- Manufacturer: FINDER
- Product type: Power Relays
- Contact Configuration:SPDT; Coil Voltage:12VDC; Contact Current:16A; Product Range:4C Series; Relay Mounting:DIN Rail; Coil Type:DC; Contact Voltage VAC:250VAC; Relay Terminals:Screw; Contact Vo
- SVHC: No SVHC (04-Feb-2026)
- Coil Type: Non Latching
- Coil Voltage: 12VDC
- Product Range: 4C Series
- Relay Mounting: DIN Rail
- Coil Resistance: 300ohm
- Contact Current: 16A
- Relay Terminals: Screw
- Contact Material: Silver Nickel
- Contact Voltage VAC: 250VAC
- Contact Voltage VDC: 30V
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 13.77 € |
| Current stock | 10+ |
| Lead time | 30 days |
**4C Series - Relay interface modules 8 - 10 - 16 A** @ ~~ti~~ nder ~~ee~~
## **Features**
## **4C.01**
**==> picture [28 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
4C.02<br>**----- End of picture text -----**<br>
## **1 & 2 pole relay interface modules, screw terminal socket, 15.8 mm wide.**
**Ideal interface for PLC and electronic systems 4C.01 - 1 Pole 16 A 4C.02 - 2 Pole 8 A**
- AC coils or DC coils
- Instant ejection of relay using plastic retaining clip
- Supply status indication and coil suppression module as standard
- Identification label
- UL Listing (certain relay/socket combinations)
- 1 pole, 16 A
• 2 pole, 8 A
- Screw terminal connection
- Screw terminal connection
- 35 mm rail (EN 50022) • 35 mm rail (EN 50022) mounting mounting
- 35 mm rail (EN 50022)
- 35 mm rail (EN 50022) mounting
|**1 & 2 pole relay interface modules,**<br>**screw terminal socket, 15.8 mm wide.**<br>**Ideal interface for PLC and electronic systems**<br>**4C.01 - 1 Pole 16 A**<br>**4C.02 - 2 Pole**<br>**8 A**<br>• AC coils or DC coilsAC coils or DC coils<br>•Instant ejection of relay using plastic<br>retaining clip<br>•Supply status indication and coil suppression<br>module as standard<br>• Identification labelIdentification label<br>• ULUL Listing (certain relay/socket combinations)<br>•35 mm rail (EN 50022) mounting<br>**Contact specification**<br>Contact configuration<br>4C.01 / 4C.02<br>Screw terminal<br>For outline drawing of 4C.01/02 see page 5|•1 pole, 16 A<br>• Screw terminal connectionScrew terminal connection<br>• 35 mm rail (EN 50022)35 mm rail (EN 50022)<br>mounting|•2 pole, 8 A<br>• Screw terminal connectionScrew terminal connection<br>• 35 mm rail (EN 50022)35 mm rail (EN 50022)<br>mounting<br>ae|
|---|---|---|
||**COM**<br>**NO**<br>**NC**<br>**11**<br>**14**<br>**12**<br>**DC**<br>**AC**<br>**A2**<br>**A1**<br>**A2**<br>**A1**<br>+<br>—<br>**COM**<br>**NO**<br>**NC**<br>**11**<br>**14**<br>**12**<br>1 CO (SPDT)<br>ca<br>oN<br>1<br>1<br>[ |<br>O<br>oo<br>7|**21**<br>**11**<br>**24**<br>**14**<br>**22**<br>**12**<br>**COM**<br>**NO**<br>**NC**<br>**21**<br>**11**<br>**24**<br>**14**<br>**22**<br>**12**<br>**COM**<br>**NO**<br>**NC**<br>**DC**<br>**AC**<br>**A2**<br>**A1**<br>**A2**<br>**A1**<br>—<br>+<br>2 CO (DPDT)<br>1<br>1<br>LI<br>Oo<br>Oo<br>7|
|Rated current/Maximum peak current<br>A|16/25<br>ee|8/15<br>ee|
|Rated voltage/Maximum switching voltage V AC|250/440<br>ee|250/440<br>ee|
|Rated load AC1<br>VA|4000<br>es|2000<br>es|
|Rated load AC15 (230 V AC)<br>VA|750<br>ee<br>ee|350<br>ee<br>ee|
|Single phase motor rating (230 V AC)<br>kW|0.55<br>ee|0.37<br>ee|
|Breaking capacity DC1: 30/110/220V<br>A|16/0.5/0.15<br>ee<br>ee|6/0.5/0.15<br>ee<br>ee|
|Minimum switching load<br>mW (V/mA)|300 (5/5)<br>ee|300 (5/5)<br>ee|
|Standard contact material<br>**Coil specification**<br>Nominal voltage (UN)<br>V AC (50/60 Hz)<br>V DC|AgNi<br>12 - 24 - 110 - 120 - 230|AgNi<br>12 - 24 - 110 - 120 - 230|
||12 - 24 - 125<br>es|12 - 24 - 125<br>es|
|Rated power AC/DC<br>VA (50 Hz)/W|1.2/0.5<br>ee|1.2/0.5<br>ee|
|Operating range<br>AC<br>DC|(0.8…1.1)UN<br>es|(0.8…1.1)UN<br>es|
||(0.73…1.1)UN<br>es|(0.73…1.1)UN<br>es|
|Holding voltage<br>AC/DC|0.8 UN /0.4 UN<br>es|0.8 UN /0.4 UN<br>es|
|Must drop-out voltage<br>AC/DC<br>**Technical data**<br>Mechanical life AC/DC<br>cycles|0.2 UN /0.1 UN<br>10 · 106|0.2 UN /0.1 UN<br>10 · 106|
|Electrical life at rated load AC1<br>cycles|100 · 103<br>ee|100 · 103<br>ee|
|Operate/release time<br>ms|15/5 (AC) - 15/12 (DC)<br>ee<br>ee|10/3 (AC) - 10/10 (DC)<br>ee<br>ee|
|Insulation between coil and contacts (1.2/50 µs) kV|6 (8 mm)<br>ee<br>ee|6 (8 mm)<br>ee<br>ee|
|Dielectric strength between open contacts<br>V AC|1000<br>ee<br>ee|1000<br>ee<br>ee|
|Ambient temperature range<br>°C|≤12A: –40…+70/>12A: –40…+50<br>ee<br>ee|–40…+70<br>ee<br>ee|
|Protection category|IP 20<br>es|IP 20<br>es|
|**Approvals - relay**(according to type)|ce<br>© S O Mss||
4C.01 / 4C.02 Screw terminal
For outline drawing of 4C.01/02 see page 5
**1**
**4C Series - Relay interface modules 8 - 10 - 16 A**
## **Features**
## **4C.51**
**==> picture [27 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
4C.52<br>**----- End of picture text -----**<br>
## **1 & 2 pole relay interface modules, screwless terminal socket, 15.8 mm wide.**
**Ideal interface for PLC and electronic systems 4C.51 - 1 Pole 10 A 4C.52 - 2 Pole 8 A**
- AC coils or DC coils
- Instant ejection of relay using plastic retaining clip
- 2 pole, 8 A
- 1 pole, 10 A
- Supply status indication and coil suppression module as standard
- Screwless terminal connections
- Screwless terminal connections
- 35 mm rail (EN 50022)
|**1 & 2 pole relay interface modules,**<br>**screwless terminal socket, 15.8 mm wide.**<br>**Ideal interface for PLC and electronic systems**<br>**4C.51 - 1 Pole 10 A**<br>**4C.52 - 2 Pole**<br>**8 A**<br>• AC coils or DC coilsAC coils or DC coils<br>•Instant ejection of relay using plastic<br>retaining clip<br>•Supply status indication and coil suppression<br>module as standard<br>•Identification label<br>•UL Listing (certain relay/socket combinations)<br>•35 mm rail (EN 50022) mounting<br>**Contact specification**<br>Contact configuration<br>4C.51 / 4C.52<br>Screwless terminal<br>For outline drawing of 4C.51/52 see page 5<br>~~Ant~~|•1 pole, 10 A<br>• Screwless terminal connectionsScrewless terminal connections<br>•35 mm rail (EN 50022)<br>mounting<br>~~Ant~~|•2 pole, 8 A<br>• Screwless terminal connectionsScrewless terminal connections<br>• 35 mm rail (EN 50022)35 mm rail (EN 50022)<br>mounting<br>~~Anta~~|
|---|---|---|
||**DC**<br>**AC**<br>**A2**<br>**A1**<br>**A2**<br>**A1**<br>+<br>—<br>**COM**<br>**NO**<br>**NC**<br>**11**<br>**14**<br>**12**<br>**COM**<br>**NO**<br>**NC**<br>**11**<br>**14**<br>**12**<br>1 CO (SPDT)<br>~~Ant~~<br>~~AS~~|**21**<br>**11**<br>**24**<br>**14**<br>**22**<br>**12**<br>**COM**<br>**NO**<br>**NC**<br>**21**<br>**11**<br>**24**<br>**14**<br>**22**<br>**12**<br>**COM**<br>**NO**<br>**NC**<br>**DC**<br>**AC**<br>**A2**<br>**A1**<br>**A2**<br>**A1**<br>—<br>+<br>2 CO (DPDT)<br>~~Anta~~<br>~~AS~~|
|Rated current/Maximum peak current<br>A<br>~~Ant~~|10/20<br>~~Ant~~|8/15<br>~~Ant a~~|
|Rated voltage/Maximum switching voltage V AC|250/440|250/440|
|Rated load AC1<br>VA|2500|2000|
|Rated load AC15 (230 V AC)<br>VA|750|350|
|Single phase motor rating (230 V AC)<br>kW|0.55|0.37|
|Breaking capacity DC1: 30/110/220V<br>A|10/0.5/0.15|6/0.5/0.15|
|Minimum switching load<br>mW (V/mA)|300 (5/5)|300 (5/5)|
|Standard contact material<br>**Coil specification**<br>Nominal voltage (UN)<br>V AC (50/60 Hz)<br>V DC|AgNi<br>12 - 24 - 110 - 120 - 230<br>~~po~~|AgNi<br>12 - 24 - 110 - 120 - 230<br>~~po~~|
||12 - 24 - 125<br>~~po~~|12 - 24 - 125<br>~~po~~|
|Rated power AC/DC<br>VA (50 Hz)/W|1.2/0.5|1.2/0.5|
|Operating range<br>AC<br>DC|(0.8…1.1)UN|(0.8…1.1)UN|
||(0.73…1.1)UN|(0.73…1.1)UN|
|Holding voltage<br>AC/DC|0.8 UN /0.4 UN|0.8 UN /0.4 UN|
|Must drop-out voltage<br>AC/DC<br>**Technical data**<br>Mechanical life AC/DC<br>cycles|0.2 UN /0.1 UN<br>10 · 106<br>~~po~~|0.2 UN /0.1 UN<br>10 · 106<br>~~po~~|
|Electrical life at rated load AC1<br>cycles|100 · 103<br>~~po~~|100 · 103<br>~~po~~|
|Operate/release time<br>ms|15/5 (AC) - 15/12 (DC)|10/3 (AC) - 10/10 (DC)|
|Insulation between coil and contacts (1.2/50 µs) kV|6 (8 mm)|6 (8 mm)|
|Dielectric strength between open contacts<br>V AC|1000|1000|
|Ambient temperature range<br>°C|–25…+70|–25…+70|
|Protection category|IP 20|IP 20|
|**Approvals - relay**(according to type)|||
**2**
**4C Series - Relay interface modules 8 - 10 - 16 A**
## **Ordering information**
Example: 4C series, 35 mm rail (EN 50022) mount screw terminal relay interface module, 1 CO (SPDT) 16 A contacts, 24 V DC coil, green LED + diode.
**A B C**
**D**
**4 C . 0 1 . 9 . 0 2 4 . 0 0**
## **5 0**
## **Series**
## **Type**
- 0 = 35 mm rail (EN 50022) mount screw terminal socket
- 5 = 35 mm rail (EN 50022) mount screwless terminal socket
## **No. of poles**
## **A: Contact material**
0 = AgNi
**B: Contact circuit**
0 = CO (nPDT)
## **D: Special version**
0 = Standard
## **C: Options**
5 = Standard for DC: green LED + diode (polarity +A1) 6 = Standard for AC: green LED + Varistor
1 = 1 pole
2 = 2 pole
## **Coil version**
8 = AC (50/60 Hz)
9 = DC
## **Coil voltage**
See coil specifications
## **Technical data**
|**Insulation**|||||||
|---|---|---|---|---|---|---|
|Insulation according to EN 61810-1|insulation rated voltage|V|250||440||
||rated impulse withstand voltage|kV|4||4||
||pollution degree||3||2||
||overvoltage category||III||III||
|Insulation between coil and contacts (1.2/50 µs)||kV|6 (8 mm)||||
|Dielectric strength between open contacts||V AC|1000||||
|Dielectric strength between adjacent contacts||V AC|2000||||
|**Conducted disturbance immunity**|||||||
|Burst(5...50)ns, 5 kHz, on A1 - A2|||EN 61000-4-4||level 4(4 kV)||
|Surge (1.2/50 µs) on A1 - A2 (differential mode)|||EN 61000-4-5||level 3 (2 kV)||
|**Other data**|||||||
|Bounce time: NO/NC||ms|2/6(4C.01/51)||1/4(4C.02/52)||
|Vibration resistance(10…150)Hz: NO/NC||g|20/12||||
|Power lost to the environment|without contact current|W|0.6||||
||with rated current|W|1.6 (4C.01/51)||2 (4C.02/52)||
||||**4C.01/4C.02**||**4C.51/4C.52**||
|Wire striplength||mm|8||8||
|S t||N|05||||
|crew orque<br>Max. wire size||m|.<br>solid cable<br>stranded cable||—<br> solid cable<br>stranded cable||
|||mm2|1x6/2x2.5|1x4/2x2.5|2x(0.2...1.5)|2x(0.2...1.5)|
|||AWG|1x10/2x14|1x12/2x14|2x(24...18)|2x(24...18)|
**3**
## **4C Series - Relay interface modules 8 - 10 - 16 A**
## **Contact specification**
## **F 4C - Electrical life (AC) v contact current**
Types 4C.02/52
**==> picture [250 x 305] intentionally omitted <==**
**----- Start of picture text -----**<br>
107<br>Resistive load - cos ϕ = 1<br>106 Inductive load - cos ϕ = 0.4<br>105<br>0 2 4 6 8<br>(A)<br>H 4C - Maximum DC1 breaking capacity<br>20<br>10 Current limit 1 CO (SPDT) (*)<br>6 Current limit 2 CO (DPDT)<br>4<br>2<br>1<br>0.2<br>0.1<br>20 60 100 140 180 220<br>DC voltage (V)<br>Cycles<br>DC breaking current (A)<br>**----- End of picture text -----**<br>
## **F 4C - Electrical life (AC) v contact current**
Types 4C.01/51
**==> picture [250 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
107<br>Resistive load - cos ϕ = 1<br>106 Inductive load - cos ϕ = 0.4<br>105<br>0 4 8 12 16<br>(A)<br>Cycles<br>**----- End of picture text -----**<br>
- (*) Type 4C.01= 12 A, Type 4C.51= 10 A
- When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100·10[3] can be expected.
- In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased.
## **Coil specifications**
## **DC coil data**
**==> picture [249 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal Coil Operating range Resistance Rated coil<br>voltage code consumption<br>UN Umin Umax R I at UN<br>V V V Ω mA<br>12 9 .012 8.8 13.2 300 40<br>24 9 .024 17.5 26.4 1200 20<br>125 9 .125 91.2 137.5 32000 3.9<br>**----- End of picture text -----**<br>
## **AC coil data**
**==> picture [249 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal Coil Operating range Resistance Rated coil<br>voltage code consumption<br>UN Umin Umax R I at UN<br>V V V Ω mA<br>12 8 .012 9.6 13.2 80 90<br>24 8 .024 19.2 26.4 320 45<br>110 8 .110 88 121 6900 9.4<br>120 8 .120 96 132 9000 8.4<br>230 8 .230 184 253 28000 5<br>**----- End of picture text -----**<br>
## **R 4C - DC coil operating range v ambient temperature**
**==> picture [250 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
U<br>2.0<br>UN<br>1 Single Pole Relay<br>1.5 Contact Current<br>limited to 12 A<br>1.0<br>2<br>0.5<br>-20 0 20 40 60 80<br>(°C)<br>**----- End of picture text -----**<br>
**==> picture [110 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 - Max. permitted coil voltage.<br>**----- End of picture text -----**<br>
- **2** - Min. pick-up voltage with coil at ambient temperature.
## **R 4C - AC coil operating range v ambient temperature**
**==> picture [250 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
U<br>2.0<br>UN<br>1<br>1.5 Single Pole Relay<br>Contact Current<br>limited to 12 A<br>1.0<br>2<br>0.5<br>-20 0 20 40 60 80<br>(°C)<br>**----- End of picture text -----**<br>
**==> picture [110 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 - Max. permitted coil voltage.<br>**----- End of picture text -----**<br>
**==> picture [199 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 - Min. pick-up voltage with coil at ambient temperature.<br>**----- End of picture text -----**<br>
Temperature limit for the single pole version under full 16 A contact current.
**4**
**4C Series - Relay interface modules 8 - 10 - 16 A** O ~~i~~ ne SP
|**Code**<br>4C.01|**Type of socket**<br>97.01|**Type of relay**<br>46.61|**Module**<br>99.02|**Retaining clip**<br>097.01|
|---|---|---|---|---|
|4C.02|97.02|46.52|99.02|097.01|
|4C.51|97.51|46.61|99.02|097.01|
|4C.52|97.52|46.52|99.02|097.01|
## **Outline drawing**
**==> picture [472 x 621] intentionally omitted <==**
**----- Start of picture text -----**<br>
15.8 15.8 3.6 61.7<br>64.6<br>21 4 4<br>15.8 15.8 3.5 23 19.2 19.2<br>= 114 MOC 621 MOC 113 i ry COM 4 11 P 21 6 COM 3 11<br>ON 143 245 ON 144 NO 3 14 24 5 NO 4 14<br>NC 122 227 NC 122 T o, r4 NC 2 12 22 7 NC 2 12 Ei<br>u o . |} | oe |<br>1 5 1 8<br>A2 COIL A1 A2 COIL A1 A2 1 COIL 5 A1 A2 1 COIL 8 A1<br>31.8<br>49.9 19<br>4C.01 / 4C.02 4C.51 / 4C.52 42.2<br>Screw terminal Screwless terminal<br>Accessories<br>8-way jumper link for 4C.01 and 4C.02 095.18 (blue)<br>Rated values 10 A - 250 V<br>a 095.18 ee<br>110.5<br>5.1<br>15 15.8 15.8 15.8 15.8 15.8 15<br>oS Sheet of marker tags Trt , plastic, 72 tags, 6x12 mm | 060.72<br>060.72<br>Packaging code<br>How to code and identify retaining clip and packaging options for relay interface module.<br>Example:<br>4 C . 0 1 . 9 . 0 2 4 . 0 0 5 0 S P A<br>A Standard packaging<br>B Blister packaging<br>rs: [|] SP Plastic retaining clip<br>[<br>30.6<br>25.9<br>3.2 3.2 35.4 95.6 3.2 95.6 3.2 34.7<br>32 32 38.3 38.3<br>21.6 30.3<br>3.3<br>7<br>10.3<br>**----- End of picture text -----**<br>
**5**
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →