Image not available
Illustrative purposes only
BM1R16MV1
ANALOGUE TIMERS - DIN RAIL TIMERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET / PARTNER STOCK
- Product type: Analogue Timers - DIN Rail
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 135.0 € |
| Current stock | 50+ |
| Lead time | 30 days |
## **BM1R** Timers Syrline 17.5 mm - 1 Relay 16A › Multi Multi ~~-~~ function or mono function or mono- ~~f -~~ function unction › Multi Multi. ~~-~~ range (12 function) range (12 function)eas › Multi Multi ~~-~~ voltage 12 →240 V AC/DC voltage 12 240 V AC/DC › LED status indicator (relay version) LED status eindicator° (relay version)° › Possibility of external load connection in parallel to the Possibilityvtrol input of external load connection in parallel to the control input › 3 co3 ~~-~~ n wire PNP sensor compatible wiretrol input PNP sensor compatible |Specifications|Specifications||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Functions||Delay||Output|Nominal rating<br>Connections|||||Supply voltage|||Code| |A - Ac - At - B - C - D - Di -||0,5 s →10 days|0,5 s →10 days|1 changeover relay|16 A|||Screw terminals||12 →240 V ∿/⎓|||BM1R16MV1| |H - Ht -N - TL - Tt|||||||||||||| ||||||||||||||| |Output relay|||||||||||||| |Contact arrangement||||||1 CO (SPDT) (ChangeOver -Simple Pole Double Throw-)|||1 CO (SPDT) (ChangeOver -Simple Pole Double Throw-)|||1 CO (SPDT) (ChangeOver -Simple Pole Double Throw-)|| |Maximum switching voltage||||||250 VAC/ 16 A resistive / 250 VDC / 0.3 A resistive|||250 VAC/ 16 A resistive / 250 VDC / 0.3 A resistive||||| |Switching current rate (resistive)||||||NO / NC: 16 A 250 V AC / 16 A 30 VDC @ 25°C|||NO / NC: 16 A 250 V AC / 16 A 30 VDC @ 25°C|||NO / NC: 16 A 250 V AC / 16 A 30 VDC @ 25°C|| |||||||NO / NC: 8 A 250 V AC / 8 A 30 VDC @ 60°C|||NO / NC: 8 A 250 V AC / 8 A 30 VDC @ 60°C||||| |Minimum switching contact||||||10 mA / 5 VDC|||||||| |Maximum switching power (resistive)||||||4000 VA / 90 W @ 25°C|||||||| |Electrical life||||||30x103cycles (NO) at 250 VAC/ 16 A resistive|||||||| |Maximum rate (at max switching power)||||||360 cycles /hour|||||||| |Mechanical life||||||30 x 106cycles|||||||| |Rated impulse voltage||||||5 kV (1.2/50µs)|||||||| |Dielectric strength between coil / contacts|||Dielectric strength between coil / contacts|||IEC 60664-1: 5 kV /1 min / 1 mA / 50 Hz|||||||| |Dielectric strength between open contacts|||Dielectric strength between open contacts|||1 kV /1 min / 1 mA / 50 Hz|||||||| ||||||||||||||| |Timing|||||||||||||| |Timing ranges (7 ranges)||||||0.5→10s, 0.05→1min, 0.5→10min, 0.05→1h, 0.5→10h, 0.05→1day,|||||||| |||||||0.5→10days|||||||| |Minimum pulse duration typically (relay version)|||Minimum pulse duration typically (relay version)|||IEC 1812-1: 30 ms / 100 ms with load|||||||| |Maximum reset time by de-energisation typically (relay version)||||||IEC 1812-1: 120 ms|||||||| |Repeatability||||||IEC 1812-1: ≤ ± 0,5 %|||||||| |Repetition accuracy with constant parameters||||||IEC 1812-1: ≤ ± 10 %|||||||| |Drift Temperature||||||≤ ± 0.05 % / °C|||||||| |Voltage-dependent drift||||||≤ ± 0.2 % / V|||||||| ||||||||||||||| |Supply|||||||||||||| |Multi-voltage power supply||||||12→240 V∿/⎓|||||||| |Operating range||||||15 %, +10 %|||||||| |Operating frequency (Hz)||||||50 / 60 Hz ± 5 %|||||||| **I** Timers **I 02** **I** www.crouzet-control.com |Supply|Supply| |---|---| |Galvanic isolation|No| |Max. absorbed power|Approx. 3 VA (V∿) 1.5 W (V⎓)| |Immunity from micro power cuts|10 ms| ||| |General characteristics|| |Insulation voltage, IEC 60664-1|300 V| |Installation category (acc. to IEC/EN 60664-1)|Overvoltage category III ; pollution degree 2| |Impulse voltage CEI/EN 60664-1|4 kV (1,2 / 50 µs)| |Clearance / Creepage distances|IEC 60664-1: 3 mm / 3.2 mm| |Breakdown voltage|EN-61812-1: 2,5 kV / 1 min / 1 mA / 50 Hz| |Insulation resistance|NFC 93 050: > 500 MΩ / 250 V⎓ / 1min| |Status indication|Un: green LED blinks when count, continuous ON when supplied<br>R: yellow LED continuous ON when the relay is ON| |Casing|DIN 43880: 17,5 mm| |Fixing: Symmetrical DIN rail|EN 50022: 35 mm| |Mounting position|All positions| |Housing material|Enclosure plastic type UL94 - V0| |Protection (IEC/EN 60529)|Housing: IP40 / Terminal block: IP20| |Terminal capacity Single-wire without ferrule|IEC 60947-1<br>1 x 0.5 →3.3 mm² (AWG 20 →AWG 12)<br>2 x 0.5 →1.5 mm² (AWG 20 →AWG 16)| |Max. tightening torque (Nm)|IEC 60947-1: 0,5 N.m / 4,4 lbf.in| |Operating temperature range (°C)|IEC 60068-2: -20 °C →+60 °C| |Storage temperature range (°C)|IEC 60068-2: -40 °C →+70 °C| |Relative humidity no condensation acc. to IEC/EN 60068-2-30|93 % without condensation| |Vibration resistance according to IEC/EN 60068-2-6|± 0.15 mm from 10 Hz →60 Hz 2g from 60 Hz →150 Hz| |Impact resistance|IEC 60068-2-27<br>15gn - 11ms ; 3 x 6 axis (output OFF)<br>5gn - 11ms ; 3 x 6 axis (Output ON)| |Drop to concrete floor|IEC 60068-2-32<br>High: 0.75m| |Weight: casing 17,5 mm|70 g<br>80 g with packaging| |Directives|2014/30/EU: EMC<br>2014/35/EU: low voltage| |Certifications|CE - cULus Listed Industrial Control Equipment - CCC| |Conformity to standards|CEI 60664-1: Insulation coordination for equipment within low-voltage<br>systems<br>CEI 61812-1/ Specified time relays for industrial use<br>UL 60947-4-1/ Industrial Control Equipment (NRNT- Industrial Control<br>Switches)| |Conformity with environmental directives|2015/863/UE: RoHS<br>1907/2006: Reach<br>2012/19/UE: WEEE| |Electromagnetic compatibility IEC 61000-6-2, IEC 61000-6-3,<br>IEC 61000-6-4|Immunity for industrial environment<br>Emission residential environment<br>Emission industrial environment| |Electromagnetic compatibility - Immunity to electrostatic discharges<br>acc to IEC/EN 61000-4-2|Level III Air ± 8 KV / Contact ± 6 KV| |Immunity to radiated, radio-frequency, electromagnetic field acc.<br>IEC/EN 61000-4-3|Level III<br>10 V/m (80 M Hz to 1 G Hz) 80 % AM (1 k Hz)<br>3 V/m (1,4 →2 G Hz) 80 % AM (1K Hz)<br>1V/m (2 →2.7 G Hz) 80 % AM (1K Hz)| |Immunity to rapid transient bursts acc. to IEC/EN 61000-4-4|Level III direct ± 2 kV (power supply) / capacitive coupling clamp<br>± 1 KV (command input and outputs)| **I** Timers **I 03** **I** www.crouzet-control.com ## General characteristics |General characteristics|General characteristics| |---|---| |Immunity to shock waves on power supply acc. to IEC/EN 61000-4-5|Level III<br>line-to-earth ± 2 kV / line-to-line ± 1kV| |Immunity to radio frequency in common mode acc. to<br>IEC/EN 61000-4-6|Level III<br>10 Vrms (0,15 →80 M Hz) 80 % AM (1 k Hz)| |Immunity to voltage dips and breaks acc. to IEC/EN 61000-4-11|Industrial Class II:<br>0 % residual voltage during 1cycle a.c. power ports<br>70 % residual voltage during 25/30 cycles a.c. power ports<br>0 % residual voltage, 250/300 cycles a.c. power ports<br>Residential:<br>0 % residual voltage during 10 cycle a.c.power ports<br>40 % residual voltage during 10 cycles a.c. power ports<br>70 % residual voltage during 10 cycles a.c. power ports<br>0 % residual voltage, 250/300 cycles a.c. power ports| |Mains-borne and radiated emissions acc. to EN 55022 (CISPR22),<br>EN55011 (CISPR11)|EN 55022 / CISPR22 Class B (IT equipment)<br>EN 55011 / CISPR11 Class B, Group 1 (Medical equipment)| Curves Function A U Delay on energisation 1 relay R T ~~ee~~ Function Ac U ~~ee~~ Timing after closing and opening of control contact 1 relay Y1 ~~——|~~ R T T Function At U Timing on energisation with memory 1 relay Y1 ~~—~~ R ~~rt[tt]~~ t1 t2 T = t1+t2 Function B U ~~——~~ Timing on impulse one shot 1 relay Y1 ~~Sl~~ R ∞ T Function C U Timing after impulse 1 relay Y1 ~~a|~~ R ∞ T Function D U ~~———~~ Flip-flop Pause start 1 relay Y1 ~~Ppa~~ R T T ~~Beeeeers~~ Function Di U Flip-flop Pulse start 1 relay Y1 ~~|[pecee]~~ R ~~st~~ — jtne ~~e~~ —eenetn ~~ano~~ — - ~~4~~ T T Function H U Timing on energisation 1 relay R ~~SS~~ T **I** Timers **I 04** **I** www.crouzet-control.com |Curves|Curves|Curves|Curves|Curves|Curves|Curves|Curves| |---|---|---|---|---|---|---|---| |Function Ht<br>Delay on energisation with memory 1 relay|t1<br>R<br>Y1<br>U<br>t2<br>T=t1+t2<br>~~a~~<br>~~a~~||||||| |Function N<br>Watchdog|T<br>R<br>Y1<br>U<br>∞<br>T<br>~~Le~~<br>~~a~~<br>~~aaa~~||||||| |Function Tl<br>Timed impulse relay|U<br>Y1<br>R<br>T<br>t<br>~~_~~||||||| |Function TL<br>Impulse relay|U<br>Y1<br>R||||||| ||||||||| |||~~LT~~|||||| ||||||||| ||||||||| ||||||||| |||~~rt~~|~~rttt~~||~~tt~~|~~tt~~|| |||~~rt~~|~~rttt~~||~~tt~~|~~tt~~|| |||~~rt~~|8<br>~~rttt~~||8<br>~~tt~~|8<br>~~tt~~||
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →