Image not available
Illustrative purposes only
AMEPR30-4260Z
LED DRIVER, CONSTANT CURRENT, 25.2W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: AIMTEC
- Product type: AC / DC LED Power Supplies
- Pow; LED DRIVER, CONSTANT CURRENT, 25.2W; Power Supply Applications:Hazardous Locations; Output Power Max:25.2W; Output Voltage Max:42V; Output Current:600mA; LED Driver Mode:Constant
- SVHC: No SVHC (21-Jan-2025)
- Product Range: AMEPR30-Z Series
- Output Current: 600mA
- LED Driver Mode: Constant Current
- Output Power Max: 25.2W
- Input Voltage Max: 264V
- Input Voltage Min: 90V
- Output Voltage Max: 42V
- Power Supply Applications: Hazardous Locations
| Delivery and price | |
|---|---|
| Units per pack | 1000 |
| Price | 5.46 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- Series AMEPR30 Z** **up to 700mA | AC-DC LED driver** ## **FEATURES:** - Constant Current LED Driver - High Efficiency: Up to 89% - Active Power Factor Correction - Short Circuit / Open Circuit Protection - Class 2 Power Unit - Long Life, High reliability - IP20, Suitable for Indoor LED Lighting - • 3 Years Limited Warranty ## **Models** ## **Single output** |**Model**|**Max Output**<br>**Power **(W)|**Output Voltage**<br>**Range **(V)|**Output Current**<br>(mA)|**Input Voltage**<br>(VAC/Hz)|**Efficiency**<br>(%)| |---|---|---|---|---|---| |AMEPR30-4250Z|21.0|30-42|500|90-264/47-63|88| |AMEPR30-4260Z|25.2|28-42|600|90-264/47-63|89| |AMEPR30-4270Z|29.4|28-42|700|90-264/47-63|89| NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at rated output load unless otherwise specified. ## **Input Specifications** |**Parameters**|**Conditions**|**Typical **|**Maximum **|**Units**| |---|---|---|---|---| |Input Current|90 VAC,full load||0.4|Arms| |Inrush current <2ms|115 VAC,cold start||20|A| ||230 VAC,cold start||40|| |Leakage current|||0.75|mA| |Input dissipation|NoLoad||1|W| ||Output Short||2|W| |Power Factor|115VAC,full load|0.98||| ||230VAC,full load|0.95||| |InputFuse|2A/250V|||| |Start-up Time|115VAC,full load||2.5|Sec.| ||230VAC,full load||1.2|Sec.| ## **Output Specifications** |**Parameters**|**Conditions**|**Typical **|**Maximum **|**Units**| |---|---|---|---|---| |Current accuracy||±5||%| |Lineregulation|LLtoHL|±5||%| |Loadregulation|FullOutputVoltageRange|±5||%| |Ripple &Noise|||1.9|Vp-p| |Output CurrentRipple|Full load,16.7-20ms duration||1.1|Ap-p| |Current Overshoot|LLtoHL,full load at cold start||10|%Iout| |Hold-up time (min)|||0|ms| |Minimum LoadVoltage|SeeModelsTableAbove|||| ## **Isolation Specifications** |**Parameters**|**Conditions**|**Typical**|**Rated**|**Units**| |---|---|---|---|---| |TestedI/Ovoltage|||3750|VAC| |Isolation Resistance|500Vdc|>100MΩ||VAC| |Isolation Capacitance||100||pF| ## **General Specifications** |**Parameters**|**Conditions**|**Typical **|**Maximum **|**Units**| |---|---|---|---|---| |Switchingfrequency||135||KHz| |Over voltage protection|||50|VDC| |Overcurrent protection|Referto Constant Currentvs.ConstantVoltageMode curve|||| |Short circuit protection|Continuous,HiccupMode|||| |Short circuitrestart|AutoRecovery|||| Toll free: + 1 888 9 AIMTEC (924 6832) www.aimtec.com F 052.1e R4 REV: 02/20/A Tel: +1 514 620 2722 1 of 5 North America only **- Series AMEPR30 Z up to 700mA | AC-DC LED driver** |Opencircuit protection|Continuous|Continuous|Continuous|Continuous| |---|---|---|---|---| |Operating temperature||-20 to +50||oC| |Maximumcase temperature||80||oC| |Storage temperature||-30 to +85||oC| |Temperature coefficient|||0.03|% /oC| |Cooling|FreeAirConvection|||| |Humidity|||20-90|%RH| |Casematerial|Plastic|||| |IP Rating|IP20|||| |Weight|60|||g| |Dimensions (L X W+ X H)|4.33x 1.65x0.98inches110x 42 x 25mm|||| |MTBF|300,000hrs (MIL-HDBK-217Fat+25°C)|||| ## **Safety Specifications** |**Safety Specifications**<br>**Parameters**<br>~~Cd~~|**Safety Specifications**<br>**Parameters**<br>~~Cd~~|**Safety Specifications**<br>**Parameters**<br>~~Cd~~| |---|---|---| |Designed tomeet|IEC61346, UL8750, UL1310,|| |Standards|ElectromagneticInterference<br>EN550|55015 /FCCPart15, ClassB| ||Harmonic CurrentEmissions<br>EN61|1000-3-2, ClassB| ||Voltagefluctuations andflicker<br>EN61|1000-3-3| ||ElectrostaticDischargeImmunity<br>EN61|1000-4-2, 8kV Air,4kVContact,Level3, CriteriaA| ||RF,ElectromagneticFieldImmunity<br>EN61|1000-4-3,Test-RSLevel3, CriteriaA| ||Electrical FastTransient /BurstImmunity<br>EN61|1000-4-4,BurstEFT Level3, CriteriaA| ||SurgeImmunity<br>EN61|1000-4-5,Line toNeutral 2kV| ||RF, ConductedDisturbanceImmunity<br>EN61|1000-4-6. Test-CSLevel3, CriteriaA| ||Power frequencyMagneticFieldImmunity<br>EN61|1000-4-8,Test 3A/m, CriteriaA| ||Voltage dips, ShortInterruptionsImmunity<br>EN61|1000-4-11, CriteriaB| ||Electromagnetic Immunity Requirements Applies to<br>LightingEquipment<br>EN61547|EN61547| ## **Pin Definition** ## **Dimensions** **==> picture [499 x 217] intentionally omitted <==** **----- Start of picture text -----**<br> Ed Wire Connection Top View<br>Brown AC L<br>110.00<br>Blue AC N 4.33<br>Red +V Output<br>Black -V OUtput<br>14.00<br>0.55<br>42.00<br>1.65<br>14.00<br>0.55<br>ep AAA AANA AAA AA is<br>4 x Ф 2.30<br>0.09<br>Side View<br>25.00<br>0.98<br>VL)<br>110.00<br>4.33<br>**----- End of picture text -----**<br> Toll free: + 1 888 9 AIMTEC (924 6832) www.aimtec.com F 052.1e R4 REV: 02/20/A Tel: +1 514 620 2722 2 of 5 North America only **- Series AMEPR30 Z** **up to 700mA | AC-DC LED driver** ## **Application Block diagram** **==> picture [355 x 55] intentionally omitted <==** **----- Start of picture text -----**<br> AC1 LED+ > eee<br>1 [st] LED<br>AC © LED LED<br>AC2 LED-<br>**----- End of picture text -----**<br> ## **Efficiency Vs. Input Voltage & Output Load Voltage** AMEPR30-4250Z **==> picture [293 x 160] intentionally omitted <==** **----- Start of picture text -----**<br> 95.00%<br>90.00%<br>jf<br>- fF ffe t<br>a e<br>85.00%<br>P T<br>80.00%<br>115VAC<br>e e<br>75.00%<br>e e 230VAC<br>70.00%<br>TT<br>65.00%<br>24 27 30 33 36 39 42<br>Output Voltage(V)<br>Efficiency<br>**----- End of picture text -----**<br> ## AMEPR30-4260Z **==> picture [296 x 173] intentionally omitted <==** **----- Start of picture text -----**<br> 95.00%<br>90.00%<br>85.00%<br>ioc<br>80.00%<br>115VAC<br>e e<br>75.00%<br>230VAC<br>70.00%<br>PTT Pry ><br>65.00%<br>24 27 30 33 36 39 42<br>Output Voltage(V)<br>Efficiency<br>**----- End of picture text -----**<br> Toll free: + 1 888 9 AIMTEC (924 6832) North America only www.aimtec.com F 052.1e R4 REV: 02/20/A Tel: +1 514 620 2722 3 of 5 **- Series AMEPR30 Z** **up to 700mA | AC-DC LED driver** ## AMEPR30-4270Z **==> picture [298 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> 95.00%<br>90.00%<br>>??? —<br>85.00%<br>80.00% P| | ft | ft<br>115VAC<br>75.00% Po} | | | ll<br>230VAC<br>70.00% Po} | | |<br>65.00%<br>24 27 30 33 36 39 42<br>Output Voltage(V)<br>Efficiency<br>**----- End of picture text -----**<br> ## **PF vs. Input Voltage & Output Load Voltage** AMEPR30-4250Z **==> picture [301 x 154] intentionally omitted <==** **----- Start of picture text -----**<br> 1.200<br>0.900<br>0.600<br>== 115VAC<br>0.300 — 230VAC<br>0.000<br>24 27 30 33 36 39 42<br>Output Voltage(V)<br>PF<br>**----- End of picture text -----**<br> ## AMEPR30-4260Z **==> picture [298 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> 1.200<br>0.900<br>0.600<br>== 115VAC<br>—H— 230VAC<br>0.300<br>0.000<br>24 27 30 33 36 39 42<br>Output Voltage(V)<br>PF<br>**----- End of picture text -----**<br> Toll free: + 1 888 9 AIMTEC (924 6832) North America only www.aimtec.com F 052.1e R4 REV: 02/20/A Tel: +1 514 620 2722 4 of 5 **- Series AMEPR30 Z** **up to 700mA | AC-DC LED driver** ## AMEPR30-4270Z **==> picture [310 x 164] intentionally omitted <==** **----- Start of picture text -----**<br> 1.200<br>0.900<br>0.600<br>—H— 115VAC<br>= = 230VAC<br>0.300<br>0.000<br>24 27 30 33 36 39 42<br>Output Voltage(V)<br>PF<br>**----- End of picture text -----**<br> **NOTE: 1.** Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. **2.** Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. **3.** Mechanical drawings and specifications are for reference only. **4** . All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. **5.** Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. **6.** This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. **7.** Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. Toll free: + 1 888 9 AIMTEC (924 6832) www.aimtec.com F 052.1e R4 REV: 02/20/A Tel: +1 514 620 2722 5 of 5 North America only
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →