CUS60M24
POWER SUPPLY, MEDICAL, AC-DC, 24V 2.5A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Open Frame Power Supplies
- Power Supply Applications:Medical; No. of Outputs:1 Output; Power Rating (Forced Cooling):-; Power Rating (Convection Cooling):60W; Input Voltage VAC:85V AC to 33AC6176
- Product Range: CUS60M Series
- No. of Outputs: 1 Output
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 60W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 35.98 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TDK-Lambda** ## **CUS60M** ## SPECIFICATIONS |**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS|**TDK-Lambda**<br>**CUS60M**<br>SPECIFICATIONS| |---|---|---|---|---|---|---|---|---|---|---|---|---| |CA849-01-01C||||||||||||| |MODEL<br>ITEMS|||CUS60M<br>-5|CUS60M<br>-12|CUS60M<br>-15|CUS60M<br>-18||||CUS60M<br>-24||CUS60M<br>-48| |1|NominalOutput Voltage|V|5|12|15|18||||24||48| |2|Maximum Output Current|A|6|5.0|4.0|3.35||||2.5||1.25| |3|Maximum Output Power|W|30.0|60.0|60.0|60.3||||60||60| |4|Efficiency (Typ.)<br>115/230 VAC(*1)|%|81 / 81|87 / 88|87.5 / 87|88 / 88||||89 / 90||90 / 91| |5|Active Average Efficiencyrelated to Erp 115/230 VAC(*1)|-|81 / 79.5|87 / 86|87 / 86.5|87 / 87||||88 / 87||90 / 89| |6|NoLoadPowerConsumption|W|< 0.5@265VAC,Ta=25°C,Nominal Output Voltage|||||||||| |7|Input VoltageRange<br>(*2)|-|85 - 265 VAC(47-63Hz)|||||||||| |8|Input Current (Typ.)<br>115/230 VAC(*1)|A|0.7/ 0.5|1.2 / 0.8||||||||| |9|InrushCurrent (Typ.)<br>(*1)(*3)|A|30 / 60 at Cold Start|||||||||| |10|Output Voltage|-|Fixed<br>Shipment condition: 5V: ±3%;12V,15V,18V,24V,48V: ±2.5%|||||||||| |11|Maximum Ripple & Noise(Ta>0oC/Ta<=0oC)(*1)(*4)(*5)|mV|120 / 200|120 / 200|150 / 500|150 / 500||||150 / 500||200 / 500| |12|<br> Maximum Ripple & Noise (0%~35%Load) (*4)(*5)|mV|240|280|280|280||||280||480| |13|Maximum LineRegulation<br>(*4)(*6)|mV|20|48|60|72||||96||192| |14|Maximum LoadRegulation<br>(*4)(*7)|mV|100|120|120|144||||192||384| |15|Temperature Coefficient<br>(*4)|-|Less than 0.02% / °C|||||||||| |16|OverCurrentProtection<br>(*8)|-|>105% of Maximum Output Current . 12V,15V,18V,24V Class 2 limitedpower source|||||||||| |17|Over Voltage Protection<br>(*9)|-|Above 120% ~,shutdown|||||||||| |18|Hold-up time (Typ.)<br>115/230 VAC(*1)|ms|20 / 100|||||||||| |19|Earth Leakage Current<br>(*10)|-|0.2mA max@265VAC,60Hz|||||||||| |20|PatientLeakage Current|-|60uA max@265VAC,60Hz,Input to Output|||||||||| |21|ParallelOperation|-|No|||||||||| |22|Series Operation|-|Possible|||||||||| |23|OperatingTemperature<br>(*11)|-|-20°C ~ +70°C|||||||||| |24|OperatingHumidity|-|10 - 90%RH(No condensing)|||||||||| |25|StorageTemperature|-|-40°C ~ +85°C|||||||||| |26|StorageHumidity|-|10 - 90%RH(No condensing)|||||||||| |27|OperatingAltitude|-|5000m,derating5°C/1000m above 3000m|||||||||| |28|IsolationClass / Class of Protection|-|Class I(L,N,FG)or ClassII(L,N)|||||||||| |29|Cooling|-|Convection Cooling|||||||||| |30|Withstand Voltage|-|Output-FG : 1.5kVAC(20mA)1xMOPP<br>Input-FG : 2kVAC (20mA) 1xMOPP,<br>Input-Output : 4kVAC (20mA) 2xMOPP,|||||||||| |31|Isolation Resistance|-|More than 100MΩ at 25°C,70%RH,Output - FG : 500VDC|||||||||| |32|Vibration|-|At no operating, 10-500Hz (Sweep for 1min.)<br>Maximum 19.6m/s2 X,Y,Z 1 hour each|||||||||| |33|Shock|-|Less than 196m/s2|||||||||| |34|Safety|-|Approved by IEC/EN62368-1, UL62368-1, CSA62368-1<br>Approved by IEC/EN60601-1, ES60601-1, CSA-C22.2 No.60601-1|||||||||| |35|Pollution|-|Degree 2,materialgroup3|||||||||| |36|EMI<br>(*1)|-|Designed to meet EN55011-B,EN55032-B,FCC-Class B|||||||||| |37|Immunity|-|Designed to meet IEC61000-4-2 (Level 4,3), IEC61000-4-3 (Level 3),<br>IEC61000-4-4 (Level 3), IEC61000-4-5 (Level 3,4),IEC61000-4-6 (Level 3),<br>IEC61000-4-8 (Level 4) , IEC60601-1-2 Ed.4.1 , Criteria A|||||||||| |38|Line voltage dip|-|<br>SEMI47(Input Voltage: 200VAC ~ 240VAC)|||||||||| |||-|Designed to meet IEC61000-4-11(Class 3):<br>Criteria A: 200VAC~240VAC<br>Criteria B: 100VAC~120VAC|||||||||| |||-|Criteria B:Input Voltage below 120VAC and Output Current more than 70%<br>Designed to meet IEC61000-4-11 (Class 2) : IEC60601-1-2 Ed.4.1<br>Criteria A:Input Voltage above 120VAC or output below 70% of Maximum Output Current|||||||||| |39|Weight(Typ.)|g|120|||||||||| |40|Size(L x W x H)|inch|3 x 2 x 1.05(Refer to Outline Drawing)|||||||||| |***Read instruction manual carefully, before using the power supply unit.**<br>=NOTES=<br>*1. At 115VAC/230VAC, Ta=25°C, nominal output voltage and maximum output power.<br>*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,<br>input voltage range will be 100 ~ 240VAC (50-60Hz).<br>*3. Not applicable for the in-rush current to noise filter for less than 0.2ms.<br>terminated with a 0.1uF and 47uF capacitor.<br>*6. 85~265VAC, constant load.<br>*7. No load - full load, constant input voltage.<br>*5. Ripple & noise are measured at 20MHz by using a 150mm twisted pair of load wires<br>*4. Please refer to Fig. A for measurement of Vo, line and load regulation and ripple voltage.<br>Output derating required when Vin is less than 100VAC, refer output derating curve for details.<br>*8. Hiccup with automatic recovery. Avoid operating at over load or short circuit condition.<br> <br>Output Terminal<br>Measurement point for Vo Line/Loa<br>Measuremen<br>**47**μ<br>150mm<br>-V<br>+V|||||||||150mm||d Regulation<br>t point for Ripple and Noise<br>0.1μ<br>Fig.A<br>A|| ||||||||||Measuremen<br>**47**μ<br>-V<br>+V||t point for Ripple and Noi<br>0.1μ<br>Fig.A<br>A|| ||||||||Output Terminal|||||| |||||||||||||| - *9. OVP circuit shut down the output, manual reset (Re power on) to get output voltage. - *10. Measured by the each measuring method of UL, CSA, and EN (at 60Hz), Ta=25°C. - *11. Refer to output derating curve for details of output derating versus input voltage, ambient temperature and mounting method . - Load (%) is percent of maximum output power or maximum output current. Do not exceed its derating of maximum Load. - Maximum load start up at -30°C is possible. However, it may not fulfill all the specifications. **TDK-Lambda** **CUS60M** ## OUTPUT DERATING CA849-01-02A **==> picture [429 x 520] intentionally omitted <==** **----- Start of picture text -----**<br> OUTPUT DERATING VERSUS OPERATING AMBIENT TEMPERATURE (Ta)<br>* COOLING: CONVECTION COOLING<br>1. CUS60M-5,18,48<br>LOAD(%)<br>Ta(°C)<br>Mounting A,B,C,D,E<br>-20~50 100%<br>70 50%<br>120<br>100 MOUNTING A,B,C,D,E<br>80<br>60<br>40<br>20<br>0<br>-20 -10 0 10 20 30 40 50 60 70 80<br>Ta (°C)<br>2. CUS60M-12<br>LOAD(%) LOAD(%)<br>Ta(°C) Ta(°C)<br>MOUNTING A,B,C,D MOUNTING E<br>-20~45 100% -20~45 100%<br>70 50% 70 40%<br>120<br>MOUNTING A,B,C,D<br>100<br>MOUNTING E<br>80<br>60<br>40<br>20<br>0<br>-20 -10 0 10 20 30 40 50 60 70 80<br>Ta (°C)<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> **TDK-Lambda** **CUS60M** OUTPUT DERATING CA849-01-03 ## **OUTPUT DERATING VERSUS OPERATING AMBIENT TEMPERATURE (Ta)** * COOLING: CONVECTION COOLING **==> picture [412 x 506] intentionally omitted <==** **----- Start of picture text -----**<br> 3. CUS60M-15<br>LOAD(%) LOAD(%)<br>Ta(°C) Ta(°C)<br>MOUNTING A,C,D MOUNTING B,E<br>-20~40 100% -20~40 100%<br>70 50% 55 75%<br>66 50%<br>70 25%<br>120<br>MOUNTING A,C,D<br>100<br>MOUNTING B,E<br>80<br>60<br>40<br>20<br>0<br>-20 -10 0 10 20 30 40 50 60 70 80<br>Ta (°C)<br>4. CUS60M-24<br>LOAD(%) LOAD(%)<br>Ta(°C) Ta(°C)<br>MOUNTING A,B,C,D MOUNTING E<br>-20~50 100% -20~46 100%<br>70 50% 70 40%<br>120<br>MOUNTING A,B,C,D<br>100<br>MOUNTING E<br>80<br>60<br>40<br>20<br>0<br>-20 -10 0 10 20 30 40 50 60 70 80<br>Ta (°C)<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> **TDK-Lambda** **CUS60M** ## OUTPUT DERATING CA849-01-04 ## **OUTPUT DERATING VERSUS INPUT VOLTAGE** * COOLING: CONVECTION COOLING **==> picture [400 x 321] intentionally omitted <==** **----- Start of picture text -----**<br> CUS60M-5,24 CUS60M-12,18,48<br>Mounting A,B,C,D,E Mounting A,B,C,D,E<br>INPUT VOLTAGE INPUT VOLTAGE<br>LOAD (%) LOAD (%)<br>(VAC) (VAC)<br>85~265 100 85 80<br>100~265 100<br>pf} |__| _<br>CUS60M-15<br>Mounting A,B,C,D,E<br>INPUT VOLTAGE<br>LOAD (%)<br>(VAC)<br>85 60<br>100~265 100<br>—4<br>120<br>CUS60M-12,18,48<br>100 CUS60M-5,24<br>CUS60M-15<br>80<br>60<br>40<br>20<br>0<br>85 115 145 175 205 235 265<br>Vin (VAC)<br>LOAD (%)<br>**----- End of picture text -----**<br> ## **MOUNTING METHOD** MOUNTING A MOUNTING B MOUNTING C MOUNTING D MOUNTING E (STANDARD MOUNTING) CN1 CN1 CN1(INPUT) ~~ap~~ CN1 a ~~dig~~ CN1
Updated at April 27, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →