FLUKE-1738/FPC EU
Data Logger, w/ 1Yr Premium Care, Three-Phase Power Quality, 12 Channel
- Manufacturer: FLUKE
- Product type:
- SVHC: No SVHC (27-Jun-2024)
- Display Type: LCD
- Product Range: -
- Data Interface: Bluetooth & WiFi, USB
- Maximum Samples: -
- Data Logger Type: Three-Phase Power Quality
- No. of Channels / Inputs: 12 Channel
- Sensor / Measurement Type: Current, Energy, Frequency, Harmonics, Power, Power Factor, Voltage
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 6024.75 € |
| Current stock | 10+ |
| Lead time | 30 days |
## TECHNICAL DATA ## Fluke 1736 and 1738 Three-Phase Power Loggers ## **More visibility, reduced uncertainty and better power quality and energy consumption decisions** The Fluke 1736 and 1738 Three-Phase Power Loggers built with Fluke Connect[®] mobile app and desktop software compatibility give you the data you need to make critical power quality and energy decisions in real-time. The ideal test tools for conducting energy studies and basic power quality logging, the 1736 and 1738 automatically capture and log over 500 power quality parameters so you have more visibility into the data you need to optimize system reliability and savings. ## **Key measurements** Automatically capture and log voltage, current, power, harmonics and associated power quality values ## **FluKe ConneCt[®] Compatible*** View data locally on the instrument, via Fluke Connect mobile app and desktop software or through your facilities’ WiFi infrastructure. ## **Convenient instrument powering** Power instrument directly from the measured circuit ## **HigHest saFety rating in tHe industry** 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream An optimized user interface, flexible current probes, and an intelligent measurement verification function that allows you to reduce measurement errors by digitally verifying and correcting common connection errors makes setup easier than ever and reduces measurement uncertainty. Access and share data remotely with your team via the Fluke Connect[®] app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins. You can also quickly and easily chart and graph measurements to help identify issues and create detailed reports with the included Fluke Energy Analyze Plus software package. - Measure all three phases and neutral with included 4 flexible current probes. - Comprehensive logging: More than 20 separate logging sessions can be stored on the instruments. In fact, all measured values are automatically logged so you never loose measurement trends. They can even be reviewed during logging sessions and before downloading for real-time analysis. - Capture dips, swells, and inrush currents: includes event waveform snapshot and high resolution RMS profile, along with date, timestamp and severity to help pinpoint potential root causes of power quality issues. - Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display. - Optimized user interface: Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function. - Complete “in-the-field” setup through the front panel or Fluke Connect App: no need to return to the workshop for download and setup or to take a computer to the electrical panel. *Not all models are available in all countries. Check with your local Fluke representative. - Fully integrated logging: Connect other Fluke Connect devices to the Fluke 1738 to simultaneously log up to two other measurement parameters, virtually any parameter available on a Fluke Connect wireless digital multimeter or module.* - Energy Analyze Plus application software: Download and analyze every detail of energy consumption and power quality state of health with our automated reporting. *Not all models are available in all countries. Check with your local Fluke representative. ## **Applications** Load studies: verify electrical system capacity before adding loads Energy assessments: quantify energy consumption before, and after improvements, to justify energy saving devices Conduct multiple studies with one instrument; download while studies are in progress via USB stick or Fluke Connect mobile app. Suitable for NEC 220 load studies Harmonics measurements: uncover harmonic issues that can damage or disrupt critical equipment Discover the source of voltage and current distortion that may be affecting your equipment Voltage and current event capture: monitor for dips, swells and inrush currents that cause false resets or nuisance circuit breaker tripping Capture voltage events and inrush currents with pre-defined thresholds ## Log the most common parameters Designed to measure the most critical threephase power parameters, the 1736 and 1738 can simultaneously log rms voltage, rms current, voltage and current events, voltage and current THD, voltage and current harmonics up to the 50th harmonic, active power, reactive power, power factor, active energy, reactive energy, and more. With enough memory for more than a year of data logging, the 1736 and 1738 can uncover intermittent or hard-to-find issues that might otherwise have been missed. Simple setup means all available measured parameters are automatically selected during logging so you can be sure you have the data you need, even before you know you need it 2 Fluke Corporation Fluke 1736 and 1738 Three-Phase Power Loggers ## **Easy to use** The four current probes are connected separately; the instrument automatically detects and scales the probes. The thin current probes are designed to easily get through tight conductor spacing and are easily set to 150 or 1500 A for high accuracy in nearly any application. An innovative tangle-free flat voltage lead makes connection simple and reliable and the instrument’s intelligent ‘Verify Connection’ feature automatically checks to make sure the instrument is connected correctly and can digitally correct common connection issues without having to disconnect measurement leads. ## **Analysis and Reporting** Capturing logged data is just one part of the task. Once you have the data, you need to create useful information and reports that can be easily shared and understood by your organization or customers. Fluke Energy Analyze Plus software makes that task as simple as possible. With powerful analysis tools and the ability to create customized reports in minutes you’ll be able to communicate your findings and quickly solve problems so you can optimize system reliability and savings. The detachable power supply can be conveniently and safely powered directly from the measured circuit—no more searching for power outlets or having to run multiple extension cords to the logging location. Quickly and easily compare any measured parameter Intelligent verification function that digitally corrects most common measurement connections ## Data downloading couldn’t be easier or more flexible: - Download directly to a USB flash drive that plugs directly into the USB port of the instrument - View measurements remotely via the Fluke Connect mobile app and desktop software, helping you maintain safer working distances and reducing the need for personal protective equipment and unnecessary site visits and check-ins* *Not all models are available in all countries. Check with your local Fluke representative. 3 Fluke Corporation Fluke 1736 and 1738 Three-Phase Power Loggers **==> picture [117 x 35] intentionally omitted <==** ## **specifications** **==> picture [439 x 297] intentionally omitted <==** **----- Start of picture text -----**<br> Accuracy<br>Parameter Range Max. resolution Intrinsic accuracy at reference conditions<br>(% of reading + % of full scale)<br>Voltage 1000 V 0.1 V ± (0.2 % + 0.01 %)<br>150 A 0.1 A ± (1 % + 0.02 %)<br>i17xx-flex 1500 12”<br>1500 A 1 A ± (1 % + 0.02 %)<br>300 A 1 A ± (1 % + 0.03 %)<br>i17xx-flex 3000 24”<br>3000 A 10 A ± (1 % + 0.03 %)<br>Current<br>600 A 1 A ± (1.5 % + 0.03 %)<br>i17xx-flex 6000 36”<br>6000 A 10 A ± (1.5 % + 0.03 %)<br>4 A 1 mA ± (0.7 % + 0.02 %)<br>i40s-EL clamp<br>40 A 10 mA ± (0.7 % + 0.02 %)<br>Frequency 42.5 Hz to 69 Hz 0.01 Hz ± (0.1 %)<br>Aux input ± 10 V dc 0.1 mV ± (0.2 % + 0.02 %)<br>Voltage min/max 1000 V 0.1 V ± (1 % + 0.1 %)<br>defined by defined by<br>Current min/max ± (5 % + 0.2 %)<br>accessory accessory<br>THD on voltage 1000 % 0.1 % ± 0.5<br>THD on current 1000 % 0.1 % ± 0.5<br>Voltage harmonics 2nd ... 1000 V 0.1 V ≥ 10 V: ± 5 % of reading<br>50th < 10 V: ± 0.5V<br>Current harmonics 2nd ... defined by defined by ≥ 3 % of current range: ± 5 % of reading<br>50th accessory accessory < 3 % of current range: ± 0.15 % of range<br>Unbalance 100 % 0.1 % ± 0.2<br>**----- End of picture text -----**<br> **==> picture [438 x 162] intentionally omitted <==** **----- Start of picture text -----**<br> Intrinsic uncertainty ± (% of reading + % of range) [1]<br>Influence iFlex1500-12 iFlex3000-24 iFlex6000-36 i40s-EL<br>Parameter<br>quantity 150A/1500A 300A/3000A 600/6000A 4A/40A<br>Active Power P 1.2 % + 1.7 % +<br>PF ≥ 0.99 1.2 % + 0.005 % 1.2 % + 0.005 %<br>Active Energy Ea 0.0075 % 0.0075 %<br>Apparent Power S 0 ≤ PF ≤ 1 1.2 % + 0.005 % 1.2 % + 1.7 % + 1.2 % + 0.005 %<br>Apparent Energy Eap 0.0075 % 0.0075 %<br>Reactive Power Q<br>0 ≤ PF ≤ 1 2.5 % of measured apparent power<br>Reactive Energy Er<br>Power Factor PF<br>Displacement Power – ± 0.025<br>FactorDPF/cosϕ<br>Additional uncertainty in % of range [1] VP-N > 250 V 0.015 % 0.0225 % 0.0225 % 0.015 %<br>**----- End of picture text -----**<br> 1Range = 1000 V x Irange Reference conditions: **•** Environmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 % **•** Input conditions: Cosϕ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %. **•** Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V Input current: I > 10 % of Irange **•** Primary conductor of clamps or Rogowski coil in center position **•** Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C 4 Fluke Corporation Fluke 1736 and 1738 Three-Phase Power Loggers **==> picture [117 x 35] intentionally omitted <==** **==> picture [439 x 521] intentionally omitted <==** **----- Start of picture text -----**<br> Electrical specifications<br>Power supply<br>100 V to 500 V using safety plug input when powering from the<br>Voltage range measurement circuit<br>100 V to 240 V using standard power cord (IEC 60320 C7)<br>Power consumption Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)<br>Efficiency ≥ 68.2 % (in accordance with energy efficiency regulations)<br>Maximum no-load consumption < 0.3 W only when powered using IEC 60320 input<br>Mains power frequency 50/60 Hz ± 15 %<br>Battery Li-ion 3.7 V, 9.25 Wh, customer-replaceable<br>On-battery runtime Four hours in standard operating mode, up to 5.5 hours in power saving mode<br>Charging time < 6 hours<br>Data acquisition<br>Resolution 16-bit synchronous sampling<br>Sampling frequency 10.24 kHz at 50/60 Hz, synchronized to mains frequency<br>Input signal frequency 50/60 Hz (42.5 to 69 Hz)<br>1-ϕ, 1-ϕ IT, split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕ<br>Circuit types<br>Aron/Blondel (2-element delta), 3-ϕ delta open leg, currents only (load studies)<br>Data storage Internal flash memory (not user replaceable)<br>Memory size Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events [1]<br>Basic interval<br>Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental<br>Measured parameters<br>power, DPF, energy<br>Averaging interval User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min<br>Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to<br>Averaging time min/max values IEC61000-4-30<br>Aux, Power: 200ms<br>Demand Interval (Energy Meter Mode)<br>Measured parameters Energy (Wh, varh, VAh), PF, maximum demand, cost of energy<br>Interval User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off<br>Power quality measurements<br>Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD<br>Measured parameter<br>A, TDD<br>Averaging interval 10 min<br>Individual harmonics 2nd ...50th harmonic<br>Total harmonic distortion Calculated on 50 harmonics<br>Events Voltage: dips, swells, interruptions, current: inrush current<br>Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according<br>Triggered recordings to IEC61000-4-30)<br>Waveform of voltage and current<br>**----- End of picture text -----**<br> 1The number of possible logging sessions and logging period depends on user requirements. 5 Fluke Corporation Fluke 1736 and 1738 Three-Phase Power Loggers **==> picture [117 x 35] intentionally omitted <==** **==> picture [439 x 546] intentionally omitted <==** **----- Start of picture text -----**<br> Electrical specifications cont.<br>Standards Compliance<br>IEC 61000-4-7: Class 1<br>Harmonics<br>IEEE 519 (short time harmonics)<br>Power quality IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device)<br>Power IEEE 1459<br>Power quality compliance EN50160 (for measured parameters)<br>Interfaces<br>USB-A File transfer via USB flash drive, firmware updates, max. supply current: 120 mA<br>WiFi File transfer and remote control via direct connection or WiFi infrastructure<br>Bluetooth Read auxiliary measurement data from Fluke Connect [®] 3000 series modules<br>(requires 1738, or 1736 upgrade option)<br>USB-mini Data download device to PC<br>Voltage inputs<br>Number of inputs 4 (3 phases and neutral)<br>Maximum input voltage 1000 Vrms, CF 1.7<br>Input impedance 10 MΩ<br>Bandwidth 42.5 Hz - 3.5 kHz<br>Scaling 1:1 and variable<br>Measurement category 1000 V CAT III/600 V CAT IV<br>Current inputs<br>Number of inputs 4, mode selected automatically for attached sensor<br>Input voltage Clamp input: 500 mVrms/50 mVrms; CF 2.8<br>150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal<br>Rogowski coil input<br>probe range<br>1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12”<br>3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24”<br>Range<br>6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36”<br>40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL<br>Bandwidth 42.5 Hz - 3.5 kHz<br>Scaling 1:1 and variable<br>Auxiliary inputs<br>Number of inputs 2<br>Input range 0 to ± 10 V dc, 1 reading/s<br>Scale factor Format: mx + b (gain and offset) user configurable<br>Displayed units User configurable (7 characters, for example, °C, psi, or m/s)<br>Wireless connection<br>Number of inputs 2<br>Supported modules Fluke Connect [®] 3000 series<br>Acquisition 1 reading/s<br>**----- End of picture text -----**<br> 6 Fluke Corporation Fluke 1736 and 1738 Three-Phase Power Loggers **==> picture [117 x 35] intentionally omitted <==** **==> picture [439 x 404] intentionally omitted <==** **----- Start of picture text -----**<br> Environmental specifications<br>Operating temperature -10 °C to +50 °C (14 °F to 122 °F)<br>Storage temperature -20 °C to +60 °C (−4 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F)<br>10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH<br>Operating humidity 30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH<br>40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH<br>Operating altitude 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)<br>Storage altitude 12,000 m<br>Enclosure IP50 in accordance with EN60529<br>Vibration MIL-T-28800E, Type 3, Class III, Style B<br>IEC 61010-1<br> IEC Mains Input: Overvoltage Category II, Pollution Degree 2<br>Safety Voltage Terminals: Overvoltage Category IV, Pollution Degree 2<br>IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V<br>EN 61326-1: Industrial CISPR 11: Group 1, Class A<br>Electromagnetic compatibility Korea (KCC): Class A Equipment (industrial broadcasting and<br>(EMC) communication equipment)<br>USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per<br>clause 15.103<br>Temperature coefficient 0.1 x accuracy specification/°C<br>General specifications<br>Color LCD display 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel<br>Instrument and power supply: Two-years (battery not included)<br>Warranty Accessories: one-year<br>Calibration cycle: two-years<br>Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)<br>Dimensions Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)<br>Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm<br>(7.8 in x 6.6 in x 3.5 in)<br>Instrument: 1.1 kg (2.5 lb)<br>Weight<br>Power supply: 400 g (0.9 lb)<br>Tamper protection Kensington lock slot<br>**----- End of picture text -----**<br> 7 Fluke Corporation Fluke 1736 and 1738 Three-Phase Power Loggers **==> picture [117 x 35] intentionally omitted <==** **==> picture [438 x 290] intentionally omitted <==** **----- Start of picture text -----**<br> i17xx-flex 1500 12” Flexible Current Probe specifications<br>Measuring range 1 to 150 A ac/10 to 1500 A ac<br>Nondestructive current 100 kA (50/60 Hz)<br>Intrinsic error at reference condition* ± 0.7 % of reading<br>Accuracy 173x + iFlex ± (1 % of reading + 0.02 % of range)<br>Temperature coefficient over operating temperature range 0.05 % of reading/°C 0.09 % of reading/°F<br>Working voltage 1000 V CAT III, 600 V CAT IV<br>Probe cable length 305 mm (12 in)<br>Probe cable diameter 7.5 mm (0.3 in)<br>Minimum bending radius 38 mm (1.5 in)<br>Output cable length 2 m (6.6 ft)<br>Weight 115 g<br>Probe cable material TPR<br>Coupling material POM + ABS/PC<br>Output cable TPR/PVC<br>-20 °C to +70 °C (-4 °F to 158 °F) temperature of<br>Operating temperature<br>conductor under test shall not exceed 80 °C (176 °F)<br>Temperature, non-operating -40 °C to +80 °C (-40 °F to 176 °F)<br>Relative humidity, operating 15 % to 85 % non-condensing<br>IP rating IEC 60529:IP50<br>Warranty One-year<br>**----- End of picture text -----**<br> - Reference condition: - Environmental: 23 °C ± 5 °C, no external electrical/magnetic field, RH 65 % - Primary conductor in center position 8 Fluke Corporation Fluke 1736 and 1738 Three-Phase Power Loggers **==> picture [117 x 35] intentionally omitted <==** ## **model features** **==> picture [514 x 592] intentionally omitted <==** **----- Start of picture text -----**<br> 1736 Power Logger 1738 Power Logger<br>FLUKE- FLUKE-1736/ FLUKE-1736/ FLUKE- FLUKE-1738/ FLUKE-1738/<br>1736/B EUS INTL 1738/B EUS INTL<br>Power logger Power logger<br>Model Power logger Power logger Power logger Power logger advanced advance advanced<br>basic version (EU and US) (International) version (EU version<br>version<br>and US) (International)<br>Functions<br>PQ Health (EN50160 analysis) Opt. Opt. Opt. • • •<br>IEEE 519 reporting Opt. Opt. Opt. Opt. Opt. Opt.<br>Fluke Connect [®] module support Opt. Opt. Opt. • • •<br>(up to 2 modules**)<br>Recording<br>Trend • • • • • •<br>Waveform Snapshots + RMS profile Opt. Opt. Opt. • • •<br>Communication<br>USB (mini B) • • • • • •<br>WiFi download of instrument data • • Opt. • • Opt.<br>WiFi download via WiFi access point<br>Opt. Opt. Opt. Opt. Opt. Opt.<br>(requires registration)**<br>Included Accessories<br>WiFi only adapter** - • - - - -<br>WiFi and BLE adapter** Opt. Opt. Opt. Opt. • Opt.<br>USB flash drive (4GB) • • • • • •<br>USB Cable • • • • • •<br>3PHVL-173 Flat Cable • • • • • •<br>1x red, 1x black 0.1m cable • • • • • •<br>1x red, 1x black 1.5m lead • • • • • •<br>Alligator clips 4 4 4 4 4 4<br>C173x Soft Case • • • • • •<br>Color Coding set • • • • • •<br>173x-Hanger kit Opt. Opt. Opt. • • •<br>MP1-Magnet Probe Opt. Opt. Opt. 4 4 4<br>i173X-flex1500 12” Opt. 4 4 Opt. 4 4<br>EU, UK, EU, UK, EU, UK, EU, UK,<br>Line cord EU, US, UK EU, US, UK<br>US, AU, BR US, AU, BR US, AU, BR US, AU, BR<br>Compatible Optional Accessories<br>173X- AUX analog adapter • • • • • •<br>i17XX-flex1500 12” Current Probe • • • • • •<br>i17XX-flex3000 24” Current Probe • • • • • •<br>i17XX-flex6000 36” Current Probe • • • • • •<br>i40s-EL Current Clamp • • • • • •<br>IEEE 519 reporting opt • • • • • •<br>1736 to 1738 upgrade (1736/UPGRADE) • • • – – –<br>**----- End of picture text -----**<br> * Modules not included ** Not all models are available in all countries. Check with your local Fluke representative. 9 Fluke Corporation Fluke 1736 and 1738 Three-Phase Power Loggers ## **ordering information**** FLUKE-1736/B Power Logger, Basic version (excludes current probes) FLUKE-1736/EUS Power Logger, EU and US version (includes current probes) FLUKE-1736/INTL Power Logger, International version (includes current probes) FLUKE-1736/WINTL Power Logger, International wireless version (includes current probes) FLUKE-1738/B Power Logger, Advanced version (excludes current probes) FLUKE-1738/EUS Power Logger, EU/US Advanced version (includes current probes) FLUKE-1738/INTL Power Logger, International advanced version (includes current probes) FLUKE-1738/WINTL Power Logger, International wireless version (includes current probes) ## **Fluke-1736 includes:** Instrument, power supply, voltage test leads, alligator clips (4x), 12 in 1,500A flexible current probe (4x), soft case, Energy Analyze Plus software, WiFi adapter**, line cords, color coding set and documentation on USB flash drive ## **see it. save it. share it. all the facts, right in the field.** Fluke Connect[®] with ShareLive™ video call is the largest system of software and wireless test tools that lets you stay in contact with your entire team without leaving the field*. The Fluke Connect software is compatible with the following devices: iPhone models 4S and up running iOS 8.0 or higher, iPad Air and iPad Mini (2nd generation) in an iPhone frame on iPad and iPod Touch (5th generation), HTC One and One M8 running Android 4.4.x or higher, LG G3 and Nexus 5 running Android 4.4.x or higher, Samsung Galaxy S4 running Android 4.3.x or higher, Samsung Galaxy S5 running Android 4.4.x or higher and works with over 30 different Fluke products—the largest system of connected test tools in the world. And more are on the way. Go to the Fluke website to find out more: www.flukeconnect.com. *Within provider’s wireless service area. ## **Download the app at:** ## **Fluke 1738 includes:** Instrument, power supply, voltage test leads, alligator clips (4x), 12 in 1,500A flexible current probe (4x), soft case, Energy Analyze Plus software, magnetic hanging strap, magnetic voltage probes (4x), WiFi/BLE adapter**, line cords, color coding set and documentation on USB flash drive **Not all models are available in all countries. Check with your local Fluke representative. Smartphone wireless service and data plan not included with purchase. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher, iPad (in an iPhone frame on iPad) and Galaxy S4, Nexus 5, HTC One running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc. Fluke Connect is not available in all countries. ## **Fluke.** _Keeping your world up and running._[®] Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands Web: www.fluke.co.uk For more information call: In Europe/M-East/Africa +31 (0)40 267 5100 or Fax +31 (0)40 267 5222 Modification of this document is not permitted without written permission from Fluke Corporation. Fluke (UK) Ltd. 52 Hurricane Way Norwich, Norfolk NR6 6JB United Kingdom Tel.: +44 (0) 20 7942 0700 Fax: +44 (0) 20 7942 0701 E-mail: industrial@uk.fluke.nl Web: www.fluke.co.uk ©2015 Fluke Corporation. Specifications subject to change without notice. 9/2015 Pub_ID: 13485-eng 10 Fluke Corporation Fluke 1736 and 1738 Three-Phase Power Loggers
Updated at June 4, 2026
Fluke Corporation is globally recognized as the premier manufacturer of electronic test tools and diagnostic software. Since its founding in 1948, the company has built an industry-leading reputation for producing rugged, reliable, and highly accurate instruments utilized by technicians, engineers, and electricians worldwide. Their solutions are essential for industrial maintenance, electrical testing, precision measurement, and quality control across diverse manufacturing and service sectors. While renowned for its comprehensive testing equipment, maintaining the safety and functionality of these high-performance tools requires precise circuit protection. Our selection of Fluke components primarily features specialized replacement fuses designed to meet the rigorous safety ratings of their test instruments. These precision-engineered fuses provide reliable overload protection, safeguarding both the user and the equipment during critical electrical testing and troubleshooting tasks. To support modern data management and device connectivity, our inventory also includes genuine Fluke cable assemblies, such as USB communication cables. These high-quality accessories allow professionals to seamlessly connect their advanced test equipment to software platforms, ensuring secure data logging, efficient reporting, and accurate process calibration analysis.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →