4400.0031
CIRCUIT BREAKERS
- Manufacturer: SCHURTER
- Product type: Thermal Magnetic Circuit Breakers
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 1000 |
| Price | 6.32 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Thermal (T- and TA-Line)** https://www.schurter.com /PG17_20 T11-611 Circuit Breaker for Equipment thermal, Snap-in type, Reset type, Quick connect terminals See below: **Approvals and Compliances** ## **Description** - Snap-in version - Thermal circuit breaker - 1-pole - Reset type - Quick connect terminals 6.3 x 0.8 mm ## **Unique Selling Proposition** - Compact design ## **Applications** - Power tools - Household Equipment - Power supplies and chargers - Industrial appliances ## **Weblinks** pdf data sheet, html datasheet, General Product Information, DistributorStock-Check, Detailed request for product, Product News - Positively trip-free release - Available with cover - Different mounting possibilities ## **Technical Data** |**Technical Data**|| |---|---| |Rated Voltage AC|AC 240 VAC| |Rated Voltage DC|48 VDC| |Rated current range AC|0.05-16 A| |Conditional short circuit capa-|IEC 60934: PC1, AC 240 V: 2 kA| |city Inc|| |Short circuit capacity Icn|IEC 60934: at In < 6.5 A/240 VAC : 8| ||x In| ||IEC 60934: at In≥6.5 A/240 VAC : 96| ||A| |Degree of Protection|front side IP40 acc. to IEC 60529| |Dielectric Strength|50 Hz: > 1.5 kV| ||Impulse 1.2/50μs: > 2.5 kV| |Insulation Resistance|500 VDC > 100 MΩ| |Endurance typical|2 x Ir: 500 switching cycles| |Endurance minimum|Reset type| ||AC : 2 x Ir , cosφ0.6 :| ||DC : 2 x Ir , L/R = 2 - 3 ms :| ||50 switching cycles| |Overload|IEC: min. 40 trips| |---|---| ||@ 6 x Ir, cosφ0.6| |UL / CSA: min. 50 trips|| ||@ 1.5 x Ir, cosφ0.75| |Allowable Operation Temp.|-5°C to 60°C| |Vibration Resistance|± 1.5 mm @ 10 - 60 Hz| ||acc. to IEC 60068-2-6, test Fc| ||5 G @ 60 - 500 Hz| ||acc. to IEC 60068-2-6, test Fc| |Shock Resistance|100 G / 6 ms| ||acc. to IEC 60068-2-27, test Ea| |Tripping Type|Thermal| |Actuation Type|Reset type| |Weight|ca. 10 g| ## **Approvals and Compliances** Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. Circuit Breakers **1** **Thermal (T- and TA-Line)** https://www.schurter.com /PG17_20 T11-611 ## **Approvals** The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: T11 ||**Approval Logo**|**Approval Logo**|**Certificates**|**Certification Body**|**Description**| |---|---|---|---|---|---| ||||VDE Approvals|VDE|VDE Certificate Number: 99759| ||||UL Approvals|UL|UR File Number: E71572| ||||CCC Approvals|CCC|CCC Certificate Number: 2024010307710413| |**Product standards**|||||| |Product standards that are referenced|||||| ||**Organization**||**Design**|**Standard**|**Description**| ||||Designed according to|IEC 60934|Circuit-breakers for equipment (CBE)| ||||Designed according to|UL 1077|Standard for Supplementary Protectors for Use in Electrical Equipment| ||||Designed according to|CSA C22.2 No. 235|Supplementary Protectors| ||||Designed according to|GB 17701|Circuit-breaker for equipment| |**Application standards**|||||| |Application standards where the product can be used|||||| ||**Organization**||**Design**|**Standard**|**Description**| ||||Suitable for applications acc.|IEC/UL 62368-1|Audio/video, information and communication technology equipment - Part<br>1: Safety requirements| |**Compliances**|||||| |The product complies with following Guide Lines||The product complies with following Guide Lines|||| ||**Identification**||**Details**|**Initiator**|**Description**| |C€|||CE declaration of conformity|SCHURTER AG|The CE marking declares that the product complies with the applicable<br>requirements laid down in the harmonisation of Community legislation on| ||||||its affixing in accordance with EU Regulation 765/2008.| |UK|||UKCA declaration of conformity|SCHURTER AG|The UKCA marking declares that the product complies with the applicable| |cA|||||requirements laid down in the British Amendment of Regulation (EC)| ||||||765/2008.| ||||RoHS|SCHURTER AG|Directive RoHS 2011/65/EU, Amendment (EU) 2015/863| |@|||China RoHS|SCHURTER AG|The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March<br>2007. It is similar to the EU directive RoHS.| ||||REACH|SCHURTER AG|On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,| ||||||Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as| ||||||"REACH") entered into force.| | **2** | ELSCHURTER | Circuit Breakers **Thermal (T- and TA-Line)** https://www.schurter.com /PG17_20 T11-611 ## **Dimension [mm]** **==> picture [456 x 299] intentionally omitted <==** **----- Start of picture text -----**<br> T11-611 <7,5A T11-611 >7,5A T11-611N<br>Ø 4<br>14 3<br>25 3.6 1 2<br>12 13<br>11<br>15.2<br>21.6<br>6.3<br>Ø 4<br>2<br>13.5<br> 11.0 4<br>48.2<br>4.7<br>3 42<br>9.2<br>3.6<br>**----- End of picture text -----**<br> **==> picture [123 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> a b<br>0,8 21,9<br>1,0 22,0<br>1,5 22,1<br>2,0 22,3<br>3,0 22,6<br>b<br>11.3<br>a (0,8–3,0 mm)<br>**----- End of picture text -----**<br> Circuit Breakers **3** **Thermal (T- and TA-Line)** https://www.schurter.com /PG17_20 T11-611 |**Diagrams**|1<br>2<br> <br>1<br>3<br>2|| |---|---|---| |Rated current≤7,5 A||Rated current >7,5 A<br>1<br>3| |Shunt terminal T11-...N≤6,5 A||| ## **Typical internal resistance per pole** **==> picture [172 x 235] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Current [A] Internal Resistance [ Ω ]<br>0.05 380.000<br>0.50 5.200<br>1.00 1.350<br>2.00 0.300<br>3.00 0.130<br>4.00 0.080<br>5.00 0.040<br>6.00 0.040<br>7.00 0.020<br>8.00 0.012<br>9.00 0.012<br>10.00 0.011<br>11.00 0.0095<br>12.00 0.0095<br>13.00 0.0085<br>14.00 0.0085<br>15.00 0.0075<br>16.00 0.0075<br>**----- End of picture text -----**<br> Circuit Breakers **4** **Thermal (T- and TA-Line)** https://www.schurter.com /PG17_20 T11-611 ## **Effect of ambient temperature** The units are calibrated for an ambient temperature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: **==> picture [314 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> Ambient Temperature [°C] Correction factor<br>-5 0.87<br>0 0.90<br>+10 0.95<br>+23 1.00<br>+30 1.04<br>+40 1.10<br>+50 1.15<br>+60 1.20<br>**----- End of picture text -----**<br> Example: Rated current = 5 A, Environmental temperature = 40 °C, --> Correction factor = 1.1, Resulting current = 5.5 A --> Round to next higher rated current: 6 A ## **Time-Current-Curves** **==> picture [201 x 268] intentionally omitted <==** **----- Start of picture text -----**<br> [ min ] [ sec ]<br>10`000<br>< 6,5 A<br>60 > 6,5 A<br>30 2`000<br>20<br>1`000<br>10<br>500<br>5<br>200<br>100<br>1<br>50<br>20<br>10<br>5<br>2<br>1<br>0,5<br>0,3<br>0,2<br>0,1<br>1,05 1,35 2 3 4 5 8 10<br>Multiple of Rated Current In<br>Ambient temperature +23°<br>Time in Seconds<br>**----- End of picture text -----**<br> ## **Config. Code** ## ~~T11~~ ~~**|** -~~ ~~**|** 1~~ ~~**|** 2~~ ~~**|** 3~~ ~~**|** A~~ ~~**|** B~~ ~~**|** -~~ ~~**|** 1.23~~ ~~**|**~~ The characters are placeholders for the correspondingly keys of selections from the key tables. **==> picture [520 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Mounting Terminal Configuration<br>key<br>Mounting Configuration Quick connect terminal 6.3x0.8mm 1<br>key<br>Snap-in mounting from front side 6 T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Shunt terminal<br>T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Actuation Type Shunt terminal Configuration<br>key<br>Actuation Type Configuration Shunt terminal N<br>key<br>Reset type 1 T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Setting indication<br>**----- End of picture text -----**<br> ~~T11~~ ~~**|** -~~ ~~**|** 1~~ ~~**|** 2~~ ~~**| 3 |** A~~ ~~**|** B~~ ~~**|** -~~ ~~**|** 1.23~~ ~~**|**~~ **= Terminal** Circuit Breakers **5** **Thermal (T- and TA-Line)** https://www.schurter.com /PG17_20 T11-611 **==> picture [515 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> Setting indication Configuration<br>key Rated current Configuration<br>key<br>Setting indication R<br>T11 | - | 1 | 2 | 3 | A | B | - | 1.23 | = Rated current Other rated currents on request<br>**----- End of picture text -----**<br> ## **Variants** |**Rated current**<br>**Construction variants**<br>**Config. Code**<br>**Order Number**<br>**Shunt terminal**<br>**Setting indication**<br>2.0 A<br>-<br>4400.0002<br>3.5 A<br>-<br>4400.0200<br>10.0 A<br>-<br>4400.0030<br>16.0 A<br>-<br>4400.0034|| |---|---| |Availability for all products can be searched real-time:https://www.schurter.com/en/info-center/<br>support-tools/stock-check-distributors|| |**Packaging Unit**<br>100 Pcs|| The specifications, descriptions and illustrations indicated in this document are based on current ~~information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.~~ Circuit Breakers **6**
Updated at June 9, 2026
SCHURTER is a globally recognized innovator and manufacturer of high-quality electronic components, specializing in products that ensure a safe and clean supply of power. With a strong reputation in the electronics and PCB assembly industries, the company delivers reliable solutions engineered to protect critical circuits, streamline device operation, and optimize electrical performance across diverse applications. The core of our SCHURTER portfolio revolves around comprehensive circuit protection. We carry an extensive selection of standard and resettable fuses, accompanied by robust fuse holders, to safeguard sensitive electronics against overcurrent conditions. Furthermore, our offering features high-performance thermal circuit breakers and associated accessories, providing dependable protection and rapid reset capabilities for demanding industrial and commercial environments. Beyond fundamental circuit protection, SCHURTER excels in electromagnetic compatibility (EMC) and RFI suppression technologies. Our range includes precision-engineered power line filters and common mode chokes designed to mitigate electromagnetic interference and ensure signal integrity. Accompanied by specialized components such as AC/DC LED power supplies, SCHURTER provides the meticulous engineering and durability necessary for modern, high-reliability electronic design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →