Image not available
Illustrative purposes only
84140631N
Solid State Relay, 50 A, 510 VAC, Panel Mount, Screw, Random Turn On
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET
- Product type:
- SVHC: Lead (21-Jan-2025)
- Load Current: 50A
- Product Range: Dual GN Series
- Relay Mounting: Panel Mount
- Switching Mode: Random Turn On
- Relay Terminals: Screw
- Control Voltage Max: 30VDC
- Control Voltage Min: 10VDC
- Contact Configuration: -
- Operating Voltage Max: 510VAC
- Operating Voltage Min: 24VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 83.14 € |
| Current stock | 10+ |
| Lead time | 30 days |
**|** 04/2023 ## › **GN2 Series** ## **Classic Solid State Relays** Panel Mount – Dual channel - › **25 and 50 Amps** - › **2 independent SSRs in one package** - › **Fast-on 25 A version available** - › **Input with Fast-on or 4 pins connector** - › **Zero-Voltage Turn-On and Instantaneous (Random) Turn-On** - › **cRUus, CE and UKCA Recognized** **==> picture [482 x 380] intentionally omitted <==** **----- Start of picture text -----**<br> Fast-on Screw Connection<br>(Marking label 26532004<br>sold separately)<br>Product Selection - Zero Cross (Resistive Loads)<br>Rated Load Current 25 A Fast-on 25 A 50 A<br>Output Voltage 24-280 V a 24-280 V a 48-660 V a<br>Control Voltage<br>4-32 V c 84140800N 84140603N<br>10-30 V c 84140013N 84140613N<br>Product Selection- Instantaneous (Random) (Inductive Loads)<br>Rated Load Current 50 A<br>Output Voltage 24-510 V a<br>Control Voltage<br>10-30 V c 84140631N<br>Part number system<br>Zero Cross Switching Version & Random Switching Version<br>Phases/Channels Control Voltage Generation<br>8414: Dual Channel 0: 4-32 V c | Zero Cross N: New Generation<br>1: 10-30 V c | Zero Cross<br>3: 10-30 V c | Instantaneous<br>84140 0 1 0 N<br>Current Connectivity<br>0: 25 A 0: Fast-on | Zero Cross<br>6: 50 A 1: Screws | Instantaneous<br>8: 25 A | Fast-on 3: Screws | Zero Cross<br>**----- End of picture text -----**<br> Do you need an adapted or customized solution? Contact us on **www.crouzet.com** ## **Description:** Crouzet Solid State Relays are designed to be used in almost any application, offering very long life expectancy and are easy to install, easy to use, robust and multipurpose. For more information about Crouzet’s Solid State relays, please visit **www.crouzet.com** . **|** WWW.CROUZET.COM **| 2** **|** GN2 Series **|** 04/2023 ## **Accessories** **==> picture [495 x 626] intentionally omitted <==** **----- Start of picture text -----**<br> Type Description Part-Number<br>Heatsink 0.9 °C/W Thermal Resistance 26532752N<br>Heatsink 1.1 °C/W Thermal Resistance 26532753N<br>Heatsink 1.2 °C/W Thermal Resistance 26532754N<br>Heatsink 1.75 °C/W Thermal Resistance 26532755N<br>Heatsink 2.2 °C/W Thermal Resistance 26532756N<br>Adapter DIN Rail 26532764N<br>Thermal Pad Pre-cut Thermal Pad 26532720N<br>Thermal Pad Self-Adhesive Thermal Pad 26532722N<br>Screws Screw Mounting Kit 26532001<br>Thermal Grease Thermal Grease for Heatsink mounting 26532003<br>ID TAG Marking label 16 x 8 x 1 mm 26532004<br>4-Pin connector 4 pole 90° & 270° 26532005<br>4-Pin connector 4 pole 270° 26532006<br>Output Characteristics [(1)]<br>Description 25 A 50 A<br>Operating Voltage (47-440 Hz) [Vrms] 24-280 24-510 48-660<br>Switching Type Zero Cross Instantaneous Zero Cross<br>Maximum Load Current [Arms] [(4)] 2 x 25 @ 40 °C 2 x 50 @ 40 °C<br>Minimum Load Current [mArms] 5<br>Transient Overvoltage [Vpeak] 600 (480) 1200 (950) 1200<br>Maximum Surge Current (50/60 Hz (Typ.@ 50 Hz), 1 Cycle) 250/260 (min) 700/_ (min) 1100/_ (min)<br>[Apeak] 340 (typ) 750 (typ) 1200 (typ)<br>1 second surge current (Apk. Ta=25 °C) 50/60 Hz 95 230 347<br>Maximum I²t for Fusing (50/60Hz 1/2 cycle) [A² sec] 340 (min) 2450 (min) 6000 (min)<br>600 (typ) 2800 (typ) 7200 (typ)<br>Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] 500<br>Maximum Off-State Leakage Current @ Rated Voltage 1<br>[mArms]<br>Maximum On-State Voltage Drop @ Rated Current [Vrms] 1.25 1.38 1.23<br>Thermal Resistance Junction to Case (Rjc) [°C/W] 1.7 0.3 0.4 0.3<br>Minimum Heatsink for rated Current @ 40 °C [°C/W] [(4)] 0.5 37 0.37 0.48<br>Minimum Power Factor (at Maximum load) 0.8 0.45 0.8<br>Input Characteristics [(1)]<br>Description 4-32 V c 10-30 V c<br>Control Voltage Range 4-32 V c 10-30 V c<br>Minimum Turn-On Voltage 4 10<br>Must Turn-Off Voltage 1 2<br>Maximum Reverse Voltage -32 V c<br>Minimum Input Current [mA] 10 6<br>Maximum Input Current [mA] 14 24<br>Nominal Input Impedance [Ohms] Current limited 1200<br>Maximum Turn-On Time ½ Cycle ½ Cycle [(2)]<br>Maximum Turn-Off Time ½ Cycle<br>**----- End of picture text -----**<br> **|** WWW.CROUZET.COM **| 3** **|** GN2 Series **|** 04/2023 ## **General Characteristics** |**Description**|25 A Fast-on|25 A|50 A| |---|---|---|---| |Dielectric Strength (Input-Output) (Vrms)|4000||| |Dielectric Strength Output Case (Vrms)|2500||4000| |Minimum Insulation Resistance (@ 500 Vc)|109Ω||| |Maximum Capacitance, Input/Output|0.8 pF||| |Ambient Operating Temperature Range|-40 to 80 °C||| |Ambient Storage Temperature Range|-40 to 100 °C||| |Housing Material|UL94 V-0||| |Terminals|Screw type and connector with screw type<br>Fast-on (0.25'' / 6.3 mm for output terminals and 0.19'' / 4. 8 mm for control<br>terminals)||| |Output Screw Torque (in-lb/Nm)|18-26/2-3||| |SSR Mounting Screw Torque (in-lb/Nm)|11-16/1.2-1.8||| |Humidity (IEC60068-2-78)|85% non-condensing||85 % non-condensing| |Input Status Indicator|LED green||| |Weight (g)|80||| |MTBF (Mean Time Between Failure) @40 °C (years)|45(3)||| ## **General Notes** (1) All parameters at 25 °C unless otherwise - (2) For Instantaneous (Random) (84140631N) = <0.1 - (3) For 84140800N, MTBF= 35 - (4) Heatsink required, see derating curves ## **Diagrams** ## **Wiring** ## GN2 & GN2 Fast-on **==> picture [392 x 286] intentionally omitted <==** **----- Start of picture text -----**<br> GN2 L1 N or L2 L1 L2 L3 L1 L2 L3 L1 L2 L3<br>L1 L2 L1 L2 L1 L2 L1 L2<br>InputA + [-] +- BInput InputA + [-] +- BInput InputA + [-] +- InputB InputA + [-] +- InputB<br>T1 T2 T1 wteec T2 T1 erase) T2 T1 T2<br>LOAD LOAD LOAD LOAD LOAD LOAD LOAD<br>A B A B C A B<br>L O A D C<br>1 2 3 4<br>GN2 Fast-on L1 N or L2 L1 L2 L3 L1 L2 L3 L1 L2 L3<br>L<br>O<br>A<br>D<br>C<br>Heo L1 T1 L2 T2 L O A D B Wei L1 T1 L2 T2 L O A D B Hoi L1 T1 L2 T2 fmoin L1 T1 L2 T2 L O A D B<br>L O A D A L O A D A L O A D A<br>Input A- + Input B- + Input A- + Input B- + Input A- + Input B- + L O A D C Input A- + Input B- +<br>o m fa im f ies ie<br>®@ 1 ® 2 ® 3 ®@ 4<br>B Single-phase wiring<br>C Star connection (balanced low voltage loads without neutral)<br>D Delta connection (high voltage loads)<br>E Open Delta connection (high voltage loads)<br>**----- End of picture text -----**<br> It's recommended to use external overvoltage protection (Varistor / TVS Diode) and short-circuit protection (fuse / circuit breaker), if they are not already integrated **|** WWW.CROUZET.COM **| 4** **|** GN2 Series **|** 04/2023 **==> picture [173 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> Connectors<br>Part Number 26532005 Part Number 26532006<br>**----- End of picture text -----**<br> ## Recommended Wire Size |**TERMINALS**|**WIRE SIZE**|**WIRE SIZE**|**Terminal Screw**<br>**Torque (N.m)**| |---|---|---|---| ||**SOLID**|**STRANDED**|| |**Input**|26..12 AWG (0.2..2.5 mm²)|26..12 AWG (0.2..2.5 mm²)|0.4 - 0.5| |**Output**|8..16 AWG (1.5..10 mm²)<br>2 x 8..16 AWG (1.5..10 mm²)|10..16 AWG (1.5..6 mm²)<br>2 x 10..16 AWG (1.5..6 mm²)|2 - 3| Flat head screw 0.6 X 3.5mm DIN5264 ## **Diagrams** ## **Equivalent Circuit Block** GN2 Series 4-32 V c control Triac - 24-280 V a - Zero Cross - 84140800N ## Input current vs Input Voltage Standard Regulated DC inputs **==> picture [248 x 307] intentionally omitted <==** **----- Start of picture text -----**<br> Current Limiter<br>A1 - 1 L<br>PUT OUTP<br>A2 + 2 T<br>Current Limiter<br>B1 - 3 L<br>PUT OUTP<br>B2 + 4 T<br>GN2 Series 10-30 V c control Triac - 24-280 V a -<br>Zero Cross - 84140013N<br>A2 - 1 L1<br>PUT OUTP<br>A1 + 2 T1<br>B2 - 3 L2<br>PUT OUTP<br>B1 + 4 T2<br>**----- End of picture text -----**<br> **==> picture [248 x 285] intentionally omitted <==** **----- Start of picture text -----**<br> 14<br>12<br>10<br>8<br>6<br>4<br>2<br>0<br>0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32<br>Input Voltage (V)<br>Input current vs Input Voltage<br>Standard Regulated DC inputs<br>30<br>25<br>20<br>15<br>10<br>5<br>0<br>0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30<br>Input Voltage (V)<br>Input Current (mA)<br>Input Current (mA)<br>**----- End of picture text -----**<br> **|** WWW.CROUZET.COM **| 5** **|** GN2 Series **|** 04/2023 **==> picture [248 x 494] intentionally omitted <==** **----- Start of picture text -----**<br> GN2 Series 4-32 V c control Thyristors- 48-660 V a -<br> Zero Cross - 84140603N<br>Current Limiter<br>A2 - 1 L1<br>PUT OUTP<br>A1 + 2 T1<br>Current Limiter<br>B2 - 3 L2<br>PUT OUTP<br>B1 + 4 T2<br>GN2 Series 10-30 V c control Thyristors - 24-510 V a -<br>Instantaneous - 84140631N<br>2 - 1 L1<br>PUT OUTP<br>1 + 2 T1<br>2 - 3 L2<br>PUT OUTP<br>1 + 4 T2<br>GN2 Series 10-30 V c control Thyristors - 48-660 V a -<br>Zero Cross - 84140613N<br>A2 - 1 L1<br>PUT OUTP<br>A1 + 2 T1<br>B2 - 3 L2<br>PUT OUTP<br>B1 + 4 T2<br>**----- End of picture text -----**<br> **==> picture [105 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Input current vs Input Voltage<br>Standard Regulated DC inputs<br>**----- End of picture text -----**<br> **==> picture [248 x 448] intentionally omitted <==** **----- Start of picture text -----**<br> 14<br>12<br>10<br>8<br>6<br>4<br>2<br>0<br>0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32<br>Input Voltage (V)<br>Input current vs Input Voltage<br>Standard Regulated DC inputs<br>30<br>25<br>20<br>15<br>10<br>5<br>0<br>0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30<br>Input Voltage (V)<br>Input current vs Input Voltage<br>Standard Regulated DC inputs<br>30<br>25<br>20<br>15<br>10<br>5<br>0<br>0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30<br>Input Voltage (V)<br>Input Current (mA)<br>Input Current (mA)<br>Input Current (mA)<br>**----- End of picture text -----**<br> **|** WWW.CROUZET.COM **| 6** **|** GN2 Series **|** 04/2023 ## **Diagrams** ## **Dimensions (mm)** **==> picture [194 x 205] intentionally omitted <==** **----- Start of picture text -----**<br> GN2<br>3<br>44,8<br>28<br>Ø 4,7 2 M5<br>4,7<br>2 M5<br>28<br>1<br> ±<br>1<br>29,1 ±<br>16,3<br>- 0,8<br>47,6<br>59,4<br>0+<br>**----- End of picture text -----**<br> **==> picture [46 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> GN2 Fast-on<br>**----- End of picture text -----**<br> **==> picture [200 x 195] intentionally omitted <==** **----- Start of picture text -----**<br> 3<br>44,8<br>35,06 ±1<br>23,8 ±1 7,62 ±1<br>Ø 4,7<br>22,6 ±1 7,62 ±1 4,7<br>35,06 ±1<br>1<br> ± 1<br>19,5 18 ±<br>6,354x 58 47,6 1±<br>4,8 40,6<br>4x<br>**----- End of picture text -----**<br> ## **Curves** ## **Surge Current Information** ## GN2 - 25 A - 84140013N / 84140800N ## GN2 - 50 A - 84140603N / 84140631N **==> picture [490 x 295] intentionally omitted <==** **----- Start of picture text -----**<br> 300 800<br>700<br>250<br>600<br>200<br>500<br>150 400<br>300<br>100<br>200<br>50<br>100<br>0 0<br>0,01 0,1 1 10 0,01 0,1 1 10<br>T (s) T (s)<br>No Repetitive Surge Current / Tj initial = 25 °C No Repetitive Surge Current / Tj initial = 25 °C<br>Repetitive Surge Current / Tj initial = 121 °C Repetitive Surge Current / Tj initial = 70 °C<br>GN2 - 50 A - 84140613N<br>1200<br>1100<br>1000<br>900<br>800<br>700<br>600<br>500<br>400<br>300<br>200<br>100<br>0<br>0,01 0,1 1 10<br>T (s)<br>No Repetitive Surge Current / Tj initial = 25 °C<br>Repetitive Surge Current / Tj initial = 70 °C<br>Itsm ( Apeak) Itsm (Apeak)<br>Itsm (Apeak)<br>**----- End of picture text -----**<br> **|** WWW.CROUZET.COM **| 7** **|** GN2 Series **|** 04/2023 ## **Curves** ## **Thermal Derating Curves** **==> picture [137 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> GN2 - 25 A - 84140013N / 84140800N -<br>25 Amps per channel<br>**----- End of picture text -----**<br> **==> picture [130 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> 60<br>50<br>40 a<br>SSSA<br>30<br>20 —-<br>10<br>SSS<br>0 ee<br>0,0 20,0 40,0 60,0 80,0<br>Ambient Temperature (°C)<br>5 °C/W 2 °C/W 0,5 °C/W 0,25 °C/W 1 °C/W<br>Accessories<br>Heatsink<br>Total Load Current (Amps)<br>**----- End of picture text -----**<br> **==> picture [179 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> GN2 - 50 A - 84140603N / 84140631N / 84140613 -<br>50 Amps per channel<br>120<br>100<br>80 a<br>SN<br>60<br>40 SSNS<br>20<br>SN<br>0 —<br>0,0 20,0 40,0 60,0 80,0<br>Ambient Temperature (°C)<br>5 °C/W 2 °C/W 0,5 °C/W 0,25 °C/W 1 °C/W<br>Total Load Current (Amps)<br>**----- End of picture text -----**<br> 0.9 °C/W Thermal Resistance - 26532752N 1.1 °C/W Thermal Resistance - 26532753N 1.2 °C/W Thermal Resistance - 26532754N 1.75 °C/W Thermal Resistance - 26532755N 2.2 °C/W Thermal Resistance - 26532756N **==> picture [46 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Accessories<br>Thermal Pad<br>**----- End of picture text -----**<br> **==> picture [73 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Pre-cut - 26532720N<br>**----- End of picture text -----**<br> **==> picture [232 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Self-Adhesive - 26532722N ID TAG - 26532004<br>**----- End of picture text -----**<br> **|** WWW.CROUZET.COM **| 8** **|** GN2 Series **|** 04/2023 ## **Accessories Others** **==> picture [406 x 249] intentionally omitted <==** **----- Start of picture text -----**<br> Screw Mounting Kit - 26532001 Thermal Grease for Heatsink mounting - DIN Rail - 26532764N<br>26532003<br>& Ye &@ \<br>Connectors<br>| <><br>Part Number 26532005 Part Number 26532006<br>**----- End of picture text -----**<br> ## **Standards & Electromagnetic Compatibility Specfification** EN60950-1: Meets the requirements of sections 1.5: 1.7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Certified according to EN 62314: 2006 IEC 61000-4-2: Electrostatic Discharge immunity test 8kV air discharge Criterion A Level 3 IEC 61000-4-4: Electrical fast transient/burst immunity test 1kV Line to Line Criterion B Level 3 IEC 61000-4-5: Surge immunity test 1kV Line to Line Criterion B Level 3 **==> picture [139 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> Standards<br>UL508<br>cmw;<br>US<br>**----- End of picture text -----**<br> ## **Warning:** The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual commitment. Crouzet and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →