Image not available
Illustrative purposes only
70-059-60/1.6A
Fuse, Cartridge, Fast Acting, 1.6 A, 250 V, 6.3mm x 32mm, 1/4" x 1-1/4", 189000
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIBA
- Product type: Cartridge Fuses
- Blow Characteristic:Fast Acting; Fuse Current:1.6A; Voltage Rating VAC:250V; Fuse Size Metric:6.3mm x 32mm; Fuse Size Imperial:1/4" x 1-1/4"; Product Range:189000 Series; Breaking Capa
- SVHC: No SVHC (17-Jan-2022)
- Fuse Current: 1.6A
- Product Range: 189000
- Fuse Size Metric: 6.3mm x 32mm
- Fuse Size Imperial: 1/4" x 1-1/4"
- Voltage Rating VAC: 250V
- Blow Characteristic: Fast Acting
- Breaking Capacity Current AC: 35A
| Delivery and price | |
|---|---|
| Units per pack | 2000 |
| Price | 0.355 € |
| Current stock | 10+ |
| Lead time | 30 days |
G-Sicherungseinsätze / Miniature Fuse-Links ## Europa Part Ref: Europa Part Ref:o 70-059-60 ## Type **189000** Zeit/Strom-Kennlinien Time-Current Characteristics **==> picture [134 x 246] intentionally omitted <==** **----- Start of picture text -----**<br> 10 4<br>SSSaa 189000 50mA - 100mA125mA - 10A<br>|<br>10 3 Lf}ff} ttt ttf<br>——_—<—_——_===--——<br>es<br>ee<br>a ee<br>10 2 Lf} [fff] tt ttf<br>=aeses eeee ee=== |——<br>10 1 ee<br>ke |<br>an ee CO ee<br>10 0 Se<br>a a en<br>a<br>a ee sO |<br>10 -1 ee See<br>SS eee eee<br>SS DA<br>eeCOTEA NTR EE<br>10 -2 EA SNR 4<br>SN<br>poNN<br>eS ee<br>poNIN<br>10 -3<br>1 Lo SN 4 5 15<br>I<br>Irat.<br>2 6 7 8 9 10<br>t<br>sec.<br>Type<br>3<br>**----- End of picture text -----**<br> Abmessungen Dimensions ## Aufbau / Construction Galrsoh / ralgt ssub e Kontaktkappen / end caps ducrhcishrt / gitansparent Messing, vernickelt / brass, nickel-plated ## Verpackung / Packing 100 Stück / pieces (10 x 10) 1000 Stück Industrieverpackung / pieces industrial packs (IP) ## Schmelzzeitgrenzwerte / Fusing time limits |Bemessungsstrom<br>Rated Current<br>2 In<br>min.|Bemessungsstrom<br>Rated Current<br>2 In<br>min.|Bemessungsstrom<br>Rated Current<br>2 In<br>min.|2,75 In<br>max.<br>min.|2,75 In<br>max.<br>min.||max.|max.|4 In|min.||max.|10 In<br>min.|10 In<br>min.||max.| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |50 mA - 100 mA|50 mA - 100 mA|-|20 s|2 ms||200 ms||1 ms||30 ms|||-||5 ms| |125 mA - 10 A||-|20 s|20 ms||1,5 s||8 ms||400 ms|||-||80 ms| ||||||||||||||||| |(IEC 60127-2/4)|||**6,3 x 32 mm**<br>(0,25 x 1,25“)|||250 V|||||F<br>fl ink<br>quick acting||||| ||||||||||||||||| |Bemessungs-<br>strom<br>Rated Current<br>50 mA<br>ae|Bemessungs-<br>Ausschaltvermögen<br>Rated Breaking<br>Capacity<br>35 A @ AC 250 V<br>ee|Spannungsfall<br>Voltage Drop<br>mV<br>9600<br>es||Leistungsabgabe<br>Power Dissipa-<br>tion (@ 1,15 In)<br>W<br>0,7<br> es|||Schmelzintegral<br>I²tsValue<br>A²s<br>0,0003<br> es||||||Approbationen<br>Approvals||| |63 mA|35 A @ AC 250 V||6000|||0,5|||0,0005||||||| |80 mA<br>100 mA<br>125 mA<br>——|35 A @ AC 250 V<br>35 A @ AC 250 V<br>35 A @ AC 250 V||5000<br>4500<br>4000|||0,6<br>0,7<br>0,7|||0,001<br>0,0014<br>0,0034||||||| |160 mA<br>—|35 A @ AC 250 V||3500|||0,8|||0,007||||||| |200 mA|35 A @ AC 250 V||3000|||0,9|||0,013||||||| |250 mA|35 A @ AC 250 V||3000|||1,0|||0,022||||||| |315 mA|35 A @ AC 250 V||2500|||1,1|||0,054||||||| |400 mA|35 A @ AC 250 V||2200|||1,2|||0,11||||||| |500 mA|35 A @ AC 250 V||1900|||1,3|||0,21||||||| |630 mA|35 A @ AC 250 V||400|||0,4|||0,26||||||| |800 mA|35 A @ AC 250 V||350|||0,4|||0,57||||||| |1 A|35 A @ AC 250 V||300|||0,5||||1,1|||||| |1,25 A|35 A @ AC 250 V||300|||0,6||||2|||||| |1,6 A|35 A @ AC 250 V||300|||0,7||||3,3|||||| |2 A|35 A @ AC 250 V||250|||0,8||||6,2|||||| |2,5 A|35 A @ AC 250 V||220|||0,9||||13|||||| |3,15 A|35 A @ AC 250 V||200|||1,1||||24|||||| |4 A|40 A @ AC 250 V||200|||1,3||||40|||||| |5 A|50 A @ AC 250 V||180|||1,4||||80|||||| |6,3 A|63 A @ AC 250 V||170|||1,6||||150|||||| |8 A|80 A @ AC 250 V||160|||2||||240|||||| |10 A|100 A @ AC 250 V||150|||2,3||||500|||||| |12,5 A|125 A @ AC 250 V||140|||2,5||||650|||||| |16 A|160 A @ AC 250 V||130|||2,8|||1250||||||| |20 A|200 A @ AC 250 V||130|||4,0|||1600||||||| Bei Verwendung dieser G-Sicherungseinsätze ab 6,3 A ist auf ausreichende Wärmeabfuhr zu achten. When using this type from 6.3 A up, consideration should be given to heat dissipation.
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →