Image not available
Illustrative purposes only
CBM-7530B-134
CENTRIFUGAL FANS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SAME SKY / PARTNER STOCK
- Product type: Blowers
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 9 |
| Price | 36.17 € |
| Current stock | 100+ |
| Lead time | 30 days |
**date** 02/07/2020 **page** 1 of 7 ## **SERIES:** CBM-75B **DESCRIPTION:** DC BLOWER **│** ## **FEATURES** - ball bearing design • multiple speed options for different cooling needs ey = • 75 x 75 mm frame • auto restart protection standard on all models — 12 Vo Q Ep Se ® ‘) Bauart gepriift **MODEL input input input rated air static noise[4] voltage current[1] power[1] speed[1] flow[2] pressure[3] rated range max max typ max** (Vdc) (Vdc) (mA) (W) (RPM±10%) (CFM) (inch H2O) (dBA) CBM-7530B-119 12 6~13.8 80 1.0 1900 7.5 0.15 28.0 CBM-7530B-124 12 6~13.8 130 1.6 2400 9.6 0.27 33.9 CBM-7530B-130 12 6~13.8 230 2.8 3000 12.3 0.48 40.5 CBM-7530B-134 12 6~13.8 300 3.6 3400 13.6 0.60 43.5 CBM-7530B-219 24 10~27.6 50 1.2 1900 7.5 0.15 28.0 CBM-7530B-224 24 10~27.6 80 1.9 2400 9.6 0.27 33.9 CBM-7530B-230 24 10~27.6 140 3.4 3000 12.3 0.48 40.5 CBM-7530B-234 24 10~27.6 170 4.1 3400 13.6 0.60 43.5 Notes: 1. At rated voltage, 25°C, 0 inch H20 static pressure, after 10 minutes 2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H20 static pressure 3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow. 4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake. 5. All specifications are measured at 25°C, 65% relative humidity unless otherwise specified. **cuidevices** .com **CUI Devices │ SERIES:** CBM-75B **│ DESCRIPTION:** DC BLOWER **date** 02/07/2020 **│ page** 2 of 7 ## **INPUT** |**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>operating input voltage<br>12 Vdc input models<br>24 Vdc input models<br>6<br>10<br>12<br>24<br>13.8<br>27.6<br>Vdc<br>Vdc<br>starting voltage<br>12 Vdc input models<br>24 Vdc input models<br>6<br>10<br>Vdc<br>Vdc<br>**PERFORMANCE1**<br>**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>rated speed<br>at rated voltage, 25°C, after 10 minutes<br>1900<br>3400<br>RPM<br>air fow<br>at 0 inch H2O, see performance curves<br>7.5<br>13.6<br>CFM<br>static pressure<br>at 0 CFM, see performance curves<br>0.15<br>0.60<br>inch H2O<br>noise<br>at 1 m<br>28.0<br>43.5<br>dBA<br>Note:<br>1. See Model section on page 1 for specifc values.<br>**PROTECTIONS**<br>**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>auto restart<br>when the fan motor is locked by an external force,<br>the device will temporarily turn of electrical power<br>to the motor and restart automatically when the<br>locked rotor condition is released<br>**SAFETY & COMPLIANCE**<br>**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>insulation resistance of frame<br>at 500 Vdc between internal stator and positive<br>lead wire<br>10<br>MΩ<br>dielectric strength<br>apply 500 Vac for 1 minute between housing and<br>positive lead wire<br>safety approvals<br>UL/cUL 507, TUV (EN 60950-1)<br>EMI/EMC<br>EN 61000-6-1:2007, EN 61000-6-3:2007+A1<br>life expectancy<br>at 40°C, 65% RH<br>70,000<br>hours<br>RoHS<br>yes<br>**ENVIRONMENTAL**<br>**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>operating temperature<br>-10<br>70<br>°C<br>storage temperature<br>-40<br>70<br>°C<br>CONTINUED| |---| **cuidevices** .com **CUI Devices │ SERIES:** CBM-75B **│ DESCRIPTION:** DC BLOWER **date** 02/07/2020 **│ page** 3 of 7 ## **PERFORMANCE CURVES** ## **CBM-7530B-119** ## **CBM-7530B-124** **==> picture [560 x 509] intentionally omitted <==** **----- Start of picture text -----**<br> 6 12<br>0.2 0. 4<br>4 8<br>0.1 0. 2<br>2 4<br>0 0<br>0 5 10 CFM 0 5 10 CFM<br>0 0.142 0.284 0 0.142 0.284<br>CMM CMM<br>Air Flow Air Flow<br>CBM-7530B-130 CBM-7530B-134<br>24 30<br>0.8 1.0<br>16 20<br>0.4 0.5<br>8 10<br>0 0<br>0 10 20 CFM 0 10 20 CFM<br>0 0.28 0.56 0 0.28 0.56<br>CMM CMM<br>Air Flow Air Flow<br>mm H O inch H O mm H O inch H O<br>Static Pressure<br>2 2 2 2<br>mm H O inch H O mm H O inch H O<br>Static Pressure Static Pressure<br>**----- End of picture text -----**<br> **cuidevices** .com **CUI Devices │ SERIES:** CBM-75B **│ DESCRIPTION:** DC BLOWER **date** 02/07/2020 **│ page** 4 of 7 ## **PERFORMANCE CURVES (CONTINUED)** ## **CBM-7530B-219** ## **CBM-7530B-224** **==> picture [561 x 511] intentionally omitted <==** **----- Start of picture text -----**<br> 6 12<br>0.2 0.4<br>4 8<br>0.1 0.2<br>2 4<br>0 0<br>0 5 10 CFM 0 5 10 CFM<br>0 0.142 0.284 0 0.142 0.284<br>CMM CMM<br>Air Flow Air Flow<br>CBM-7530B-230 CBM-7530B-234<br>24 30<br>0.8 1.0<br>16 20<br>0.4 0.5<br>8 10<br>0 0<br>0 10 20 CFM 0 10 20 CFM<br>0 0.28 0.56 0 0.28 0.56<br>CMM CMM<br>Air Flow Air Flow<br>2 2 2 2<br>mm H O inch H O mm H O inch H O<br>Static Pressure Static Pressure<br>2 2 2 2<br>mm H O inch H O mm H O inch H O<br>Static Pressure Static Pressure<br>**----- End of picture text -----**<br> **cuidevices** .com **CUI Devices │ SERIES:** CBM-75B **│ DESCRIPTION:** DC BLOWER **date** 02/07/2020 **│ page** 5 of 7 ## **MECHANICAL** |**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>motor<br>4 pole DC brushless<br>bearing system<br>ball bearing<br>direction of rotation<br>counter-clockwise viewed from front of fan blade<br>dimensions<br>75.7 x 75.7 x 30<br>mm<br>material<br>PBT (UL94V-0)<br>weight<br>86.5<br>g<br>**MECHANICAL DRAWING**<br>WIRE CONNECTIONS<br>Wire Color<br>Function<br>Red<br>+Vin<br>Black<br>-Vin<br>units: mm<br>wire: UL 1007, 26 AWG<br>DISCONTINUED<br>ROTATION<br>AIR<br>FLOW<br>[—_____.&<br>75.7205<br>30+0.3<br>><br>24.1+0.3<br>37.9+0.3<br>3,540.3<br>2+03<br>24.5405<br>£<br>!<br>7<br>8<br>'<br>Ak<br>i<br>LO<br>:<br>3<br>*<br>id<br>-<br>=a—<br>5+0.3<br>Se<br>-<br>a<br>(—<br>£3><br>Xo,<br>a<br>2-R3.7208| |---| units: mm wire: UL 1007, 26 AWG **cuidevices** .com **CUI Devices │ SERIES:** CBM-75B **│ DESCRIPTION:** DC BLOWER **date** 02/07/2020 **│ page** 6 of 7 ## **SAFETY CONSIDERATIONS** 1. Do not use or operate this fan in excess of the limitations set forth in this specification. CUI is not responsible for the non-performance of this fan and/or any damages resulting from its use, if it is not used or operated in accordance with the specifications. 2. CUI recommends adding a protection circuit to the product or application in which this fan is installed, such as a thermo-fuse, or current fuse or thermo-protector. The failure to use such a device may result in smoke, fire, electric shock by insulation degradation in cases of motor lead short circuit, overload, or over voltage, and/or other failure. 3. CUI recommends installing a protection device to the product or application in which this fan is installed if there is a possibility of reverse connection between Vdc (+) and GND (-). The failue to install such a device may result in smoke, fire, and/or destruction, although these conditions may not manifest immediately. 4. This fan mush be installed and used in compliance with all applicable safety standards and regulations. 5. Use proper care when handling and/or installing this fan. Improper handling of installation of this fan may cause damage that could result in unsafe conditions. 6. Use proper care during installation and/or wiring. Failure to use proper care may cause damage to certain components of the fan including, but not limited to, the coil and lead wires, which could result in smoke and/or fire. 7. Do not use power or ground PWM to control the fan speed. If the fan speed needs to be adjusted, please contact CUI to customize the product design for your application. 8. For critical or extreme environments, including non-stop operation, please contact CUI and we will gladly provide assistance with your product selection to ensure an appropriate cooling product for your application. 9. When building your device, please examine thouroughly any variation of EMC, temperature rise, life data, quality, etc. of this product by shock/drop/vibration testing, etc. If there are any problems or accidents in connection with this product, it should be mutually discussed and examined. 10. Use proper care when handling these fans. Components such as fan holders or bearings may be damaged, if touched with fingers or other objects. Additionally, static electricity (ESD) may damage internal circuits of the fan. 11. Do not operate these fans in proximity to hazardous materials such as organic silicon, cyanogens, formalin, phenol, or corrosive gas environments including, but not limited to, H2S, SO2, NO2, or Cl2. 12. CUI recommends that you protect these fans from exposure to outside elements such as dust, condensation, humidity, or insects. Exposure of this fan to such elements may affect its performance and my cause safety hazards. CUI does not warrant against damage to the product caused by outside elements. 13. The fans must be installed properly and securely. Improper mounting may cause harsh resonance, vibration, and noise. 14. Do not store these fans in an environment with high humidity. These fans must be stored in accordance with the specified storage temperature. 15. CUI reserves the right to use components from multiple sources at its discretion. The use of components from other sources will not affect the specifications as described herein. 16. The life expectancy of these fans has not been evaluated for use in combination with any end application. Therefore, the life expectancy that relate to these fans are only for reference. **cuidevices** .com **CUI Devices │ SERIES:** CBM-75B **│ DESCRIPTION:** DC BLOWER **date** 02/07/2020 **│ page** 7 of 7 ## **REVISION HISTORY** |**rev.**<br>|**description**<br>|**date**<br>| |---|---|---| |1.0<br>|initial release<br>|08/02/2017<br>| |1.01<br>|brand update<br>|02/07/2020<br>| The revision history provided is for informational purposes only and is believed to be accurate. CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. **cuidevices** .com
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →