact Current: 100A
- Relay Terminals: PC Pin
- Contact Material: Silver Alloy, Cadmium Free
- Contact Voltage VAC: -
- Contact Voltage VDC: 600V
- Contact Configuration: SPST-NO-DM
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 46.43 € |
| Current stock | 10+ |
| Lead time | 30 days |
**G9KB** PCB Power Relays G 9 K B ## **Power Relay with Bidirectional Switching and a High Capacity of up to 600 VDC, 50 A (Standard Model)/ 800 VDC, 100 A * (High-Capacity Model)** - 100 A switching up to a maximum of 600 VDC - Max. switching voltage 600 VDC (standard model) / 800 VDC (high-capacity model) - Rated carry/max. switching current 50 A (standard model) / 100 A (high-capacity model) - Ambient temperature 85°C - Contact gap: 3.6 mm or more - Low initial contact resistance ≤5 m Ω - The UL60947-4-1 and the EN61810-10 required for the energy storage system have been certificated **Refer to the** _**Precautions**_ **on page 5.** ## **Model Number Legend** ## **G9KB-** **-** - 1 2 3 ## **Application Examples** - Energy Storage System - V2X (V2H, V2B, etc.) - DC household appliances 1. Number of Poles 2. Contact Form 1: 1-pole A: SPST-NO (1a) 3. Special specification None: Standard E : High-capacity - EV Charger ## **Ordering Information** Classification Contact form Enclosure rating Model Rated coil voltage (V) Minimum packing unit Standard G9KB-1A 12 VDC ~~e~~ High-capacity SPST-NO (1a) ~~ee~~ Flux protection G9KB-1A-E 24 VDC 36 pcs/box Note. When ordering, add the rated coil voltage to the model number. Example: G9KB-1A DC12 Rated coil voltage Both the coil voltage on the product and the packing will be marked as VDC. ## **Ratings** ## **Coil** |Rated voltage|Rated current<br>(mA)|Coil resistance<br>(Ω)|Must operate voltage<br>(V)|Must release voltage<br>(V)|Max. voltage<br>(V)|Power consumption<br>(mW)| |---|---|---|---|---|---|---| ||||% of rated voltage|||| |12 VDC|Approx. 235.3|51|75% max. **|10 to 32%|110%<br>(at 23°C)|Approx. 2,800<br>Approx. 575 *| |24 VDC|Approx. 116.5|206||||| Note 1. The rated current and resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. - Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The maximum permissible voltage is the maximum value of the fluctuation range for the relay coil operating power supply and was measured at an ambient temperature of 23°C. - Note 4. Use this relay with coil voltage reduction. - Power consumption with Holding Voltage is approx. 575 mW (when applying Holding Voltage at 45%). Please confirm the details on page 5, under Coil Voltage Reduction (Holding Voltage) after Relay Operation. - ** Some mounting directions are not guaranteed. Please confirm the details on page 5 Mounting Direction. **1** **G9KB** **PCB Power Relays** G 9 K B ## **Contacts** |Item|Standard|High-capacity| |---|---|---| |Contact type|Double make|| |Contact material|AgAlloy (Cd free)|| |Rated load(Resistive load)|50 A at 600 VDC/1 A at 600 VDC|100 A at 600 VDC/100 A at 500 VDC/50 A at 800 VDC/18 A at 800 VDC| |Rated carrycurrent|50 A|100 A| |Max. switchingvoltage|600 VDC|800 VDC| |Max. switchingcurrent|50 A|100 A| ## Characteristics |Item<br>Classification|Item<br>Classification|Standard|High-capacity| |---|---|---|---| |Contact resistance *1||5 mΩmax.|| |Operate time *2||30 ms max.|| |Release time *2||10 ms max.|| |Insulation resistance *3||1,000 MΩmin.|| |Dielectric<br>strength|Between coil and contacts|5,000 VAC, 50/60 Hz for 1 min|| ||Between contacts of the same polarity|2,500 VAC, 50/60 Hz for 1 min|| |Impulse withstand voltage||Between coil and contacts 10 kV(1.2 × 50μs)|| |Vibration<br>resistance|Destruction|10 to 55 to 10 Hz, 0.75 mm single amplitude(1.5 mm double amplitude)|| ||Malfunction|Excitation:<br>10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)<br>No excitation: 10 to 55 to 10 Hz, 1.5 mm single amplitude(0.3 mm double amplitude)|| |Shock<br>resistance|Destruction|1,000 m/s2|| ||Malfunction|Excitation:<br>100 m/s2<br>No excitation: 50 m/s2|| |Durability|Mechanical|1,000,000 operations min.(at 10,800 operations/h)|| ||Electrical (Resistive) *4|(1) 600 VDC 50 A 2,000 operations min.<br>(2) 600 VDC 1 A 100,000 operations min.<br>(Switching frequency: 1 second ON - 9 seconds OFF<br>at 85°C and 25% to 75% RH) *5|(1) 600 VDC 100 A 100 operations min.<br>(2) 500 VDC 100 A 300 operations min.<br>(3) 800 VDC 50 A 10 operations min.<br>(4) 800 VDC 18 A 6,000 operations min.<br>(Switching frequency: 1 second ON - 9 seconds OFF<br>at 85°C and 25% to 75% RH) *5| |Failure rate(P level) (Reference value)*6||1 A at 5 VDC|| |Use<br>conditions|Coil holdingvoltage *7|45% to 60% of rated coil voltage|| ||Ambient operating temperature|-40°C to 85°C (with no icing or condensation)|| ||Ambient operatinghumidity|5% to 85%|| |Weight||Approx. 110g|| Note. The values given above are initial values at 23°C. (except electrical durability) *1. Measurement conditions: 6 VDC, 20 A (after 30 seconds) voltage drop method. *2. Measurement conditions: Applied rated coil voltage, no contact bouncing. *3. Measurement conditions: Measured with a 1,000 VDC megohmmeter at the same point as the dielectric strength was measured. *4. This specification is when diode and zener diode are used. For relay coil, please connect diode and zener diode. For more detail, please refer to Diode Connection for Operating Coil on page 5. *5. The humidity range of 25% to 75% conforms to the environmental conditions of JIS C 5442. Also, refer to Relay Service Life on page 6. *6. The value was measured at a switching frequency of 180 operations/ minute. *7. For the detail regarding holding voltage usage, please refer to Coil Voltage Reduction (Holding Voltage) after Relay Operation on page 5. ## **Engineering Data** ## **Durability** **==> picture [40 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> G9KB-1A<br>**----- End of picture text -----**<br> **==> picture [170 x 164] intentionally omitted <==** **----- Start of picture text -----**<br> (Ambient temperature 85°C)<br>100,000<br>400 VDC resistive load<br>10,000<br>600 VDC resistive load<br>1,000<br>10 20 30 40 50 60<br>Switching current (A)<br>No. of operations (operations)<br>**----- End of picture text -----**<br> ## **G9KB-1A-E** **==> picture [168 x 162] intentionally omitted <==** **----- Start of picture text -----**<br> (Ambient temperature 85°C)<br>100,000<br>400 VDC resistive load<br>10,000<br>1,000<br>100<br>600 VDC resistive load<br>10<br>800 VDC resistive load<br>1<br>10 20 30 40 50 60 70 80 90 100 110<br>Switching current (A)<br>No. of operations (operations)<br>**----- End of picture text -----**<br> **2** **G9KB** **PCB Power Relays** G 9 K B ## **Malfunction shock resistance** **==> picture [354 x 243] intentionally omitted <==** **----- Start of picture text -----**<br> Z+1,000 No ExcitationExcitation Measurement:<br>800<br>600<br>Y+ X+<br>1,000 400 1,000<br>200 holding voltage.<br>Standard value:<br>Excitation 100 m/s [2]<br>1,000 1,000<br>X- Y- No excitation 50 m/s [2]<br>Shock direction<br>1,000<br>Z-<br>a an<br>Contact terminal<br>Coil terminal<br>**----- End of picture text -----**<br> Measure the value of contact malfunction happening by applying 3 axes with 6 direction 3 times each. The energized voltage is within the range of the rated holding voltage. ## **Dimensions** Please visit our website, which is noted on the last page. **(Unit:mm)** **G9KB-1A, G9KB-1A-E** **==> picture [374 x 221] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal Arrangement/<br>Internal Connections<br>(BOTTOM VIEW)<br>3 4<br>50.5 MAX.<br>(50) *<br>1 2<br>2.5<br>(No coil polarity)<br>4<br>PCB Mounting Holes<br>2 2 0.8 2.7 4-3.8×3.1 (BOTTOM VIEW)<br>37.0 MAX. 50.5 MAX. 25.9<br>(36.7) * (50) * 16-R0.5 MIN.<br>1 .7 1.7<br>6.4<br>*Average value<br>kl bd<br>_ rt<br>18.75<br>2-1.5×3.2<br>8-R0.5 MIN. 40<br>Tolerance ±0.1<br>**----- End of picture text -----**<br> **3** **G9KB** **PCB Power Relays** G 9 K B ## **Approval Standard** **UL/C-UL Certificated: (File No. E41515)** |Model|Contact form|Coil ratings|Contact ratings|Number of test operations| |---|---|---|---|---| |G9KB-1A|SPST-NO(1a)|12, 24 VDC *|600 VDC 40 A (Resistive) 85°C|6,000| ||||600 VDC 50 A (Resistive) 85°C|2,000| |G9KB-1A-E|SPST-NO(1a)|12, 24 VDC *|600 VDC 100 A (Resistive) 85°C|100| ||||500 VDC 100 A (Resistive) 85°C|300| ||||800 VDC 50 A (Resistive) 85°C|10| ||||800 VDC 18 A (Resistive) 85°C|6,000| - Holding voltage of 45% (after applying rated voltage to coil for 0.1 seconds) **EN/IEC, TÜV Certificated: (Certificate No. R50528195)** |Model|Contact form|Coil ratings|Contact ratings|Number of test operations| |---|---|---|---|---| |G9KB-1A|SPST-NO(1a)|12, 24 VDC *|600 VDC 1 A (Resistive) 85°C|100,000| ||||600 VDC 50 A (Resistive) 85°C|2,000| |G9KB-1A-E|SPST-NO(1a)|12, 24 VDC *|600 VDC 100 A (Resistive) 85°C|100| ||||500 VDC 100 A (Resistive) 85°C|300| ||||800 VDC 50 A (Resistive) 85°C|10| ||||800 VDC 18 A (Resistive) 85°C|6,000| * Holding voltage of 45% (after applying rated voltage to coil for 0.1 seconds) ## **CQC Certificated: (Certificate No. CQC21002322255)** |Model|Contact form|Coil ratings|Contact ratings|Number of test operations| |---|---|---|---|---| |G9KB-1A|SPST-NO(1a)|12, 24 VDC *|600 VDC 1 A (Resistive) 85°C|100,000| ||||600 VDC 50 A (Resistive) 85°C|2,000| |G9KB-1A-E|SPST-NO(1a)|12, 24 VDC *|600 VDC 100 A (Resistive) 85°C|100| ||||500 VDC 100 A (Resistive) 85°C|300| ||||800 VDC 50 A (Resistive) 85°C|10| ||||800 VDC 18 A (Resistive) 85°C|6,000| * Holding voltage of 45% (after applying rated voltage to coil for 0.1 seconds) ## **G9KB-1A** |**G9KB-1A**|**G9KB-1A**|| |---|---|---| |Creepage distance (required value)||12.6 mm min. (IEC) / 10.0 mm min. (UL)| |Clearance (required value)||8.0 mm min. (IEC) / 5.5 mm min. (UL)| |Insulation material group||IIIa| |Type of insulation|coil-contact circuit|Basic (600 V, OV-cat.III, Pollution degree 3, up to 2,000 m above sea level)<br>Reinforced (600 V, OV-cat.III, Pollution degree 2, up to 2,000 m above sea level)| ||open contact circuit|Micro disconnection| |Rated insulation voltage||600 V| |Rated voltage system||600 V| |Category of protection (IEC61810-1)||RTII| |Flammability class (UL94)||V-0| |Coil insulation system (UL)||Class F| ## **G9KB-1A-E** |**G9KB-1A-E**|**G9KB-1A-E**|| |---|---|---| |Creepage distance (required value)||12.5 mm min. (IEC/UL)| |Clearance (required value)||8.0 mm min. (IEC/UL)| |Insulation material group||IIIa| |Type of insulation|coil-contact circuit|Basic (800 V, OV-cat.III, Pollution degree 3, up to 2,000 m above sea level)| ||open contact circuit|Micro disconnection| |Rated insulation voltage||800 V| |Rated voltage system||800 V| |Category of protection (IEC61810-1)||RTII| |Flammability class (UL94)||V-0| |Coil insulation system (UL)||Class F| **4** **G9KB** **PCB Power Relays** ## **Precautions** ## **Please refer to “Safety Precautions for All Relays” for correct use. Electrical Appliances and Materials Safety Act** The G9KB series does not comply with the Electrical Appliances and Materials Safety Act. Please select our relays carefully in accordance with the application you wish to use the product for. ## Warning As this relay is a high-voltage and high-current type, there is a risk of abnormal heat generation, smoke generation or fire if you use the relay with a contact voltage, current, or for a number of times beyond the specified range. Use only within the specified ranges. If the power is switched on when the connections are insufficient, there is a risk of abnormal heat generation. Do not connect and use probes and sockets on individual relays. If the power is switched on when the connections are insufficient, there is a risk of abnormal heat generation. Please install and use relays under recommended conditions. Precautions for Safe Use ~~—~~ ## **Drop** - Do not use relays that have been dropped as they may not function properly. ~~Pe~~ Precautions for Correct Use ## **Mounting Direction** - The relay is limited for mounting direction due to the specification of operation voltage and electrical durability. Do not use in any other direction except as indicated in below chart. There is a risk of reduced operational lifetime for failure to observe this warning. **==> picture [95 x 34] intentionally omitted <==** **----- Start of picture text -----**<br> Upper side<br>Contact terminal<br>Nd<br>Coil terminal<br>**----- End of picture text -----**<br> ## **Coil Voltage Reduction (Holding Voltage) after Relay Operation** - Use this relay with coil voltage reduction. - Apply the rated voltage for 0.1 to 3 seconds to the coil first. - The range of coil rated voltage must be set as 100 to 110%, and holding voltage must be 45 to 60%. Do not exceed the ranges due to the change of coil voltage difference and so on. 100 to 110% (Rated voltage) 45 to 60% (Holding voltage) ~~i~~ 0.1 to 3 seconds Applied coil Coil voltage resistance * Coil power consumption G Rated voltage 100 to 110% 51 Ω (12 VDC) Approx. 2.8 to 3.4 W 9 Holding voltage 45 to 60% 206 Ω (24 VDC) Approx. 0.57 to 1.1 W K * The coil resistances were measured at a coil temperature of 23°C with B tolerances of ± 10%. ~~=~~ **Diode Connection for Operating Coil** • Connect diode and Zener diode (or Varistor) to the coil (refer to the picture below). - Diode is for coil surge absorption. Ensure to include Zener diode as there is a possibility of any influence for switching capability when only using diodes. - Coil has no polarity. Connect the diodes in the reverse polarity of the voltage applied to the coil. - The recommended Zener diode voltage is 3 times that of the rated coil voltage. - Use diodes with reverse dielectric strength 10 times or more that of coil rated voltage, and with forward current more than coil rated current. **==> picture [104 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Diode<br>Relay coil<br>Zenner diode<br>**----- End of picture text -----**<br> ## **PCB Terminal soldering** - Solder at 290°C for 20 seconds (max.) in soldering bath. - It is not possible to wash relay as this is not fully sealed type. **Assembly** - Assemble relays in an environment with less amount of dust and harmful gases. - Using the Relay under high temperature, high humidity, or harmful gas may deteriorate its performance characteristics due to condensation or corrosive materials, resulting in failure or burn damage to the relay. - This product weight is about 110 g. Be careful of the strength of PCB. To reduce soldering crack due to heat stress, use both sides through hole PCB. **5** **G9KB** **PCB Power Relays** ## � **Relay Service Life** - These relays must be used for high DC voltages. The final failure mode is failure to break the circuit. In a worst-case scenario, burning may extend to surrounding components. Do not use these relays outside of the specified ratings and service life, or for any application other than high DC voltages. Implement safety circuits and other safety measures to minimize the risk in case of the unlikely event of a failure. - In a low-humidity or low-temperature (negative) environment, the life cycle may vary as a result of high voltage and largecurrent opening and closing. Therefore, be sure to check on the actual machine. - The coil drive circuit, ambient environment, switching frequency, or load conditions (e.g., inductive load or capacitor load) may reduce the service life and possibly lead to failure to break. Always confirm the service life in the actual equipment. ## � **Micro load** - This is a power relay for high power switching. Do not use for micro loads such as signal switching. ## � **Installation Gap** - Secure an installation gap of 20 mm or more for the G9KB-1A. G 9 K B - Secure an installation gap of 50 mm or more for the G9KB-1A-E. **6** MEMO **7** Please check each region's Terms & Conditions by region website. ## **OMRON Corporation Device & Module Solutions Company** ## **Regional Contact** **Americas Europe** https://components.omron.com/us https://components.omron.com/eu **Asia-Pacific China** https://components.omron.com/ap https://components.omron.com.cn **Korea Japan** https://components.omron.com/kr https://components.omron.com/jp © OMRON Corporation 2022-2024 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. **Cat. No. K340-E1-04** 0324 (0222)
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →