ECE60US12
AC/DC PCB Mount Power Supply (PSU), ITE, 1 Output, 60 W, 12 VDC, 5 A
- Manufacturer: XP POWER
- Product type: AC / DC PCB Mount Power Supplies
- No. of Outputs:1 Output; Output Power Max:60W; Output Voltage - Output 1:12V; Output Current - Output 1:5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Output
- SVHC: No SVHC (15-Jan-2018)
- Depth: 91.4mm
- Width: 38.1mm
- Height: 28mm
- Product Range: ECE60 Series
- No. of Outputs: 1 Output
- Output Power Max: 60W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 58.46 € |
| Current stock | 10+ |
| Lead time | 30 days |
## 60 Watts - Ultra Compact Size - Single Outputs from 3.3 to 48 V - Encapsulated - PCB & Chassis Mount Versions - <0.3 W No Load Input Power - -40 to +70 °C Operation - Peak Load Capability - 3 Year Warranty The ECE60 series of compact encapsulated AC-DC power modules are available in both PCB & chassis mount versions offering exceptional power density of >10W/in[3] . Output voltages are available from 3.3 – 48 VDC and these “green power” modules offer high active mode efficiency and low no load power consumption. They also provide a peak load capability up to 130% of nominal power for up to 30s and a wide operating temperature range from -40 to +70°C. Dimensions: ECE60: 3.60 x 1.50 x 1.10” (91.4 x 38.1 x 28.0 mm) ECE60-S: 4.45 x 1.57 x 1.12” (113.0 x 40.0 x 28.5 mm) Models & Ratings |Output Power|Output Voltage|Output Current<br>Po|Output Current<br>Po|Efficiency(4)|Model Number(2,3)| |---|---|---|---|---|---| |||Nominal<br>~~ee~~|Peak(1)<br>~~ee~~||| |33 W|3.3 V|10.00 A|13.00 A|79%|ECE60US03| |50 W|5.0 V|10.00 A|13.00 A|83%|ECE60US05| |60 W|9.0 V|6.67 A|8.67 A|87%|ECE60US09| |60 W|12.0 V|5.00 A|6.50 A|87%|ECE60US12| |60 W|15.0 V|4.00 A|5.20 A|88%|ECE60US15| |60 W|24.0 V|2.50 A|3.25 A|89%|ECE60US24| |60 W|36.0 V|1.67 A|2.17 A|88%|ECE60US36| |60 W|48.0 V|1.25 A|1.63 A|86%|ECE60US48| ## ~~**Notes**~~ _1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal power._ _2. Add suffix -S to model number to denote chassis mount with screw terminal type, e.g. ECE60US12-S._ _3. A screw terminal version (-S) is available with DIN Clip attached. Add suffix ‘D’, e.g. ECE60US24-SD. DIN Rail mounting clip is available as a separate item, order code ECE60 DIN CLIP._ _4. Average of efficiencies measured at 25%, 50%, 75% & 100% load with 230 VAC input._ ## Summary |Characteristic|Minimum|Typical|Maximum|Units|Notes & Conditions| |---|---|---|---|---|---| |Input Range|85||264|VAC|Derate load from 100% at 90 VAC to 90% at 85 VAC| ||120||370|VDC|| |No Load Input Power||<0.3||W|12-36 V versions| |||<0.5||W|3.3-9 V & 48 V versions| |Efficiency|79|87|89|%|See note 4 above| |Operating Temperature|-40||+70|°C|Some specification parameters may not met below -25 °C.<br>Derate linearly from 100% load at +50 °C to 50% load at<br>70 °C.| |EMC|EN55032 Level B Conducted & Radiated, EN61000-4, EN61000-3||||| |Safety Approvals|IEC / EN / UL 62368-1, CSA per cUL||||| **www.xppower.com** 1 |Input| |---| |Characteristic<br>Minimum<br>Typical<br>Maximum<br>Units<br>Notes & Conditions<br>Input Voltage - Operating<br>85<br>264<br>VAC<br>Derate load from 100% at 90 VAC to 90% at 85 VAC<br>120<br>370<br>VDC<br>Input Frequency<br>47<br>63<br>Hz<br>~~po~~<br>~~ce~~<br>~~ce ee ee~~<br>~~a~~<br>~~pf~~| |Power Factor<br>EN61000-3-2 class A compliant<br>~~eG~~<br>~~GO~~| |Input Current<br>0.6<br>A rms<br>At 230 VAC<br>No Load Input Power<br>0.3<br>W<br>12-36 V versions<br>0.5<br>W<br>3.3-9 V & 48 V versions<br>Inrush Current<br>25/50<br>A<br>115/230 VAC cold start at 25 °C<br>~~pf~~<br>~~ce~~<br>~~ee ee ee~~<br>~~eG~~<br>~~eG~~<br>~~GG~~| |Earth Leakage Current<br>Class II construction no earth<br>~~OG~~<br>~~DO~~| |Input Protection<br>Internal T2.5 A/250 VAC fuse<br>~~a~~| |Output| |Characteristic<br>Minimum<br>Typical<br>Maximum<br>Units<br>Notes & Conditions<br>Output Voltage<br>3.3<br>48<br>VDC<br>See Models and Ratings table<br>~~po~~<br>~~Ge~~| |Initial Set Accuracy<br>±1<br>%<br>~~a~~| |Minimum Load<br>0<br>A<br>Start Up Delay<br>2<br>s<br>Start Up Rise Time<br>30<br>ms<br>~~eG~~<br>~~es~~<br>~~a OG~~| |Hold Up Time<br>16<br>ms<br>At full load and 115 VAC<br>~~Ge~~| |Line Regulation<br>±0.5<br>%<br>Load Regulation<br>±2<br>%<br>ECE60US03/05-S<br>±1<br>%<br>All other models<br>Transient Response<br>4<br>%<br>Recovery within 1% in less than 500μs<br>for a 25% load change<br>Ripple & Noise<br>60<br>mV pk-pk<br>3.3-5 V versions, 20 MHz bandwidth<br>75<br>mV pk-pk<br>3.3-5 V ‘-S’ versions, 20 MHz bandwidth,<br>0.1μF capacitor at output terminals<br>1<br>% pk-pk<br>20 MHz bandwidth all other models<br>Overvoltage Protection<br>195<br>216<br>% Vnom<br>ECE60US03 models<br>115<br>140<br>% Vnom<br>All other models<br>Overload Protection<br>110<br>180<br>%<br>Short Circuit Protection<br>Trip & restart (hiccup mode)<br>~~ace~~<br>~~ee ee~~<br>~~PeOG~~<br>~~I cee eee ee ee~~<br>~~eG~~<br>~~ey~~<br>~~pt~~<br>~~GD~~<br>~~(O~~<br>~~Ge~~<br>~~eG~~<br>~~a~~| |Temperature Coefficient<br>0.05<br>%/˚C<br>~~Ge~~| ## General |Characteristic<br>a|Minimum|Typical<br>GO|Maximum<br>GO|Units<br> ~~CG~~|Notes & Conditions<br>~~CG~~| |---|---|---|---|---|---| |Efficiency<br>~~po~~|79<br>~~po~~|87<br>~~po~~|89<br>~~po~~|%<br>~~po~~|See Models & Ratings table<br>~~po~~| |Isolation<br>~~pf~~|3000<br>~~pf~~|~~pf~~|~~pf~~|VAC<br>~~pf~~|Input to Output<br>~~pf~~| |Switching Frequency<br>~~a~~|~~GG~~|100<br>~~GG~~|~~GG~~|kHz|| |Power Density<br>~~po~~|~~po~~|~~po~~|10.1<br>~~po~~|W/in3<br>~~po~~|~~po~~| |Mean Time Between Failure<br>~~pT~~<br>~~a~~|~~pT~~<br>~~ca~~|>300<br>~~pT~~<br>~~ce~~|~~pT~~<br>~~ee~~|kHrs<br>~~pT~~<br>~~ee~~|MIL-HDBK-217F, +25 °C GB<br>~~pT~~<br>~~ee~~| |Weight<br>~~a~~<br>~~a~~|~~ca~~|0.42 (191)<br>~~ce~~|~~ee~~|lb (g)<br>~~ee~~|ECE60<br>~~ee~~| ||~~ca~~<br>~~a~~|0.44 (200)<br>~~ce~~|~~ee~~|~~ee~~|ECE60-S<br>~~ee~~| ## Environmental |Characteristic|Minimum|Typical|Maximum|Units|Notes & Conditions| |---|---|---|---|---|---| |Operating Temperature|-40||+70|°C|Some specification parameters may not met below -25 °C.<br>Derate linearly from 100% load at +50 °C to 50% load at 70 °C.| |Storage Temperature|-40||+85|°C|| |Cooling|||||Convection-cooled| |Humidity|||95|%RH|Non-condensing| |Operating Altitude|||5000|m|| |Vibration|2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins each cycle||||| **www.xppower.com** 2 ## EMC: Emissions |Phenomenon|Standard|Test Level|Criteria|Notes & Conditions| |---|---|---|---|---| |Conducted|EN55032|Class B||| |Radiated|EN55032|Class B||| |Harmonic Current|EN61000-3-2|||Class A| |Voltage Flicker|EN61000-3-3|||| ## EMC: Immunity |Phenomenon|Standard|Test Level|Criteria|Notes & Conditions| |---|---|---|---|---| |ESD|EN61000-4-2|3|A|| |Radiated|EN61000-4-3|10 V/m 80% mod|A|| |EFT|EN61000-4-4|3|A|| |Surges|EN61000-4-5|Installation Class 3|A|| |Conducted|EN61000-4-6|3|A|| |Dips and Interruptions|EN61000-4-11|DIP: 100% 10 ms<br>DIP: 30% 500 ms<br>INT: 100% 5000 ms|A<br>A<br>B|| ## Safety Approvals **==> picture [536 x 341] intentionally omitted <==** **----- Start of picture text -----**<br> Safety Agency Safety Standard Notes & Conditions<br>UL UL 62368-1 & CAN/CSA C22.2 No. 62368-1-14,<br>TUV EN62368-1:2014/A11:2017<br>CB IEC60950-1:2005 Ed 2 / IEC62368-1:2014<br>CE Meets all applicable directives<br>UKCA Meets all applicable legislation<br>Mechanical Details<br><= == —<br>ECE60 ECE60 Screw Terminal (-S)<br>3.60 (91.4) 0.50 0.18 (4.5) 4.09 (104.0) 4x ø0.14<br>0.139 (3.54) (12.7) (4x ø3.5)<br>, T 0.44 f :<br>ACN +Vo (11.2)<br>-Vo<br>1.50 1.18 ACN TOP VIEW 0.84<br>(38.1) (30.0) TOP VIEW -Vo 1.57 ACL (21.3) 1.20<br>0.159 (40.0) +Vo (30.5)<br>(4.05)<br>aoP 0.14 es ACL 3.32 (84.3) e eeeee 3.57 (90.7) e|<br>(3.55) 0.19<br>(4.8)<br>0.54 (13.8) 1º<br>7 hd<br>1.10 1.12<br>(28.0) (28.5)<br>4x ø 0.06 (ø1.5) 0.24 0.10 4.45 (113.0)<br>(6.2) (2.5)<br>0.4 (10.2) Optional<br>DIN clip<br>**----- End of picture text -----**<br> ## ~~**Notes**~~ 1. All dimensions in inches (mm). 2. Weight: ECE60: 0.42 lbs (191 g) ECE60-S: 0.44 lbs (200 g) 3. Tolerances: x.xx = ± 0.02 (x.x = ± 0.5), x.xxx = ± 0.01 (x.xx = ± 0.25) **www.xppower.com** 27 January 2022 3
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →