Image not available
Illustrative purposes only
G6D-1A-ASI-DC24
Power Relay, SPST-NO, 24 VDC, 5 A, G6D Series, Through Hole, Non Latching
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON / PARTNER STOCK
- Product type: Power Relays
- SVHC: To Be Advised
- Coil Type: Non Latching
- Coil Voltage: 24VDC
- Product Range: G6D Series
- Relay Mounting: Through Hole
- Coil Resistance: 2.88kohm
- Contact Current: 5A
- Relay Terminals: PC Pin
- Contact Material: Silver Alloy
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 30V
- Contact Configuration: SPST-NO
| Delivery and price | |
|---|---|
| Units per pack | 120 |
| Price | 2.59 € |
| Current stock | 1000+ |
| Lead time | 30 days |
G6D PCB Power Relay G 6 D ## **Slim, Miniature Relay, Capable of Relaying Programmable Controller and Temperature Controller Outputs** - Reduced board space, ideal for high-density mounting (45%. - (6.5 mm (W) × 17.5 mm (L) × 12.5 mm (H)) - Small, yet switches 5 A at 250 VAC/30 VDC. - Allows 300,000 operations with a 2A load at 250 VAC or 30 VDC. ## **RoHS Compliant** ## ■ **Model Number Legend** ## ■ **Application Examples** ## G6D- @@ - @ - @ - Ideal for output applications of control equipments. — — — — 1 2 3 4 **1. Number of Poles 3. Contact Material** ■ **Characteristics** 1: 1-pole ASI: Silver alloy (cadmium-free) **Contact Form** Contact resistance *1 100 m Ω max. A: SPST-NO (1a) **4. Contact surface** Operate time 10 ms max. AP: Au plated Release time 5 ms max. Insulation resistance *2 1,000 M Ω min. **Ordering Informationg Information Information** Between coil 3,000 VAC, 50/60 Hz for and contacts 1 min Enclosure rating Contact form Terminal shape Model Rated coil voltage Minimun packing unit Dielectric strength Between contacts of 750 VAC, 50/60 Hz for 5 VDC the same 1 min G6D-1A-ASI 12 VDC polarity Fully sealed SPST-NO (1a) PCB terminals 24 VDC12 VDC 25 pcs/tube Impulse withstand voltage (between coil and contacts) 6 kV (1.2 x 50 μ s) G6D-1A-ASI-AP 24 VDC 10 to 55 to 10 Hz, 0.75 mm Destruction single amplitude (1.5 mm Note. When ordering, add the rated coil voltage to the model number. Vibration double amplitude) Example: G6D-1A-ASI DC5C5 resistance 10 to 55 to 10 Hz, 0.75 mm Rated coil voltage Malfunction single amplitude However, the notation of the coil voltage on the product case as well as on the packing will be marked (1.5 mm double amplitude) as @@ VDC. Shock Destruction 1,000 m/s[2] **Connecting Socket** resistance Malfunction 100 m/s[2] Applicable relay Model Minimun packing unit Mechanical 20,000,000 operations min. G6D-1A-ASI P6D-04P 25 pcs (at 18,000 operations/hr) 70,000 operations min. (5 A at 250 VAC, resistive **Ratingsgss** load) 70,000 operations min. **Coil** (5 A at 30 VDC, resistive Durability load) Item Rated Coil Must operate Must release Max. Power Electrical 300,000 operations min. Rated voltage current(mA) resistance( Ω ) voltage(V) % of rated voltavoltage(V) ge voltage(V) consumption(mW) (2 A at 250 VAC, resistive load)300,000 operations min. 5 VDC 40 125 (2 A at 30 VDC, resistive 12 VDC 16.7 720 70% max.* 10% min. 160% Approx. 200 load) 24 VDC 8.3 2,880 (at 23 C) Failure rate (P level) (10 mA at 5 VDCat 1,800 operations/hr) Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of (reference value *3) (1 mA at 5 VDC) *4 ±10%. Ambient operating -25 C to 70 C (with no icing Note 2. The operating characteristics are measured at a coil temperature of 23°C. temperature or condensation) Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down. Ambient operating humidity 5% to 85% Weight Approx. 3 g **Contacts** ~~il~~ Note. The data given above are initial values. Item Load Resistive load *1. Measurement conditions: 5 VDC, 1 A, voltage Contact T Sin le drop method. 1: 1-pole ASI: Silver alloy (cadmium-free) **2. Contact Form** - A: SPST-NO (1a) ## ■ **Ordering Informationg Information Information** |Enclosure rating|Contact form|Terminal shape|Model<br>Rated coil voltage|Rated coil voltage|Minimun packing unit<br>unit| |---|---|---|---|---|---| |Fully sealed|SPST-NO (1a)|PCB terminals|G6D-1A-ASI|5 VDC|25 pcs/tube| |||||12 VDC|| |||||24 VDC12 VDC|| ||||G6D-1A-ASI-AP|12 VDC|| |||||24 VDC|| Note. When ordering, add the rated coil voltage to the model number. Example: G6D-1A-ASI DC5C5 - **Connecting Socket** ## ■ **Ratingsgss** ## ● **Coil** Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. - The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down. - **Contacts** |Item<br>Load|Resistive load| |---|---| |Contact Type|Single| |Contact material|Ag-Alloy (Cd free)<br>(Ag-alloy (Cd free)and Auplated)*| |Rated load|5 A at 250 VAC<br>5 A at 30 VDC| |Rated carrycurrent|5 A| |Max. switchingvoltage|250 VAC,30 VDC| |Max. switchingcurrent|5 A| - *2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. - *3. This value was measured at a switching frequency of 120 operations/min. - *4. The values indicated in parentheses ( ) are for the G6D-1A-ASI-AP. **1** G6D **PCB Power Relay** ## ■ **Engineering Data** ## ● **Maximum Switching Capacity** ## ● **Durability** ## ● **Ambient Temperature vs. Maximum Coil Voltage** **==> picture [545 x 409] intentionally omitted <==** **----- Start of picture text -----**<br> 50 500 200<br>30 300<br>180<br>10 AC resistive load 100 160<br>5 50 250 VAC/30 VDC resistive load<br>3 30 140<br>DC resistive load<br>120<br>1 DC inductive load AC inductive load 10<br>0.5 cosφ=0.4 5 250 VAC/30 VDC inductive load 100<br>(cosφ=0.4/ L/R=7 ms)<br>0.3 3<br>80<br>0.1 60<br>0 3 5 10 30 100 250 500 1,000 0 1 2 3 4 5 6 7 8 9 10 0 23 30 40 50 60 70 80 90<br>Switching voltage (V) Switching current (A) Ambient temperature (°C)<br>Note. The maximum coil voltage is the maximum<br>voltage that can be applied to the relay coil.<br>● Ambient Temperature vs. Must ● Shock Malfunction<br>Operate and Must Release G6D-1A-ASI (-AP)<br>Voltages<br>G6D-1A-ASI (-AP)<br>G6 100 Sample: G6D-1A-ASI Must Operating voltage Y 1,000<br>D Number of Relays: 5 pcs Must Recovery voltage 800<br>80 X 600 Z<br>max. 400<br>60 X 200<br>min.<br>40 206<br>Z' X'<br>max. Shock direction<br>20 min.X De-energized Y X X'<br>Z<br>Energized Y' Unit: m/s [2] Z'<br>0 Y'<br>-40 -20 0 20 40 60 80 Coil terminals<br>Ambient temperature (°C) Sample: G6D-1A-ASI 24 VDC<br>Number of Relays: 5 pcs<br>Test conditions: Impose a shock in the ±X, ±Y, and ±Z<br>directions three times each with the Relay energized to<br>check the shock values that cause the Relay to<br>malfunction.<br>4 operations)<br>Switching current (A) Maximum coil voltage (%)<br>Durability (x10<br>Must operate and must release voltage (ratio of rated voltage) (%)<br>**----- End of picture text -----**<br> ## ■ **Dimensions** **==> picture [512 x 234] intentionally omitted <==** **----- Start of picture text -----**<br> G6D-1A-ASI (-AP) PCB Mounting Holes Terminal Arrangement/<br>(Bottom View) Internal Connections<br>0.5 17.5 max(17.3)* . 6.5 max.(6.4)* 2.54 Four, 1.1-dia. (Bottom View)<br>(0.71)<br>12.5 max.<br>(12.4)* 1 5 7<br>2.54<br>5.08<br>3.5 13<br>0.5 0.8 0.3 5.08 (No coil polarity)<br>2.54 7.62 5.0 8 5.08 (1.13) 10.16<br>* Average value Note: Orientation marks are indicated as follows:<br>Socket 19.7 max. PCB Mounting Holes<br>(19.5)* (Bottom View)<br>P6D-04P<br>6.9 max. 2.54 Four, 1.1-dia.<br>(6.7)*<br>(0.86)<br>2.54<br>10.8 5.08<br>6 [±0.1]<br>3.6<br>5.08<br>0.65 0.3 (2.18) 10.16<br>2.54 7 .62 5.0 8<br>* Average value<br>**----- End of picture text -----**<br> **2** G6D **PCB Power Relay** G 6 D ## ■ **Approved Standards** - ●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this datasheet. **UL Recognized** (File No. E41515) |Model|Number of<br>poles|Coil ratings|Contact ratings|Number of test<br>operations| |---|---|---|---|---| |G6D-1A-ASI (-AP)|1|5 to 24 VDC|5 A, 250 VAC 40°C|6,000| ||||5 A, 30 VDC 40°C|| |**CSA Certified**<br> (File No. LR31928)||||| |Model|Number of<br>poles|Coil ratings|Contact ratings|Number of test<br>operations| |G6D-1A-ASI (-AP)|1|5 to 24 VDC|5 A, 250 VAC(Resistive)40°C|6,000| ||||5 A, 30 VDC(Resistive)40°C|| **EN/TÜV Certified** (Registration No. R50167084) |Model|Number of<br>poles|Coil ratings|Contact ratings|Number of test<br>operations| |---|---|---|---|---| |G6D-1A-ASI (-AP)|1|5, 12, 24 VDC|5 A, 250 VAC(cosφ=1.0)70°C|70,000| ||||5 A, 30 VDC(0 ms)40°C|| ## ■ **Precautions** - **Please refer to “PCB Relays Common Precautions” for correct use.** ## Correct Use ## ● **Mounting** - More than two relays can be closely mounted right side up as shown in the following illustration. Upper side Upper side 6.5 mm 1.12 mm 7.62 mm in the Current flow: 5 A max. upside-down direction Current flow: 2 A max. Note. The space between each relay required for heat radiation may vary with operating conditions. Contact your OMRON representative for details. ## ● **Socket Mounting Height** **==> picture [35 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> 18.5 mm max.<br>**----- End of picture text -----**<br> ## ● **Mounting to a P6D** - The P6D is flux-resistive. Do not wash the P6D with water. - Dismount the relay from the socket before soldering the socket to a PCB. - Use Surge Killer Diode when switching a DC inductive load in micro load (about 10 to 100 mA). (Carbon deposition may decrease the contact reliability.) **3** G6D **PCB Power Relay** G 6 D - Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. - Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. **Note: Do not use this document to operate the Unit.** **OMRON Corporation Electronic and Mechanical Components Company** **Contact: www.omron.com/ecb** **Cat. No. K127-E1-04** 0316(0207)(O) **4**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →