Image not available
Illustrative purposes only
ATQR30
Fuse, Cartridge, Time Delay, 30 A, 600 V, 10mm x 38mm, 0.41
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MERSEN / FERRAZ SHAWMUT
- Product type: Cartridge Fuses
- Fuse Current: 30A
- Product Range: Amp-Trap 2000 ATQR
- Fuse Size Metric: 10mm x 38mm
- Fuse Size Imperial: 0.41" x 1.5"
- Blow Characteristic: Time Delay
- Breaking Capacity Current AC: 200kA
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 10.01 € |
| Current stock | 10+ |
| Lead time | 30 days |
**AMP-TRAP 2000[®] ATQR**
**TIME DELAy/CLASS CC**
## **TAKE** _**control**_ **OF FAULT CURRENTS HEADED FOR yOUR** _**control**_ **TRANSFORMER**
ATQR small-dimension fuses feature time delay characteristics ideally suited for the high inrush currents of control transformers, solenoids, and similar inductive loads. The newest member of our Amp-trap 2000[®] family of fuses - ATQR fuses provide superior protection for the branch circuits of electrical distribution systems.
## **Features/Benefits** LC
- ➤ **Time delay** for control transformer inrush loads without nuisance opening
- ➤ **Highly current limiting** for low peak let-thru current
- ➤ **Rejection-style design** prevents replacement errors (when used with recommended fuse blocks)
- ➤ **High-visibility orange label** ensures instant recognition, and simplifies replacement
- ➤ **Metal-embossed date and catalog number** for traceability and lasting identification
- ➤ **Fiberglass body** provides dimensional stability in harsh industrial settings
- ➤ **High-grade silica filler** ensures fast arc quenching and high current limitation
## **HIGHLIGHTS:**
- ➤ Time Delay
- ➤ Best Choice for Small Transformer Protection
- ➤ Most Current-Limiting
## **APPLICATIONS:**
- ➤ Control Transformers ➤ Solenoids ➤ Inductive Loads
- ➤ Lighting, Heating & General-purpose Loads
## | **Ratings**
## **Approvals**
- ➤ **AC:** 1/10 to 30A ➤ UL Listed to 600VAC, 200kA I.R. Standard 248-4
- ➤ DC Listed to UL Standard 248
- ➤ **DC:** 1/10 to 30A300VDC, 100kA I.R.
- ➤ CSA Certified to Standard C22.2 No. 248.4
**A 16 Gross Automation (877) 268-3700 · www.ferrazshawmutsales.com · sales@grossautomation.com**
**AMP-TRAP 2000[®]**
**ATQR**
## **TIME DELAy/CLASS CC FUSES**
## Standard Fuse Ampere Ratings, Catalog Numbers
|AMPERE<br>RATING|CATALOG<br>NUMBER|AMPERE<br>RATING|CATALOG<br>NUMBER|AMPERE<br>RATING|CATALOG<br>NUMBER|AMPERE<br>RATING|CATALOG<br>NUMBER|
|---|---|---|---|---|---|---|---|
|1/10<br>1/8<br>3/16<br>2/10<br>1/4<br>3/10<br>4/10<br>1/2<br>6/10<br>3/4|ATQR1/10<br>ATQR1/8<br>ATQR3/16<br>ATQR2/10<br>ATQR1/4<br>ATQR3/10<br>ATQR4/10<br>ATQR1/2<br>ATQR6/10<br>ATQR3/4|8/10<br>1<br>1-1/8<br>1-1/4<br>1-4/10<br>1-1/2<br>1-6/10<br>1-8/10<br>2<br>2-1/4<br>2-1/2|ATQR8/10<br>ATQR1<br>ATQR1-1/8<br>ATQR1-1/4<br>ATQR1-4/10<br>ATQR1-1/2<br>ATQR1-6/10<br>ATQR1-8/10<br>ATQR2<br>ATQR2-1/4<br>ATQR2-1/2|2-8/10<br>3<br>3-2/10<br>3-1/2<br>4<br>4-1/2<br>5<br>5-6/10<br>6<br>6-1/4<br>7|ATQR2-8/10<br>ATQR3<br>ATQR3-2/10<br>ATQR3-1/2<br>ATQR4<br>ATQR4-1/2<br>ATQR5<br>ATQR5-6/10<br>ATQR6<br>ATQR6-1/4<br>ATQR7|7-1/2<br>8<br>9<br>10<br>12<br>15<br>17-1/2<br>20<br>25<br>30|ATQR7-1/2<br>ATQR8<br>ATQR9<br>ATQR10<br>ATQR12<br>ATQR15<br>ATQR17-1/2<br>ATQR20<br>ATQR25<br>ATQR30|
## Recommended ATQR Class CC Primary Fuses For Single Phase Control Transformers
## Dimensions
|TRANS|PRIMARY|PRIMARY|ATQR||TRANS|PRIMARY|PRIMARY|ATQR|
|---|---|---|---|---|---|---|---|---|
|VA|VOLTS|FLA|AMPS||VA|VOLTS|FLA|AMPS|
||600|0.04|1/10|||600|0.50|1-1/8|
||480|0.05|1/10|||480|0.63|1-1/2|
|25|240|0.10|2/10||300|240|1.25|2-1/2|
||208|0.12|1/4|||208|1.44|3|
||120|0.21|4/10|||120|2.5|5*|
||600|0.08|1/4|||600|0.83|1-1/2|
||480|0.10|1/4|||480|1.04|2|
|50|240|0.21|4/10||500|240|2.08|4*|
||208|0.24|1/2|||208|2.40|6*|
||120|0.42|6/10|||120|4.17|10*|
||600|0.13|1/4|||600|1.25|2-1/2|
||480|0.16|3/10|||480|1.56|3|
|75|240|0.31|1/2||750|240|3.13|7*|
||208|0.36|3/4|||208|3.61|8*|
||120|0.63|1|||120|6.25|15*|
||600|0.17|3/10|||600|1.67|3|
||480|0.21|4/10|||480|2.08|4*|
|100|240|0.42|6/10||1000|240|4.16|10*|
||208|0.48|1|||208|4.81|12*|
||120|0.83|1-1/2|||120|8.33|20*|
||600|0.25|1/2|||600|2.50|5*|
||480|0.31|1/2|||480|3.13|7*|
|150|240|0.63|1||1500|240|6.25|10|
||208|0.72|1-1/2|||208|7.21|20*|
||120|1.25|2-1/2|||120|12.5|25*|
||600|0.33|1/2|||600|3.33|8*|
||480|0.42|6/10||2000|480|4.17|10*|
|200|240|0.83|1-1/2|||240|8.33|20++*|
||208|0.96|2|||208|9.62|20++*|
||120|1.67|3|||600|5.00|12+*|
||600|0.42|6/10||3000|480|6.25|15+*|
||480|0.52|1-1/8|||240|12.5|30++*|
|250|240|1.04|2||5000|600|8.33|20++*|
||208|1.2|3|||480|10.4|25+*|
||120|2.08|4*||||||
## Recommended Fuse Blocks for Class CC Fuses
|Number<br>of<br>Poles|ULTRASAFE™<br>Indicating<br>Fuse<br>Holder|Screw<br>with Double<br>Quick<br>Connects|Pressure Plate<br>with Double<br>Quick<br>Connects|Copper<br>Box<br>Connector|
|---|---|---|---|---|
|ADDER<br>1<br>2<br>3|USCC1I<br>USCC2I<br>USCC3I|30310R<br>30311R<br>30312R<br>30313R|30320R<br>30321R<br>30322R<br>30323R|30350R<br>30351R<br>30352R<br>30353R|
Primary fuses - If primary FLA is less than 2 amps, fuse may be 300% max. (500% for motor control). If primary FLA exceeds 2 amps but is less than 9 amps, fuse may not exceed 167% of primary FLA unless secondary protection is used, when it may be increased to 250%. Fuse sizes shown are based on approx. 40 x FLA for .01 sec.
- Secondary protection is required for these ratings. + Fuse will withstand 30 x FLA for .01 second
- ++ Fuse will withstand 25 x FLA for .01 second
**A**
**A 17 Gross Automation (877) 268-3700 · www.ferrazshawmutsales.com · sales@grossautomation.com**
**AMP-TRAP 2000[®] TIME DELAy/CLASS CC FUSES**
**ATQR**
**==> picture [517 x 279] intentionally omitted <==**
**----- Start of picture text -----**<br>
Peak Let-Thru Current Data–ATQR1/4 to 30, 600 Volts AC Melting Time-Current Data ATQR 3/16 to 1-8/10, 600 Volts<br>on<br>—— — — A<br>100—Eanes re——— 25h 200= | 4a— A UTH\ WELNW EE i EEEEEs od<br>t+ HH~ —HH—PE—4 =) AAA “e FH<br>:: CUMNCREEat , Ti yy TCOHill<br>tt<br>_ [eK » 100 ESAS ESSEEE ==a<br>Ly || === —— so)”.. AEEate arin Seni<br>| |<br>sa SS |eaaait| | AHHHi 7eani vlVIN Ro<br>ics eal| |” :ANE\<br>|a_| aie [e] [et] itliimatilHE<br>— SEES Sasa<br>\ aK:ar CD{ | is 270 3A esee ee | Nn |<br>: Seen \\S —<br>veoheeSo eat ;<br>tt<br>200oe eet{ff ee[ri e r 151 TO 1ygA8 >|| BEANEAN CUml<br>en : Hotties st<br>s0 eee Lot :Be ee<br>200 4 LU | oe<br>anCZapneaeeeI tT 2er N\ Genet<br>th a<br>el EIN NIN<br>2 So ANAS<br>.07ofSAE=oLEEH ANSONWAKLIN TASealTET<br>Available Current in RMS Symmetrical Amperes a Le Pee FEATHERING TH<br>Current in Amperes<br>Time in Seconds<br>Maximum Instantaneous Peak Let-Thru Amperes<br>**----- End of picture text -----**<br>
**==> picture [237 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
Melting Time-Current Data ATQR 2 to 30, 600 Volts AC<br>**----- End of picture text -----**<br>
**==> picture [151 x 181] intentionally omitted <==**
**----- Start of picture text -----**<br>
;corn AN \<br>EEEanilEENNANT<br>qi ii] UTANYN \ \WE<br>aee aae,<br>1a supe bees ene<br>Til nee<br>1 TT<br>Current in Amperes<br>Time in Seconds<br>**----- End of picture text -----**<br>
**A 18 Gross Automation (877) 268-3700 · www.ferrazshawmutsales.com · sales@grossautomation.com**
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →