E1ZM10 12-240VAC/DC
Analogue Timer, ENYA, Multifunction, 1 s, 100 h, 7 Ranges, 1 Changeover Relay
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TELE
- Product type: Analogue Timers - DIN Rail
- Time Max: 100h
- Time Min: 1s
- Timer Output: 1 Changeover Relay
- Product Range: ENYA
- Timer Functions: Multifunction
- Current Rating Nom: 8A
- Supply Voltage Max: 240V
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 64.25 € |
| Current stock | 200+ |
| Lead time | 7 days |
**E1ZM, E1Z1** ## **Timers** ENYA series Multifunction Up to 7 functions 7 time ranges Wide input voltage range 1 change over contact Width 17.5 mm Installation design ## **Technical data** ## **1. Functions** The function has to be set before connecting the relay to the supply voltage. E ON delay R OFF delay Ws Single shot leading edge with control input Wa Single shot trailing edge with control input Es ON delay with control input Wu Single shot leading edge voltage controlled Bp Flasher pause first Function sets of the distinct types are according to table ordering information or printing on the unit. ## **2. Time ranges** |**2. Time ranges**||| |---|---|---| |Time range|Adjustment range|Adjustment range| |1s|50ms|1s| |10s|500ms|10s| |1min|3s|1min| |10min|30s|10min| |1h|3min|1h| |10h|30min|10h| |100h|5h|100h| ## **3. Indicators** Green LED U/t ON: indication of supply voltage Green LED U/t flashes: indication of time period Yellow LED R ON/OFF: indication of relay output ## **4. Mechanical design** Self-extinguishing plastic housing, IP rating IP40 Mounted on DIN-rail TS 35 according to EN 60715 Mounting position: any Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 Tightening torque: max. 1Nm Terminal capacity: 1 x 0.5 to 2.5mm² with/without multicore cable end 1 x 4mm² without multicore cable end 2 x 0.5 to 1.5mm² with/without multicore cable end 2 x 2.5mm² flexible without multicore cable end ## **5. Input circuit** Supply voltage: terminals A1(+)-A2 E1Z... 12-240VAC/DC: 12 to 240V a.c./d.c. Tolerance: 12V -10% to 240V +10% E1Z... 24-240VAC/DC: 24 to 240V a.c./d.c. Tolerance: 24V -15% to 240V +10% Rated consumption: 4VA (1.5W) Rated frequency: a.c. 48 to 63Hz Duty cycle: 100% Reset time: 100ms Residual ripple for d.c.: 10% Drop-out voltage: >30% of minimum rated supply voltage Overvoltage category: III (in accordance with IEC 60664-1) Rated surge voltage: 4kV ## **6. Output circuit** 1 potential free change over contact Contact material: AgNi Rated voltage: 250V a.c. Switching capacity: 2000VA (8A / 250V a.c.) Fusing: 8A fast acting Mechanical life: 20 x 10[6] operations Electrical life: 2 x 10[5] operations at 1000VA resistive load Switching frequency: max. 6/min at 1000VA resistive load (in accordance with IEC 60947-5-1) Overvoltage category: III (in accordance with IEC 60664-1) Rated surge voltage: 4kV ## **7. Control input** Input not potential free: terminals A1-B1 Loadable: yes Max. line length: 10m Trigger level (sensitivity): automatic adaption to supply voltage Min. control pulse length: d.c. 50ms / a.c. 100ms ## **8. General data** Degree of protection: Basic insulation Insulation test voltage: Supply circuit - Output circuit: 1680V Interference immunity: Class A Prospective current value: 1000A / 8A ## **8. Accuracy** ±1% of maximum scale value <5% of maximum scale value <0.5% or ±5ms Base accuracy: Adjustment accuracy: Repetition accuracy: Voltage influence: Temperature influence: - ≤0.01% / °C ## **9. Ambient conditions** -25 to +55°C Ambient temperature: Storage temperature: Transport temperature: Relative humidity: -25 to +70°C -25 to +70°C 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) Pollution degree: 2 (in accordance with IEC 60664-1) ## **10. Weight** Single packing: Package 10pcs: 72g 670g per Package **www.tele-online.com** **E1ZM, E1Z1** ## **Functions** ## **ON delay (E)** When the supply voltage U is applied, the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay R switches into on-position (yellow LED illuminated). This status remains until the supply voltage is interrupted. If the supply voltage is interrupted before the expiry of the interval t, the interval already expired is erased and is restarted when the supply voltage is next applied. **==> picture [196 x 48] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>R t <t<br>**----- End of picture text -----**<br> ## **OFF delay (R)** The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the output relay R switches into on-position (yellow LED illuminated). If the control contact is opened, the set interval t begins (green LED flashes). After the interval t has expired (green LED U/t illuminated) the output relay switches into off-position (yellow LED not illuminated). If the control contact is closed again before the interval t has expired, the interval already expired is erased and is restarted. **==> picture [201 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>S <t<br>R t <t<br>**----- End of picture text -----**<br> ## **Single shot leading edge with control input (Ws)** The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the output relay R switches into on-position (green LED U/t illuminated) and the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay switches into off-position (yellow LED not illuminated). During the interval, the control contact can be operated any number of times. A further cycle can only be started when the cycle run has been completed. **==> picture [201 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>S<br>R t t<br>**----- End of picture text -----**<br> ## **ON delay with control input (Es)** The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay R switches into on-position (yellow LED illuminated). This status remains until the control contact is opened again. If the control contact is opened before the interval t has expired , the interval already expired is erased and is restarted with the next cycle. **==> picture [201 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>S<br>R t1 <t<br>**----- End of picture text -----**<br> ## **Single shot leading edge voltage controlled (Wu)** When the supply voltage U is applied, the output relay R switches into on-position (yellow LED illuminated) and the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay switches into off-position (yellow LED not illuminated). This status remains until the supply voltage is interrupted. If the supply voltage is interrupted before the interval t has expired, the output relay switches into off-position. The interval already is erased and is restarted when the supply voltage is next applied. **==> picture [196 x 47] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>R t <t<br>**----- End of picture text -----**<br> ## **Flasher pause first (Bp)** When the supply voltage U is applied, the set interval t begins (green LED U/t flashes). After the interval t has expired, the output relay R switches into on-position (yellow LED illuminated) and the set interval t begins again. After the interval t has expired, the output relay switches into off-position (yellow LED not illuminated). The output relay is triggered at a ratio of 1:1 until the supply voltage is interrupted. **==> picture [196 x 48] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>R t t t t<br>**----- End of picture text -----**<br> ## **Single shot trailling edge with control input (Wa)** The supply voltage U must be constantly applied to the device (green LED U/t illuminated). Closing the control contact S has no influence on the condition of the output R. When the control contact is opened, the output relay switches into on-position (yellow LED illuminated) and the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated), the ouput relay switches into off-position (yellow LED not illuminated). During the interval, the control contact can be operated any number of times. A further cycle can only be started when the cycle run has been completed. **==> picture [201 x 69] intentionally omitted <==** **----- Start of picture text -----**<br> U<br>LED U/t<br>S<br>R t t<br>**----- End of picture text -----**<br> **www.tele-online.com** **E1ZM, E1Z1** ## **Connections** ## **Dimensions** **==> picture [499 x 182] intentionally omitted <==** **----- Start of picture text -----**<br> with control input without control input<br>(+) (+)<br>U [~] U [~]<br>(-) (-)<br>15 S 15<br>A1 B1 A1 B1<br>A1 15 A1 15<br>R R<br>A2 16 18 A2 16 18<br>Fo IEE |] al<br>5mm 44mm<br>17,5mm<br>A2 A2 60mm<br>16 18 16 18<br>FE } |EB ——<br>87mm<br>45mm<br>**----- End of picture text -----**<br> ## **Ordering information** |**Type**|**Functions**|**Supply voltage**|**Art. No. (PQ 1)**|**Art. No. (PQ 10)**| |---|---|---|---|---| |E1ZM10 12-240V AC/DC|E, R,Ws, Wa, Es, Wu, Bp|12-240V a.c./d.c.|110100|110100A| |E1ZM10 24-240V AC/DC|E, R,Ws, Wa, Es, Wu, Bp|24-240V a.c./d.c.|110200|110200A| |E1ZMQ10 24-240V AC/DC|E, R, Wu, Bp|24-240V a.c./d.c.|110202|110202A| |E1Z1E10 24-240V AC/DC|E|24-240V a.c./d.c.||110204A| |E1Z1R10 24-240V AC/DC|R|24-240V a.c./d.c.||110205A| **TELE Haase Steuergeräte Ges.m.b.H.** Vorarlberger Allee 38 AT-1230 Vienna, AUSTRIA RELEASE 2017/01 Subject to alterations and errors **www.tele-online.com**
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →