CCR420PS24
AC/DC Enclosed Power Supply (PSU), ITE, Industrial & Medical, 280 W, 24 V, 17.5 A
- Manufacturer: XP POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (07-Nov-2024)
- Product Range: CCR420 Series
- No. of Outputs: 1 Output
- Output Power Max: 280W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 17.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Medical
- Power Rating (Convection Cooling): 280W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 119.71 € |
| Current stock | 10+ |
| Lead time | 30 days |
CCR420 series ## **Fan Conduction Convection** 420W **cooled** 3 ~~5~~ 0W **cooled** 280W **coo** ~~**l**~~ **ed** **AC-DC power supplies** The CCR420 series of compact medical AC-DC power supplies are designed to operate in convection cooled, conduction cooled, and fan cooled ap ~~plic~~ ations with power r ~~a~~ tings from 280 to 420W. CCR ffers hi ciency and high power density in a low ~~p~~ rofile, baseplate cooled design that ensures effective thermal management and quiet operation for noise sensitive applications. Featuring Class B conducted and radiated emissions, worldwide industrial and medical safety approvals, 2 x MOPP isolation and low leakage currents, the CCR420 is designed for easy integration into a wide range of BF rated medical applications including respiratory care, imaging, patient monitoring, patient treatment, and l applica h as process control, test & measurement, and industrial printing. ## **Featu A ns** ## **Dimensions** - f 420W fan cooled, 350W conduction cooled 129.4 x 83.5 x 25.4mm (5.09" x 3.29" x 1.00") - f Universal, single phase input: 85 to 264VAC f 129.4 x 83.5mm foot 25.4m re Proce ff High efficiency, up to 94% Low earth leakage <300µA ~~*~~ **More resources** f Low patient leakage s ~~é~~ - f Medical (BF) & ITE safety approvals - f Class B conducted and radiated emissions - f 3 year warranty Click the link or scan the code xppower.com ## **Models & ratings** |Model number|Output voltage|Output current<br>Convection cooled<br>Conduction cooled(2)<br>Fan cooled(1)|Output current<br>Convection cooled<br>Conduction cooled(2)<br>Fan cooled(1)|Output current<br>Convection cooled<br>Conduction cooled(2)<br>Fan cooled(1)|Output current<br>Convection cooled<br>Conduction cooled(2)<br>Fan cooled(1)|Output current<br>Convection cooled<br>Conduction cooled(2)<br>Fan cooled(1)|Output current<br>Convection cooled<br>Conduction cooled(2)<br>Fan cooled(1)|Efficiency(3)| |---|---|---|---|---|---|---|---|---| ||||||Conduction cooled(2)||Fan cooled(1)|| |CCR420PS12|12.0V||Convection cooled<br>23.33A|Convection cooled<br>23.33A|Conduction cooled<br>29.17A||35.00A|92.5%| |CCR420PS15|15.0V|18.67A|||23.33A||28.00A|93.0%| |CCR420PS24|24.0V|11.67A|||14.58A||17.50A|94.0%| |CCR420PS28<br>CCR420PS30|28.0V<br>30.0V|10.00A<br>9.33A|||12.50A<br>11.67A||15.00A<br>14.00A|94.0%<br>94.0%| |CCR420PS30<br>CCR420PS36|30.0V<br>36.0V|9.33A<br>7.78A|||11.67A<br>9.72A|11.67A<br>9.72A|14.00A<br>11.67A|94.0%<br>94.0%| |CCR420PS48|48.0V|5.83A|||7.29A||8.75A|94.0%| |CCR420PS54|54.0V|5.19A|||6.48A||7.78A|94.5%| Notes: 1. Requires 37m[3] /h (22CFM) 3. Typical value at 230VAC input and 420W load. 2. Thermal resistance for conduction cooling ≤1.6°C/W. 1 [| **AC-DC power supplies** ## CCR420 series **==> picture [32 x 31] intentionally omitted <==** ## **Input** **==> picture [553 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Input voltage - operating|85(1)|115/230|264|VAC|Derate output linearly – Fan cooled| ||||||Derate output linearly from 350W at 115VAC to 290W at 85VAC<br>– conduction cooled| ||||||Derate output linearly from 225W at 115VAC to 180W at 85VAC<br>– convection cooled| |Input frequency|47|50/60|63|Hz|Agencyapproval,47-63Hz| |Power factor||>0.95|||230VAC,100% load| |Input current - full load|||4.5/2.5|A|115/230VAC| |Inrush current||30||A|240VAC cold start,25°C| |Earth leakage current|||300|µA|264 VAC/60Hz| |No load inputpower|||0.5|W|| |Inputprotection|T6.3A/250 V Internal fuse ftted in line and neutral.||||| (1) Agency approval, 90-264VAC **==> picture [553 x 45] intentionally omitted <==** **----- Start of picture text -----**<br> Output<br>Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Output voltage|12||54|VDC|See models and ratings table| |Initial set accuracy|||±1|%|50% load, 115/230VAC| |Minimum load<br>|No minimum load required||||| |Start updelay|||2|s|115/230VAC full load| |Hold uptime|8|||ms|115VAC full load at 25°C| |Drift|||±0.02|%|After 20 min warm up| |Line regulation|||±0.5|%|| |Load regulation|||±1.0|%|0-100% load| |Transient response|||4|%|Recovery within 1% in less than 500µs for a 50-75% and 75-50% load<br>step| |Output voltage adjustment||±5||%|115VAC Full load| |Ripple & noise|||1|%|Measured at 20MHz bandwidth and 10µF electrolytic capacitor<br>in parallel with 0.1µF ceramic capacitor at 25°C| |Remote sense<br>|Compensates for 5% dropof nominal output voltage||||| |Overvoltageprotection|110||150|%|Vnom, recycle input to reset, 54V model OVP <63V| |Overloadprotection|110||170|%|Inom| |Short circuitprotection<br>|Trip& restart||||| |Temperature coeffcient|||0.02|%/˚C|| |Overtemperatureprotection<br>|Measured internally, auto resetting||||| Specifications subject to change without notice. 2 **AC-DC power supplies** ## CCR420 series **==> picture [31 x 31] intentionally omitted <==** ## **General** **==> picture [554 x 25] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>Efficiency 94 % See models and ratings table<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Effciency||94||%|See models and ratings table| |Isolation: input to output<br>input to ground<br>output toground|4000|||VAC|2 x MOPP| ||1800|||VAC|1 x MOPP| ||1500|||VAC|1 x MOPP| |Switching frequency||65||kHz|Main converter (varies with load)| ||70||140|kHz|PFC (varieswithload)| |Power density|||1.5|W/cm3|Fan cooled| |Patient leakage current|||75|µA|| |Mean time between failure||400||khrs|MIL-HDBK-217F, 25°C GB.| |Weight||470 (1.036)||g(lb)|| ## **Environmental** **==> picture [553 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Operatingtemperature|-40||+80|°C|See deratingcurve, safetyapproved to 50°C| |Storage temperature|-40||+85|°C|| |Cooling|37 (22)|||m3/h (CFM)|For fan cooled operation| |Humidity|5||95|%RH|Non-condensing| |Operating altitude|||4000 / 5000<br>(2000)|m|Medical/ITE OVC II<br>(OVC III)| |Vibration|Single axis 10-500Hz at 2gsweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6||||| |Shock|±3 x 30gshocks in each plane, total 18 shocks. 30g= 11ms (±0.5msecs), half sine. Conforms to EN60068-2-27||||| |Baseplate temperature|||95|°C|When using conduction cooling, max baseplate temperature<br>(measured at the center) is 95°C but some components are not<br>thermally connected to the baseplate. The temperatures of these<br>components may not exceed temperatures shown in the thermal<br>considerations section on page 5.| ## **Derating curve** Input derating curve Thermal derating curve **==> picture [304 x 130] intentionally omitted <==** **----- Start of picture text -----**<br> 440<br>400 Fan cooled (37m�/h air flow)<br>360<br>350<br>320 Conduc�on cooled (1.6°C/W or be�er heatsink)<br>290<br>280<br>240<br>225<br>200 Convec�on cooled<br>180<br>160<br>120<br>80<br>40<br>0<br>85 90 115 145 175 190 200 205 235 264<br>Input Voltage (VAC)<br>Output Power (W)<br>**----- End of picture text -----**<br> **==> picture [223 x 186] intentionally omitted <==** **----- Start of picture text -----**<br> 440<br>400<br>360<br>350<br>320<br>280<br>240<br>225<br>200<br>160<br>120<br>80<br>40<br>0<br>-40 -30 -20 -10 0 10 20 30 40 50 55 60 65 70 80 90<br>Temperature (°C)<br>Fan cooled with 37m�/h air flow at 230VAC<br>Fan cooled with 37m�/h air flow at 115VAC<br>Conduc�on cooled @ 230VAC<br>Conduc�on cooled @ 115VAC<br>Convec�on cooled @ 230VAC<br>Convec�on cooled @ 115VAC<br>Output Power (W)<br>**----- End of picture text -----**<br> Specifications subject to change without notice. 3 **AC-DC power supplies** ## CCR420 series **==> picture [31 x 31] intentionally omitted <==** ## **Emissions - EMC** **==> picture [553 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Notes & conditons| |---|---|---|---| ||||| |Conducted|EN55032/EN55011|Class B|| |Radiated|EN55032/EN55011|Class B|| |Harmonic currents|EN61000-3-2|Class A, C & D|Class C ≥150W| |Voltage ficker|EN61000-3-3||| ## **Emissions - immunity** **==> picture [553 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Criteria Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Criteria|Notes & conditons| |---|---|---|---|---| |||||| |Medical device EMC|IEC60601-1-2|Ed.4.0 : 2014|as below|| |Low voltage PSU EMC|EN55035||as below|| |ESD immunity|EN61000-4-2|4|A|±15kV air, ±8kV contact| |Radiated immunity|EN61000-4-3|10V/m|A|| |EFT/burst|EN61000-4-4|±2kV|A|| |Surge|EN61000-4-5|Installation class 4|A|±2kV line to line, ±4kV line to earth| |Conducted|EN61000-4-6|6V|A|| |Magnetic feld|EN61000-4-8|30A/m|A|| |Dips and interruptions|EN55035<br>(115VAC)|Dip100%(0VAC), 10ms|A|| |||Dip 100% (0VAC), 20ms|A|| |||Dip 30% (80.5VAC), 500ms|B|| |||Dip 60% (46VAC), 100ms|B|| |||Dip 100% (0VAC), 5000ms|B|| ||EN55035<br>(230VAC)|Dip 100% (0VAC), 10ms|A|| |||Dip 100% (0VAC), 20ms|A|| |||Dip 30% (181VAC), 500ms|A|| |||Dip 60% (92VAC), 100ms|A|| |||Dip 100% (0VAC), 5000ms|B|| ||EN60601-1-2<br>(100VAC)|Dip 100% (0VAC), 10ms|A|| |||Dip 100% (0VAC), 20ms|A|| |||Dip 30% (70VAC), 500ms|B|| |||Dip 100% (0VAC), 5000ms|B|| ||EN60601-1-2<br>(240VAC)|Dip 100% (0VAC), 10ms|A|| |||Dip 100% (0VAC), 20ms|A|| |||Dip 30% (168VAC), 500ms|A|| |||Dip 100% (0VAC), 5000ms|B|| ## **Safety approvals** |Certfcaton|Standard|Notes & conditons| |---|---|---| |CB report|IEC62368-1|Audio/video, information and communication technologyequipment| ||IEC60601-1|Medical| |UL|UL62368-1|Audio/video, information and communication technologyequipment| ||ANSI/AAMI ES60601-1 & CSA C22.2 No.60601-1|Medical| |EN|EN62368-1|Audio/video, information and communication technologyequipment| ||EN60601-1|Medical| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| |||| |Isolaton|Standard|Notes & conditons| |Primaryto Secondary|2 x MOPP (Means of Patient Protection)|| |Primaryto Earth|1 x MOPP (Means of Patient Protection)|| |Secondaryto Earth|1 x MOPP (Means of Patient Protection)|| Specifications subject to change without notice. 4 **AC-DC power supplies** ## CCR420 series **==> picture [32 x 31] intentionally omitted <==** ## **Mechanical details** **==> picture [547 x 363] intentionally omitted <==** **----- Start of picture text -----**<br> 129.4 (5.09)<br>Moun�ng inserts ø3.2 (0.13)<br>119.4 (4.70) through 4 places<br>5.0 (0.20)<br>CN1 CN2 AC input connector (CN1): ECE ETB22<br>1<br> 1 68.6<br> 2 2 (2.70) Pin connections<br>+Vo<br>Air flow Pin Function Mating wire range<br>direc�on<br>1 ACL<br>21.9CFM 7.4 14-18AWG<br>-Vo (0.29) 2 ACN<br> 2cm 83.5 Max torque: 0.4 N-m (3.5 lb-in)<br>(3.29)<br>Remote sense (CN2): TKP 8822-02-NHB or equivalent<br>Output<br>Black anodised trim Pin connections<br>Pin Function Mating housing Terminal<br>1 Rs+ JST XHP-2 JST SXH-001T-P0.6N<br>2 Rs- or equivalent or equivalent<br>FG ( ) 25.4 ±0.9<br>M3.5 x 0.6 (1.00 ±0.04)<br>depth 2mm<br>Max Torque: Tc<br>0.7N-m (6.2lb-in)<br>Tc: baseplate temperature measurement point<br>FAN<br>**----- End of picture text -----**<br> Notes: 1. All dimensions shown in mm (inches). Tolerance: ±0.5 (0.02). 3. DC output terminal screws are M4. Max torque: 0.7N-m (6.2lb-in) 2. Weight: Standard versions: 470g (1.036lbs) approx. ## **Thermal considerations** **==> picture [518 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> Temperature measurements (at maximum ambient)<br>Component Max temperature °C<br>F1<br>L1 130°C<br>C37<br>F1 125°C<br>C27 125°C L1 (above T3)Cover C 27<br>C37 125°C<br>21.0<br>Cover (above T3) 100°C<br>(0.83)<br>Baseplate 95°C<br>24.0 (0.94)<br>**----- End of picture text -----**<br> In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of direct air flow). 05 December 2024 **5**
Updated at June 10, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →