A-AT-372
Time Delay Relay, 2 Pole, 28 V, 1 s, 448 Days, DPDT, 8 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: UNITED AUTOMATION
- Product type: Time Delay Relays - Electromechanical
- SVHC: No SVHC (20-Jun-2016)
- Time Max: 448Days
- Time Min: 1s
- Product Range: -
- Relay Mounting: Panel Mount
- Contact Current: 8A
- Relay Terminals: -
- Nom Input Voltage: -
- Timing Adjustment: DIP Switch
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 28V
- Contact Configuration: DPDT
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 34.47 € |
| Current stock | 10+ |
| Lead time | 30 days |
## ~~-~~ AT= AT ~~-~~ 372 372 Ultra Timer ULTRA TIMER Time period 1 second to 64 weeks - accurate DIL switch time settings - 4 modes of operation - wide operating voltage. - Working voltage 9.5 - 30V DC - auto selected by timer (no need to set input) - 1 second to 64 week time period. Selectable by DIL switch - crystal controlled for accurate time - “Pulse” activation after time out - option on two of the modes - Double pole relay will switch mains - contacts rated at 8 Amps - Selectable trigger and reset input polarity - Four modes of operation Setting time period - seconds, minutes, hours, days and weeks - could not be simpler - just look up the time required in the “time table” and set the DIL switch accordingly Operating Mode A - trigger applied - times out and activates the relay - if auto link is fitted relay drops out after 20 seconds and is then “waiting for next trigger” Operating Mode B - trigger applied – relay activates for time period then drops out. It is then ready for the next trigger. however if the door is open after the 3 minutes the relay will activate - if auto link is fitted relay drops out after 20 seconds and is then “waiting for next trigger” Operating Mode C - once applied the trigger must remain for the duration of the time setting to activate the relay. An example of this would be monitoring a fire door. If the door is opened the timer starts (say it has been set for 3 minutes) if the door closes before the three minutes nothing happens, Activation - trigger and reset input polarity is set by jumper links. ## Specification ## Input Levels for Trigger or Reset ## LOW: Less than 220 ohms to ground OR an input of less than 0.8 volts ## HIGH: Greater than 4700 ohms to ground OR an input of greater than 4 volts Maximum input voltage 30V Minimum input voltage -4V Peak current available from either pin, 5mA ## Output Levels ## Double pole contacts AC: Maximum switching voltage 250 volts, maximum current 8 Amps (non inductive load) DC: Maximum switching voltage 30 volts, maximum current 5 Amps (non inductive load) ## Environmental Operating Conditions Temperature range -10°C to +60°C Maximum humidity 80% non condensing ## Supply Voltage Between 9.5 to 30V, automatically selected by the timer, no need to set jumpers or cut links. ## Unit Supplied In strong cardboard carton with 4 sticky fixers ## Dimensions 77.9 X 47mm ## Packing Weight 80 grams Minimum switching level 5V @ 10mA
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →