AT100B10
Current Transducer, AC, AT Series, Split Core, 100A, 1.5 %, 10 Vdc Voltage Output
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LEM
- Product type: Current Sensors
- Sensor Output:Voltage; Supply Voltage DC Min:-; Supply Voltage DC Max:-; Current Measuring Range DC:-; Current Measuring Range AC:0A to 100A; R; Available until stocks are exhausted
- SVHC: No SVHC (17-Jan-2022)
- Accuracy: ± 1.5%
- Accuracy %: 1.5%
- Product Range: AT Series
- Response Time: 300ms
- Primary Current: 100A
- Sensor Mounting: -
- Measured Current: AC
- Sensor Output Type: Voltage
- Supply Voltage Range: -
- Current Sensor Technology: Split Core
- Operating Temperature Max: 60°C
- Operating Temperature Min: -20°C
- Current Measuring Range AC: 0A to 100A
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 68.8 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **AC Current transducer AT-B10** ## **I = 5 .. 150 A** PN Split-core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). 0-10V DC voltage output proportional to the RMS value of the primary current. ## **Electrical data** |Primary nominal|Primary nominal|Output voltage|Output voltage|Output voltage|Type|| |---|---|---|---|---|---|---| |current rms||||||| |**I**PN|(A.t.Rms)||**V**OUT (V DC)|||| ||5|||0-10|**AT 5 B10**|| ||10|||0-10|**AT 10 B10**|| ||20|||0-10|**AT 20 B10**|| ||50|||0-10|**AT 50 B10**|| ||100|||0-10|**AT 100 B10**|| ||150|||0-10|**AT 150 B10**|| |**R**L|Load resistance||||≥ 2|MW| |**V**C|Supply voltage||||self-powered|| |**V**SZ|Output clamping voltage|||Output clamping voltage|15|V| |**Î**P|Overload capability - continuous|Overload capability - continuous|Overload capability - continuous||120|% of**I**PN| |||- 1 min|- 1 min||150|% of**I**PN| |**Performance data**||||||| |**X**|Accuracy @**I**PN,**T**A= 25°C (excluding offset)|= 25°C (excluding offset)|||< ± 1.5|% of**I**PN| |eL<br>**t**r|Linearity error<br>Response time to 90% of|||Response time to 90% of**I**PNstep|< ± 0.5<br>< 300|% of**I**PN<br>ms| |**BW**|Frequency bandwidth||Frequency bandwidth||50/60|Hz| |**General data**||||||| |**T**A|Ambient operating temperature||||- 20 .. + 60|°C| |**T**S|Ambient storage temperature||||- 20 .. + 85|°C| |**_m_**|Mass||||90|g| |**IPxx**|Protection degree||||IP40|| ## **Features** - RMS (average) output - 0-10V DC voltage output - Split-core type - Ø 16 mm sensing aperture for non-contact measurement - Terminal output - Isolated plastic case recognized according to UL 94-V0. ## **Advantages** - High isolation between primary and secondary circuits - Compact case - Cost-effective solution - Easy installation ## **Applications** - _**Automation and Supervision**_ Current measurement for process regulation by distributed PLCs or remote control (e.g. SCADA software) - _**Safety and Condition Monitoring**_ - Load monitoring for protection systems and predictive maintenance (e.g. conveyers, pumps or HVAC motors) ## **Application domain** - Energy and Automation Page 1/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 090609/6 www.lem.com ## **Current Transducer AT-B10** ## **Isolation characteristics** |**V**b|Rated isolation voltage rms1)|300|V| |---|---|---|---| ||with IEC 61010-1 standards and following conditions:||| ||- Reinforced isolation||| ||- Over voltage category CAT III||| ||- Pollution degree PD2||| ||- Heterogeneous feld||| |**V**d|Rms voltage for AC isolation test2), 50Hz, 1min.|3.5|kV| |**dCp**|Creepage distance|6|mm| |**dCl**|Clearance distance|6|mm| |**CTI**|Comparative tracking index (Group I)|600|| Notes:[1)] If insulated cable is used for the primary circuit, the isolation voltage category can be improved according to the primary cable insulation category (please refer to the cable manufacturer’s indications) - 2) between primary (completely filling the hole) and secondary. ## **Safety and warning notes** In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under www.lem.com. ## **Caution! Risk of danger** Ignoring the warnings can lead to serious injury and/or cause damage! The electric measuring transducer may only be installed and put into operation by qualified personnel that have rceived an appropriate training. The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety rquirements and in accordance with all the related systems and components manufacturers’ operating instructions. ## **Caution! Risk of electrical shock** When operating the transducer, certain parts of the module may carry hazardous live voltage (e.g. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a built-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. The transducer shall not be put into operation if the jaw opening is open (split core version) or the installation is not completed. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed. Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care. Page 2/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 090609/6 www.lem.com ## ~~**Dimensions AT-B10** (in mm. 1 mm = 0.0394 inch)~~ **==> picture [485 x 281] intentionally omitted <==** **----- Start of picture text -----**<br> Bottom view Back view<br>OQ 16<br>|_|<br>23.5<br>4 28.5 4<br>3 1.5<br>51 16<br>=<br>nf LOl h<br>| 4 tol<br>Top view<br>\ wy K S y y,<br>2-M3 terminal with cover<br>N.P<br>18<br>18<br>1.5<br>(+)<br>22 40.5<br>(-)<br>2.5<br>+<br>+<br>L K<br>**----- End of picture text -----**<br> ## **Mechanical characteristics** - General tolerance ± 1 mm - ● Primary aperture Ø 16 mm ● Fastening Cable tie ## **Remarks** - ATTENTION: contact areas (air gap) must be kept clean (particle free) to ensure proper performance ## **Connections** - Wires up to 2 mm Øp **==> picture [379 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> (AT transducer)<br>(-) (+)<br>K<br>|<br>|<br>| 2 Measure +<br>Ip | 1 Measure -<br>(-) (+)<br>Load L<br>(Controller, meter etc)<br>(Controller, meter, etc.)<br>**----- End of picture text -----**<br> LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 3/3 090609/6 www.lem.com
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →