FSAGPNXX003LCAC5
Force Sensor, FSA Series, 3 lb, Analogue Output, 5 Vdc, 3%
- Manufacturer: HONEYWELL
- Product type: Force Sensors & Load Cells
- Load Capacity: 3lb
- Product Range: FSA Series
- Supply Voltage: 5VDC
- Operating Temperature Max: 70°C
- Operating Temperature Min: 0°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 107.38 € |
| Current stock | 10+ |
| Lead time | 7 days |
**32311096** Issue B ## Force Sensors FSA Series, Compensated/Amplified ## **Datasheet** ## FEATURES - Wide variety of force ranges - Newton (N): 5, 7.5, 10, 15, 20, 25 - pound (lb): 1, 1.5, 2, 3, 5 - gram (g): 500, 750 - kilogram (kg): 1, 2 - Total Error Band: ±5 %FSS - Accuracy: ±3 %FSS - Ratiometric analog or SPI- or I[2] C-compatible digital output - Fully calibrated and temperature compensated over a temperature range of 5°C to 50°C [41°F to 122°F] - Overforce: 6804 g [15 lb] - Supply voltage: 3.3 Vdc typ. or 5.0 Vdc typ. - Low power consumption: 13 mW (analog) or 20 mW (digital) - Excellent part-to-part repeatability - Enhanced reliability ## DESCRIPTION The FSA Series are piezoresistive-based force sensors offering a ratiometric analog or digital output for reading force over the specified full scale force span and temperature range. They are fully calibrated and temperature compensated for sensor offset, sensitivity, temperature effects, and nonlinearity using an on-board Application Specific Integrated Circuit (ASIC). Direct mechanical coupling allows for easy interface with the sensor, coupling with tubing, membrane or a plunger, providing repeatable performance and a reliable mechanical interface to the application. The package also provides excellent corrosion resistance and isolation to external package stress. All products are designed and manufactured according to ISO 9001 standards. ## VALUE TO CUSTOMERS The FSA Series are designed to meet the customers’ need for a compensated, amplified force sensor that provides analog and digital outputs, a variety of force sensing ranges, and enhanced durability and accuracy. Their flexible design provides multiple standard configurations over a wide operating temperature range. - Stable interface plunger - Internal diagnostic functions available - REACH and RoHS compliant ## POTENTIAL APPLICATIONS Medical: - Ambulatory non-invasive pump pressure - Infusion pumps - Kidney dialysis machines - Occlusion detection Industrial: - Load and compression sensing ## PORTFOLIO The FSA Series joins the FSG Series, FSS Series, FSS-SMT Series, TBF Series, and 1865 Series. ## DIFFERENTIATION - Multiple force ranges allow the customer to choose the force range to maximize sensitivity and improve system resolution/performance - Overforce provides enhanced durability in applications where overforce may exist - Enhanced accuracy includes all errors due to force nonlinearity, force hysteresis, and non-repeatability - Total Error Band enhances system performance - Digital output enhances performance through reduced conversion requirements and the convenience of direct interface to microprocessors - Diagnostics functions allow the user to determine if the sensor is working correctly by detecting if the electrical paths are broken or shorted inside the sensor - Supply voltage provides customers flexibility of design within the application Sensing and Internet of Things **Force Sensors, FSA Series Compensated/Amplified** Table 1. Operating Specifications |Table 1. Operating Specifications|||||||| |---|---|---|---|---|---|---|---| |Characteristic|Analog|||Digital|||Unit| ||Min.|Typ.|Max.|Min.|Typ.|Max.|| |Supply voltage (Vsupply):1, 2, 3<br>3.3 Vdc<br>5.0 Vdc|3.0<br>4.75|3.3<br>5.0|3.6<br>5.25|3.0<br>4.75|3.3<br>5.0|3.6<br>5.25|Vdc| |Supply current:<br>3.3 Vdc<br>5.0 Vdc|—<br>—|2.0<br>2.6|—<br>—|—<br>—|2.8<br>3.9|3.9<br>4.6|mA| |Power input|13|||20|||mW| |Operating temperature range4|0 [32]|—|70 [158]|0 [32]|—|70 [158]|°C [°F]| |Compensated temperature range5|5 [41]|—|50 [122]|5 [41]|—|50 [122]|°C [°F]| |Storage temperature range|-40 [-40]|—|85 [185]|-40 [-40]|—|85 [185]|°C [°F]| |Startup time (power up to data ready)|—|—|5|—|—|3|ms| |Response time|—|1|—|—|0.42|0.84|ms| |Clipping limit:<br>upper<br>lower|—<br>2.5|—<br>—|97.5<br>—|—<br>—|—<br>—|—<br>—|%Vsupply| |SPI/I2C voltage level:<br>low<br>high|—<br>—|—<br>—|—<br>—|—<br>80|—<br>—|20<br>—|%Vsupply| |Pull up on SDA/MISO, SCL/SCLK, SS|—|—|—|1|—|—|kOhm| |Accuracy6|—|—|±3|—|—|±3|%FSS7 BFSL| |Total Error Band8|—|—|±5|—|—|±5|%FSS| |Output resolution|—|—|—|12|—|—|bits| |Long term stability9|—|±1.3|—|—|±1.3|—|%FSS| 1Sensors are either 3.3 Vdc or 5.0 Vdc based on the catalog listing selected. 2Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage. 3The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure. 4Operating temperature range: The temperature range over which the sensor will produce an output proportional to force. 5Compensated temperature range: The temperature range over which the sensor will produce an output proportional to force within the specified performance limits. 6Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the force range at 25°C [77°F]. Includes all errors due to force non-linearity, force hysteresis, and non-repeatability. 7Full Scale Span (FSS): The algebraic difference between the output voltage at full scale force and the output at zero force. 8Total Error Band (TEB): Combined error from calibration, accuracy and temperature effects over the compensated temperature range at 5.0 V from 15 %FSS to 95 %FSS. 9Long-term stability after 1000 hr of operation at 25°C [77°F]. **2** Sensing and Internet of Things **Force Sensors, FSA Series Compensated/Amplified** Table 2. Environmental Specifications **==> picture [542 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Parameter<br>Humidity 0% to 95% RH, non-condensing<br>Vibration MIL-STD-202, Method 214, Condition 1E (16.9 G)<br>Shock MIL-STD-202, Method 213, Condition F (1500 G)<br>Life [1] 1 million full scale force cycles minimum<br>**----- End of picture text -----**<br> 1Life may vary depending on specific application in which the sensor is utilized. ## Table 3. Materials[1] **==> picture [542 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> Component Material<br>Covers high temperature polyamide<br>Plunger stainless steel 316<br>Substrate alumina, ceramic<br>Adhesives epoxy, silicone<br>Electronic components ceramic silicon, glass, solder<br>**----- End of picture text -----**<br> 1Contact Honeywell customer service for detailed material information. Table 4. Absolute Maximum Specifications **==> picture [542 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Min. Max. Unit<br>Supply voltage -0.3 6.0 Vdc<br>Voltage on any pin -0.3 Vsupply + 0.3 V<br>Digital interface clock frequency:<br> SPI 50 800 kHz<br> I [2] C 100 400<br>ESD susceptibility (human body model) 2 — kV<br>Storage temperature range -40 [-40] 85 [185] °C [°F]<br>Overforce limit — 6804 [15] g [lb]<br>Minimum operating voltage 2.8 Vdc<br>Lead soldering time and temperature 4 s max. at 220°C [428°F]<br>**----- End of picture text -----**<br> **3** Sensing and Internet of Things **Force Sensors, FSA Series Compensated/Amplified** Figure 1. Nomenclature and Order Guide For example, **FSAGPNXX001LCAA3** defines an FSA Series Force Sensor, gel coupling, plunger contact element, no diagnostics, 2 lb force range, force unit in pounds, compression force type, analog output, 10% to 90% transfer function, 3.3 Vdc supply voltage **FSA G P N XX 001 L C A A 3 Series Supply Voltage FSA**[Force Sensor ] **3** 3.3 Vdc ±10% Compensated/Amplified **5** 5 Vdc ±10% **Coupling Transfer Function[3] G** Gel **A** 10% to 90% **B** 5% to 95% **Contact Element P** Plunger = **C** 20% to 80% **Diagnostics Option Output N** No diagnostics **A** Analog **D** Diagnostics, sensor short and open **S** SPI **2** I[2] C, Address 0x28 **Future Use 3** I[2] C, Address 0x38 **XX 4** I[2] C, Address 0x48 **5** I[2] C, Address 0x58 **Force Range[1] 6** I[2] C, Address 0x68 **Newton (N) pound (lb) gram (g) kilogram (kg) 005** 5 N **001** 1 lb **500** 500 g **001** 1 kg **Force Type 7.5** 7.5 N **1.5** 1.5 lb **750** 750 g **002** 2 kg **C** Compression **010** 10 N **002** 2 lb **015** 15 N **003** 3 lb **Force Unit 020** 20 N **005** 5 lb **W** Newton (N) **025** 25 N **L** pound (lb) **F** gram (g) **R** kilogram (kg) ~~s~~ ali 1Custom designations available upon request. **COMMON CATALOG LISTINGS** 2Consult with factory. FSAGPDXX010WCAA5 3For other available transfer functions, contact Honeywell customer service. FSAGPDXX001RCAB5 FSAGPDXX010WCAA5 FSAGPDXX001RCAB5 FSAGPNXX1.5LCAC5 FSAGPNXX003LCAC5 FSAGPNXX010WC2C3 FSAGPNXX001RC4C5 FSAGPDXX005LCSB5 FSAGPDXX1.5LC5B5 **4** Sensing and Internet of Things **Force Sensors, FSA Series Compensated/Amplified** ## Figure 2. Transfer Function Limits[1] Analog Version **==> picture [541 x 408] intentionally omitted <==** **----- Start of picture text -----**<br> Compensated Force Range<br>100<br>90<br>80<br>70<br>60 Ideal<br>50<br>5% Total Error Band<br>40<br>30<br>20<br>10<br>0<br>0 1 2 3 4 5 6 7 8 9 10<br>Fmin. Fmax.<br>Force (example unit)<br>0.8 x Vsupply<br>Output (V) = Force range x (Force applied) + 0.10 x Vsupply<br>Digital Version<br>Compensated Force Range<br>100<br>90<br>80<br>70<br>60 Ideal<br>50<br>5% Total Error Band<br>40<br>30<br>20<br>10<br>0<br>0 1 2 3 4 5 6 7 8 9 10<br>Fmin. Fmax.<br>Force (example unit)<br>80%<br>Output (% of 2 [14] counts) = Force range x (Force applied ) + 10%<br>Output (%Vsupply)<br>Output (%Vsupply)<br>**----- End of picture text -----**<br> 1Transfer Function “A” is shown. See Figure 1 for other available transfer function options. **5** Sensing and Internet of Things ## **Force Sensors, FSA Series Compensated/Amplified** ## Figure 3. Mounting Dimensions (For reference only: mm/in.) Analog version **==> picture [121 x 76] intentionally omitted <==** **==> picture [363 x 284] intentionally omitted <==** **----- Start of picture text -----**<br> 25,02<br>[0.99]<br>23,57<br>[0.93]<br> ø [0.5]12,70 [0.07]1,79 [0.14]3,68<br>6,11 3X 2,54 3X 0,63<br>[0.24] [0.1] [0.02]<br>[0.23]5,74 17,36[0.68] [0.22]5,7<br>Pin 1<br>3X 6,48<br> [0.26]<br>12,19<br>[0.48] Plunger<br>3X 1,31<br> [0.05] 3X 0,61<br> [0.02] 7,1 8,25<br>2X 3,94 [0.28] [0.32]<br> [0.15]<br>Function Pin 1 Pin 2 Pin 3<br>analog Vsupply Vout GND<br>**----- End of picture text -----**<br> ## Digital version **==> picture [117 x 78] intentionally omitted <==** **==> picture [346 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> 25,02<br>[0.99]<br>23,57<br>[0.93]<br> ø12,70 [0.07]1,79 3,68<br> [0.5] [0.14]<br>3,57 5X 0,63<br>[0.14] [0.02]<br>4X 2,54<br>5,74 [0.1] 17,36 5,7<br>[0.23] [0.68] [0.22]<br>Pin 1<br>12,19<br>[0.48] Plunger<br>5X 1,31<br> [0.05] 5X 0,61<br> [0.02] 7,1 8,25<br>2X 3,94 [0.28] [0.32]<br> [0.15]<br>5X 6,48<br> [0.26]<br>**----- End of picture text -----**<br> |Function|Pin 1|Pin 2|Pin 3|Pin 4|Pin 5| |---|---|---|---|---|---| |SPI|GND|Vsupply|SS|MISO|SCLK| |I<br>2C|GND|Vsupply|N/C|SDA|SCL| **6** Sensing and Internet of Things ## ADDITIONAL INFORMATION The following associated literature is available on the Honeywell web site at sensing.honeywell.com: - Product Range Guide - Product Line Guide - Product Installation Instructions ## **WARNING PERSONAL INJURY** DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. - Technical Information: - SPI Communications with Honeywell Digital Output Force Sensors - I[2] C Communications with Honeywell Digital Output Force Sensors ## **WARNING** ## **MISUSE OF DOCUMENTATION** - The information presented in this datasheet is for reference only. Do not use this document as a product installation guide. - Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. ## Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. ## Find out more Honeywell serves its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. To learn more about Honeywell’s sensing and switching products, call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com ## Honeywell Sensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707 honeywell.com 32311096-B-EN | B | 1/17 © 2017 Honeywell International Inc. All rights reserved.
Updated at February 9, 2023
Honeywell is a globally recognized leader in the design and manufacture of advanced sensing and switching solutions. Renowned for engineering components that deliver enhanced precision and ruggedness, Honeywell provides essential technologies for demanding applications across critical healthcare, aerospace, and industrial equipment. With a comprehensive portfolio built to address both basic and complex design challenges, the company stands at the forefront of reliable electronic component manufacturing. The core of our Honeywell offering is an extensive selection of high-performance sensors and transducers. This includes a robust lineup of pressure sensors and transducers engineered for accurate fluid and gas measurement in challenging environments. Furthermore, we provide a wide array of temperature sensors and specialized temperature sensing NTC thermistors designed for stable thermal management, alongside precision current sensors and load cells that deliver critical feedback for control systems. Beyond advanced sensing technology, Honeywell’s expertise extends to essential circuit protection and electromechanical components. Our selection encompasses power relays, thermal magnetic circuit breakers, and standard terminal blocks, ensuring safe and efficient power distribution. Whether integrating core components or sourcing specialized accessories, design engineers can rely on Honeywell for uncompromising quality and operational excellence.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.