Image not available
Illustrative purposes only
AM1RD3AC07DA502
CIRCUIT BREAKER, HYDROMAGNETIC, 1P, 250V, 50A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON HEINEMANN
- Product type: Magnetic Hydraulic Circuit Breakers
- Product Range:AMR Series; Current Rating:50A; No. of Poles:1 Pole; Input Voltage VAC:250V; Interrupting Capacity:10kA; Trip Time:18s; Dielectric Strength 27C4674
- Trip Time: 18s
- No. of Poles: 1 Pole
- Product Range: AMR Series
- Current Rating: 50A
- Input Voltage VAC: 250V
- Dielectric Strength: 2.5kV
- Interrupting Capacity: 10kA
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 30.84 € |
| Current stock | 25+ |
| Lead time | 30 days |
**Frame Information** AMR Series Standard Style (AMR) Illuminated Style (AML) Rocker Style (ACR) The Heinemann AMR Series is the logical choice for applications requiring greater interrupting performance coupled with the sensitivity of hydraulic-magnetic protection. The precisely tailored time delays and ability to interrupt high currents make them ideal for critical applications. ## **UL 489 Listed** The AMR Series is UL 489 Listed and CSA certified for branch circuit applications. It is also UL 1077 recognized for use in panels where branch circuit protection is already provided. Available in a wide variety of configurations, the AMR Series is rated as high as 100 amperes at 240Vac or 80Vdc. It is the solution for demanding applications requiring up to 50,000 amperes interrupting capacity. The 50,000 amperes interrupting capacity is at 65 Vdc UL 489A, telecom applications. All UL 489 listed configurations are suitable for normal and reverse feed connection, for easy installation. ## **UL 489 Ratings** |**POLES**|**CURRENT**|**VOLTAGE**|**KA**| |---|---|---|---| |1|0.02 – 100 A|65 Vdc|50| |1,2|0.02 – 50 A|120/240 Vac|10| |3|0.02 – 30 A|240 Vac|10| |1|0.02 – 20 A|277 Vac|10| ## **Global Design** The AMR Series is designed for global applications, meeting a variety of international standards. It combines the proven high quality and reliability of the former AM Series with the spacing, dielectric and interrupt requirements of the IEC Standard 60947-2. The AMR Series carries the CE Mark, VDE and TUV approvals, and is available with metric hardware for OEMs exporting their equipment overseas. ## **Features** ## **Approvals** - Current range up to 100 A 50/60 Hz ac/125 Vdc, 60 A 400 Hz ac. - UL 1077 recognized. - UL 489 listed. - UL 489A listed for telecom applications. - 100% rated. - Plug-in, screw or stud terminals. - IEC 60947-2. - VDE. - Handles knurled for positive grip. - TUV. - Operating temperature -40°C to+85°C. ## **Handle Configurations** ## Standard Black Toggle - Available with internal auxiliary or alarm switch, relay trip function and shunt tap. For industrial and commercial applications, where economical design and construction is a concern. Order Prefix "AMR." - Shock-tested for shock in accordance with MIL-STD-202. ## Illuminated Toggle Provides indication of breaker status via the integral multicolored LED. Can be custom configured for indication of ON, OFF, Tripped or Ready status. Order Prefix "AML." - Vibration-tested in accordance with MIL-STD-202. - Dielectric strength tested in accordance with MIL-STD-202. Rocker Style - Insulation resistance of 100 megaohms minimum at 500 Vdc, per MIL-STD-202. Used where style and performance is required. The rocker style handle delivers the performance of the AMR Series with European styling. Order Prefix "ACR." - Flammability specifications of UL 94-VO case, UL 94-HB handle. - Available with UL 1500 Ignition Protected for Marine Applications. Refer to the special applications section for more information. - Direct replacement for discontinued AM and NAM/S models. ## **Standard Product Offering** The following catalog numbers can be ordered from stock. |**AMR STANDARD BLACK TOGGLE**|**AMR STANDARD BLACK TOGGLE**|**AMR STANDARD BLACK TOGGLE**||| |---|---|---|---|---| |**CURRENT**|**CURVE**|**1-POLE**|**2-POLE**|**3-POLE**| |1.00 A|2|AM1RA3AC07DA12|AM2RA3AC07DA12|AM3RA3AC07DA12| |2.50 A|2|AM1RA3AC07DA2R52|AM2RA3AC07DA2R52|AM3RA3AC07DA2R52| |5.00 A|2|AM1RA3AC07DA52|AM2RA3AC07DA52|AM3RA3AC07DA52| |7.50 A|2|AM1RA3AC07DA7R52|AM2RA3AC07DA7R52|AM3RA3AC07DA7R52| |10.0 A|2|AM1RA3AC07DA102|AM2RA3AC07DA102|AM3RA3AC07DA102| |15.0 A|2|AM1RA3AC07DA152|AM2RA3AC07DA152|AM3RA3AC07DA152| |20.0 A|2|AM1RA3AC07DA202|AM2RA3AC07DA202|AM3RA3AC07DA202| |30.0 A|2|AM1RA3AC07DA302|AM2RA3AC07DA302|AM3RA3AC07DA302| |50.0 A|2|AM1RA3AC07DA502|AM2RA3AC07DA502|AM3RA3AC07DA502| |80.0 A|2|AM1RA3AC97DA802|AM2RA3AC97DA802|AM3RA3AC97DA802| **EATON CORPORATION** Frame Information — AMR Series **20** **TYPICAL DIMENSIONS** **==> picture [513 x 516] intentionally omitted <==** **----- Start of picture text -----**<br> TYPICAL MULTI-POLE .750<br>1 TERMINAL BARRIER [19.05]<br>.555[14.10] 4A, 2.000[50.80] DIM. / im HF<br>(.138[3.51]) aa .280[7.10] 1.125[28.58] .906<br>.400[10.15]<br>.406[10.31<br>ON 2.500 2.062<br>I ; J © bei [63.50] cl [52.37] |<br>31<br>ont LINE / eo ©<br>1.940 2.740 PANEL CUTOUT<br>[ 49.28] [69.60] A1 (OPTIONAL)<br>31<br>| 0 "OFF/" STD HANDLE MARKING _/ / |<br>TYPICAL ALL CONFIGURATIONS<br>OFFO “Foran [16.66] ent Tor.) (© oe [5.28] _ | "0N/I" STD HANDLE MARKINGTYPICAL ALL CONFIGURATIONS<br>+” 656 ‘id tl | Po<br>2X .138-32 UNC-2B<br>.140[3.56] INTERNAL THD X .208<br>DEEP<br>2.860[72.64] METRIC THD M3 X 0.5 AVAILABLE<br>STANDARD HANDLE CONFIGURATION<br>AMR CATALOG NUMBERING SYSTEM<br>AM2R A 9 LC 15 DDU 52 15 1<br>Number<br>of Poles<br>Frequency<br>1 = 1-Pole<br>2 = 2-Pole A = 50/60 Hz Handle Location<br>3 = 3-Pole B = dc AC = Single-Pole Breakers Auxiliary Switch Options Current Rating<br>4 = 4-Pole C = 400 Hz LC = Multi-Pole Breakers 07 = NO-NC 4.8 Fast-on Code Current<br>5 = 5-Pole _ D = 50/60 Hz/dc =! 52 = NO-NO 2.8 Fast-on | (Amperes) | Curve<br>6 = 6-Pole 53 = NO-NC 2.8 Weld-on<br>7 = 7-Pole R02 0.02 P =Instant<br>8 = 8-Pole R25 0.25 1 = Long Delay 8X Inrush<br>Internal Circuit Type and Inrush Catalog Code Approval Code R50 0.50 2 = Medium Delay 8X Inrush<br>N/A 8X 18X 25X Internal Circuit WNU = CE 1 1 3 = Short Delay 8X Inrush<br>0 —————— — 2356715 — 9822232725 — 3938323337 — Dual RatingDuConSeries TripShunt-TapRelay TripSwitch OnlySeries Trip w/Auxiliary Terminals/Mounting Catalog CodeDNUDDUDATA = TUV/UL 1077 = UL 1077 = = UL 489 (Up to 277 Vac)None 2R557R510152025 2.557.510152025 987654S = Short Delay 25X = Medium Delay 25X Inrush = Long Delay 25X Inrush = Short Delay 18X Inrush = Medium Delay 18X Inrush = Long Delay 18X Inrush= Switch Only Inrush<br>— 16 26 — DuCon Series+Relay Imperial Metric Terminals 30 30<br>—— 9899 —— —— Mid-Trip w/AlarmMid-Trip Switch 0797 1314 1/4-20 Threads (100 A)10-32 Threads (70 A) 5060 5060<br>80 80<br>08 15 M5 Threads (70 A)<br>100 100<br>98 16 M6 Threads (100 A)<br>21 20 Plug-in 7.77 x 16.6<br>23 22 Plug-in 6.25 x 21.6<br>25 24 Plug-in 6.25 x 15.4<br>31 30 Fuse Clip<br>**----- End of picture text -----**<br> **AMR CATALOG NUMBERING SYSTEM** Select from 1 to 8 poles, and enter the number in position 3 of the catalog number. For example, an AM3L would identify a 3-pole AML breaker. On multi-pole breakers, Steps 2 and 3 can be repeated if subsequent poles are different than the first. Identification starts from left-hand side when viewing the front of the breaker. These will provide standard handle locations. For additional options, contact the Technical Resource Center. Enter the whole number current rating. For example, use code “15” for a 15 A current rating. For fractional amperages, use an “R” to designate the decimal point. For 0.10 A, enter the code “R10.” Current range up to 100 amperes 50/60 Hz, 60 amperes 400 Hz, 100 Adc. Specific data on trip curves can be found on the Web at **www.EatonElectrical.com/heinemann** . **EATON CORPORATION** Frame Information — AMR Series **21** **TYPICAL DIMENSIONS** **==> picture [516 x 224] intentionally omitted <==** **----- Start of picture text -----**<br> 1 .96 0 0.300<br>0.430 0 .75 0 Cut Out For Panel<br>0.285 2 x Holes<br>For 6-32<br>0.875<br>1.875<br>ON<br>1.940 2.500 I 1.660 1.310 1.660<br>OFF<br>0.285<br>0.750<br>0.300<br>0.475<br>nS a 0 .70 8 a Ps<br>0.180 2 x 6-32 Screws<br>ACR CATALOG NUMBERING SYSTEM<br>**----- End of picture text -----**<br> **==> picture [550 x 286] intentionally omitted <==** **----- Start of picture text -----**<br> AC2R A 9 LC 15 DDU 52 15 1<br>Number<br>of Poles<br>Frequency<br>1 = 1-Pole<br>2 = 2-Pole A = 50/60 Hz Handle Location<br>3 = 3-Pole B = dc AC = Single-Pole Breakers Auxiliary Switch Options Current Rating<br>4 = 4-Pole C = 400 Hz LC = Multi-Pole Breakers 07 = NO-NC 4.8 Fast-on Code Current<br>; \=— 5 = 5-Pole D = 50/60 Hz/dc _ | 52 = NO-NO 2.8 Fast-on (Amperes) Curve<br>6 = 6-Pole 53 = NO-NC 2.8 Fast-on<br>7 = 7-Pole R02 0.02 P =Instant<br>8 = 8-Pole R25 0.25 1 = Long Delay 8X Inrush<br>Internal Circuit Type and Inrush Catalog Code Approval Code R50 0.50 2 = Medium Delay 8X Inrush<br>N/A 8X 18X 25X Internal Circuit WNU = CE 1 1 3 = Short Delay 8X Inrush<br>0 —————— — 2356715 — 9822232725 — 3938323337 — Shunt-TapRelay TripDual RatingDuConSeries TripSwitch OnlySeries Trip w/Auxiliary Terminals/Mounting Catalog CodeDNUDDUDATA = TUV/UL 1077 = UL 1077 = = UL 489 (Up to 277 Vac)None 2R557R510152025 2.557.510152025 987654S = Short Delay 25X = Medium Delay 25X Inrush = Long Delay 25X Inrush = Short Delay 18X Inrush = Medium Delay 18X Inrush = Long Delay 18X Inrush= Switch Only Inrush<br>— 16 26 — DuCon Series+Relay Imperial Metric Terminals 30 30<br>—— 9899 —— —— Mid-Trip w/AlarmMid-Trip Switch 0797 1314 1/4-20 Threads (100 A)10-32 Threads (70 A) 5060 5060<br>80 80<br>08 15 M5 Threads (70 A)<br>100 100<br>98 16 M6 Threads (100 A)<br>21 20 Plug-in 7.77 x 16.6<br>23 22 Plug-in 6.25 x 21.6<br>25 24 Plug-in 6.25 x 15.4<br>31 30 Fuse Clip<br>**----- End of picture text -----**<br> Select from 1 to 8 poles, and enter the number in position 3 of the catalog number. For example, an AM3L would identify a 3-pole AML breaker. On multi-pole breakers, Steps 2 and 3 can be repeated if subsequent poles are different than the first. Identification starts from left-hand side when viewing the front of the breaker. These will provide standard handle locations. For additional options, contact the Technical Resource Center. Enter the whole number current rating. For example, use code “15” for a 15 A current rating. For fractional amperages, use an “R” to designate the decimal point. For 0.10 A, enter the code “R10.” Current range up to 100 amperes 50/60 Hz, 60 amperes 400 Hz, 100 Adc. Specific data on trip curves can be found on the Web at **www.EatonElectrical.com/heinemann** . **EATON CORPORATION** Frame Information — AMR Series **22** **TYPICAL DIMENSIONS** **==> picture [536 x 630] intentionally omitted <==** **----- Start of picture text -----**<br> 0.52 1-Pole Panel Cutout 0.75<br>(13.1) (19.0)<br>2.04<br>(51.7)<br>(10.3)0.41 (3.5)0.14 (7.1)0.28 (23.0)0.91<br>ON1 LINE Voltage HerePositive LEDConnect (36.8)1.45 2.06 (28.6)1.13 (23.0)0.91<br>& (52.4)<br>31º�5º C Connect<br>1.94 Negative LED<br>NONC (49.3) Black WireVoltage to 0.156Two (63.5)2.50 (52.4)2.06<br>31º�5º 1.300 DIA<br>MAX Holes<br>0.76<br>OFF0 0.66 Black Wire (19.3)<br>(16.7) LOAD 2-Pole Panel Cutout<br>Slot Positioned Left or Right,<br>0.18 Length of Black Wire Specified by Customer Per Pole Mounting Holes<br>(4.6) Else Supplied 12 Inches (304.8 mm) Long Spaced 0.750" Apart<br>3-Pole Panel Cutout<br>Slot Positioned Left, Center or<br>Right, Per Pole Mounting<br>Holes Spaced 0.750" Apart<br>AML CATALOG NUMBERING SYSTEM<br>AM3L A 2 AE 050 07 DDU 07 15 1<br>Number<br>of Poles [�] Frequency [�] Current Rating � Curve [�]<br>1 = 1-Pole<br>2 = 2-Pole A = 50/60 Hz Code Current P =Instant<br>3 = 3-Pole B = dc Approval Code (Amperes) 1 = Long Delay 8X Inrush<br>4 = 4-Pole C = 400 Hz WNU = CE R02 0.02 2 = Medium Delay 8X Inrush<br>5678 = 5-Pole = 6-Pole = 7-Pole = 8-Pole D = 50/60 Hz/dc DEAE = Multi-Pole= Single-Pole Breakers Handle Location Breakers [�] DNUDDUDATA = TUV/UL 1077 = UL 1077 = = UL 489None [�] R25R5012R5 0.250.5012.5 56347 = Medium Delay 18X Inrush = Short Delay 18X Inrush = Short Delay 8X Inrush = Long Delay 18X Inrush = Long Delay 25X Inrush<br>5 5 8 = Medium Delay 25X Inrush<br>Internal Circuit Type and Inrush Catalog Code [�] 7R5 7.5 9 = Short Delay 25X Inrush<br>10 10 S = Switch Only<br>N/A 8X 18X 25X Internal Circuit Illumination Catalog Code 15 15<br>0 —— — 23 — 98 — 3938 Series TripSwitch OnlySeries Trip w/Auxiliary Red Green One-PositionYellow Blue Position 202530 202530 Auxiliary Switch Options<br>— 5 22 32 Shunt-Tap 050 051 052 053 OFF 50 50 07 = NO-NC 4.8 Fast-on<br>— 6 23 33 Relay Trip 054 055 056 057 ON 60 60 52 = NO-NO 2.8 Fast-on<br>—— 715 2725 37 — Dual RatingDuCon 058 059 060 061 Mid Trip 80100 80100 53 = NO-NC 2.8 Fast-on<br>— 16 26 — DuCon Series+Relay Two-Position<br>— 98 — — Mid-Trip Green/ Red/ Yellow/ Blue/ Position<br>— 99 — — Mid-Trip w/Alarm Switch Red Green Blue Yellow<br>Terminals/Mounting Catalog Code<br>062 063 064 065 ON/OFF<br>Imperial Metric Terminals<br>Two-Position<br>07 13 10-32 Threads (70 A)<br>Yellow/ Green/ Red/ Yellow/ Position 97 14 1/4-20 Threads (100 A)<br>Green Yellow Yellow Red 08 15 M5 Threads (70 A)<br>066 067 068 069 ON/OFF 98 16 M6 Threads (100 A)<br>21 20 Plug-in 7.77 x 16.6<br>23 22 Plug-in 6.25 x 21.6<br>25 24 Plug-in 6.25 x 15.4<br>31 30 Fuse Clip<br>**----- End of picture text -----**<br> - Select from 1 to 8 poles, and enter the number in position 3 of the catalog number. For example, an AM3L would identify a 3-pole AML breaker. - On multi-pole breakers, Steps 2 and 3 can be repeated if subsequent poles are different than the first. Identification starts from left-hand side when viewing the front of the breaker. - These will provide standard handle locations. For additional options, contact the Technical Resource Center. - Enter the whole number current rating. For example, use code “15” for a 15 A current rating. For fractional amperages, use an “R” to designate the decimal point. For 0.10 A, enter the code “ R10.” - Specific data on trip curves can be found on the Web at **www.EatonElectrical.com/heinemann** . - Up to 277 Vac. **EATON CORPORATION** Frame Information — AMR Series **23**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →