CUB7CVS0
MULTIFUNCTION COUNTER
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: RED LION CONTROLS
- Product type: Counters
- Digit Height: 8.9mm
- Panel Cutout Width: 44.96mm
- Supply Voltage Max: 250V
- Supply Voltage Min: 50V
- Panel Cutout Height: 22.1mm
- No. of Digits / Alpha: 8
- Operating Temperature Max: 50°C
- Operating Temperature Min: 0°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 91.24 € |
| Current stock | 10+ |
| Lead time | 13 days |
Bulletin No. CUB7N-D Drawing No. LP0825 Released 09/12 ## Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 red lpn Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net ## _**MODEL CUB7 – MINIATURE ELECTRONIC 8 DIGIT COUNTER or TIMER**_ - l 0.35" (8.9 mm) _HIGH LCD DIGITS, REFLECTIVE OR TRANSMISSIVE WITH YELLOW/GREEN OR RED BACKLIGHTING (6-26 VDC power supply required for version with LED backlighting)_ - l _INTERNAL LITHIUM BATTERY PROVIDES UP TO 7 YEARS OF TYPICAL UNINTERRUPTED OPERATION_ - l _COUNT SPEEDS UP TO 10KHZ_ - l _9 PROGRAMMABLE TIME RANGES_ - l _CONTACT, LOGIC, OPEN COLLECTOR, OR HIGH VOLTAGE INPUTS_ - l _STANDARD WIRE CONNECTIONS OR OPTIONAL PLUG-IN TERMINAL BLOCK_ **==> picture [105 x 35] intentionally omitted <==** **----- Start of picture text -----**<br> C ULR US LISTED<br>3RSD<br>PROCESS CONTROL EQUIPMENT<br>**----- End of picture text -----**<br> - l _NEMA 4X/IP65 SEALED FRONT BEZEL THAT FITS 1/32 DIN CUT-OUT_ ## **DESCRIPTION** The CUB7 series is an 8-digit lithium battery powered miniature counter or timer with large 0.35" (8.9 mm) high digits. It has an LCD read-out available in Positive Imagine Reflective, Negative Image Transmissive with yellow/green or red backlighting. The backlight versions require an external 6-26 VDC power supply. The CUB7 series is housed in a lightweight, high impact plastic case with a clear viewing window. The sealed front panel with silicon rubber keypad meets NEMA 4X/IP65 specification for wash-down and/or dusty environments, when properly installed with supplied panel gasket and mounting clip. Both counter and timer CUB7 models are available with a low voltage input (28 VDC max) or an isolated high voltage input (50-250 VDC/VAC). The low voltage input has DIP switch selections for SINKING or SOURCING along with a HIGH/LOW FREQUENCY selection (low frequency for contact inputs). Both units have front panel keypads that can be used to reset the display. The keypad can be enabled/disabled via a single DIP switch. The standard unit uses 22 gauge wires for external connections, an optional plug-in terminal block is available. ## **SAFETY SUMMARY** All safety related regulations, local codes and instructions that appear in the literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. ## **SPECIFICATIONS** 1. **DISPLAY** : 8-digit LCD, 0.35" (8.90 mm) high digits 2. **POWER** : Non-replaceable internal 3.6 VDC lithium battery provides 7 years of typical continuous operation (high count speeds in SNK mode & extreme ambient temperatures will decrease battery life, use of SRC mode can extend battery life) - **OPTIONAL LED BACKLIGHT POWER** : 6-26 VDC @ 25 mA max. Must use an NEC Class 2 or Limited Power Source (LPS) rated power supply. Note: External power shall incorporate disconnecting device (switch or circuit breaker) and provide Double/Reinforced isolation from MAINS supply. 3. **LOW VOLTAGE INPUT** : COUNTERS: CUB7CCS0, CUB7CCR0, CUB7CCG0 - SNK mode (DIP switch 1 off, internal pull-up to battery) - VIN High Min = 1.25 VDC; VIN Low Max = 0.45 VDC IIN Max = 8 µA; VIN Max = 3.6 VDC - Count Speed: (count on negative edge) - High freq mode (DIP switch 2 off): max 5 kHz @ 50% duty cycle Low freq mode (DIP switch 2 on): max 30 Hz @ 50% duty cycle - Note: The three models listed above may be used for count inputs with 10-50 VAC signals when using a VCM10000 converter module. DIP switches must be set for SNK and Low frequency. - SRC mode (DIP switch 1 on, internal 20 k W pull-down to common) - VIN High Min = 1.25 VDC; VIN Low Max = 0.45 VDC - IIN Max = 5 mA; VIN Max = 28 VDC - Count Speed: (count on negative edge) High freq mode (DIP switch 2 off): max 10 kHz @ 50% duty cycle Low freq mode (DIP switch 2 on): max 50 Hz @ 50% duty cycle TIMERS: **CAUTION: Risk of Danger.** Read complete instructions prior to installation and operation of the unit. **CAUTION:** Risk of electric shock. Models: CUB7TCS0, CUB7TCR0, CUB7TCG0 **For these models, the unit will time when the CUB7 input is low.** SNK mode (DIP switch 1 off, internal pull-up to battery) - VIN High Min = 1.25 VDC; VIN Low Max = 0.45 VDC IIN Max = 8 µA; VIN Max = 3.6 VDC Note: The three models listed above may be used with 10-50 VAC ## **DIMENSIONS In inches (mm)** Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.1" (53.4) H x 5.5" (140) W. **==> picture [470 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> 1.10 0.87<br>(27.9) (22.1)<br>He 2.00 (50.8) Fie 1.64 (41.6) st 2.17 (55)<br>With Wires With Terminal Block<br>**----- End of picture text -----**<br> **==> picture [53 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> With Wires<br>**----- End of picture text -----**<br> _1_ signals when using a VCM10000 converter module. SRC mode (DIP switch 1 on, internal 20 k W pull-down to common) VIN High Min = 1.25 VDC; VIN Low Max = 0.45 VDC IIN Max = 5 mA; VIN Max = 28 VDC Models: CUB7TCS1, CUB7TCR1, CUB7TCG1 **For these models, the** ## **unit will time when the CUB7 input is high.** SNK mode (DIP switch 1 off - **DO NOT USE** ) SRC mode (DIP switch 1 on, internal 20 k W pull-down to common) VIN High Min = 1.25 VDC; VIN Low Max = 0.45 VDC IIN Max = 5 mA; VIN Max = 28 VDC 4. **HIGH VOLTAGE INPUT** : COUNTERS: CUB7CVS0, CUB7CVR0, and CUB7CVG0 The unit adds one count with voltage present VIN Range = 50-250 VDC/VAC 50/60 Hz, 5 mA max Isolation: 2500 VAC 1 min TIMERS: CUB7TVS0, CUB7TVR0, and CUB7TVG0 Unit will time with voltage present VIN Range = 50-250 VDC/VAC 50/60 Hz, 5 mA max Isolation: 2500 VAC 1 min ## 5. **RESET INPUT** : VIN Low Max = 1.5 VDC (internal pull-up to battery) IIN Max = 20 µA - 5 msec min (active low) Note: Reset input is active low to clear display to zero ## 6. **TIMER ACCURACY** : CUB7TV: 0.03% +100 msec per RUN terminal activation CUB7TC low freq/snk setup: 0.03% +1 msec per RUN terminal activation CUB7TC high freq/snk setup: 0.03% -1 msec per RUN terminal activation 7. **ENVIRONMENTAL CONDITIONS** : Operating Temperature: 0 to 50 °C Storage Temperature: -30 to 80 °C Vibration according to IEC 68-2-6: Operational 5 to 500 Hz, in X, Y, Z direction for 1.5 hours, 5 g. Shock according to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions. Operating and Storage Humidity: 85% max. (non-condensing) 8. **CONNECTIONS** : 22 gauge wire; wire length minimum 10" **OPTIONAL TERMINAL BLOCKS** : Wire clamping terminals Wire Strip Length: 0.275" (7 mm) Wire Gage: 24-16 AWG copper wire 9. **CONSTRUCTION** : High impact plastic case with clear viewing window. The front panel meets NEMA 4X/IP65 requirements for outdoor use when properly installed. Installation Category II, Pollution Degree 2. Panel gasket and mounting clip are included. ## 10. **CERTIFICATIONS AND COMPLIANCES** : **SAFETY** UL Listed, File # E179259, UL508 Type 4X Outdoor Enclosure rating (Face only), UL50 IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1. IP65 Enclosure rating (Face only), IEC 529 ## **ELECTROMAGNETIC COMPATIBILITY** Emissions and Immunity to EN 61326:2006: Electrical Equipment for Measurement, Control and Laboratory use. ## **Immunity to Industrial Locations:** |Electrostatic discharge|EN 61000-4-2|Criterion A| |---|---|---| |||4 kV contact discharge| |||8 kV air discharge| |Electromagnetic RF fields|EN 61000-4-3|Criterion A| |||10 V/m (80 MHz to 1 GHz)| |||3 V/m (1.4 GHz to 2 GHz)| |||1 V/m (2 GHz to 2.7 GHz)| |Fast transients (burst)|EN 61000-4-4|Criterion A| |||2 kV power| |||1 kV I/O signal| |Surge|EN 61000-4-5|Criterion A| |||power 1 kV L to L,| |||2 kV L to G| |RF conducted interference|EN 61000-4-6|Criterion A| |||3 Vrms| |Power freq magnetic fields|EN 61000-4-8|Criterion A| |||30 A/m| |AC power|EN 61000-4-11|| |Voltage dip||Criterion A| |||0% during 1 cycle| |||40% during 10/12 cycle| |||70% during 25/30 cycle| |Short interruptions||Criterion B| |||0% during 250/300 cycles| |**Emissions:**||| |Emissions|EN 55011|Class B| Notes: 1. Criterion A: Normal operation within specified limits. 2. Criterion B: Temporary loss of performance from which the unit selfrecovers. - Refer to the EMC Installation Guidelines section of the bulletin for additional information. 11. **WEIGHT** : 0.11 lbs. (0.05 Kg) ## **Ordering infOrmatiOn** **==> picture [532 x 123] intentionally omitted <==** **----- Start of picture text -----**<br> COUNTERS TIMERS<br>CUB7 C 0 CUB7 T 0<br>0 - USE WITH LOW VOLTAGE TO<br>C - LOW VOLTAGE C - LOW VOLTAGE TIME WHEN INPUT IS LOW<br> +28 VDC max +28 VDC max USE WITH HIGH VOLTAGE TO<br>V - HIGH VOLTAGE V - HIGH VOLTAGE TIME WHEN INPUT IS HIGH<br> 50-250 VAC/DC 50-250 VAC/DC 1 - VALID ONLY WITH LOW VOLTAGE (C)<br>S - REFLECTIVE S - REFLECTIVE USE WITH 28 VDC (SRC MODE) TO<br>R - RED R - RED TIME WHEN INPUT IS HIGH<br>G - GREEN G - GREEN<br>**----- End of picture text -----**<br> ## **Accessories Part Numbers** |**TYPE**|**DESCRIPTION**|**PART NUMBER**|**USED WITH**| |---|---|---|---| |Plug-in<br>Terminal Block|3 Position Terminal Block|TB100003|CUB7CCS0, CUB7TCS0, CUB7TCS1| ||4 Position Terminal Block|TB100004|CUB7CCG0, CUB7TCG0, CUB7TCG1,<br>CUB7CCR0, CUB7TCR0, CUB7TCR1,<br>CUB7CVS0, CUB7TVS0| ||5 Position Terminal Block|TB100005|CUB7CVG0, CUB7TVG0, CUB7CVR0,<br>CUB7TVR0| |Enclosure *|CUB7 Enclosure|ENC13000|| |Base Mount *|CUB7 Base Mount|BMK80000|| |_See Wiring the Meter section to determine the terminal block needed._<br>_* Enclosure and base mount will NOT function with plug-in terminal block option._|||| _2_ ## **1.0 installing the meter** ## **INSTALLATION ENVIRONMENT** The unit should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation. Placing the unit near devices that generate excessive heat should be avoided. The bezel should be cleaned only with a soft cloth and neutral soap product. Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the aging process of the bezel. Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the keypad of the unit. ## **Installation** The CUB7 series of products meets NEMA 4X/IP65 requirements for outdoor use, when properly installed. The units are intended to be mounted into an enclosed panel. The viewing window and reset button are factory sealed for a washdown environment. A sponge rubber gasket and mounting clip are provided for installing the unit in the panel cut-out. **==> picture [162 x 80] intentionally omitted <==** **----- Start of picture text -----**<br> 1.77 +0.024<br>-0.000<br>(45 )+0.6-0.0<br>0.88 +0.012-0.000<br>(22.2 )+0.3-0.0<br>**----- End of picture text -----**<br> The following procedure assures proper installation: 1. Cut panel opening to specified dimensions. Remove burrs and clean around panel opening. 2. Carefully remove and discard the center section of the gasket. Slide the panel gasket over the rear of the unit to the back of the bezel. Insert the mounting screws onto both sides of mounting clip. The tip of the screw should **NOT** project from the hole in the mounting clip. 3. Install the CUB7 unit through the panel cut-out until the front bezel flange contacts the panel. 5. Alternately tighten each screw to ensure uniform gasket pressure. Visually inspect the front panel gasket. The gasket should be compressed to about 75 to 80% of its original thickness. If not, gradually turn mounting screws to further compress gasket. 6. If gasket is not adequately compressed and the mounting screws can no longer be turned, loosen mounting screws, and check that mounting clip is latched as close as possible to the panel. 7. Repeat from step #5 for tightening mounting screws. 4. Slide the mounting clip over the rear of the unit until the clip is against the back of the panel. The mounting clip has latching features which engage into mating features on the CUB7 housing. _Note: It is necessary to hold the unit in place when sliding mounting clip into position._ **==> picture [369 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> Latching Feature<br>Bezel<br>Gasket<br>Mounting<br>Clip<br>Mounting<br>Screw<br>**----- End of picture text -----**<br> _3_ ## **2.0 setting the dip switches** **==> picture [200 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> Rear of Unit<br>ON<br>Bottom of Unit<br>1 2 3<br>SRC LO FREQ KEY EN<br>SNK HI FREQ KEY DIS<br>**----- End of picture text -----**<br> ## **Low Voltage Input Unit** **==> picture [188 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> Rear of Unit<br>ON<br>Bottom of Unit<br>1<br>KEY EN<br>KEY DIS<br>**----- End of picture text -----**<br> ## **High Voltage Input Unit** Low voltage input units have 3 DIP switches that must be positioned appropriately prior to wiring. High voltage input units have 1 DIP switch to enable or disable the front bezel keypad. _Note: Placing the KEY DISABLE/ENABLE DIP switch in the OFF position, disables all front panel keys._ ## **3.0 prOgramming the time range** The CUB7 Timer has 9 time ranges. To change ranges, enable the front keypad with the DIP switch and press the SEL key. The currently programmed time range will be displayed (example 2222222.2 = time range 2). To change the range, press the RST key. The ranges will cycle from 0-8 and back to 0. To enter your time range, press the SEL key and the unit will retain the current time range and return back to normal. **==> picture [144 x 81] intentionally omitted <==** **----- Start of picture text -----**<br> 85374216<br>**----- End of picture text -----**<br> |**DISPLAY DURING**<br>**PROGRAMMING**|**TIMER RANGE**| |---|---| |00000.000|0.001 SEC| |111111.11|0.01 SEC| |2222222.2|0.1 SEC| |333333333|1 SEC| |4444444.4|0.1 MIN| |555555555|1 MIN| |666666.66|0.01 HR| |7777777.7|0.1 HR| |88888888|1 HR| **==> picture [197 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> SEL RST<br>**----- End of picture text -----**<br> ## **4.0 resetting the display** The display may be reset to zero via the front RST key, the remote reset input or both. The front RST key must be enabled for front panel reset. DIP switch # 3 on the low voltage input units or the single DIP switch on the high voltage input units. (See 2.0 Setting the DIP Switches for switch location) The remote reset is activated via an external momentary contact closure between the reset input (blue wire) and the common (black wire). When the optional terminal blocks are used, see 5.0 Wiring The Meter, for the appropriate reset input terminal and the common terminal. _4_ ## **5.0 wiring the meter** ## **WIRING OVERVIEW** Electrical connections are made to the #22 AWG colored wires protruding from the rear of the unit. When using the optional terminal block, the #22 AWG colored wires are cut off and electrical connections are made via screwless type terminal block. All conductors should conform to the meter’s voltage and current ratings. All cabling and wire terminations should conform to appropriate standards of good installation, local codes and regulations. It is recommended that the backlight power supplied to the meter (DC or AC) be protected by a fuse or circuit breaker. ## **EMC INSTALLATION GUIDELINES** Although this meter is designed with a high degree of immunity to ElectroMagnetic Interference (EMI), proper installation and wiring methods must be followed to ensure compatibility in each application. The type of the electrical noise, source or coupling method into the meter may be different for various installations. The meter becomes more immune to EMI with fewer I/O connections. Cable length, routing, and shield termination are very important and can mean the difference between a successful or troublesome installation. Listed below are some EMC guidelines for successful installation in an industrial environment. 1. The meter should be mounted in a metal enclosure, which is properly connected to protective earth. 2. Use shielded (screened) cables for all Signal and Control inputs. The shield (screen) pigtail connection should be made as short as possible. The connection point for the shield depends somewhat upon the application. Listed below are the recommended methods of connecting the shield, in order of their effectiveness. - a. Connect the shield only at the panel where the unit is mounted to earth ground (protective earth). - b. Connect the shield to earth ground at both ends of the cable, usually when the noise source frequency is above 1 MHz. - c. Connect the shield to common of the meter and leave the other end of the shield unconnected and insulated from earth ground. 3. Never run Signal or Control cables in the same conduit or raceway with AC power lines, conductors feeding motors, solenoids, SCR controls, and heaters, etc. The cables should be ran in metal conduit that is properly grounded. This is especially useful in applications where cable runs are long and portable two-way radios are used in close proximity or if the installation is near a commercial radio transmitter. 4. Signal or Control cables within an enclosure should be routed as far as possible from contactors, control relays, transformers, and other noisy components. 5. In extremely high EMI environments, the use of external EMI suppression devices, such as ferrite suppression cores, is effective. Install them on Signal and Control cables as close to the unit as possible. Loop the cable through the core several times or use multiple cores on each cable for additional protection. Install line filters on the power input cable to the unit to suppress power line interference. Install them near the power entry point of the enclosure. The following EMI suppression devices (or equivalent) are recommended: Ferrite Suppression Cores for signal and control cables: - Fair-Rite # 0443167251 (RLC# FCOR0000) TDK # ZCAT3035-1330A Steward # 28B2029-0A0 - Line Filters for input power cables: - Schaffner # FN610-1/07 (RLC# LFIL0000) Schaffner # FN670-1.8/07 Corcom # 1 VR3 _Note: Reference manufacturer’s instructions when installing a line filter._ 6. Long cable runs are more susceptible to EMI pickup than short cable runs. Therefore, keep cable runs as short as possible. 7. Switching of inductive loads produces high EMI. Use of snubbers across inductive loads suppresses EMI. Snubber: RLC# SNUB0000. ## **USING THE COLOR CODED WIRES** The low voltage input units will contain three or four color coded wires depending on the backlight power requirements. The high voltage input units will contain (2) orange wires and an additional two or three wires depending on the backlight power requirements. The tables define the function of each colored wire. ## **LOW VOLTAGE INPUT** |**LOW VOLTAGE INPUT**|**LOW VOLTAGE INPUT**|**LOW VOLTAGE INPUT**|**LOW VOLTAGE INPUT**| |---|---|---|---| |Wire Colors|||| |**WHITE**|**BLUE**|**BLACK**|**RED**| |Low Voltage Input|Reset|Common|+Backlight Power| ## **HIGH VOLTAGE INPUT** |**HIGH VOLTAGE INPUT**|**HIGH VOLTAGE INPUT**|**HIGH VOLTAGE INPUT**|**HIGH VOLTAGE INPUT**|**HIGH VOLTAGE INPUT**| |---|---|---|---|---| |Wire Colors||||| |**ORANGE**|**ORANGE**|**BLUE**|**BLACK**|**RED**| |High Voltage<br>Input|High Voltage<br>Input|Reset|Common|+Backlight<br>Power| ## **TERMINAL BLOCK OPTION** **CONNECTIONS** : Wire clamping terminals Wire Strip Length: 0.275" (7 mm) 1 2 3 1 2 3 4 1 2 3 4 5 Wire Gage: 24-16 AWG copper wire _5_ ## **USING THE OPTIONAL TERMINAL BLOCK** 1. Remove the rear cover. Refer to Figure 1. A small slotted screwdriver is required to release the side latches. Insert the screwdriver tip between the rear cover and the side of the unit. Leverage the screwdriver away from the case to unlatch the side latch and slightly lift the rear cover. Pinch the corners to hold the rear cover in place. Remove the screwdriver and repeat the same procedure on the other side of the rear cover. When both side latches are released, slide the rear cover from the unit and the wires. **==> picture [198 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> Side<br>Latches<br>Figure 1<br>**----- End of picture text -----**<br> 2. For safety concerns, the wires should be cut off completely flush with the PC board to prevent a short. 3. Break out the break away tab(s) as required. Remove the left tab only for 3 position terminal block or both tabs for 4 and 5 position terminal blocks. 4. Reinstall the rear cover into CUB7 unit. 5. Mount the CUB7 into the panel (refer to 1.0 Installing The Meter) 6. Push the keyed terminal block onto the exposed PC board. The left most terminal, next to the DIP switch(s) is terminal #1. - _Note: Wire sizes 16-24 AWG may be used with 0.25" length exposed. The screwless type terminal block requires a small slotted screwdriver engaged in the upper slot to open the wire clamp in the lower larger slot. Removing the screwdriver will lock the wire clamp unto the wire._ **==> picture [400 x 206] intentionally omitted <==** **----- Start of picture text -----**<br> Rear Cover<br>Mounting Clip<br>DIP Switch(s)<br>Cut Wires Internally<br>(If using Optional<br>Terminal Block) Side Latches Optional<br>Terminal Block<br>Break-out Tab or Tabs<br>(If using Optional<br>Terminal Block)<br>Open & Lock<br>Wire Clamp<br>Terminal #1<br>**----- End of picture text -----**<br> **==> picture [43 x 37] intentionally omitted <==** Wires must be cut off completely flush with PC board. **==> picture [534 x 237] intentionally omitted <==** **----- Start of picture text -----**<br> Current Sinking Output Current Sourcing Output Logic Output<br>1 2 3 4 1 2 3 4 1 2 3 4<br>+V<br>ON * + BacklightOptional ON * + BacklightOptional ON * + BacklightOptional<br>1 2 3 − Power 1 2 3 − Power 1 2 3 − Power<br>Switch/Contact Sinking Output Switch/Contact Sourcing Output High Voltage<br>1 2 3 4 1 2 3 4 1 2 3 4 5<br>+V 50-250<br>ON * + BacklightOptional ON * + BacklightOptional ON* VDC/VAC + BacklightOptional<br>1 2 3 − Power 1 2 3 − Power 3 − Power<br> Switch position is application dependent. Shaded area for high voltage applications.<br>LV INPUT RESET COMMON +BACKLIGHT POWER LV INPUT RESET COMMON +BACKLIGHT POWER LV INPUT RESET COMMON +BACKLIGHT POWER<br>SRC LO FREQ KEY EN SRC LO FREQ KEY EN SRC LO FREQ KEY EN<br>SNK HI FREQ KEY DIS SNK HI FREQ KEY DIS SNK HI FREQ KEY DIS<br>LV INPUT RESET COMMON +BACKLIGHT POWER LV INPUT RESET COMMON +BACKLIGHT POWER HV INPUT HV INPUT RESET COMMON +BACKLIGHT POWER<br>SRC LO FREQ KEY EN SRC LO FREQ KEY EN KEY EN<br>SNK HI FREQ KEY DIS SNK HI FREQ KEY DIS KEY DIS<br>**----- End of picture text -----**<br> _6_ **This page intentionally left blank.** _7_ ## **LIMITED WARRANTY** The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or as amended hereafter. No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein. The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations. Red Lion Controls Headquarters 20 Willow Springs Circle York PA 17406 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 Red Lion Controls Europe Printerweg 10 NL - 3821 AD Amersfoort Tel +31 (0) 334 723 225 Fax +31 (0) 334 893 793 Red Lion Controls India 201-B, 2nd Floor, Park Centra Opp 32 Mile Stone, Sector-30 Gurgaon-122002 Haryana, India Tel +91 984 487 0503 Red Lion Controls China Unit 101, XinAn Plaza Building 13, No.99 Tianzhou Road ShangHai, P.R. China 200223 Tel +86 21 6113-3688 Fax +86 21 6113-3683 _8_
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →