Image not available
Illustrative purposes only
BD60
DIGITAL PANEL METERS DUAL 6-DIGIT L
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type: Digital Panel Meters
- SVHC: No SVHC (07-Nov-2024)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 370.85 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Digital Panel Meters Modular Indicator and Controller for pulse signals Type UDM60** - **Dual 6-DGT µP-based controller with analogue indicators** - **Dual rate, speed, frequency and period measurement** - **Dual counter** - **0.001% RDG basic accuracy** - **Range from 0.001Hz to 50kHz/20µs to 1000s** - **Scalable inputs and counters** - **Linearization of the inputs up to 16 points** - **Special calculation functions** - **NPN, PNP, NAMUR, TTL, Pick-up, free of voltage contacts and AC signal inputs** - **Up to 4 independent alarm set-points (optional)** - **20mA/10VDC analog output (optional)** - **Serial port RS485 or RS232 (optional)** - **Backlighted LCD display** - **MODBUS, JBUS communication protocol** - **Front protection degree: IP67, NEMA12, NEMA4x "Indoor use only"** **Product Description How to order UDM60 XXX XX XX X XX** µp-based digital panel means of optional UdmSoft **Model** meter, dual 6-DGT LCD indisoftware. UDM60 includes **Slot A** cator with analogue indicastorage min-max functions **Slot B** tors, for rate, speed, freand double level protection **Slot C** quency and period measurepassword. Housing for pan- **Slot D** ments. Measuring ranges, el mounting with front pro- **Options** ~~On~~ scaling and functions easily tection degree: IP67, ~~Ee]~~ programmable from the keyNEMA12, NEMA4x "Indoor **How to order UdmSoft-kit** pad or from the PC by use only". **UdmSoft-kit:** software plus communication cable for programming UDM60 by means of PC. **UdmSoft:** software for programming UDM60 by means of PC, downloadable from www.carlogavazzi.com. ## **T e Selection yp** ## **Slot A (measuring inputs)** ## **Slot B (communication)** ## **Slot C (communication and alarm)** ## **Slot D (power supply)** **XX:** None **SX:** Serial port RS485 **SY** : Serial port RS232 **TF1:** 0.001Hz to 50kHz for DC signals: PNP, **SX:** Serial port RS485 NPN, NAMUR, TTL, **SY** : Serial port RS232 free of voltage, con- **AV(*):** Single analogue outtacts, voltages up to put, 0 to 20mA DC 14VDC and 0 to 10V DC **TF2:** 0.001Hz to 50kHz for AC signals: pick-up, **(*):** The two analogue voltages up to outputs cannot be 500VAC used at the same time. It is possible to plug in only one module by instrument. **XX:** None **R1:** Single relay output, (AC1-8AAC, 250VAC) **R2:** Dual relay output, (AC1-8AAC, 250VAC) **R4:** Dual relay output, (AC1-8AAC, 250VAC) + dual open collector output (NPN, 100mA) **R5:** 4 relay outputs (AC15AAC, 250VAC) **AV(*):** Single analogue output, 0 to 20mA DC and 0 to 10V DC **H:** 90 to 260V AC/DC **L:** 18 to 60V AC/DC (24 to 48V AC/DC ± 25% according to UL) **3:** 10 to 28V DC (12 to 24V DC ± 15% according to UL) **Options** **XX:** None **TX:** Tropicalization **1** Specifications are subject to change without notice UDM60 DS ENG 090112 **UDM60** ## **In ut s ecifications p p** |**Input specifications**|| |---|---| |**Analogue inputs**|Channels and variables| |BQ TF1 module|2, 0.001Hz to 50kHz for DC<br>signals: PNP, NPN,| ||NAMUR, TTL, free of volt-| ||age contacts, voltages up<br>to 14VDC.| |BQ TF2 module<br>ON signal minimum time<br>duration<br>Rotation speed detection<br>**Type of input**<br>NPN (DC)<br>PNP (DC)|2, 0.001Hz to 50kHz for AC<br>signals: pick-up, voltages<br>up to 500VAC.<br>0.001Hz to 50kHz, 10µs.<br>Max 1kHz,dutycycle 50%.<br>Signal level: ON < 2VDC,<br>OFF open collector (leak-<br>age current <=1mA).<br>Signal level: ON >10VDC,<br>OFF open collector (leak-<br>age current <=1mA).| |NAMUR (DC)|Signal level: ON <=| ||1mADC, OFF >= 2.2| ||mADC.| |TTL (DC)|Signal level: ON >4VDC,| |Free of voltage contact(DC)<br>Voltage (AC) up to 100VAC<br>Voltage (AC) up to 500VAC<br>**Digital inputs**|OFF<=2VDC.<br>Input load: ON <1kohm,<br>OFF >20kohm.<br>Signal level: ON > 2VAC<br>(5.65 Vpp).<br>Signal level: ON > 9VAC<br>(25.4 Vpp).<br>Included in the measuring| |Number of inputs<br>Use|module.<br>1 (contact).<br>- display HOLD command| ||- key-pad disabling| ||- latch alarm reset| ||- counter(s) reset| ||- latch and counter reset| |---|---| |Contact reading signal|BQ TF1: <6 mA, <7 VDC| ||BQ TF2: <0.25 mA, <3 VDC| |Close contact resistance|Max 1kΩ.| |Open contact resistance|Min 100kΩ.| |Insulation|Non-insulated.| |**Accuracy (display, RS485)**|See table “Measuring| ||accuracy”, temperature| ||drifts and minimum/maxi-| ||mum indications”| |**Additional errors**|| |Humidity|0.05% RDG, 60% to 90%| ||R.H.| |Magnetic field|0.05% RDG @ 400 A/m.| |**Temperature drift**|See table “Measuring| ||accuracy”, temperature| ||drifts and minimum/maxi-| ||mum indications”| |**Display**|2 lines, 6-digit + 2 ana-| ||logue indicators.| ||7 segments.| ||h= 10.0 mm| |**Max and min indication**|See table “Measuring| ||accuracy”, temperature| ||drifts and minimum/maxi-| ||mum indications”| |**Measurements**|| |Up to 1 kHz|Zero-crossing detection.| |From 1 kHz|Zero-crossing detection| ||with divisor.| |**Input impedance**|See table “Input| ||impedance and overflow”| |**Overloads**|See table “Input| ||impedance and overflow”| ## **Measurement accuracy, temp. drifts, max and min indications** All accuracies and min/max indications are referred to an ambient temp. range of 25°C ±5°C, rel. humidity ≤60% and scale ratio (electrical/displayed scale) equal to 1. |**Module**|**Input type**|**Accuracy**|**Temp. drift**|**Min indication (**I**)**|**Max indication**| |---|---|---|---|---|---| |BQ TF1|NPN (DC)<br>PNP (DC)<br>NAMUR (DC)<br>TTL (DC)<br>Free of voltage<br>contact (DC)|0.001% RDG<br>±3 digit|± 50 ppm/°C|0.00000<br>00.0000<br>000.000<br>0000.00<br>00000.0<br>000000|9.99999<br>99.9999<br>999.999<br>9999.99<br>99999.9<br>999999| |BQ TF2|Pick-up (AC)<br>Voltage (AC) up to<br>100VAC<br>Voltage (AC) up to<br>500VAC|0.001% RDG<br>±3 digit|± 50 ppm/°C|0.00000<br>00.0000<br>000.000<br>0000.00<br>00000.0<br>000000|9.99999<br>99.9999<br>999.999<br>9999.99<br>99999.9<br>999999| ( I ) The min indication is -9.99999, ..., -999999 in case of “rotation speed detection” function **2** Specifications are subject to change without notice UDM60 DS ENG 090112 **UDM60** ## **In ut im edance and overloads p p** |**Module**|**Input type**|**Impedence**|**Overload (continuos)**|**Overload (1s)**| |---|---|---|---|---| |BQ TF1|NPN (DC)<br>PNP (DC)<br>NAMUR (DC)<br>TTL (DC)<br>Free of voltage contact<br>(DC)|600Ω<br>600Ω<br>600Ω<br>600Ω|15 VAC/DC<br>15 VAC/DC<br>15 VAC/DC<br>15 VAC/DC<br>15 VAC/DC|20 VAC/DC<br>20 VAC/DC<br>20 VAC/DC<br>20 VAC/DC<br>20 VAC/DC| |BQ TF2|Pick-up (AC)<br>Voltage (AC) up to<br>100VAC<br>Voltage (AC) up to<br>500VAC|220 kΩ<br>950 kΩ|120 VAC/DC<br>600 VAC/DC|200 VAC/DC<br>600 VAC/DC| ## **Out ut s ecifications p p** |**RS422/RS485**|**(on request)**||down alarm,| |---|---|---|---| ||Module: BR SX||down alarm with| |Serial output<br>LED|Bidirectional (static and<br>dynamic variables).<br>Display of data||start-up deactivation<br>up alarm with latch,<br>down alarm with latch| |Connections<br>Distance<br>Terminalization<br>Addresses<br>Protocol<br>Data (bidirectional)<br>Dynamic (reading only)<br>Static (reading/writing)<br>Data format<br>Baud rate|reception/transmission<br>Multidrop, 2 or 4 wires,<br>1000 m<br>Directly on the module<br>by means of jumper<br>1 to 247, selectable<br>by means of key-pad<br>MODBUS RTU/JBUS<br>Measurement, min value<br>max value<br>alarm status<br>All programming parameters,<br>min max reset<br>reset of latch alarm<br>8 data bit, no parity,<br>1 stop bit<br>selectable 4800, 9600,19200<br>and 38400 bit/s|Alarm set-point<br>Hysteresis<br>On-time delay<br>Off-time delay<br>Output status<br>Min response time<br>Output channels<br>Relay output BO R1, R2, R4|Adjustable from 0 to 100%<br>of displayed electric range<br>0 to 100% of displayed range<br>0 to 255 s<br>0 to 255 s<br>Selectable: normally energized<br>/de-energize<br>500 ms, with filter excluded,<br>without alarm activation delay<br>1 with module BO R1<br>(relay output).<br>2, independent with module<br>BO R2 (2 relay outputs).<br>4, independent with module<br>BO R4 (2 relay outputs +<br>2 open collector outputs).<br>BO R5 (4 relay outputs)<br>Type SPST<br>AC 1: 8A, 250VAC| |Insulation|By means of opto-couplers||DC 12: 5A, 24VDC| ||4000 Vrmsoutput to||AC 15: 2.5A, 250VAC| ||measuring inputs||DC 13: 2.5A, 24VDC| ||4000 Vrmsoutput to<br>power supplyinput|Relay output BO R5|Type SPST (NO)<br>AC 1: 5A, 250VAC| |**RS232**|**(on request)**||DC 12: 3A, 24VDC| ||Module: BR SY||AC 15: 1,5A, 250VAC| |Serial output|Bidirectional (static and||DC 13: 1,5A, 24VDC| ||dynamic variables)|Insulation|4000 VRMSoutput to| |Connections|3 wires,||measuring input,| |Distance|max. 15m||4000 VRMSoutput to| |Data format|1 start bit, 8 data bit,||power supply input.| ||no parity, 1 stop bit|Open collector output|NPN transistor type| |Baud rate|Selectable 4800, 9600,||VON1.2 VDC/ max. 100 mA| ||19200 and 38400 bit/s||VOFF30 VDC max.| |Other features|Same as RS422/485|Insulation|By means of opto-couplers| |**Alarm outputs**|**(on request)**||4000 VRMSoutput to| |Alarm type|Over-range alarm,||| ||up alarm,||| **3** Specifications are subject to change without notice UDM60 DS ENG 090112 **UDM60** ## **Output specifications (cont.)** ||measuring input| |---|---| ||4000 VRMSoutput to| ||power supplyinput| |**Analogue output**|**(on request)**| ||Module: BO AV| |Range|0 to 20 mADC, 0 to 10 VDC| |Scaling factor|Programmable within the| ||entire retransmission range;| ||allows to manage the| ||retransmission of all the| ||values from| ||0 to 20 mA / 0 to 10V| |Accuracy|± 0.2% FS (@ 25°C ± 5°C)| |Response time|≤10 ms| |Termperature drift|± 200 ppm/°C| |Load: 20 mA output|≤700Ω| |10 V output|≥10 kΩ| |Insulation|By means of opto-couplers| ||4000VRMSoutput to| ||measuring input| |---|---| ||4000VRMSoutput to| ||power supply input| |Notes:|The two outputs cannot be| ||used at the same time.| |**Excitation output**|8.2 VDC ±10%, max 10mA| ||13 VDC ±10%, max 40mA| |Isolation|25 Vrms between aux.| ||output and measuring| ||inputs 4000 VRMSbetween| ||aux. output and the other| ||input/outputs| ## **Software functions** |**Software functions**|| |---|---| |**Password**|Numeric code max 4 dgt| ||2 levels of data protection.| ||1st level 0 to 4999 com-<br>pletely protected. 2nd level| ||5000 to 9999 access to<br>programming is protected,<br>while alarm set-points are| ||directly programmable| |**Scaling parameters**<br>Pulse per revolution|from the measuringmode**.**<br>Programmable and inde-<br>pendent per each channel| ||(only in case of dual fre-| ||quency meter), from 1 to| ||9999.| |Input engineering unit|Programmable among Hz,| ||kHz, rpm, krpm, rph, krph,| |Scaling|and independent per each<br>channel (only in case of<br>dual frequency meter).<br>Selection of the decimal<br>point, min value and max<br>value of the input range<br>(expressed in engineering<br>units). Selection of the dec-<br>imal point, min value and<br>max value of the displayed| ||range correspondent to the| ||input range.| |**Linearisation**|Programmable and inde-<br>pendent per each channel<br>(only in case of dual fre-| ||quency meter).| |Points|Up to 16| |Range|Input value and displayed| ||value of each point within| ||the programmable input| ||and displayrange| |**Filter**|| |Operating range|0 to 100% of the displayed<br>value of channel A| |Filtering coefficient|1 to 32| |Filter action|On measurements, serial| |---|---| ||output,analogue output| |**Operating modes**|See “list of selectable func-| ||tions and variables”| |**Displayed values**|See “list of selectable func-| ||tions and variables”| |**Min max storage**|Automatic storage (in the| ||EEPROM) of the minimum| ||and maximum measured| ||values from the previous| ||memoryreset| |**Setpoint modification**|Direct access to the set-| ||point modification from the| ||measuring mode (if allowed| ||bythe selectedpassword).| |**Latch alarm reset**|Direct access to the reset| ||from the measuringmode.| |**Counter reset**|Direct access to the reset| ||from the measuringmode.| |**Analogue indicators**|11 positions (9 values| ||between the minimum dis-| ||play value and the max-| ||imun display value, under-| ||flow and overflow) or| ||speed rotation direction.| |**Diagnostic**|| |Overflow/Underflow|Analogue indicator over-| ||flow or underflow position| |Display over range|“EEE” indication| |Electrical full scale or overload|“Err” indication| |**UdmSoft**|Software for programming| ||UDM60 by means of PC| ||(Windows 95, 98se, ME,| ||XP) by means of serial port| ||RS485 and relevant con-| ||nection cable. The soft-| ||ware is available in English,| ||Spanish, Italian, German,| ||French. See also “Pro-| ||gramming of UDM60 by| ||means of PC”.| **4** Specifications are subject to change without notice UDM60 DS ENG 090112 **UDM60** ## **General s ecifications p** |**Operating temperature**|0°C to +50°C (32°F to| |---|---| ||122°F) (R.H.≤90% non-| ||condensing)| |**Storage temperature**<br>**Insulation reference voltage**<br>**Insulation**<br>**Dielectric strength**|-10°C to +60°C (-14°F to<br>140°F) (R.H.≤90% non-<br>condensing)<br>300 VRMSto ground (500V<br>input)<br>See table “Insulation<br>between input and outputs”<br>4000 VRMS for 1 minute| |**Noise rejection**<br>NMRR<br>CMRR<br>**EMC**|40dB, 40 to 60 Hz<br>100 dB,48 to 62 Hz<br>EN61000-6-2, IEC61000-6-2| ||EN61000-6-3,IEC61000-6-3| |**Standard compliance**|| |Safety|EN61010-1, IEC61010-1| |**Connections**|Screw-type| |---|---| |Cable cross-section area|Max. 2.5 mm2;| ||Min./Max. screws tighten-| ||ingtorque: 0.4 Nm / 0.6 Nm| |**Housing DIN**|| |Dimensions (WxHxD)|48 x 96 x 105 mm| |Material|PC-ABS,| ||self-extinguishing: UL 94 V-0| |**Protection degree**|| |Front|IP67, NEMA12, NEMA4x| ||"Indoor use only"| |Screw terminals|IP20| |**Weight**|Approx. 520 g (packing| ||included)| |**Approvals**|CE, cCSA UL e cRU US| ## **Su l S ecifications pp y p** |**AC/DC voltage**|90 to 260V (standard)| |---|---| ||18 to 60V (on request)<br>(24 to 48V AC/DC ± 25%<br>accordingto UL)| |**DC voltage only**|10 to 28V (on request)| ||(12 to 24V DC ± 15%| ||according to UL)| |**Energy consumption**|≤30VA/12W (90 to 260V)| |---|---| ||≤20VA/12W (18 to 60V)| ||≤7.5W (10 to 28V)| ## **Excitation output** ## **Insulation between inputs and outputs** |Continuous (8.2V)<br>BQ TF1<br>BQ TF1<br>(8.2V)<br>Max 30s (8.2V)<br>Continuous<br>Max<br>30s|||Meas.<br>inputs|Relay<br>output|Static<br>output|Analogue<br>output|Serial<br>Port|AUX<br>p.supply|90-260VAC/<br>DC p. supply|18-60VAC/<br>DC p.supply| |---|---|---|---|---|---|---|---|---|---|---| |||Meas.<br>inputs|-|4kV|4kV|4kV|4kV|25V|4kV|4kV| |||Relay<br>Output|4kV|-|2kV|4kV|4kV|4kV|4kV|4kV| |||Static<br>Output|4kV|2kV|-|4kV|4kV|4kV|4kV|4kV| |||Analogue<br>Output|4kV|4kV|4kV|-|4kV|4kV|4kV|4kV| |||Serial<br>Port|4kV|4kV|4kV|4kV|-|4kV|4kV|4kV| |||AUX<br>p.supply|25V|4kV|4kV|4kV|4kV|-|4kV|4kV| |||90-260VAC/<br>DC p..supply|4kV|4kV|4kV|4kV|4kV|4kV|-|-| |||18-60VAC/<br>DC p. supply|4kV|4kV|4kV|4kV|4kV|4kV|-|-| |||||||||||| **5** Specifications are subject to change without notice UDM60 DS ENG 090112 **UDM60** ## **List of selectable functions and variables** ||**Name**|**Description**|**Variables on display**| |---|---|---|---| |**F1**|Frequency meter, tachometer|Scaled value of Channel A and<br>Channel B|Channel A and channel B| |**F2**|Period meter|1/A|Channel A and function result| |**F3**|Speed difference|A-B|Channel A and function result| |**F4**|Speed error ratio|(A-B)/B*100|Channel A and function result| |**F5**|Speed ratio|A/B|Channel A and function result| |**F6**|Concentration of a liquid in a mix-<br>ture|B/(A+B)*100|Channel A and function result| |**F7**|Rotation sensing|Scaled value of Channel A and<br>relevant rotation sensing|Channel A and rotation<br>direction (on the analogue indicator)| |**F8**|Frequency meter + counter|Channel A + counter<br>channel A|Channel A and relevant counter| |**F9**|Frequency meter + counter|Channel A + counter<br>channel B|Counter relevant to channel A and counter rele-<br>vant to channel B| |**F10**|Dual counter|Counter channel A + counter<br>channel B|Counter relevant to channel A and counter rele-<br>vant to channel B| |**F11**|Total and partial counter|Counter channel A + counter<br>channel (A+B)|Counter relevant to channel A and counter rele-<br>vant to the sum of channel A and B| ## **Available modules** ## **Possible module combinations** |**Type**|**N. of**<br>**channels**|**Ordering code**| |---|---|---| |UDM60 main unit||BD 60| |Pulse signals input: 0.001Hz to<br>50kHz for DC signals|2|BQ TF1| |Pulse signals input: 0.001Hz to<br>50kHz for AC signals|2|BQ TF2| |Analogue output 0 to 20mA, 0 to<br>10VDC|1|BO AV| |Relay output|1|BO R1| |Relay output|2|BO R2| |Outputs: 2 relays + 2 open collec-<br>tors|4|BO R4| |Relay output|4|BO R5| |RS485 Serial Port|1|BR SX| |RS232 Serial Port|1|BR SY| |Power supply 18 to 60V AC/DC||BP L| |Power supply 90 to 260V AC/DC||BP H| |Power supply 10 to28V DC||BP 3| |**Basic Unit**|**Slot A**|**Slot B**|**Slot C**|**Slot D**| |---|---|---|---|---| |Measuring inputs:<br>TF1, TF2||||| |RS485 Serial port: SX||||| |RS232 Serial port: SY||||| |Analogue output: AV (*)||||| |Relay outputs and/or open<br>collector:R1, R2, R4, R5||||| |Power supply: H, L, 3||||| (*) Up to 1 module max. **6** Specifications are subject to change without notice UDM60 DS ENG 090112 **UDM60** ## **Wiring diagrams** **==> picture [503 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> BQ TF1 Fig. 1 BQ TF1 Fig. 2 BQ TF1 Fig. 3<br>ENCODER NPN/PNP NAMUR NPN and contact<br>**----- End of picture text -----**<br> **==> picture [502 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> BQ TF1 Fig. 4 BQ TF1 Fig. 5 BQ TF1 Fig. 6<br>PNP and contact NPN/PNP TTL<br>**----- End of picture text -----**<br> BQ TF1 Fig. 7 Auxiliary command **7** Specifications are subject to change without notice UDM60 DS ENG 090112 **UDM60** ## **Wiring diagrams (cont.)** **==> picture [500 x 188] intentionally omitted <==** **----- Start of picture text -----**<br> BQ TF2 Fig. 8 BQ TF2 Fig. 9 BQ TF2 Fig. 10<br>max 100VAC max 500VAC Auxiliary command<br>**----- End of picture text -----**<br> **Wiring diagrams for power supply** **BP H: power supply** **BP L: power supply** **BP 3: power supply** **==> picture [42 x 110] intentionally omitted <==** **==> picture [61 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> F1= 630mA T<br>250V 5x20mm<br>**----- End of picture text -----**<br> **==> picture [94 x 152] intentionally omitted <==** **==> picture [60 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> F1= 3.15A T<br>250V 5x20mm<br>**----- End of picture text -----**<br> **==> picture [94 x 152] intentionally omitted <==** **==> picture [60 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> F1= 3.15A T<br>250V 5x20mm<br>**----- End of picture text -----**<br> ## **Wirin dia rams of o tional modules g g p** **==> picture [41 x 110] intentionally omitted <==** **==> picture [81 x 113] intentionally omitted <==** **==> picture [81 x 111] intentionally omitted <==** **==> picture [80 x 110] intentionally omitted <==** **BO AV: analogue output (10V, 20mA DC)** **==> picture [92 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> BO R1: 1 relay output<br>**----- End of picture text -----**<br> **BO R2: 2 relay outputs** **BO R5: 4 relay outputs** **8** Specifications are subject to change without notice UDM60 DS ENG 090112 **UDM60** ## **Wiring diagrams of optional modules (cont.)** **==> picture [114 x 113] intentionally omitted <==** **==> picture [13 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Vcc<br>**----- End of picture text -----**<br> **==> picture [152 x 111] intentionally omitted <==** **BO SY:** RS232 direct connection to PC by means of COM port. RS232 has no terminalization. **BO R4: dual relay output + dual open collector output:** the load resistances (Rc) must be designed so that the close contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30VDC. VDC: power supply output Vo+: positive output (open collector transistor). GND: ground (open collector transistor). **==> picture [41 x 110] intentionally omitted <==** **==> picture [42 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> RS1,2,3...N<br>**----- End of picture text -----**<br> **==> picture [41 x 110] intentionally omitted <==** **==> picture [161 x 110] intentionally omitted <==** **==> picture [120 x 70] intentionally omitted <==** **==> picture [176 x 61] intentionally omitted <==** **----- Start of picture text -----**<br> NON terminalized network<br>Terminalized network<br>**----- End of picture text -----**<br> **BR SX: RS485 4-wire connection:** additional devices provided with RS485 port (indicated as RS1,2,3...N) are connected in parallel. The termination of the serial port is carried out only on the last instrument of the network. The serial module is provided with a jumper for the termination of the RS485 network as shown in the figure above. **Note:** particular types of cables or plants may require an external termination. For the network connections use twisted cable type AWG26. ## **Programming UDM60 by means of PC** **==> picture [148 x 209] intentionally omitted <==** **----- Start of picture text -----**<br> To UDM<br>1<br>2<br>To PC<br>1m<br>**----- End of picture text -----**<br> UDM60 is programmable by PC by means of the UdmSoft software (available on request). The user can program all parameters of UDM60 that will be subsequently uploaded and set in the instrument by the RS485 network (BR SX module) or by the RS232 connection (BR SY module). Should UDM60 be equipped without the RS485 or RS232 serial module, all programming parameters will be uploaded and set in the instrument by UdmSoft and the RS232 auxiliary serial connection (1) located on the side of the measuring input module using the special connection cable (2) available on request, as shown in the figures on the left. It is also possible to program the instrument using the dot connector (1) by means of the HyperTerminal Windows functions of a PC. Note: the RS232 auxiliary port IS NOT insulated from the measuring inputs. **9** Specifications are subject to change without notice UDM60 DS ENG 090112 **UDM60** ## **Front anel descri tion p p** ## **3. Variable type indicators** **==> picture [196 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> 6 5 4 3 2 1<br>**----- End of picture text -----**<br> ## **1. Key-pad** The programming of the configuration parameters and the display may be easily controlled by means of the 4 function keys. Display the type of the variables (A for channel A, B for channel B or F for function, min for valley value, max for peak value). ## **4. Alarm status indicators** Display any alarm condition ## **5. Analogue indicators** Display graphically the amplitude of the variables with respect to their selected minimum and maximum limits; display overload or underload conditions; display of the rotation direction. ## **6. Engineering unit** The instrument is supplied with a complete set of self-sticking labels with the main engineering units. : to enter the programming phase and to confirm the password. : - to program values; ## **Dimensions and anel cut-out p** - to select functions; - to scroll display pages. : for special functions. ## **2. Display** Instantaneous measurements: - 2 x 6 digit (max display 999999). Alphanumeric indications by means of LCD display for: - display of configuration parameters; - the measured variables. ## **En ineerin Units g g** **==> picture [40 x 194] intentionally omitted <==** **==> picture [47 x 194] intentionally omitted <==** **==> picture [242 x 402] intentionally omitted <==** **----- Start of picture text -----**<br> 11mm<br>105mm<br>48mm<br>96mm<br>45mm -0,3/+0,6<br>92mm -0,3/+0,8<br>Panel depth: 8mm.<br>**----- End of picture text -----**<br> **10** Specifications are subject to change without notice UDM60 DS ENG 090112 **UDM60** ## **Modules** ## **Input modules** **==> picture [48 x 99] intentionally omitted <==** **BQ TF1, BQ TF2** Measuring inputs **Output modules** **==> picture [47 x 99] intentionally omitted <==** **BO AV** Single analogue output 10V, 20mA DC **==> picture [242 x 62] intentionally omitted <==** **Scale 1:1** **==> picture [240 x 125] intentionally omitted <==** ## **Output modules** **==> picture [48 x 98] intentionally omitted <==** **BO R1** Single relay output **==> picture [48 x 98] intentionally omitted <==** **BO R2** Dual relay output **==> picture [48 x 98] intentionally omitted <==** **BO R4** Dual relay output + Dual open collector **==> picture [48 x 99] intentionally omitted <==** **BO R5** 4 relay outputs ## **Serial port modules** **Power supply modules** **==> picture [48 x 98] intentionally omitted <==** **==> picture [48 x 98] intentionally omitted <==** **==> picture [48 x 98] intentionally omitted <==** **==> picture [48 x 98] intentionally omitted <==** **BR SX BR SY BP H BP L** RS485 Serial port RS232 Serial port Power supply: Power supply: 60 to 260V AC/DC 18 to 60V AC/DC **==> picture [48 x 98] intentionally omitted <==** **BP 3** Power supply: 10 to 28V DC **11** Specifications are subject to change without notice UDM60 DS ENG 090112
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →