- Manufacturer: PILZ
- Product type: Safety Relays
- Coil Voltage:-; Contact Configuration:3PST-NO; Product Range:PNOZ X4 Series; Relay Mounting:DIN Rail; Contact Current:8A; Relay Terminals:Screw; Contact Voltage AC Nom:-; Contact Volta
- SVHC: To Be Advised
- IP Rating: IP20, IP40, IP54
- Coil Voltage: 24VDC
- Product Range: -
- Relay Mounting: DIN Rail
- Contact Current: 8A
- Relay Terminals: Screw
- Contact Material: Silver Tin Oxide
- Contact Configuration: 3PST-NO, SPST-NC
- Contact Voltage AC Nom: 240V
- Contact Voltage DC Nom: 24V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 244.66 € |
| Current stock | 10+ |
| Lead time | 30 days |
Emergency Stop Relays, Safety Gate Monitors
## **Category 4, EN 954-1** PNOZ X4
EMERGENCY STOP switchgear and safety gate monitor according to VDE 0113-1, 11/98, EN 60204-1, 12/97 and IEC 60204-1, 11/98
## **Features**
- either monitored, unmonitored or automatic start possible
- 1-channel or 2-channel wiring with or without shorts across contacts detection
## **Approvals**
**PNOZ X4** ● ● ●
**==> picture [298 x 351] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Technical data|PNOZ X4|
|Electrical data|
|Power supply|AC: 24, 110, 115, 120, 230, 240 V|
|DC: 24 V|
|Tolerance|85 ... 110 %|
|CO|Power consumption|Approx. 4.5 VA/2.5 W|
|Voltage and current at input,|24 V DC, 40 mA|
|start and feedback loop|
|Output contacts|3 safety contacts (NO)|
|1 auxiliary contact (NC)|
|Switching capability according to|
|EN 60947-4-1, 02/01|AC1:|240 V/8 A/2000 VA|
|DC1:|24 V/8 A/200 W|
|EN 60947-5-1, 11/97 (DC13:6 cycles/min)|AC15:|230 V/5 A; DC13: 24 V/7 A|
|Contact protection according to|10 A quick or 6 A slow|
|EN 60947-5-1, 08/00|
|Times|
|Pickup delay|monitored start: max. 100 ms|
|auto./man. start: max. 0,35 s|
|Delay-on de-energisation|at EMERGENCY STOP: max. 50 ms|
|at mains off: max. 0,5 s|
|Recovery time|approx. 1 s|
|Simultaneity channel 1 and 2|
|Power failure buffer|approx. 25 ms|
|Mechanical data|
|Max. cross-section of outer conductor|2 x 1.5 mm|[2]|oder 1 x 2.5 mm|[2]|
|single wire or multi-wire with|
|end ferrule|
|Dimensions (H x W x D)|87 x 45 x 121 mm|
|Weight|AC: 360 g, DC: 265 g|
**----- End of picture text -----**<br>
## **Operating modes**
## **Description**
- Single channel mode
- 45 mm P-97 housing, on standard rail, snap-on
- Dual channel mode without shorts across contacts detection
- Relay outputs, positive-guided: – 3 safety contacts (NO)
- Dual channel mode with shorts across contacts detection
- 1 auxiliary contact (NC)
- Connection possibilities for – EMERGENCY STOP switch – Safety gate limit switch
- – Start switch
- Automatic start
- Manual start without monitoring
- Manual start with monitoring
- LEDs for switching status Channel 1 and 2 and power supply
- Contact multiplication and Contact amplification possible by external contactors
NSG-D-2-128-12/01
Emergency Stop Relays, Safety Gate Monitors
## Category 4, EN 954-1 PNOZ X4
## **Schematic interior diagram**
● Example 5 Dual-channel safety gate control without shorts across contacts detection with automatic start
**==> picture [431 x 385] intentionally omitted <==**
**----- Start of picture text -----**<br>
Feedback-Rückführ- StartStart- Sicherheits-Safety Auxiliary detection with automatic start<br>UB loopkreis loopkreis EingangskreisInput loop kontaktecontacts Hilfskontaktcontact<br>A1 A2 S52 Y2 Y1 S34 S33 S11 S11 S12 S12 13 23 33 41 S11 S21 S33 Y36<br>—--@-—-@—-—@--—-—@- -@-Q@—@--@-Q@-—@--—- -Q—-—. fa r@----@-@--O,<br>AC<br>DC S12<br>K1 S11<br>ChannelKanal<br>Kg Start loopStartkreis 11 MTR | HDT)]<br>| ChannelKanal<br> 22<br>| K2 | S52 S22 S34 Y37<br>| | ● Example 6<br>Only on AC ig nur am g- S21 S22 @-—.6- Y36 Y37 6. 14 24 34 o—— 42<br>deviceAC-Gerät Input loopEingangskreis monitored start<br>S11 S11 S33<br>ft 1G 9--%-e;<br>S1<br>Example 1 ● Example 3 S12S21S21 S3<br>Single-channel EMERGENCY STOP Dual-channel EMERGENCY STOP S2<br>wiring with automatic start wiring without shorts across<br>contacts detection with monitored : --- ---<br>start S22 S52 S34<br>S11 S12 S21 S33 Y36 S11 S11 S21 S33 Y36<br>● Example 7<br>S1 S1<br>S3 shorts across contacts detection by<br>BWS, with monitored start<br>S11 S11 S21 S33<br>S12 S52 S22 S34 Y37 S12 S52 S22 S34 Y37 BWS 24 V DC<br>S3<br>Example 2 ● Example 4<br>Single-channel EMERGENCY STOP Single-channel safety gate control<br>with unmonitored start<br>**----- End of picture text -----**<br>
● Example 6 Dual-channel safety gate control with shorts across contacts detection and monitored start
**==> picture [64 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
S11 S11 S33 Y36<br>1G 9--%-e;<br>S1<br>S12S21S21 S3<br>S2<br>--- --- _@:<br>S22 S52 S34 Y37<br>**----- End of picture text -----**<br>
## **External wiring**
● Example 1 ● Example 3 Single-channel EMERGENCY STOP Dual-channel EMERGENCY STOP wiring with automatic start wiring without shorts across contacts detection with monitored start
● Example 7 Dual channel light barrier control with shorts across contacts detection by BWS, with monitored start
**==> picture [98 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
S11 S11 S21 S33 Y36<br>BWS 24 V DC<br>S3<br>S12 S52 S22 S34 Y37<br>**----- End of picture text -----**<br>
**==> picture [55 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
● Example 2<br>**----- End of picture text -----**<br>
Single-channel EMERGENCY STOP wiring with unmonitored start
**==> picture [255 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
S11 S12 S21 S33 Y36 S11 S21 S12 S33 Y36<br>S1<br>S1<br>S3 S3<br>S12 S52 S22 S34 Y37 S12 S22 S52 S34 Y37<br>**----- End of picture text -----**<br>
## – Legend
**==> picture [140 x 85] intentionally omitted <==**
**----- Start of picture text -----**<br>
S1/S2: EMERGENCY STOP or safety<br>gate switch<br>S3: Start switch<br>actuated element<br>gate not closed<br>(x gate closed<br>**----- End of picture text -----**<br>
NSG-D-2-128-12/01
## Emergency Stop Relays, Safety Gate Monitors
## **Category 4, EN 954-1** PNOZ X4
## ● Contact multiplication
The output contacts can be amplified or multiplied by external contactors with positive-guided contacts if necessary.
**==> picture [92 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
1L1<br>K6<br>K5<br>Y1 Y2 13<br>|<br>|<br>|<br>Lo<br>14<br>K5 K6<br>1L2<br>**----- End of picture text -----**<br>
NSG-D-2-128-12/01
Emergency Stop Relays, Safety Gate Monitors **Category 4, EN 954-1** PNOZ X4 **General Technical Data Unless stated otherwise in the technical details for the specific unit Electrical Data** Frequency Range AC 50 ... 60 Hz Residual Ripple DC 160 % Contact Material AgSnO2 Continuous Duty 100 % **Environmental Data** EMC EN 50081-1, 01/92, EN 50082-2, 03/00 Vibration in accordance with Frequency: 10 ... 55 Hz, EN 60068-2-6, 01/00 Amplitude: 0.35 mm Climatic Suitability DIN IEC 60068-2-3, 12/86 Airgap Creepage DIN VDE 0110 part 1, 04/97 Ambient Temperature -10 ... +55 °C Storage Temperature -40 ... +85 °C **Mechanical Data** Torque Setting on Connection Terminals 0.6 Nm (screws) Mounting Position Any Housing Material Thermoplast Noryl SE 100 Protection Mounting: IP 54 Housing: IP 40 Terminal Range: IP 20 The units were tested in accordance with the relevant standards current at the time of development. **Order References Type UB Order No.** PNOZ X4 24 V DC 774 730 PNOZ X4 24 V AC 774 731 PNOZ X4 110 V AC 774 734 PNOZ X4 115 V AC 774 735 PNOZ X4 120 V AC 774 736 PNOZ X4 230 V AC 774 738 PNOZ X4 240 V AC 774 739 ~~L~~ NSG-D-2-128-12/01
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →