Image not available
Illustrative purposes only
6320-2500-0000
Panel Mount Timer, 20 VAC, 300 VAC, 0.1 s, 9999999.9 h, 22.6 mm, 45.5 mm
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TRUMETER
- Product type: Hour Meters
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 9999999.9h
- Time Min: 0.1s
- Product Range: -
- Panel Cutout Width: 45.5mm
- Supply Voltage Max: 300VAC
- Supply Voltage Min: 20VAC
- Panel Cutout Height: 22.6mm
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 32.29 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Model 6320** ## **Electronic LCD Hour Meter** **The Model 63 Electronic Hour Meter with 8 LCD digits bring together features, including optional programmable alert or preset capability, to control a significant process.** The front utilizes a high-contrast, reflective, 8-digit LCD with 0.32 inch [8mm] digits and seven icons, while at the back end Dry Contact, Low Voltage DC, and High Voltage DC and AC Inputs are available. The Model 63 family is designed with a rugged plastic housing that is qualified to NEMA 4/4X when properly installed using the gasket supplied. In addition, the unit is compliant with CE EMC standards to EN61326:2001 for industrial applications, recognized by UL for U.S. and Canadian safety standards, and it is compliant to European RoHS and WEEE standards. ## **Key Features** - Reflective LCD Display with 8 large (8mm) digits - Choice of hour meter types: - Hour Meter - Minutes Meter - Choice of I/O compliment that includes: - Switch Input (No voltage) - Low DC Voltage (3-30VDC) <2mA - High Voltage (20-300VAC or 10-300VDC) <2mA - Control Inputs - External Electronic Reset - Optional Front Panel Programming for flexible RediAlert or Preset functionality - Optional Redi-Alert Functions: - 3 Redi-Alerts available with Front Panel Programming option - NEMA 4/4X, 12, and IP66 rated - EMC Compliant to EN61326:2001 for industrial environments - CE compliant, UL and cUL recognized - European WEEE & RoHS Compliant ## **Capabilities** ## **Hour Meter Operation** These counting methods are factory set. _Hour Meter:_ The Hour Meter displays hours in a resolution of hours and tenths. A front panel programmable unit or a factory programmed unit can be programmed to display a resolution of 0.01 hours. _Minute Meter:_ The Minute Meter displays minutes to a displayed resolution of 0.1 minutes. ## **I/O Functions** The I/O functions can be mixed and matched to maximize the functionality of the Hour Meter. There are three types of inputs that the Hour Meter can accept. The interfaces for each are factory set. The inputs can be: - Switch – open circuit or switch closure - Low Voltage DC – Low input is less than 1VDC and High Input is 3 – 30VDC. - High Voltage DC or AC – Low is less than 3VDC or 3VAC. A High Input is either 10 – 300VDC or 20-300VAC. For the Switch and Low Voltage DC Hour Meters, there are six screw terminals for all of the I/O. For the High Voltage Hour Meters, there are four screw terminals for the I/O. The combinations of the I/O and power supply are factory set. Enable Inputs: The enable inputs are those inputs that enable the accumulation of time. Remote Reset: When the remote reset is at a high level, the Hour Meter will reset. Front Panel Reset Enable: The Hour Meter will reset when the Front Panel Reset Enable is at a high level, and the Front Panel Reset Switch is pressed. The Hour Meter will not reset when the Front Panel Reset Enable is at a low level and the Front Panel Reset Switch is pressed. ## **Optional Preset Function** Each Hour Meter may be placed in a preset operating mode. This mode can be programmed through the front panel for those units that have the front panel programming option. It may also be factory programmed. IT IS NOT RECOMMENDED THAT THE PRESET FUNCTION BE USED AT THE SAME TIME THAT ALERTS ARE ENABLED. The preset Hour Meters can be set up for either automatic reset or external (front panel or remote) reset. ## **Optional Alert Functions** The Model 63 Hour Meter can be programmed to operate as a maintenance device in which alerts notify the user of certain maintenance actions to be taken after accumulation of a predefined time. When the accumulated time equals the predefined alert value, an icon is illuminated on the display. When the alert is reset, the icon is turned off, but the accumulated time is not reset. There are two types of alerts. The first is a break-in alert. A break-in alert only occurs once at the start of unit operation. The second type of alert is recurring. A recurring alert occurs continuously at a predefined period. When tied to a break-in alert, the recurring alert will not begin its count until the break-in alert has occurred. The intervals for the recurring alert can be performed as start-to-start or end-to-start. A start-to-start interval count starts when the last alert is turned on. The end-to-start interval count starts when the last alert is turned off. The Model 63 Hour Meter can support three alerts using front panel programming and four alerts when factory programmed. IT IS NOT RECOMMEDED THAT THE PRESET FUNCTION BE USED AT THE SAME TIME THAT ALERTS ARE ENABLED. In both cases, Alert #1 is a break-in alert that is tied to Alert #2, which is recurring. Alert #3 is recurring, and Alert #4 can be factory set as either break-in or recurring. If Alert #4 is break-in, then it is tied to Alert #3. The Model 63 Hour Meter can be programmed to be latched or kept on for a predetermined time. When latched, an external reset is required to turn off the alert. ## **Front Panel** The liquid crystal display is reflective with dark characters on a light background. There are 8 digits on the display. The standard display contains seven icons which can be assigned as desired to either alerts or a preset. Model 63 Hour Meters with the front panel programming option are capable of being programmed for either alerts or the preset function. There are two front panel switches. To begin programming, the two switches are pressed simultaneously. The programming menu must be completed in its entirety to return to normal operation. The switch functions are described as follows: SEL: During normal operation, the displayed Hour Meters will be swapped when the SEL switch is pressed and released. During programming, this switch is used to select options. RST: During normal operation, the RST switch is used for front panel reset. During programming, the RST switch is used to enter an option. ## **Resets** Unless using alerts, a reset returns the display to zero. If using alerts, the reset turns an alert off. There are three different reset configurations available: _Non-Reset:_ The Hour Meter can never be reset. A non-reset unit also has no front panel programming option. _Remote Reset:_ A model with Remote reset has a dedicated terminal for performing the reset function. The unit resets when the remote reset signal is at a high level. When the reset signal is at a low level, accumulating time can occur. _Manual Reset:_ Manual reset occurs when the RST switch on the front of the Hour Meter is pressed. Accumulating time resumes upon release of the RST switch. ## **Dimensions** **Display** Figures: 8 LCD digits 0.32” [8mm] high **Environmental** Annunciators: A choice of 7 Icons 0.08” [2mm] high **Temp.** -4˚F to + 140˚F [-20˚C to +60˚C] (Storage & **Reset** Remote, manual & non-reset. Manual reset enable is Operating) available on some models **Humidity** 0 to 95% RH, non-condensing **Inputs** Switch (no voltage) **Vibration** Operating: 10 to 55 Hz, 0.01” [0.25mm] double _DC Voltage:_ amplitude Absolute voltage range: -0.5 VDC, minimum to Non-operating 10 to 55 Hz, 0.03” [0.75mm] double 30.0VDC, maximum amplitude VIH: 3.0 VDC, maximum **Shock** Operating: 10G’s VIL: 1.0 VDC, minimum **Non-operating** 30G’s _High Voltage AC/DC:_ **Dielectric** 1000 VAC 50/60Hz for 1 minute Absolute Maximum voltage: 300VAC/VDC **Accuracy** 100% (provided signal meets stated parameters) VIH: 10VDC/20 VAC, max. **EMC Compliance** EN61326:1997 with A1: 1998 & A2:2001 for industrial VIL: 3VDC/3 VAC, minimum environments **Power** Internally powered models: Self powered (+10 yrs **Enclosure** NEMA 4/4X, 12, & IP66 compliance (from the front) lithium battery) when properly mounted using the optional gasket **Battery Life** 10 years (battery life reduced to 5 years for temps above 100˚F/37.8˚C) **Approvals** CE compliant, UL & cUL recognized **Mounting** Panel with clip **Env. Compliance** Compliant to the European WEEE & RoHS **Terminations** Terminal block **Weight** 2 oz. [57g] ## Notes 1. When interfacing the Model 63 with a Solid State Relay or AC Sensor, the leakage current needs to be considered. 2. The Absolute Voltage Range and the Absolute Maximum Voltage are the voltages at which operation beyond the specified limits may result in damage to the unit. ## **Product Dimensions** ## **Available Icons** **==> picture [210 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> |} | 1.76 [44.7] | LB<br>1.86 [47.3]<br>1.50 [38.0]<br>2.00 [50.8]<br>1.31 [33.4]<br>-_ bu Ee<br>.87 [22.1] .97 [24.7]<br>1.10 [27.9] .31 [8.0]<br>.02 [0.5]<br>.48 [12.1] .16 [4.0]<br>Panel Cutout: 1.79” [45.5mm] x 0.89” [22.6mm]<br>Recommended Panel Thickness: 0.125” [3.1mm]<br>**----- End of picture text -----**<br> **==> picture [161 x 80] intentionally omitted <==** **----- Start of picture text -----**<br> SERVICE OIL<br>CHANGE OIL FILTER<br>AIR FILTER MUFFLER<br>><br>LAMP<br>**----- End of picture text -----**<br> ## **Part Numbers** |6320-0000-0000|HOUR METER DRY CONTACT INPUT REMOTE RESET|5003-013| |---|---|---| |6320-0500-0000|HOUR METER DRY CONTACT INPUT PROGRAMMING/FPRESET inc REDI-ALERTS|5003-013| |6320-1000-0000|HOUR METER 3-30 VDC INPUT REMOTE RESET|5003-013| |6320-1500-0000|HOUR METER 3-30 VDC INPUT PROGRAMMING/FPRESET inc REDI-ALERTS|5003-013| |6320-2000-0000|HOUR METER 10-300/20-300 VDC/VAC INPUT REMOTE RESET|5003-013| |6320-2500-0000|HOUR METER 10-300/20-300 VDC/VAC INPUT PROGRAMMING/FPRESET|5003-013| |720-6300|HOUR METER 85-500VAC INPUT NON-RESET 6” LEADS SPECIAL HIGH VOLTAGE IN A 3-HOLE ROUND STEEL CASE|| ## **FOR FRONT PANEL PROGRAMMABLE RESET AND REDI-ALERT OPTIONS PLEASE CONTACT US.** **Trumeter (Europe) Trumeter (The Americas)** Pilot Mill 6601 Lyons Rd, Suite H-7, Alfred Street Coconut Creek, Florida Bury, FL 33073, BL9 9EF USA Tel: +44 161 674 0960 Tel: +1 954 725 6699 Email: sales.uk@trumeter.com Email: sales.usa@trumeter.com **Innovative Design Technologies Sdn. Bhd** Lot 5881, Lorong Iks Bukit Minyak 1 Taman Perindustrian Iks, 14000 Bukit Tengah Penang, Malaysia Web: www.idtworld.com Tel: + 604 5015700 Email: sales.my@idtworld.com **www.trumeter.com** 6320-DS.v.3.2 07/2021
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →