Image not available
Illustrative purposes only
E3ZM20
Analogue Timer, ENYA, Multifunction, 1 s, 100 h, 7 Ranges, 1 Changeover Relay
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TELE
- Product type: Analogue Timers - DIN Rail
- Product Range:ENYA Series; Timer Functions:Multifunction; Time Min:1s; Time Max:100h; No. of Timing Ranges:7Ranges; Timer Output:1 Changeover Relay; Supply Voltage Max:240V; Current Rating Nom:8A;
- SVHC: No SVHC (21-Jan-2025)
- Time Max: 100h
- Time Min: 1s
- Timer Output: 1 Changeover Relay
- Product Range: ENYA
- Timer Functions: Multifunction
- Current Rating Nom: 8A
- Supply Voltage Max: 240V
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 57.29 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Timers - Multifunction** **E3ZM20** ENYA series 7 Functions 7 time ranges Wide input range 2 change over contacts Width 35mm Installation design ## **Technical data** ## **1. Functions** The function has to be set before connecting the relay to the supply voltage. E ON delay R OFF delay Ws Single shot leading edge with control input Wa Single shot trailing edge with control input Es ON delay with control input Wu Single shot leading edge voltage controlled Bp Flasher pause first ## **2. Time ranges** Time range Adjustment range 1s 50ms 1s 10s 500ms 10s 1min 3s 1min 10min 30s 10min 1h 3min 1h 10h 30min 10h 100h 5h 100h ## **6. Output circuit** 2 potential free change over contacts Rated voltage: 250V AC Switching capacity: 2000VA (8A / 250V) Fusing: 8A fast acting Mechanical life: 20 x 10[6] operations Electrical life: 2 x 10[5] operations at 1000VA resistive load Switching frequency: max. 6/min at 1000VA resistive load (in accordance with IEC 60947-5-1) Overvoltage category: III (in accordance with IEC 60664-1) 4kV Overvoltage category: Rated surge voltage: ## **7. Control input** Input not potential free: terminals A1-B1 Loadable: yes Max. line length: 10m Trigger level (sensitivity): automatic adaption to supply voltage Min. control pulse length: DC 50ms / AC 100ms ## **8. Accuracy** ## **3. Indicators** Green LED U/t ON: indication of supply voltage Green LED U/t flashes: indication of time period Yellow LED R ON/OFF: indication of relay output Base accuracy: ±1% of maximum scale value Adjusting accuracy: <5% of maximum scale value Repetition accuracy: <0.5% or ±5ms - Voltage influence: Temperature influence: ≤0.01% / °C ## **4. Mechanical design** Self-extinguishing plastic housing, IP rating IP40 Mounted on DIN-rail TS 35 according to EN 60715 Mounting position: any Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 Tightening torque: max. 1Nm Terminal capacity: 1 x 0.5 to 2.5mm² with/without multicore cable end 1 x 4mm² without multicore cable end 2 x 0.5 to 1.5mm² with/without multicore cable end 2 x 2.5mm² flexible without multicore cable end ## **9. Ambient conditions** -25 to +55°C Ambient temperature: -25 to +55°C Storage temperature: -25 to +70°C Transport temperature: -25 to +70°C Relative humidity: 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) Pollution degree: 2, if built in 3 (in accordance with IEC 60664-1) ## **10. Weight** Single packing: 106g ## **5. Input circuit** Supply voltage: 12 to 240V AC/DC Terminals: A1(+)-A2 Tolerance: -10% to +10% Rated consumption: 6VA (2W) Rated frequency: AC 48 to 63Hz Duty cycle: 100% Reset time: 100ms Residual ripple for DC: 10% Drop-out voltage: >30% of minimum rated supply voltage Overvoltage category: III (in accordance with IEC 60664-1) Rated surge voltage: 4kV **www.tele-online.com** **E3ZM20** ## **Functions** ## **ON delay (E)** When the supply voltage U is applied, the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay R switches into on-position (yellow LED illuminated). This status remains until the supply voltage is interrupted. If the supply voltage is interrupted before the expiry of the interval t, the interval already expired is erased and is restarted when the supply voltage is next applied. **==> picture [172 x 42] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>R t <t<br>**----- End of picture text -----**<br> ## **OFF delay (R)** The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the output relay R switches into on-position (yellow LED illuminated). If the control contact is opened, the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay switches into off-position (yellow LED not illuminated). If the control contact is closed again before the interval t has expired, the interval already expired is erased and is restarted. **==> picture [172 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>S <t<br>R t <t<br>**----- End of picture text -----**<br> ## **ON delay with control input (Es)** The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When teh control contact S is closed, the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay R switches into on-position (yellow LED illuminated). This status remains until the control contact is opened again. If the control contact is opened before the interval t has expired , the interval already expired is erased and is restarted with the next cycle. **==> picture [171 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>S<br>R t1 <t<br>**----- End of picture text -----**<br> ## **Single shot leading edge voltage controlled (Wu)** When the supply voltage U is applied, the output relay R switches into on-position (yellow LED illuminated) and the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay switches into off-position (yellow LED not illuminated). This status remains until the supply voltage is interrupted. If the supply voltage is interruted before the interval t has expired, the output relay switches into off-position. The interval already is erased and is restarted when the supply voltage is next applied. **==> picture [171 x 42] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>R t <t<br>**----- End of picture text -----**<br> ## **Flasher pause first (Bp)** ## **Single shot leading edge with control input (Ws)** The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the output relay R switches into on-position (green LED U/t illuminated) and the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay switches into off-position (yellow LED not illuminated). During the interval, the control contact can be operated any number of times. A further cycle can only be started when the cycle run has been completed. **==> picture [172 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>S<br>R t t<br>**----- End of picture text -----**<br> When the supply voltage U is applied, the set interval t begins (green LED U/t flashes). After the interval t has expired, the output relay R switches into on-position (yellow LED illuminated) and the set interval t begins again. After the interval t has expired, the output relay switches into off-position (yellow LED not illuminated). The output relay is triggered at a ratio of 1:1 until the supply voltage is interrupted. **==> picture [171 x 42] intentionally omitted <==** ## **Single shot trailling edge with control input (Wa)** The supply voltage U must be constantly applied to the device (green LED U/t illuminated). Closing the control contact S has no influence on the condition of the output R. When the control contact is opened, the output relay switches into on-position (yellow LED illuminated) and the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated), the ouput relay switches into off-position (yellow LED not illuminated). During the interval, the control contact can be operated any number of times. A further cycle can only be started when the cycle run has been completed. **==> picture [170 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>S<br>R t t<br>**----- End of picture text -----**<br> **www.tele-online.com** **E3ZM20** ## **Connections** ## **Dimensions** **==> picture [503 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> with control contact without control contact<br>(+) (+)<br>U [~] U [~]<br>(-) (-)<br>15 25 S 15 25<br>A1 B1 A1 B1<br>A1 15 25 A1 15 25<br>R R R R<br>A2 16 18 [26] [28] A2 16 18 [26] [28]<br>A2 A2<br>16 18 26 28 16 18 26 28<br>5mm 44mm<br>35mm<br>60mm<br>45mm 87mm<br>**----- End of picture text -----**<br> ## **Ordering Informations** |**Types**||**Functiones**|**Supply Voltage**|**Part. No.**| |---|---|---|---|---| |E3ZM20|12-240V AC/DC|E, R, Ws, Wa, Es, Wu, Bp|12-240V AC/DC|111100| **==> picture [188 x 44] intentionally omitted <==** RELEASE 2009/07 Subject to alterations and errors **www.tele-online.com**
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →