Image not available
Illustrative purposes only
534422
INSULATED BRAIDED CONDUCTOR, CKT BREAKER
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: NVENT ERIFLEX
- Product type: Circuit Breaker Accessories
- For Use With:Molded Case Circuit Breakers; Accessory Type:Insulated Braided Conductor; Product Range:- 32AK2778
- For Use With: Molded Case Circuit Breakers
- Product Range: -
- Accessory Type: Insulated Braided Conductor
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 585.97 € |
| Current stock | 10+ |
| Lead time | 30 days |
IBSB ADVANCED INSULATED BRAIDED CONDUCTOR, 350 A, 0.94" X 0.2" X 12.99" ## CATALOG NUMBER ## **IBSBADV100-330** IBS/IBSB Advanced Insulated Braided Conductor, Halogen Free is the ideal ready-to-install flexible wire replacement solution that is specifically designed for connections to all molded case circuit breakers, including the most compact breakers on the market. IBS/IBSB Advanced connects to the front access terminals of the breakers without any additional accessories, such as angular connectors, spreaders, ring terminal connectors or extenders. IBS/IBSB Advanced is available in cross sections of 25 to 240 mm² (49.34 to 273.65 kcmil), lengths from 230 to 1,030 mm (9.06" to 40.55"), and 80 to 700 A. Manufactured in an ISO 9001 certified automated facility, IBS/IBSB Advanced is formed by weaving high-quality electrolytic copper wire to form a durable low voltage connector with maximum flexibility which allows for more compact power connections to circuit breakers. The IBS/IBSB Advanced allows users to reduce the total size and weight of the installation, improving both design flexibility and assembly aesthetics. The unique manufacturing process of integral pre-punched palms make IBS/IBSB Advanced ready to connect out of the box. There are no lugs to purchase or install, making connections simpler and faster and eliminates faulty connections due to vibration or fatigue. IBS/IBSB Advanced is compatible with all major brand molded case circuit breakers. The advanced technology insulation is a high-resistance low smoke, halogen-free and flame retardant thermoplastic. IBS/IBSB Advanced does not generate corrosive gases and produces a relatively low smoke opacity in accordance with IEC 61034-2 and UL 2885. The low smoke characteristic improves visibility conditions for people to be able to easily locate the emergency exit and also allows rescue workers to better assess an emergency situation. IBS/IBSB Advanced means greater safety for individuals, less damage for your electrical equipment and less environmental impact. The halogen–free feature enables a reduction in the quantity of toxic smoke. IBS/IBSB Advanced does not contain any halogens, according to IEC 60754-1 and UL 2885, minimizing toxicity and making it the ideal product for use in enclosed spaces such as data centers, rail, and public facilities such as hospitals and schools. This also facilitates the use of IBS/IBSB Advanced in specific applications such as submarines, switchboards and other enclosed environments that require a low emissions solution. In addition to the above features, IBS/IBSB Advanced is compliant with the UL 94-V0 testing standard and glow wire test 960 °C. The flame retardant portion of the test illustrates the self-extinguish feature. This superior feature of IBS/IBSB Advanced is also shown by the Limiting Oxygen Index (LOI) at 30%. In case of fire, IBS/IBSB Advanced generates a limited quantity of smoke that is less damaging to your electrical equipment. ## CERTIFICATIONS ## FEATURES Suitable for all main molded case circuit breakers Resistant to vibration, improving reliability and performance Insulated by high-resistance, halogen free, flame retardant and low smoke material Tinned copper provides superior corrosion resistance Improves assembly flexibility and aesthetics Quick and easy installation No additional cutting, stripping, crimping and punching needed Integral palm without lugs or terminals reduces material and assembly weight Conforms to NF EN 45545 obtaining an HL3 classification for chapters R22 and R23 DNV GL® and Bureau Veritas certified for marine and offshore applications Small wire diameter provides maximum flexibility Dramatically smaller and more flexible than comparable cable based on ampacity Better power density than cable with lower skin effect ratio Reduces total installation cost RoHS compliant Tinned copper allows for copper or aluminum conductor connections On request, can be manufactured with other colors (typically with Orange sleeve for battery connection) 2 PRODUCT ATTRIBUTES Article Number: 534422 Typical Application Current Rating: 350 A Peak Short Circuit Current (Ipk): 70 kA Finish: Tinned Material: Copper;Thermoplastic Elastomer Dielectric Strength: 20 kV/mm Flammability Rating: UL® 94V-0 Halogen Free Rating: UL® 2885;IEC® 60754-1;IEC® 62821-1 Low Smoke Rating: IEC® 61034-2;ISO 5659-2;UL® 2885 UV Resistance Rating: UL® 2556;UL® 854;IEC® 60 364: AN3 Level Insulation Elongation: 500 % Insulation Thickness: 0.070" Max Working Voltage, IEC/UL 758: 1,000 VAC;1,500 VDC Max Working Voltage, UL 67: 600 VAC/DC Working Temperature: -58 to 239 °F Wire Diameter: 0.006" Certification Details: UL® 67;UL® 758 Complies With: IEC® 60439.1;IEC® 60695-2-11 (Glow Wire Test 960 °C);IEC® 61439.1;IEC® 61439.1 Class II Cross Section: 197.350 kcmil Conductor Width: 0.94" Conductor Thickness: 0.20" Length: 12.990" A: 0.350" B: 0.430" C: 1.220" D: 0.510" Hole Size 1: 0.330" Hole Size 2: 0.410" Unit Weight: 0.860 lb ## ADDITIONAL PRODUCT DETAILS ∆T = Temperature of conductors – Internal temperature of panel. This table indicates the temperature rise produced by chosen current in the given section. This calculation does not take into account the heat dissipation from the switch gear. IBSB Advanced Insulated Braided Conductor with a cross section of 240 mm² (473.65 kcmil) is constructed of red copper strands with tinned palms. 3 Distance between supports must not exceed 630 mm (17.8") according to IEC 61439-1. |**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**| |---|---|---|---|---|---|---|---|---|---| |**Cross Section**<br>**(mm²/kcmil)**|**ΔT 30°**<br>**C (A)**|**ΔT 40°**<br>**C (A)**|**ΔT 45°**<br>**C (A)**|**ΔT 50°**<br>**C (A)**|**ΔT 55°**<br>**C (A)**|**ΔT 60°**<br>**C (A)**|**ΔT 70°**<br>**C (A)**|**2 Bar Current**<br>**Coefficient**|**3 Bar Current**<br>**Coefficient**| |25/49.34|116|134|142|150|157|164|177|1.6|2| |50/98.68|213|246|260|274|288|301|325|1.6|2| |70/138.15|226|261|277|291|306|319|345|1.6|2| |100/197.35|298|344|365|385|404|422|456|1.6|2| |120/236.82|363|419|444|468|491|513|554|1.6|2| |185/365.1|416|480|509|537|563|588|635|1.6|2| |240/473.65|556|642|681|718|753|786|849|1.6|2| |**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**|**Maximum Ampacity Ratings**| |---|---|---|---|---|---|---|---|---|---| |**Cross Section**<br>**(mm²/kcmil)**|**ΔT 30°**<br>**C (A)**|**ΔT 40°**<br>**C (A)**|**ΔT 45°**<br>**C (A)**|**ΔT 50°**<br>**C (A)**|**ΔT 55°**<br>**C (A)**|**ΔT 60°**<br>**C (A)**|**ΔT 70°**<br>**C (A)**|**2 Bar Current**<br>**Coefficient**|**3 Bar Current**<br>**Coefficient**| |25/49.34 (IBSB)|116|134|142|150|157|164|177|1.6|2| |25/49.34 (IBS)|137|158|167|177|185|193|209|1.6|2| |50/98.68|213|246|260|274|288|301|325|1.6|2| |70/138.15|226|261|277|291|306|319|345|1.6|2| |100/197.35|298|344|365|385|404|422|456|1.6|2| |120/236.82|363|419|444|468|491|513|554|1.6|2| |185/365.1|416|480|509|537|563|588|635|1.6|2| |240/473.65|556|642|681|718|753|786|849|1.6|2| 4 |**Circuit**<br>**Breaker**<br>**Current**<br>**Rating**|**125/160 A**|**125/160 A**|**250 A**|**250 A**|**300 A**|**350 A**|**400 A**|**500 A**| |---|---|---|---|---|---|---|---|---| |**Part Number**|**IBSBADV25x**|**IBSADV25x**|**IBSBADV50x**|**IBSADV50x**|**IBSBADV70x**|**IBSBADV100x**|**IBSBADV120x**|**IBSBADV185x**| |Schneider<br>Electric®<br>Compact®<br>(IEC)|NSA NG 125|NSX 100<br>NSX 160|NSX 250|NSX 250|NSX 400|NSX 400|NSX 400|NSX 630| |Square D®<br>PowerPact®<br>(UL)|H-Frame|J-Frame|J-Frame|J-Frame|L-Frame|L-Frame|L-Frame|-| |ABB® Tmax®<br>(IEC)|T1 T2 XT1<br>XT2|-|T3 XT3 XT4|T3 XT3 XT4|T4|T4|T5|T5| |ABB® Tmax®<br>(UL)|T1 T2 XT1<br>XT2|T3|T4 XT3 XT4|T4|T5|T5|T5|-| |GE® Record<br>Plus®<br>(IEC/UL)|FD 160|FD 160|FE 250|FE 250|FG 400|FG 400|FG 400|FG 630| |Siemens®<br>Sentron®<br>(IEC/UL)|VL160X 3VL1<br>VL160 3VL2|-|VL250 3VL3|VL250 3VL3|VL400 3VL4|VL400 3VL4|VL400 3VL4|-| |Moeller®<br>xEnergy®<br>(IEC)|NZM1|-|NZM2|NZM2|NZM3|NZM3|NZM3|NZM3| |Cutler<br>Hammer®<br>Series G (UL)|EG Frame|JG Frame|JG Frame|JG Frame|LG Frame|LG Frame|LG Frame|LG Frame| |Legrand®<br>(IEC)|DPX 160<br>DPX3 160|-|DPX 250<br>DPX3 250|DPX 250<br>DPX3 250|DPX 630|DPX 630|DPX 630|DPX 630| |Hager® (IEC)|h3 160|-|h3 250|h3 250|h3 630|h3 630|-|-| |Rockwell/Allen<br>Bradley (UL)|G-Frame H-<br>Frame|-|I-Frame J-<br>Frame|I-Frame J-<br>Frame|I-Frame J-<br>Frame|-|K-Frame|K-Frame| |Mitsubishi<br>Electric (IEC)|-|NF125<br>NF160<br>DSN125<br>DSN160|NF250<br>DSN250|NF250<br>DSN250|-|NF400<br>DSN400|-|-| |OEZ (IEC)|BC160N|-|BD250N<br>BD250S|-|BH630B<br>BH630S|BH630B<br>BH630S|BH630B<br>BH630S|BH630B<br>BH630S| ## DIAGRAMS 5 ## WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. North America Europe Europe APAC +1.800.753.9221 Netherlands: Germany: Shanghai: Option 1 – Customer Care +31 800-0200135 800 1890272 + 86 21 2412 1618/19 Option 2 – Technical Support France: Other Countries: Sydney: +33 800 901 793 +31 13 5835404 +61 2 9751 8500 **==> picture [91 x 60] intentionally omitted <==** Our powerful portfolio of brands: nVent.com **CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER** © 2023 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice. **6**
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →