Image not available
Illustrative purposes only
50.12.9.048.1000
Safety Relay, 48 VDC, DPDT, 50 Series, Through Hole, 8 A, Solder
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Safety Relays
- Coil Voltage:48VDC; Contact Configuration:DPDT; Product Range:-; Relay Mounting:Through Hole; Contact Current:8A; Relay Terminals:Solder; Contact Voltage AC Nom:250V; Contact Voltage DC N
- SVHC: No SVHC (04-Feb-2026)
- IP Rating: -
- Coil Voltage: 48VDC
- Product Range: 50 Series
- Relay Mounting: Through Hole
- Contact Current: 8A
- Relay Terminals: Solder
- Contact Material: Silver Nickel
- Contact Configuration: DPDT
- Contact Voltage AC Nom: 250V
- Contact Voltage DC Nom: -
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 11.27 € |
| Current stock | 50+ |
| Lead time | 30 days |
50 Series - Safety relay 8 A ## Features ## 50.12 PCB Relay with forcibly guided contacts according to EN 50205 type B 2 CO contacts * - High physical separation between adjacent contacts - Cadmium Free contact materials - 8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts - Flux proof: RT II - 2 Pole 8 A - 5 mm pinning - PCB mounting *According to EN 50205 only 1 NO and 1 NC (11-14 and 21-22 or 11-12 and 21-24) shall be used as forcibly guided contacts. _FOR UL HORSEPOWER AND PILOT DUTY RATINGS_ _SEE “General technical information” page_ V Copper side view ## Contact specification |Contact configuration|||||2 CO (DPDT)| |---|---|---|---|---|---| |Rated current/Maximumpeak current||||A|8/15| |Rated voltage/Maximum switchingvoltage||||V AC|250/400| |Rated load AC1||||VA|2,000| |Rated load AC15 (230 V AC)||||VA|500| |Singlephase motor rating(230 V AC)||(230 V AC)||kW|0.37| |BreakingcapacityDC1: 30/110/220 V|||DC1: 30/110/220 V|A|8/0.65/0.2| |Minimum switchingload||mW (V/mA)|mW (V/mA)||300 (5/5)| |Standard contact material|||||AgNi| |Coil specification|||||| |Nominal voltage (UN)|V AC (50/60 Hz)||||—| |||||V DC|5 - 6 - 12 - 24 - 48 - 60 - 110 - 125| |Ratedpower AC/DC||VA (50 Hz)/W|VA (50 Hz)/W||—/0.7| |Operating range||AC (50 Hz)|AC (50 Hz)||—| |||||DC|(0.75…1.2)UN| |Holding voltage|||AC/DC||—/0.4 UN| |Must drop-out voltage|||AC/DC||—/0.1 UN| |Technical data|||||| |Mechanical life AC/DC||||cycles|—/10 · 10<br>6| |Electrical life at rated load AC1||||cycles|100 · 10<br>3| |Operate/release time||||ms|10/4| |Insulation between coil and contacts (1.2/50µs) kV|||||6 (8 mm)| |Dielectric strength between open contacts||||V AC|1,500| |Ambient temperature range||||°C|–40…+70| |Environmental protection|||||RT II| |Approvals(according to type)|||||| 1 50 Series - Safety relay 8 A ## Ordering information Example: 50 series safety relay, 2 CO (DPDT) 8 A contacts, 24 V DC coil. ## A B C D 5 0 . 1 2 . 9 . 0 2 4 . 1 0 0 0 Series Type 1 = PCB - 5 mm pinning No. of poles 2 = 2 pole 8 A Coil version 9 = DC Coil voltage See coil specifications A: Contact material 1 = Standard AgNi 4 = AgSnO2 5 = AgNi + Au (5 µm) D: Special versions 0 = Flux proof (RT II) C: Options 0 = None B: Contact circuit 0 = CO (DPDT) Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. |Type|Coil version|A|B|C|D| |---|---|---|---|---|---| |50.12|DC|**1**- 4 - 5|**0**|**0**|**0**| ## Technical data |Insulation according to EN 61810-1|Insulation according to EN 61810-1|Insulation according to EN 61810-1|Insulation according to EN 61810-1| |---|---|---|---| |Nominal voltage of supplysystem<br>V AC||230/400|| |Rated insulation voltage<br>V AC||250|400| |Pollution degree||3|2| |Insulation between coil and contact set|||| |Type of insulation||Reinforced(8 mm)|| |Overvoltage category||III|| |Rated impulse voltage<br>kV(1.2/50µs)||6|| |Dielectric strength<br>V AC||4,000|| |Insulation between adjacent contacts|||| |Type of insulation||Basic|| |Overvoltage category||III|| |Rated impulse voltage<br>kV(1.2/50µs)||4|| |Dielectric strength<br>V AC||2,500|| |Insulation between open contacts|||| |Type of disconnection||Micro-disconnection|| |Dielectric strength<br>V AC/kV (1.2/50 µs)||1,500/2.5|| |Conducted disturbance immunity|||| |Burst(5...50)ns, 5 kHz, on A1 - A2||EN 61000-4-4|level 4(4 kV)| |Surge (1.2/50 µs) on A1 - A2 (differential mode)||EN 61000-4-5|level 3 (2 kV)| |Other data|||| |Bounce time: NO/NC<br>ms||2/10|| |Vibration resistance(10…200)Hz: NO/NC<br>g||20/6|| |Shock resistance NO/NC|g|20/5|| |Power lost to the environment|without contact current<br>W<br>with rated current<br>W|0.7|| |||1.2|| |Recommended distance between relays|mounted on PCB<br>mm|≥5|| 2 50 Series - Safety relay 8 A ## Contact specification F 50 - Electrical life (AC) v contact current **==> picture [251 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> Resistive load - cosϕ = 1<br>Cycles Inductive load - cosϕ = 0.4<br>**----- End of picture text -----**<br> ## H 50 - Maximum DC1 breaking capacity - DC voltage (V) - • When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100·103 can be expected. - In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. **==> picture [243 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> Alternative selection of NO and NC<br>contacts to provide Forcibly guided<br>(mechanically linked) contacts, in<br>accordance with EN 50205 (type B).<br>**----- End of picture text -----**<br> ## Coil specifications ## DC coil data |Nomina<br>voltage<br>UN|l<br>Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Resistance <br>R|Rated coil<br>consumption<br>Iat UN| |---|---|---|---|---|---| |V||V|V|Ω|mA| |5|9.005|3.8|6|35|143| |6|9.006|4.5|7.2|50|120| |12|9.012|9|14.4|205|58.5| |24|9.024|18|28.8|820|29.3| |48|9.048|36|57.6|3,280|14.4| |60|9.060|45|72|5,140|11.7| |110|9.110|82.5|131|17,250|6.4| |125|9.125|93.7|150|22,300|5.6| R 50 - DC coil operating range v ambient temperature Standard coil **==> picture [250 x 141] intentionally omitted <==** **==> picture [110 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> 1 - Max. permitted coil voltage.<br>**----- End of picture text -----**<br> - 2 - Min. pick-up voltage with coil at ambient temperature. 3
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →