Image not available
Illustrative purposes only
3VA2025-5HN42-0AA0
Electronic Circuit Breaker, MCCB, 3VA2, 4P, 55 kA, 415 V, 25 A, Without Auxiliary Contact
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Electronic Circuit Breakers
- SVHC: To Be Advised
- Trip Time: -
- No. of Poles: 4 Pole
- Product Range: SENTRON 3VA2 Series
- Current Rating: 250A
- Supply Voltage: 690V
- Load Current Max: -
- Circuit Breaker Mounting: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 838.68 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3VA2025-5HN42-0AA0**
**Data sheet**
circuit breaker 3VA2 IEC Frame 100 breaking capacity class M Icu=55 kA @ 415 V 4-pole, line protection ETU350, LSI, In=25 A overload protection Ir=10 A...25 A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In neutral conductor protection adjustable (OFF, 100%) nut keeper kit
|**Model**||
|---|---|
|product brand name|SENTRON|
|product designation|Molded case circuit breaker|
|design of theproduct|Lineprotection|
|design of the overcurrent release|ETU350|
|protection function of the overcurrent release|LSI|
|number of poles|4|
|**General technical data**||
|insulation voltage / rated value|800 V|
|operatingvoltage / at AC / rated value|690 V|
|power loss[W]/ maximum|0.84 W|
|power loss [W] / for rated value of the current / at AC / in hot|0.28 W|
|operatingstate /perpole||
|mechanical service life(operatingcycles)/ typical|25 000|
|electrical endurance(operatingcycles)/ at AC-1 / at 380/415 V|15 000|
|electrical endurance(operatingcycles)/ at AC-1 / at 690 V|10 500|
|product feature / for neutral conductors / upgradable/retrofittable|No|
|/ short-circuit and overloadproof||
|ground-fault monitoringversion|Without|
|product function||
|● communication function|No|
|● other measurement function|No|
|Net Weight|2.716 kg|
|**Current**||
|operational current||
|● at 40 °C|25 A|
|● at 45 °C|25 A|
|● at 50 °C|25 A|
|● at 55 °C|25 A|
|● at 60 °C|25 A|
|● at 65 °C|25 A|
|● at 70 °C|25 A|
|**Switching capacity according to IEC 60947**||
|switchingcapacityclass of the circuit breaker|M|
|maximum short-circuit current breakingcapacity (Icu)||
|● at 240 V|85 kA|
Subject to change without notice © Copyright Siemens
3VA20255HN420AA0 Page 1/6
6/3/2026
|● at 415 V|55 kA|
|---|---|
|● at 440 V|55 kA|
|● at 500 V|36 kA|
|● at 690 V|2 kA|
|operatingshort-circuit current breakingcapacity (Ics)||
|● at 240 V|85 kA|
|● at 415 V|55 kA|
|● at 440 V|55 kA|
|● at 500 V|36 kA|
|● at 690 V|2 kA|
|short-circuit current makingcapacity (Icm)||
|● at 240 V|187 kA|
|● at 415 V|121 kA|
|● at 440 V|121 kA|
|● at 500 V|75.5 kA|
|● at 690 V|3 kA|
|**Adjustable parameters**||
|product feature / for L-tripping/ can be switched on/off|No|
|adjustable response value setting current (Ir) / of the L-trip / with<br>I2t characteristic||
|● minimum|10 A|
|● maximum|25 A|
|adjustable response value delay time (tr) / for L-tripping / with I2t<br>characteristic||
|● minimum|0.5 s|
|● maximum|17 s|
|adjustable response value setting current (Isd) / of S-trip / with<br>I2t characteristic||
|● minimum|15 A|
|● maximum|250 A|
|adjustable response value delay time (tsd) / for S-tripping / with<br>I2t characteristic||
|● minimum|0.0001 s|
|● maximum|0.4 s|
|adjustable response value settingcurrent(Ii)/ for I-tripping||
|● minimum|300 A|
|● maximum|300 A|
|adjustable settingcurrent(InN)/ for N-tripping||
|● minimum|10 A|
|● maximum|25 A|
|design of the N-conductorprotection|adjustable OFF; 100%|
|product function /groundingprotection|No|
|**Mechanical Design**||
|product component||
|● undervoltage release|No|
|● voltage trigger|No|
|● tripindicator|No|
|height[in]|7.13 in|
|height|181 mm|
|width[in]|5.51 in|
|width|140 mm|
|depth[in]|3.39 in|
|depth|86 mm|
|**Connections**||
|arrangement of electrical connectors / for main current circuit|Front terminal|
|type of electrical connection / for main current circuit|on both sides nut keeper kit|
|type of connectable conductor cross-sections / for flat-bar<br>terminal connection / minimum|13 x 1 mm|
|type of connectable conductor cross-sections / for flat-bar<br>terminal connection / maximum|25 x 8 mm|
Subject to change without notice © Copyright Siemens
3VA20255HN420AA0 Page 2/6
6/3/2026
|design of the surface / of the connections / on the top of the|design of the surface / of the connections / on the top of the|design of the surface / of the connections / on the top of the||tin|||||
|---|---|---|---|---|---|---|---|---|
|switch(N, 1, 3, 5)|||||||||
|design of the surface / of the connections / on the bottom of the||||tin|||||
|switch(N, 2, 4, 6)|||||||||
|**Auxiliary circuit**<br>~~a~~|||||||||
|number of CO contacts / for auxiliarycontacts||||0|||||
|**Accessories**<br>~~a~~|||||||||
|product extension / optional / motor drive||||Yes|||||
|**Environmental conditions**<br>~~a~~|||||||||
|protection class IP / on the front||||IP40|||||
|ambient temperature|||||||||
|● duringoperation / minimum||||-25 °C|||||
|● duringoperation / maximum||||70 °C|||||
|● duringstorage / minimum||||-40 °C|||||
|● duringstorage / maximum||||80 °C|||||
|**Environmental footprint**<br>~~a~~|||||||||
|global warming potential[CO2 eq]/ total||||61.814 k||61.814 kg|||
|global warming potential[CO2 eq]/ duringmanufacturing||||14.6 kg|||||
|global warming potential[CO2 eq]/ duringoperation||||48.9 kg|||||
|global warming potential[CO2 eq]/ after end of life||||-2.2 kg|||||
|Siemens Eco Profile(SEP)<br>~~re~~||||Siemens EcoTech|||||
|**reference code / according to IEC 81346-2**||||Q|||||
|**Approvals / Certificates**|||||||||
|**General Product Approval**|||||||||
|||Miscellaneous<br>~~EA~~L||||||Confirmation<br>~~_~~|
|**General Product Approval**|**EMV**|||||**Test Certificates**|||
|UK<br>ca<br>Sf||@||||Miscellaneous<br>~~—_—~~|Special Test Certific-<br>ate|Type Test Certific-<br>ates/Test Report|
|**Maritime application**|||||||||
|||||||||CCS (China Classifica-|
|||||||||tion Society)|
|=<br>a2||a||||us|a||
|**other**|||||||**Dangerous goods**|**Environment**|
|Miscellaneous<br>Miscellaneous<br>Confirmation<br>~~ss~~|||||||Transport Information|Environmental Con-|
|||||||||firmations|
|||||||QC PASS|||
|**Environment**|||||||||
|Environmental Con-|||||||||
|firmations|||||||||
**Further information** ~~ee~~ **Information on the packaging**
Subject to change without notice © Copyright Siemens
3VA20255HN420AA0 Page 3/6
6/3/2026
https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/lowvoltage/catalogs **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3VA2025-5HN42-0AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3VA2025-5HN42-0AA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)** https://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3VA2025-5HN42-0AA0 **CAx-Online-Generator** https://www.siemens.com/cax **Tender specifications** https://www.siemens.com/specifications **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no>
**==> picture [203 x 225] intentionally omitted <==**
Subject to change without notice © Copyright Siemens
3VA20255HN420AA0 Page 4/6
6/3/2026
**==> picture [259 x 330] intentionally omitted <==**
**----- Start of picture text -----**<br>
-Q<br>cLr ~y yi yi VL ETU350<br>L<br>I> S<br>E ERE] I> I> I> I> | a I>> I<br>N N<br>PPT |r<br>I>> I>> I>> I>><br>TT<br>——<br>| |<br>¢ ||<br>| [|]<br>¢ |<br>| [|]<br>{|<br>EFB RCD<br>|<br>1 3 5 7<br>N<br>N<br>2 4 6 8 -X2 -X3<br>**----- End of picture text -----**<br>
**last modified:**
4/23/2026
Subject to change without notice © Copyright Siemens
3VA20255HN420AA0 Page 5/6
6/3/2026
Subject to change without notice © Copyright Siemens
3VA20255HN420AA0 Page 6/6
6/3/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →