- Manufacturer: FULHAM
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: -
- Output Current: 1.4A
- LED Driver Mode: Constant Current
- Output Power Max: 45W
- Input Voltage Max: 240V
- Input Voltage Min: 220V
- Output Voltage Max: 50V
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 96.34 € |
| Current stock | 10+ |
| Lead time | 11 days |
0-10VDC Pulse DIM
**EL-T**
**02**
## **FHSAC1-230-45CE**
## **SPECIFICATIONS**
## **General Specifications**
|Input Voltage|2 0-240VAC, 50/60Hz<br>2|
|---|---|
|Input Current|0**.**27A Max.|
|Input Power|58W|
|Power Factor|>0.9|
|THD|0<br>2<br>%<br><|
|Standby Power|<0.5W|
|Output Type|SELV|
|Output Current|25014<br>A<br>m<br>-<br>0<br>0|
|Output Voltage Range|11-50VDC|
|Output Power|45W (1W to 6W @ Emergency)|
|Output runtime|Minimum 90min at 6W, Minimum 180 Minutes at 3W (Factory set for 3W / 180min)|
|Dimming Type|0-10V or Pulse DIM|
|Dimming Percentage|0%, 1%-100%|
|Number of Output Channels|1 Channel|
|RFI/EMI|EN 55015<br>.|
|Ambient Operating Temperature Range|0°C To 40°C(32°F To 104F°)|
|Sound Rating|A|
|Input Surge Protection|Line-Neutral kV, Line & Neutral-Ground kV<br>2<br>2|
|Protections|Output Open Circuit Protection|
||Overload Protection|
||Short-Circuit Protection|
||Battery Deep Discharge Protection|
||Over Temprature Protection|
|Service Life|50,000 hours|
|Self-Diagnostic|Factory Enabled|
|Safety Standards|IEC/EN 61347-1,IEC/EN 61347-2-7,IEC/EN 61347-2-13,IEC/EN 60598-1|
||IEC/EN 60598-2-22,IEC 62384,EN 62493,IEC / EN 62034|
||EN 61547,EN 55015 , EN 61000-3-2 , EN 61000-3-3|
## **Mechanical Data**
**Tolerance=±0.02"[0 5mm. ]**
Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years from the date of manufacture when properly installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham. com Specifications subject to change without notice.
**Page 1 of 7 2017-718-1 Rev A**
**IMPORTANT:** In order to maintain proper operation and warranty coverage, the battery must be recharged once per year prior to installation.
**==> picture [543 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
q FULHAI FHSAC1-230-45CE nt SELV<br>SPECIFICATIONS 4 Koo<br>**----- End of picture text -----**<br>
Figure 3
**==> picture [547 x 594] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 Figure 4<br>0-10V Linear Dimming Curve Vo vs lo(Max) Curve<br>" 7 14001200 FEEEEEEEN]NSE EEE<br>. IN NO<br>‘ SEPPEEEEEE|<br>~ = EP SSE<br>Eo , <<Se 1000 EEEa<br>—g3*©~~ 800 EEE EEE EES<br>1 2 EEE<br>A © 600 EEE EE EEEEEE<br>. Z SEPP EEEEE EEE<br>p anned we EEE EEE EEE EEE<br>) 1 2 3 4 5 6 7 8 9 10<br>10 20 30 40 50<br>Dimming Voltge (V) Output Voltage (Vdc)<br>5 Figure 6<br>Efficiency vs Output Voltage at 220Vac Power Factor vs Output Power<br>90 1,000<br>——— sm<br>=Ss56asaanZ ee—1000mA ©° 0.960 —230V<br>®iSZag4 7, Z| == 1250mA :.® 0.940<br>€ m. {e)<br>e Va "4 —1400mA 5<br>OV 82 Z| . 0.920<br>80 a 0.900<br>20 25 30 35 40 45 50 20 25 30 35 40 45<br>Output Voltage(Vdc) Output Power (W)<br>7 Figure 8<br>Lifetime vs Tcase THD vs Output Power<br>JESSSSSEEEEEEEEES SSS See<br>pe< 20 EEE<br>€ op OEE NEE EEE —rs 0v<br>©geog OEEEREEEE EEE Fis N<br>2 EEEEEEEPSSEEE (sé REE<br>Sy 40 aN z= 10 IN<br>20 SEE EEE EEESS eae<br>jSSS ee 5 | Ne<br>50 55 SSS 60 65 SSeSS5e5 70 75 80 85 90 0 eT<br>- 3 15 25 35 45<br>Tcase Output Power (W)<br>**----- End of picture text -----**<br>
Figure 5
**==> picture [31 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 7<br>**----- End of picture text -----**<br>
Fulham extendsa limited warranty to the original purchaser or first user for a period of ~~5 years~~ from the date of manufacture when properly installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham. com. Specifications subject to change without notice.
Page 3 of 7 2017-718-3 Rev A
q
FULHAI
FHSAC1-230-45CE nt SPECIFICATIONS ~~4~~
SELV
Koo
**==> picture [510 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
Figure 9 Figure 10<br>Default lo vs Tcase(driver) Default lo vs Ext.NTC Curve<br>100 oo 100 @<br>80 IN /<br>i22 | @= 806 PEPERAEE<br>eé 60 Be° OOOO<br>* & oll<br>; LEE EE 2 PEEEEEEEEEERE EEE EE<br>a Se EEEELEEEE EEE EEL EE<br>50 60 70 80 90 400 0123 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20<br>Tcase(°C) Resistor of Ext.NTC on Module (Kohm)<br>**----- End of picture text -----**<br>
Fulham extendsa limited warranty to the original purchaser or first user for a period of ~~5 years~~ from the date of manufacture when properly installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham. com. Specifications subject to change without notice.
Page 4 of 7 2017-718-4 Rev A
if HOTSPOTFULHAM FHSAC1-230-45CE "e>s C€ [5] SELV (a) SPECIFICATIONS ~~yd~~ Koo
**==> picture [491 x 281] intentionally omitted <==**
**----- Start of picture text -----**<br>
LED ARRAY<br>LED-|LED- le | _ O iO dO: O<br>Lu<br>LO NTC / PRG+ =e NTC/TPSB-100E<br>+& Lt <— | p SWITCHTEST _ (TheFulham test FHSWLPWH switch can be used Wall Plate.) together with<br>9 0-10V -/Pulse}<br>No octove/Pulse 0-10V/Pulse DIM<br>—<br>/ —____|_ 8<br>< L2<br>” 4 W ALL SWITCH L<br><I E GND<br>LL<br>FHSAC1-230-45CE<br>L E, - —o<br>0-10V ‘Pulse | —o Ef)<br>‘ Loop Out 0-10V+/Pulse<br>L2 Pulse Dimming switch<br>**----- End of picture text -----**<br>
Description: The Fulham FHSWLPWH Wall Plate can be used when remote mounting the Lighted Push Button Test Switch (LPBTS) next to the fixture, on the wall or in any location within the maximum remote mounting distance (15 meters) of the Lighted Push Button Test Switch (LPBTS).
**==> picture [129 x 82] intentionally omitted <==**
**----- Start of picture text -----**<br>
re<br>Wall plate and screw color:<br>white with black lettering<br>**----- End of picture text -----**<br>
Fulham extendsa limited warranty to the original purchaser or first user for a period of ~~5 years~~ from the date of manufacture when properly installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham. com. Specifications subject to change without notice.
Page 5 of 7 2017-718-5 Rev A
if HOTSPOT = @ FULHAM FHSAC1-230-45CE fa? C€ [5] SELV SPECIFICATIONS i ~~t~~ Kor
**==> picture [468 x 282] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Self-Diagnostic|tests|to|insure|the|unit|is|properly|functional|.|It|will|test|the|following|parameters:|
|*Battery-Checks|to|insure|battery|is|properly|connected|and|has|sufficient|capacity|for|180|
|minutes|when|set|to|1-3W|or|90|minutes|when|set|to|4W-6W|
|*LED|load-Insures|LED|load|is|connected|properly|and|functional.|
|*Charging|circuit-Insures|unit|charging|circuit|is|functioning|properly.|
|Any|errors|will|be|shown|via|the|indicator|light|as|per|the|table|below:|
|Slow|flashing|green|;|
|(1|sec|on|—|1|sec|off)|Self-Diagnostic process|underway|
|Flashing|Red|Battery|not connected,|check BAT pack|
|(4|sec|on|—1|sec|off)|
|Solid|Red|Load|failure,|check|EM|LED|load.|
|Slow|flashing|red|;|
|(1|sec|on|—1|sec|off)|Battery failure,|replace BAT|pack.|
|Fast|flashing|red|ee|;|
|(0,5|sec|on|—|0,5|sec|off)|Charge|circuit|error,|replace EM|Driver.|
|Both|Green|&|Red|off|EM|Mode|
**----- End of picture text -----**<br>
Any errors will be shown via the indicator light as per the table below:
## TEST SWITCH OPERATIONS:
## Emergency Test Mode
1. Press and Hold Test Button to test Emergency Mode. This can be done in all normal AC powered situations including dimmed to off and switched off.
## Manual Self-Diagnostic
1. Quickly Press Test Button 3 times within 3 seconds to manually activate Self-Diagnostic cycle. This will test the unit for 180 minutes when EM power set for 1W to 3W or for 90 minutes when EM power is set for 4W or 6W.
2. To Exit the Self-Diagnostic cycle, Press and Hold Test Button for 5 seconds
## Enable / Disable Auto Self-Diagnostic
1. Press and H old Test Button for 3 seconds 2. Release and Quickly Press Test Button 2 times
3. Press and Hold Test Button again for 3 seconds
4. Green Indicator on Test Button will flash for 5 seconds indicating the Enabled or Disabled Status : Short off/ Long on = Enabled Long off/ short on = Disabled
> Fulham extendsa limited warranty to the original purchaser or first user for a period of ~~5 years~~ from the date of manufacture when properly installed and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham. com. Specifications subject to change without notice.
Page6 of 7 2017-718-6 Rev A
https://www.fulham.com/PDFs/SpecSheets/Fulham-Design-Guide-Programmable-Drivers.pdf
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →