Image not available
Illustrative purposes only
ELG-200-C1750-3Y
LED Driver, LED Lighting, 199.5 W, 114 VDC, 1.75 A, Constant Current, 100 VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (25-Jun-2025)
- Product Range: ELG-200-C
- Output Current: 1.75A
- LED Driver Mode: Constant Current
- Output Power Max: 199.5W
- Input Voltage Max: 305VAC
- Input Voltage Min: 100VAC
- Output Voltage Max: 114VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 42.55 € |
| Current stock | 10+ |
| Lead time | 30 days |
**ELG - 200 - C series** 150~200W Constant Current Mode LED Driver ## ■ **==> picture [328 x 41] intentionally omitted <==** **----- Start of picture text -----**<br> IS 15885(Part 2/Sec13)<br>IP65 IP67 THOMAS SAMUEL THOMAS SAMUEL 8<br>® R-41027766 2 G@NMuv& fT CBce<br>(for 700A only)<br>■<br>**----- End of picture text -----**<br> ## ■ > ℃ ~+85 ℃ ## ■ **==> picture [358 x 78] intentionally omitted <==** **----- Start of picture text -----**<br> A<br>| IP67__| 3in1 dimming function (0~10Vdc, 10V PWM<br>Dx<br>| P67 _| Built-in Smarttimer dimming functionbyuserrequest.<br>**----- End of picture text -----**<br> _File Name:ELG-200-C-SPEC 2018-09-30_ 150~200W Constant Current Mode LED Driver ## **ELG - 200 - C series** ## **SPECIFICATION** |**MODEL**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**CURRENT ADJ. RANGE**<br>**SET UP TIME**<br>**Note.4**<br>**VOLTAGE RANGE**<br>**Note.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>(Please refer to "STATIC CHARACTERISTIC"<br>)<br>section<br>47 ~ 63Hz<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>1.8A / 115VAC 1.0A / 230VAC 1.0A/277VAC<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**CURRENT TOLERANCE**<br>±5.0%<br>**CONSTANT CURRENT REGION Note.2**<br>THD< 20%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>**TOTAL HARMONIC DISTORTION**<br>**OPEN CIRCUIT VOLTAGE(max.)**<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>COLD START 65A(twidth=<br>s measured at 50% Ipeak)/230VAC<br>680<br>Per NEMA 410<br>μ<br>;<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC<br>Tcase=-40 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**MAX. CASE TEMP.**<br>Tcase=+85℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:6KV,Line-Line:4KV);<br>EAC TP TC 020; KC KN15 KN61547<br>,<br>℃<br>℃<br>℃<br>℃<br>**CURRENT RIPPLE**<br>5.0% max. @rated current<br>100 ~ 305VAC 142 ~ 431VDC<br>No load power consumption <0.5W for Blank / A / Dx / D2-Type<br>**NO LOAD / STANDBY**<br>**POWER CONSUMPTION**<br>Standby power consumption <0.5W for B / AB / DA-Type<br>**ELG-200-C700**<br>**ELG-200-C1050**<br>**ELG-200-C1400**<br>**ELG-200-C1750**<br>**ELG-200-C2100**<br>700mA<br>1050mA<br>1400mA<br>1750mA<br>2100mA<br>200.2W<br>199.5W<br>198.8W<br>199.5W<br>201.6W<br>142 ~ 286V<br>95 ~ 190V<br>71 ~ 142V<br>57 ~ 114V<br>48 ~ 96V<br>300V<br>200V<br>160V<br>120V<br>105V<br>350 ~ 700mA<br>525 ~ 1050mA<br>700 ~ 1400mA<br>875 ~ 1750mA<br>1050 ~ 2100mA<br>93%<br>93%<br>92%<br>92%<br>92%<br>315 ~ 370V<br>205 ~ 250V<br>160 ~ 180V<br>125 ~ 150V<br>105 ~ 130V<br>2<br>*<br>*3<br>44 71<br>7.5 mm (L*W*H)<br>1.22Kg; 12pcs /15.2kg / 0.72CUFT<br>800ms/115VAC, 500ms/230VAC<br>Compliance to EN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3; GB17625.1, GB17743<br>≧<br>;<br>EAC TP TC 020; KC KN15 KN61547<br>,<br>958.9K hrs min. Telcordia SR-332 (Bellcore)<br>235Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>UL8750<br>independent, EN62384;<br>(type”HL”), CSA C22.2 No. 250.13-12;EN/AS/NZS 61347-1,EN/AS/NZS 61347-2-13<br>GB19510.14,GB19510.1;<br>;IP65 or IP67;<br>EAC TP TC 004;BIS IS15885(for 700A only)<br>KC61347 1 KC61347 2 13<br>- ,<br>- -<br>approved<br>200VAC ~ 305VAC<br>100VAC ~ 180VAC<br>150.5W<br>150.15W<br>149.8W<br>150.5W<br>151.2W<br>**DALI STANDARDS**<br>Compliance to IEC62386-101, 102, 207 for DA-Type only<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated currentand 25 _of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC’ sections for details.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. This series meetsthe typical lifeexpectancy of>50,000 hours of operation when Tcase, particularly(©)point (orTMP, per DLC), is about 85 _ or less.<br>7. Please refer to the warranty statement on MEAN WELL's website at ~~http:/Awww.meanwell.com~~<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>9. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf|**MODEL**<br>**RATED CURRENT**<br>**RATED POWER**<br>**OUTPUT**<br>**CURRENT ADJ. RANGE**<br>**SET UP TIME**<br>**Note.4**<br>**VOLTAGE RANGE**<br>**Note.3**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>(Please refer to "STATIC CHARACTERISTIC"<br>)<br>section<br>47 ~ 63Hz<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>1.8A / 115VAC 1.0A / 230VAC 1.0A/277VAC<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>Hiccup mode, recovers automatically after fault condition is removed<br>I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**CURRENT TOLERANCE**<br>±5.0%<br>**CONSTANT CURRENT REGION Note.2**<br>THD< 20%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>**TOTAL HARMONIC DISTORTION**<br>**OPEN CIRCUIT VOLTAGE(max.)**<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>COLD START 65A(twidth=<br>s measured at 50% Ipeak)/230VAC<br>680<br>Per NEMA 410<br>μ<br>;<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC<br>Tcase=-40 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**MAX. CASE TEMP.**<br>Tcase=+85℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:6KV,Line-Line:4KV);<br>EAC TP TC 020; KC KN15 KN61547<br>,<br>℃<br>℃<br>℃<br>℃<br>**CURRENT RIPPLE**<br>5.0% max. @rated current<br>100 ~ 305VAC 142 ~ 431VDC<br>No load power consumption <0.5W for Blank / A / Dx / D2-Type<br>**NO LOAD / STANDBY**<br>**POWER CONSUMPTION**<br>Standby power consumption <0.5W for B / AB / DA-Type<br>**ELG-200-C700**<br>**ELG-200-C1050**<br>**ELG-200-C1400**<br>**ELG-200-C1750**<br>**ELG-200-C2100**<br>700mA<br>1050mA<br>1400mA<br>1750mA<br>2100mA<br>200.2W<br>199.5W<br>198.8W<br>199.5W<br>201.6W<br>142 ~ 286V<br>95 ~ 190V<br>71 ~ 142V<br>57 ~ 114V<br>48 ~ 96V<br>300V<br>200V<br>160V<br>120V<br>105V<br>350 ~ 700mA<br>525 ~ 1050mA<br>700 ~ 1400mA<br>875 ~ 1750mA<br>1050 ~ 2100mA<br>93%<br>93%<br>92%<br>92%<br>92%<br>315 ~ 370V<br>205 ~ 250V<br>160 ~ 180V<br>125 ~ 150V<br>105 ~ 130V<br>2<br>*<br>*3<br>44 71<br>7.5 mm (L*W*H)<br>1.22Kg; 12pcs /15.2kg / 0.72CUFT<br>800ms/115VAC, 500ms/230VAC<br>Compliance to EN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3; GB17625.1, GB17743<br>≧<br>;<br>EAC TP TC 020; KC KN15 KN61547<br>,<br>958.9K hrs min. Telcordia SR-332 (Bellcore)<br>235Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>UL8750<br>independent, EN62384;<br>(type”HL”), CSA C22.2 No. 250.13-12;EN/AS/NZS 61347-1,EN/AS/NZS 61347-2-13<br>GB19510.14,GB19510.1;<br>;IP65 or IP67;<br>EAC TP TC 004;BIS IS15885(for 700A only)<br>KC61347 1 KC61347 2 13<br>- ,<br>- -<br>approved<br>200VAC ~ 305VAC<br>100VAC ~ 180VAC<br>150.5W<br>150.15W<br>149.8W<br>150.5W<br>151.2W<br>**DALI STANDARDS**<br>Compliance to IEC62386-101, 102, 207 for DA-Type only<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated currentand 25 _of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC’ sections for details.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. This series meetsthe typical lifeexpectancy of>50,000 hours of operation when Tcase, particularly(©)point (orTMP, per DLC), is about 85 _ or less.<br>7. Please refer to the warranty statement on MEAN WELL's website at ~~http:/Awww.meanwell.com~~<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>9. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf|**ELG-200-C700**|**ELG-200-C1050**|**ELG-200-C1400**|**ELG-200-C1750**|**ELG-200-C2100**| |---|---|---|---|---|---|---| ||**RATED CURRENT**|700mA|1050mA|1400mA|1750mA|2100mA| ||**RATED POWER**|200.2W<br>199.5W<br>198.8W<br>199.5W<br>201.6W<br>200VAC ~ 305VAC<br>100VAC ~ 180VAC<br>150.5W<br>150.15W<br>149.8W<br>150.5W<br>151.2W||||| ||**CONSTANT CURRENT REGION Note.2**|142 ~ 286V|95 ~ 190V|71 ~ 142V|57 ~ 114V|48 ~ 96V| ||**OPEN CIRCUIT VOLTAGE(max.)**|300V|200V|160V|120V|105V| ||**CURRENT ADJ. RANGE**|Adjustable for A/AB-Type only (via built-in potentiometer)<br>350 ~ 700mA<br>525 ~ 1050mA<br>700 ~ 1400mA<br>875 ~ 1750mA<br>1050 ~ 2100mA||||| ||**CURRENT RIPPLE**|5.0% max. @rated current||||| ||**CURRENT TOLERANCE**|±5.0%||||| ||**SET UP TIME**<br>**Note.4**|800ms/115VAC, 500ms/230VAC||||| ||**VOLTAGE RANGE**<br>**Note.3**|(Please refer to "STATIC CHARACTERISTIC"<br>)<br>section<br>100 ~ 305VAC 142 ~ 431VDC||||| ||**FREQUENCY RANGE**|47 ~ 63Hz||||| ||**POWER FACTOR (Typ.)**|PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)||||| ||**TOTAL HARMONIC DISTORTION**|THD< 20%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)||||| ||**EFFICIENCY (Typ.)**|93%|93%|92%|92%|92%| ||**AC CURRENT (Typ.)**|1.8A / 115VAC 1.0A / 230VAC 1.0A/277VAC||||| ||**INRUSH CURRENT(Typ.)**|COLD START 65A(twidth=<br>s measured at 50% Ipeak)/230VAC<br>680<br>Per NEMA 410<br>μ<br>;||||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC||||| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC||||| ||**NO LOAD / STANDBY**<br>**POWER CONSUMPTION**|No load power consumption <0.5W for Blank / A / Dx / D2-Type<br>Standby power consumption <0.5W for B / AB / DA-Type||||| ||**SHORT CIRCUIT**|Hiccup mode, recovers automatically after fault condition is removed||||| ||**OVER VOLTAGE**|Shut down o/p voltage, re-power on to recover<br>315 ~ 370V<br>205 ~ 250V<br>160 ~ 180V<br>125 ~ 150V<br>105 ~ 130V||||| ||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover||||| ||**WORKING TEMP.**|Tcase=-40 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃||||| ||**MAX. CASE TEMP.**|Tcase=+85℃||||| ||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +80<br>, 10 ~ 95% RH<br>℃||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)||||| ||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes||||| ||**SAFETY STANDARDS**|UL8750<br>independent, EN62384;<br>(type”HL”), CSA C22.2 No. 250.13-12;EN/AS/NZS 61347-1,EN/AS/NZS 61347-2-13<br>GB19510.14,GB19510.1;<br>;IP65 or IP67;<br>EAC TP TC 004;BIS IS15885(for 700A only)<br>KC61347 1 KC61347 2 13<br>- ,<br>- -<br>approved||||| ||**DALI STANDARDS**|Compliance to IEC62386-101, 102, 207 for DA-Type only||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||| ||**EMC EMISSION**|Compliance to EN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3; GB17625.1, GB17743<br>≧<br>;<br>EAC TP TC 020; KC KN15 KN61547<br>,||||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:6KV,Line-Line:4KV);<br>EAC TP TC 020; KC KN15 KN61547<br>,<br>,||||| ||**MTBF**|958.9K hrs min. Telcordia SR-332 (Bellcore)<br>235Khrs min. MIL-HDBK-217F (25<br>)<br>℃||||| ||**DIMENSION**|2<br>*<br>*3<br>44 71<br>7.5 mm (L*W*H)||||| ||**PACKING**<br>℃<br>℃<br>℃<br>℃<br>1.22Kg; 12pcs /15.2kg / 0.72CUFT<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated currentand 25 _of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC’ sections for details.<br>4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. This series meetsthe typical lifeexpectancy of>50,000 hours of operation when Tcase, particularly(©)point (orTMP, per DLC), is about 85 _ or less.<br>7. Please refer to the warranty statement on MEAN WELL's website at ~~http:/Awww.meanwell.com~~<br>8. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>9. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf|||||| of >50,000 hours of operation when Tcase, particularly(©) point (or TMP, per DLC), is about 85 ℃ _ or less. MEAN WELL's website at ~~http:/Awww.meanwell.com~~ ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating altitude higher than 2000m(6500ft). function installation caution, please refer our user manual before using. _File Name:ELG-200-C-SPEC 2018-09-30_ **ELG - 200 - C series** 150~200W Constant Current Mode LED Driver ## **BLOCK DIAGRAM** **==> picture [469 x 148] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 50~120KHz<br>PWM fosc : 60~130KHz<br>EMI FILTER PFC POWER RECTIFIERS Vo+<br>I/P & CIRCUIT SWITCHING & Vo-<br>RECTIFIERS FILTER<br>O.L.P. DIM+<br>DIM-<br>(B Type)<br>O.T.P. O.L.P. DETECTION<br>PWM & PFC CIRCUIT<br>CONTROL<br>PFC CONTROL<br>O.V.P.<br>CASE :Protective Earth<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** ※ This series works in constant current mode to directly drive the LEDs. **==> picture [219 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>Constant<br>Current area<br>50<br>(min.)<br>Hiccup<br>Protection<br>50 100 Io(%)<br>Typical output current normalized by rated current (%)<br>Vo(%)<br>**----- End of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. _File Name:ELG-200-C-SPEC 2018-09-30_ **ELG - 200 - C series** 150~200W Constant Current Mode LED Driver ## **DIMMING OPERATION** **==> picture [470 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 3 in 1 dimming function (for B/AB-Type)<br>DIM+(Gray)*<br>AC/N(Blue) ELG-200-C DIM-(Black)**<br>AC/L(Brown) Vo-(Blue)<br>Vo+(Brown)<br>* DIM+ for B/AB-Type<br>DA+ for DA-Type<br>PROG+ for D2-Type<br>�Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: * *DIM- for B/AB-Type<br>0 ~ 10VDC, or 10V PWM signal or resistance. DA- for DA-TypePROG- for D2-Type<br>�Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.<br>�Dimming source current from power supply: 100μA (typ.)<br>◎ Applying additive 0 ~ 10VDC 100%<br>**----- End of picture text -----**<br> **==> picture [443 x 482] intentionally omitted <==** **----- Start of picture text -----**<br> Applying additive 0 ~ 10VDC 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>+<br>Additive Voltage 30%<br>- 20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>Additive PWM signal 30%<br>20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>◎ Applying additive resistance: 100%<br>90%<br>Vo+ + + 80%<br>70%<br>-<br>Vo- - 60%<br>DIM+ 50%<br>40%<br>Additive Resistance<br>30%<br>DIM- 20%<br>“DO NOT connect "DIM- to Vo-" 10%<br>0%<br>Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.<br>2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> _File Name:ELG-200-C-SPEC 2018-09-30_ **ELG - 200 - C series** ## 150~200W Constant Current Mode LED Driver - ※ **DALI Interface (primary side; for DA-Type)** Apply DALI signal between DA+ and DA-. - DALI protocol comprises 16 groups and 64 addresses. First step is fixed at 8% of output. - ※ **Smart timer dimming function (for Dxx-Type by User definition)** MEAN WELL Smart timer dimming primarily provides the adaptive proportion dimming profile for the output constant current level to perform up to 14 consecutive hours. 3 dimming profiles hereunder are defined accounting for the most frequently seen applications. If other options may be needed, please contact MEAN WELL for details. Ex : ◎ D01-Type: the profile recommended for residential lighting 100iere | || ue | - || 40 30 20 10 a5 02:00 04:00 06:00 08:00 10:00 Operating Time(HH:MM) ||T1|T2|T3|T4| |---|---|---|---|---| |TIME**|06:00|07:00|11:00|---| |LEVEL**|100%|70%|50%|70%| **: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a residential lighting application adopts D01-Type, when turning on the power supply at 6:00pm, for instance: [1] The power supply will switch to the constant current level at 100% starting from 6:00pm. [2] The power supply will switch to the constant current level at 70% in turn, starting from 0:00am, which is 06:00 after the power supply turns on. [3] The power supply will switch to the constant current level at 50% in turn, starting from 1:00am, which is 07:00 after the power supply turns on. [4] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on. The constant current level remains till 8:00am, which is 14:00 after the power supply turns on. Ex: ◎ D02-Type: the profile recommended for street lighting 100_i | 80 70 | el | so 40 30 Set up for D02-Type in Smart timer dimming software program: ||T1|T2|T3|T4|T5| |---|---|---|---|---|---| |TIME**|01:00|03:00|8:00|11:00|---| |LEVEL**|50%|80%|100%|60%|80%| ## Operating Time(HH:MM) **: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a street lighting application adopts D02-Type, when turning on the power supply at 5:00pm, for instance: [1] The power supply will switch to the constant current level at 50% starting from 5:00pm. [2] The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on. [3] The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on. [4] The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on. [5] The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on. _File Name:ELG-200-C-SPEC 2018-09-30_ > 150~200W Constant Current Mode LED Driver **ELG - 200 - C series** |Ex:|◎|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||100||||||||||||||| |||90||||||||Set up for D03-Type in Smart timer dimming software program:|||||| |||80|||||||||||||| |Dimming Level(%)||70<br>60<br>50<br>40<br>30|||||||||TIME**<br>LEVEL**|01:30<br>T1<br>70%|T2<br>11:00<br>100%|T3<br>---<br>70%|| |||20|||||||||||||| |||10|||||||||||||| |||0|||||||||||||| |||00:00|02:00|04:00|06:00|08:00|10:00|12:00|14:00||||||| ||||||Operating Time(HH:MM)|Operating Time(HH:MM)|||||||||| **: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a tunnel lighting application adopts D03-Type, when turning on the power supply at 4:30pm, for instance: [1] The power supply will switch to the constant current level at 70% starting from 4:30pm. [2] The power supply will switch to the constant current level at 100% in turn, starting from 6:00pm, which is 01:30 after the power supply turns on. [3] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on. _File Name:ELG-200-C-SPEC 2018-09-30_ **ELG - 200 - C series** 150~200W Constant Current Mode LED Driver ## **OUTPUT LOAD vs TEMPERATURE(Note.7)** **==> picture [487 x 375] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>230VAC 230VAC 230VAC<br>input only input input only<br>60 only 60<br>40 40<br>20 20<br>-40 -25 0 10 20 30 50 60 70 (HORIZONTAL) -40 -25 0 20 45 55 65 75 85 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 75℃<br>100 1<br>90<br>0.98<br>80<br>75 0.96<br>70<br>110V (150W)<br>0.94<br>60 230V (200W)<br>277V (200W)<br>50 0.92<br>40 0.9<br>0.88<br>100 120 140 160 180 200 240 250 260 270 280 305 50% 60% 70% 80% 90% 100%<br>INPUT VOLTAGE (V) 60Hz LOAD<br>※De-rating is needed under low input voltage.<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>**----- End of picture text -----**<br> ## **TOTAL HARMONIC DISTORTION (THD)** ## **EFFICIENCY vs LOAD** ELG-200-C series possess superior working efficiency that up to 93% can be reached in field applications. **==> picture [101 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 700mA Model, Tcase at 75℃ 700mA Model, Tcase at 75℃℃<br>**----- End of picture text -----**<br> **==> picture [488 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 700mA Model,Tcase at 75℃ ※ 700mA Model, Tcase at 75℃ 700mA Model, Tcase at 75℃℃<br>95<br>20% 94<br>18%<br>93<br>16%<br>92<br>14%<br>91<br>12%10% 115VAC (150W) 90 110V230V (200W)(150W)<br>8% 230VAC(200W) 89 277V (200W)<br>6% 277VAC (200W) 88<br>4% 87<br>2% 86<br>0% 85<br>50% 60% 70% 80% 90% 100% 50% 60% 70% 80% 90% 100%<br>LOAD<br>LOAD<br>THD<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:ELG-200-C-SPEC 2018-09-30_ **ELG - 200 - C series** 150~200W Constant Current Mode LED Driver ## **LIFE TIME** **==> picture [382 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>20 30 40 50 60 70 80<br>LIFETIME(Kh)<br>**----- End of picture text -----**<br> **==> picture [38 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Tcase ( ℃ )<br>**----- End of picture text -----**<br> _File Name:ELG-200-C-SPEC 2018-09-30_ **ELG - 200 - C series** ## 150~200W Constant Current Mode LED Driver **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION<br>※ Blank-Type CASE NO.: 262A Unit:mm<br>244<br>233<br>300±20 220 300±20<br>AC/N(Blue) Vo-(Blue)<br>AC/L(Brown) tc 79 Vo+(Brown)<br>SJOW 17AWGx2C SJOW 17AWGx2C<br>&H05RN-F 1.0mm2 &H05RN-F 1.0mm2<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>※ A-Type<br>244<br>233<br>300±20 220 300±20<br>AC/N(Blue) Vo-(Blue)<br>AC/L(Brown) tc 79 Vo+(Brown)<br>SJOW 17AWGx2C SJOW 17AWGx2C<br>&H05RN-F 1.0mm2 &H05RN-F 1.0mm2<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>41.75<br>19<br>71 53.8<br>32<br>37 37.5<br>71 53.8<br>32<br>37 37.5<br>**----- End of picture text -----**<br> _File Name:ELG-200-C-SPEC 2018-09-30_ **ELG - 200 - C series** ## 150~200W Constant Current Mode LED Driver **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※ AB-Type<br>244<br>233<br>300±20 220 300±20<br>DIM+(Gray)<br>AC/N(Blue) DIM-(Black)<br>AC/L(Brown) tc 79 Vo-(Blue)<br>SJOW 17AWGx2C Vo+(Brown)<br>&H05RN-F 1.0mm2 &H05RN-F 1.0mmSJOW 17AWGx2C2<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>41.75<br>※ B/DA/D2-Type<br>244<br>233<br>300±20 220 300±20<br>DIM+(Gray)*<br>AC/N(Blue) DIM-(Black)**<br>AC/L(Brown) tc 79 Vo-(Blue)<br>SJOW 17AWGx2C Vo+(Brown)<br>&H05RN-F 1.0mm2 &H05RN-F 1.0mmSJOW 17AWGx2C2<br>4-ψ4.5 * DIM+ for B-Type<br>DA+ for DA-Type<br>�tc : Max. Case Temperature * *DIM- for B-TypePROG+ for D2-Type<br>DA- for DA-Type<br>PROG- for D2-Type<br>19<br>71 53.8<br>32<br>37 37.5<br>71 53.8<br>32<br>37 37.5<br>**----- End of picture text -----**<br> _File Name:ELG-200-C-SPEC 2018-09-30_ **ELG - 200 - C series** ## 150~200W Constant Current Mode LED Driver **==> picture [399 x 191] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 3Y Model (3-wire input)<br>244<br>233<br>300±20 220<br>AC/N(Blue)<br>AC/L(Brown) tc 79<br>PE ( Green/Yellow) SJOW 17AWGx3C SJOW 17AWGx2C<br>&H05RN-F 1.0mm2 &H05RN-F 1.0mm2<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>◎ Note1: Please connect the case to PE for the complete EMC deliverance and safety use.<br>◎ Note2: Please contact MEAN WELL for input wiring option with PE.<br>71 53.8<br>32<br>**----- End of picture text -----**<br> ## **Installation Manual** **==> picture [177 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Please refer to : http://www.meanwell.com/manual.html<br>**----- End of picture text -----**<br> _File Name:ELG-200-C-SPEC 2018-09-30_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →