Image not available
Illustrative purposes only
501290125000
Safety Relay, 12 VDC, DPDT, 50 Series, Through Hole, 8 A, Solder
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Safety Relays
- Coil Voltage:12VDC; Contact Configuration:DPDT; Product Range:50 Series; Relay Mounting:Through Hole; Contact Current:8A; Relay Terminals:Solder; Contact Voltage AC Nom:250V; Contact V
- SVHC: No SVHC (04-Feb-2026)
- IP Rating: -
- Coil Voltage: 12VDC
- Product Range: 50 Series
- Relay Mounting: Through Hole
- Contact Current: 8A
- Relay Terminals: Solder
- Contact Material: Silver Nickel Gold
- Contact Configuration: DPDT
- Contact Voltage AC Nom: 250V
- Contact Voltage DC Nom: -
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 9.87 € |
| Current stock | 500+ |
| Lead time | 30 days |
A) : PCB Relay with forcibly «7rap |t **o** l guided contacts 8 A Hoists and cranes Escalators Medical and dentistry a Hospitals . Carousel warehouses Elevators and lifts Disabled lift Woodprocessing machines **50 SЕRIES** FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. **50 SERIES** **C** **PCB Relay with forcibly guided contacts according to EN 61810-3 (previously EN 50205) Type B 2 CO contacts*** **==> picture [171 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 50.12…1000 50.12…5000<br>**----- End of picture text -----**<br> **Type 50.12…1000** - 2 pole 8 A - Contact AgNi - **Type 50.12…5000** = _ i - 2 pole 8 A - Contact AgNi + Au - • High physical separation between adjacent • For medium duty switching, • For safety applications contacts suggested for DC loads • Gold plate contacts for low - • Cadmium Free contact materialsCadmium Free contact materials • 2 pole 8 A level switching capability - Cadmium Free contact materialsCadmium Free contact materials - 5 mm pinning • 5 mm pinning • PCB mounting • PCB mounting - 8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts - Flux proof: RT II - According to EN 61810-3 only 1 NO and 1 NC (11-14 and 21-22 or 11-12 and 21-24) shall be used as forcibly guided contacts. _For UL ratings see:_ |_“General technical information” page_V|_“General technical information” page_V|Copper side view||Copper side view| |---|---|---|---|---| |For outline drawing see page 7||||| |**Contact specification**<br>Contact configuration||2 CO (DPDT)||2 CO (DPDT)| |Rated current/Maximumpeak current<br>A||8/15||8/15| |Rated voltage/<br>Maximum switchingvoltage|V AC|250/400||250/400| |Rated load AC1|VA|2000||2000| |Rated load AC15 (230 V AC)|VA|500||500| |Singlephase motor rating(230 V AC)<br>kW||0.37||0.37| |BreakingcapacityDC1: 30/110/220 V<br>A||8/0.65/0.2||8/0.65/0.2| |Minimum switchingload|mW (V/mA)|500 (10/10)||50 (5/5)| |Standard contact material<br>**Coil specification**<br>Nominal voltage (UN)|V AC (50/60 Hz)|AgNi<br>—||AgNi + Au<br>—| ||V DC|5 - 6 - 12 - 24 - 48 - 60 - 110 - 125|5 - 6 - 12 - 24 - 48 - 60 - 110 - 125|| |Ratedpower AC/DC|VA (50 Hz)/W|—/0.7||—/0.7| |Operating range|AC (50 Hz)|—||—| ||DC|(0.75…1.2)UN||(0.75…1.2)UN| |Holdingvoltage|AC/DC|—/0.4 UN||—/0.4 UN| |Must drop-out voltage<br>**Technical data**|AC/DC|—/0.1 UN||—/0.1 UN| |Mechanical life AC/DC|cycles|—/10 · 106||—/10 · 106| |Electrical life at rated load AC1|cycles|100 · 103||100 · 103| |Operate/release time|ms|10/4||10/4| |Insulation between coil||||| |and contacts(1.2/50µs)<br>Dielectric strength<br>between open contacts<br>Ambient temperature range<br>Environmentalprotection<br>**Approvals**(according to type)|kV<br>V AC<br>°C|6(8 mm)<br>1500<br>–40…+70<br>RT II<br>FAL®A|A|6(8 mm)<br>1500<br>–40…+70<br>RT II<br>CAXys| **3** **50 SERIES** **C** **PCB Relay with forcibly guided contacts according to EN 61810 (previously EN 50205) Type A** |**PCB Relay with forcibly guided contacts**<br>**according to EN 61810 (previously EN 50205)**<br>**Type A**<br>**Type 50.14…4220/4310**<br>- 4 pole 8 A (2 NO + 2 NC) or (3 NO +1 NC)<br>- Contact AgSnO2<br>**Type 50.16…5420/5510**<br>- 6 pole 8 A (4 NO + 2 NC) or (5 NO +1 NC)<br>- Contact AgSnO2+ Au<br>•High physical separation between adjacent<br>contacts<br>•Cadmium Free contact materials<br>•DC coil 800 mW<br>•8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts<br>•PCB mounting<br>•Wash tight: RT III<br>_For ULratings see:_<br>_“General technical information” page_V<br>For outline drawing see page 7<br>**Contact specification**<br>Contact configuration|**50.14**<br>•For safety applications<br>•4 pole 8 A<br>•PCB mounting|**50.14**<br>•For safety applications<br>•4 pole 8 A<br>•PCB mounting|**50.16**<br>•For safety applications<br>•6 pole 8 A<br>•PCB mounting| |---|---|---|---| ||Ø1.3<br>18.05<br>3.4<br>5.0 6.5 5.0<br>7.6<br>Copper side view<br>2 NO +2 NC, 3 NO + 1 NC<br>3 NO + 1 NC<br>2 NO + 2 NC||Copper side view<br>4 NO +2 NC, 5 NO + 1 NC<br>4 NO + 2 NC<br>5 NO + 1 NC| |Rated current/Maximumpeak current<br>A|8/15<br>~~ee~~||8/15<br>~~ee~~| |Rated voltage/<br>Maximum switchingvoltage<br>V AC|250/400||250/400| |Rated load AC1<br>VA|2000<br>~~ee~~||2000<br>~~ee~~| |Rated load AC15 (230 V AC)<br>VA|700<br>~~pf~~||1100<br>~~pf~~| |Singlephase motor rating(230 V AC)<br>kW|0.37<br>~~ee~~||0.37<br>~~ee~~| |BreakingcapacityDC1: 30/110/220 V<br>A|8/0.6/0.2<br>~~ee~~||8/0.6/0.2<br>~~ee~~| |Minimum switchingload<br>mW (V/mA)|50 (5/10)<br>~~ee~~||50 (5/10)<br>~~ee~~| |Standard contact material<br>**Coil specification**<br>Nominal voltage (UN)<br>V AC (50/60 Hz)<br>V DC|AgSnO2<br>—||AgSnO2+ Au<br>—| ||12 - 24 - 48 - 110<br>~~pf~~||12 - 24 - 48 - 110<br>~~pf~~| |Ratedpower AC/DC<br>VA (50 Hz)/W|—/0.8<br>~~ee~~||—/0.8<br>~~ee~~| |Operating range<br>AC (50 Hz)<br>DC|—<br>~~ee~~||—<br>~~ee~~| ||(0.75…1.2)UN<br>~~en~~||(0.75…1.2)UN<br>~~en~~| |Holdingvoltage<br>AC/DC|—/0.4 UN<br>~~es~~||—/0.4 UN<br>~~es~~| |Must drop-out voltage<br>AC/DC<br>**Technical data**<br>Mechanical life AC/DC<br>cycles|—/0.1 UN<br>—/10 · 106||—/0.1 UN<br>—/10 · 106| |Electrical life at rated load AC1<br>cycles|100 · 103<br>~~en~~||100 · 103<br>~~en~~| |Operate/release time<br>ms|10/4<br>~~ee~~||10/4<br>~~ee~~| |Insulation between coil<br>and contacts(1.2/50µs)<br>kV|6(8 mm)||6(8 mm)| |Dielectric strength<br>between open contacts<br>V AC|1500||1500| |Ambient temperature range<br>°C|–40…+70<br>~~ee~~||–40…+70<br>~~ee~~| |Environmentalprotection|RT III<br>~~ee~~||RT III<br>~~ee~~| |**Approvals**(according to type)|EAL|EAL A cANs|| **4** **50 SERIES** **C** ## **Ordering information** Example: 50 series forcibly guided contacts, 2 CO (DPDT) 8 A contacts, 24 V DC coil. ## **A B C D 5 0 . 1 2 . 9 . 0 2 4 . 5 0 0 0 A: Contact material D: Special versions** 1 = AgNi (50.12) ## **D: Special versions** ## **Series** 0 = Flux proof (RT II) 0 = Wash tight (RT III), 50.14, 50.16 4 = AgSnO2 (50.14) ## **Type** ## **C: Options** - 5 = AgNi + Au (50.12) 5 = AgSnO2 + Au (50.16) 1 = PCB 0 = CO ## **No. of poles** 1 = 1 NC 2 = 2 pole 8 A ## **B: Contact circuit** 2 = 2 NC 4 = 4 pole 8 A 6 = 6 pole 8 A 2 = 2 NO 0 = CO (DPDT) 3 = 3 NO **Coil version** 4 = 4 NO 9 = DC 5 = 5 NO ## **Coil voltage** See coil specifications ## **Technical data** |**Insulation according to EN 61810-1**|**Insulation according to EN 61810-1**|**Insulation according to EN 61810-1**|**Insulation according to EN 61810-1**| |---|---|---|---| |Nominal voltage of supplysystem<br>V AC||230/400|| |Rated insulation voltage<br>V AC||250|400| |Pollution degree||3|2| |**Insulation between coil and contact set**|||| |Type of insulation||Reinforced (8 mm)|| |Overvoltage category||III|| |Rated impulse voltage<br>kV (1.2/50µs)||6|| |Dielectric strength<br>V AC||4000|| |**Insulation between adjacent contacts**|||| |Type of insulation||Basic|| |Overvoltage category||III|| |Rated impulse voltage<br>kV (1.2/50µs)||4|| |Dielectric strength (50.12, 50.16)<br>V AC||3000|| |Dielectric strength (50.14)<br>V AC||2500|| |**Insulation between open contacts**|||| |Type of disconnection||Micro-disconnection|| |Dielectric strength<br>V AC/kV (1.2/50µs)||1500/2.5|| |**Insulation between coil terminals**|||| |Rated impulse voltage (surge) differential mode<br>(according to EN 61000-4-5)<br>kV(1.2/50 µs)||2|| |**Other data**|||| |Bounce time: NO/NC<br>ms||2/10|| |Vibration resistance (10…200)Hz: NO/NC<br>g||20/6|| |Shock resistance NO/NC|g|20/5|| |Power lost to the environment|without contact current<br>W|0.7|| ||with rated current<br>W|1.2|| |Recommended distance between relays mounted on PCB<br>mm||≥ 5|| **5** **50 SERIES** ## **Contact specification** **C** **F 50 - Electrical life (AC) v contact current (type 50.12)** **==> picture [215 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> Resistive load - cosφ = 1<br>Inductive load - cosφ = 0.4<br>Cycles<br>**----- End of picture text -----**<br> ## **H 50 - Maximum DC1 breaking capacity (type 50.12)** **==> picture [214 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> DC voltage (V)<br>DC breaking current (A)<br>**----- End of picture text -----**<br> - When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 10[3] can be expected. - In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. **==> picture [122 x 77] intentionally omitted <==** **==> picture [125 x 41] intentionally omitted <==** **----- Start of picture text -----**<br> Alternative selection of NO and NC<br>contacts to provide Forcibly guided<br>(mechanically linked) contacts, in<br>accordance with EN 61810-3 (type B).<br>**----- End of picture text -----**<br> ## **Coil specifications** **DC coil data (type 50.12)** |Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Resistance<br>R|Rated coil<br>consumption<br>Iat UN| |---|---|---|---|---|---| |V||V|V|Ω|mA| |5|**9**.005|3.8|6|35|143| |6|**9**.006|4.5|7.2|50|120| |12|**9**.012|9|14.4|205|58.5| |24|**9**.024|18|28.8|820|29.3| |48|**9**.048|36|57.6|3280|14.4| |60|**9**.060|45|72|5140|11.7| |110|**9**.110|82.5|131|17250|6.4| |125|**9**.125|93.7|150|22300|5.6| **R 50 - DC coil operating range v ambient temperature** Standard coil (type 50.12) **==> picture [215 x 129] intentionally omitted <==** **1 -** Max. permitted coil voltage. **2 -** Min. pick-up voltage with coil at ambient temperature. ## **DC coil data (type 50.14/16)** |Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Resistance<br>R|Rated coil<br>consumption<br>Iat UN| |---|---|---|---|---|---| |V||V|V|Ω|mA| |12|**9**.012|9|14.4|180|66.6| |24|**9**.024|18|28.8|720|33.3| |48|**9**.048|36|57.6|2880|16.6| |110|**9**.110|82.5|131|15125|7.7| **6** **50 SERIES** **C** ## **Contact specification** **F 50 - Electrical life (AC) v contact current (type 50.14)** **==> picture [214 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> Resistive load - cosφ = 1<br>Inductive load AC15<br>2 4 6 8<br>Cycles<br>**----- End of picture text -----**<br> ## **H 50 - Maximum DC1 breaking capacity (type 50.14)** **==> picture [212 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> DC voltage (V)<br>DC breaking current (A)<br>**----- End of picture text -----**<br> - When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 10[3] can be expected. - In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. ## **F 50 - Electrical life (AC) v contact current (type 50.16)** **==> picture [215 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> Resistive load - cosφ = 1<br>Inductive load AC15<br>2 4 6 8<br>Cycles<br>**----- End of picture text -----**<br> ## **H 50 - Maximum DC1 breaking capacity (type 50.16)** **==> picture [212 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> DC voltage (V)<br>DC breaking current (A)<br>**----- End of picture text -----**<br> - When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 10[3] can be expected. - In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. ## **Outline drawings** Types 50.12…1000/50.12…5000 Type 50.14 Type 50.16 **==> picture [73 x 73] intentionally omitted <==** Please see general technical information **7**
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →