3RW5527-1HA06
Soft Starter, 3RW Series, Three Phase, 93 A, 200 V to 690 V, 90 kW at 690 V, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: -
- Power Rating: 45kW
- No. of Phases: Three Phase
- Product Range: SIRIUS 3RW55
- Current Rating: 93A
- IP / NEMA Rating: IP00
- Motor Starter Type: Soft Starter
- Supply Voltage Max: 690VAC
- Supply Voltage Min: 200VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 2470.8 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RW5527-1HA06** **Data sheet** SIRIUS soft starter 200-690 V 93 A, 24 V AC/DC Screw terminals |Siemens<br>EcoTech|SIRIUS soft starter 200-690 V 93 A, 24 V AC/DC Screw terminals| |---|---| |**product brand name**|SIRIUS| |**product category**|Hybrid switchingdevices| |**product designation**|Soft starter| |**product type designation**|3RW55| |**manufacturer's article number**|| |● of high feature HMI module usable|3RW5980-0HF00| |● of communication module PROFINET standard usable|3RW5980-0CS00| |● of communication module PROFINET high-feature usable|3RW5950-0CH00| |● of communication module PROFIBUS usable|3RW5980-0CP00| |● of communication module Modbus TCP usable|3RW5980-0CT00| |● of communication module Modbus RTU usable|3RW5980-0CR00| |● of communication module Ethernet/IP|3RW5980-0CE00| |● of circuit breaker usable at 400 V|3VA2216-7MN32-0AA0; Type of coordination 1, Iq=15 kA, CLASS 10| |● of circuit breaker usable at 500 V|3VA2216-7MN32-0AA0; Type of coordination 1, Iq=10 kA, CLASS 10| |● of circuit breaker usable at 400 V at inside-delta circuit|3VA2220-7MN32-0AA0; Type of coordination 1, Iq=15 kA, CLASS 10| |● of circuit breaker usable at 500 V at inside-delta circuit|3VA2220-7MN32-0AA0; Type of coordination 1, Iq=10 kA, CLASS 10| |● of thegG fuse usable upto 690 V|3NA3136-6; Type of coordination 1, Iq=65 kA| |● of thegG fuse usable at inside-delta circuit upto 500 V|3NA3136-6; Type of coordination 1, Iq=65 kA| |● of full range R fuse link for semiconductor protection<br>usable upto 690 V|3NE1224-0; Type of coordination 2, Iq=65 kA| |● of back-up R fuse link for semiconductor protection<br>usable up to 690 V|3NE3227; Type of coordination 2, Iq=65 kA| |**General technical data**|| |**starting voltage [%]**|20 ... 100 %| |**stopping voltage [%]**|50 %; non-adjustable| |**start-up ramp time of soft starter**|0 ... 360 s| |**ramp-down time of soft starter**|0 ... 360 s| |**start torque[%]**|10 ... 100 %| |**stopping torque[%]**|10 ... 100 %| |**torque limitation[%]**|20 ... 200 %| |**current limiting value[%] adjustable**|125 ... 800 %| |**breakaway voltage [%] adjustable**|40 ... 100 %| |**breakaway time adjustable**|0 ... 2 s| |**number ofparameter sets**|3| |**accuracy class**|5(based on IEC 61557-12)| |**certificate of suitability**|| |● CE marking|Yes| |● UL approval|Yes| |● CSA approval|Yes| |**product component**|| |● HMI-High Feature|Yes| |● is supported HMI-High Feature|Yes| |**product feature integrated bypass contact system**|Yes| |**number of controlledphases**|3| |**current unbalance limiting value[%]**|10 ... 60 %| |**ground-fault monitoring limiting value[%]**|10 ... 95 %| |**buffering time in the event ofpower failure**|| |● for main current circuit|100 ms| Subject to change without notice © Copyright Siemens 3RW55271HA06 Page 1/7 5/30/2026 |● for control circuit|100 ms| |---|---| |**idle time adjustable**|0 ... 255 s| |**insulation voltage rated value**|690 V| |**degree ofpollution**|3, acc. to IEC 60947-4-2| |**impulse voltage rated value**|8 kV| |**blocking voltage of the thyristor maximum**|1 800 V| |**service factor**|1.15| |**surge voltage resistance rated value**|8 kV| |**maximumpermissible voltage forprotective separation**|| |● between main and auxiliarycircuit|690 V; does not applyfor thermistor connection| |**shock resistance**|15g/ 11 ms, from 6g/ 11 ms withpotential contact lifting| |**vibration resistance**|15 mm upto 6 Hz; 2gupto 500 Hz| |**recovery time after overload trip adjustable**|60 ... 1 800 s| |utilization categoryaccordingto IEC 60947-4-2|AC 53a| |**reference code according to IEC 81346-2**|Q| |**Substance Prohibitance(day/month/year)**|02/15/2018| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1<br>Dibutylbis(pentane-2,4-dionato-O,O')tin CAS-No. 22673-19-4<br>Diboron trioxide CAS-No. 1303-86-2<br>Lead titanium trioxide CAS-No. 12060-00-3| |**Net Weight**|8.131 kg| |**product function**|| |● ramp-up (soft starting)|Yes| |● soft stopping|Yes| |● breakaway pulse|Yes| |● adjustable current limitation|Yes| |● creepspeed in both directions of rotation|Yes| |●pumpstop|Yes| |● DC braking|Yes| |● motor heating|Yes| |● min/maxpointer|Yes| |● trace function|Yes| |● intrinsic deviceprotection|Yes| |● motor overload protection|Yes; Full motor protection (thermistor motor protection and electronic motor<br>overloadprotection)| |● evaluation of thermistor motorprotection|Yes; Type A PTC or Klixon / Thermoclick| |● inside-delta circuit|Yes; Onlyupto 600 V operatingvoltage| |● auto-RESET|Yes| |● manual RESET|Yes| |● remote reset|Yes| |● communication function|Yes| |● operatingmeasured value display|Yes| |● event list|Yes| |● error logbook|Yes| |● via softwareparameterizable|Yes| |● via software configurable|Yes| |● screw terminal|Yes| |● spring-loaded terminal|No| |**● PROFIenergy**|Yes; in connection with the PROFINET Standard and PROFINET High-Feature<br>communication modules| |**● firmware update**|Yes| |**● removable terminal for control circuit**|Yes| |● voltage ramp|Yes| |● torque control|Yes| |● combined braking|Yes| |● analogoutput|Yes; 4 ... 20 mA(default)/ 0 ... 10 V| |● programmable control inputs/outputs|Yes| Subject to change without notice © Copyright Siemens 3RW55271HA06 Page 2/7 5/30/2026 ||● condition monitoring|Yes|| |---|---|---|---| ||● automaticparameterisation|Yes|| ||● application wizards|Yes|| ||● alternative stoppingmode|Yes|| ||● emergencyoperation mode|Yes|| ||● reversingoperation|Yes|| ||● soft startingat heavystartingconditions|Yes|| ||**Power Electronics**||| ||**operational current**||| ||● at 40 °C rated value|93 A|| ||● at 40 °C rated value minimum|19 A|| ||● at 50 °C rated value|82.5 A|| ||● at 60 °C rated value|75.5 A|| ||**operational current at inside-delta circuit**||| ||● at 40 °C rated value|161 A|| ||● at 50 °C rated value|143 A|| ||● at 60 °C rated value|131 A|| ||**operating voltage**||| ||● rated value|200 ... 690 V|| ||● at inside-delta circuit rated value|200 ... 600 V|| ||**relative negative tolerance of the operating voltage**|-15 %|| ||**relativepositive tolerance of the operating voltage**|10 %|| ||**relative negative tolerance of the operating voltage at**<br>**inside-delta circuit**|-15 %|| ||**relative positive tolerance of the operating voltage at**<br>**inside-delta circuit**|10 %|| ||**operating power for 3-phase motors**||| ||● at 230 V at 40 °C rated value|22 kW|| ||● at 230 V at inside-delta circuit at 40 °C rated value|45 kW|| ||● at 400 V at 40 °C rated value|45 kW|| ||● at 400 V at inside-delta circuit at 40 °C rated value|90 kW|| ||● at 500 V at 40 °C rated value|55 kW|| ||● at 500 V at inside-delta circuit at 40 °C rated value|110 kW|| ||● at 690 V at 40 °C rated value|90 kW|| ||**Operating frequency 1 rated value**|50 Hz|| ||**Operating frequency 2 rated value**|60 Hz|| ||**relative negative tolerance of the operating frequency**|-10 %|| ||**relativepositive tolerance of the operating frequency**|10 %|| ||**minimum load[%]**|10 %; Relative to set Ie|| ||**power loss[W] for rated value of the current at AC**||| ||● at 40 °C after startup|28 W|| ||● at 50 °C after startup|25 W|| ||● at 60 °C after startup|23 W|| ||**power loss[W] at AC at current limitation 350 %**||| ||● at 40 °C duringstartup|1 258 W|| ||● at 50 °C duringstartup|1 065 W|| ||● at 60 °C duringstartup|948 W|| ||**type of the motor protection**|Electronic, trippingin the event of thermal overload of the motor|| ||**Control circuit/ Control**||| ||**type of voltage of the control supply voltage**|AC/DC|| ||**control supply voltage at AC**||| ||● at 50 Hz rated value|24 V|| ||● at 60 Hz rated value|24 V|| ||**relative negative tolerance of the control supply voltage at**<br>**AC at 50 Hz**|-20 %|| ||**relative positive tolerance of the control supply voltage at**<br>**AC at 50 Hz**|20 %|| ||**relative negative tolerance of the control supply voltage at**<br>**AC at 60 Hz**|-20 %|| ||**relative positive tolerance of the control supply voltage at**<br>**AC at 60 Hz**|20 %|| Subject to change without notice © Copyright Siemens 3RW55271HA06 Page 3/7 5/30/2026 ||**control supply voltage frequency**|50 ... 60 Hz|| |---|---|---|---| ||**relative negative tolerance of the control supply voltage**<br>**frequency**|-10 %|| ||**relative positive tolerance of the control supply voltage**<br>**frequency**|10 %|| ||**control supply voltage at DC rated value**|24 V|| ||**relative negative tolerance of the control supply voltage at**<br>**DC**|-20 %|| ||**relative positive tolerance of the control supply voltage at**<br>**DC**|20 %|| ||**control supply current in standby mode rated value**|440 mA|| ||**holding current in bypass operation rated value**|870 mA|| ||**inrush current by closing the bypass contacts maximum**|6.3 A|| ||inrush current peak at application of control supply voltage<br>maximum|7.5 A|| ||duration of inrush current peak at application of control supply<br>voltage|20 ms|| ||**design of the overvoltage protection**|Varistor|| ||**design of short-circuit protection for control circuit**|4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit<br>breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of<br>scope of supply|| ||**Inputs/ Outputs**||| ||**number of digital inputs**|4|| ||●parameterizable|4|| ||||| ||**● number of digital outputs**|4|| ||● number of digital outputsparameterizable|3|| ||● number of digital outputs notparameterizable|1|| ||**digital output version**|3 normally-open contacts(NO)/ 1 changeover contact(CO)|| ||**number of analog outputs**|1|| ||**switching capacity current of the relay outputs**||| ||● at AC-15 at 250 V rated value|3 A|| ||● at DC-13 at 24 V rated value|1 A|| ||**Installation/ mounting/ dimensions**||| ||**mounting position**|Vertical(can be rotated +/- 90° and tilted forward or backward +/- 22.5°)|| ||**fastening method**|screw fixing|| ||**height**|306 mm|| ||**width**|185 mm|| ||**depth**|203 mm|| ||required spacingwith side-by-side mounting||| ||● forwards|10 mm|| ||● backwards|0 mm|| ||● upwards|100 mm|| ||● downwards|75 mm|| ||● at the side|5 mm|| ||**weight without packaging**|7.15 kg|| ||**Connections/ Terminals**||| ||**type of electrical connection**||| ||● for main current circuit|box terminal|| ||● for control circuit|screw-type terminals|| ||**width of connection bar maximum**|25 mm|| ||**wire length for thermistor connection**||| ||● with conductor cross-section = 0.5 mm² maximum|50 m|| ||● with conductor cross-section = 1.5 mm² maximum|150 m|| ||● with conductor cross-section = 2.5 mm² maximum|250 m|| ||**type of connectable conductor cross-sections for main**<br>**contacts for box terminal**||| ||● usingthe front clamping point solid|1x(2.5 ... 16 mm²)|| ||● using the front clamping point finely stranded with core<br>endprocessing|1x (2.5 ... 50 mm²)|| ||● usingthe front clamping point stranded|1x(10 ... 70 mm²)|| ||● using the back clamping point solid|1x (2.5 ... 16 mm²)|| Subject to change without notice © Copyright Siemens 3RW55271HA06 Page 4/7 5/30/2026 |● r box terminal usingthe back clamping point|1x(10 ... 2/0)| |---|---| |● usingboth clamping points solid|2x(2.5 ... 16 mm²)| |● using both clamping points finely stranded with core end<br>processing|2x (2.5 ... 35 mm²)| |● usingboth clamping points stranded|2x(6 ... 16 mm²), 2x(10 ... 50 mm²)| |● using the back clamping point finely stranded with core<br>endprocessing|1x (2.5 ... 50 mm²)| |● usingthe back clamping point stranded|1x(10 ... 70 mm²)| |**type of connectable conductor cross-sections**|| |● for control circuit solid|1x(0.5 ... 4.0 mm²), 2x(0.5 ... 2.5 mm²)| |● for control circuit finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.5 mm²)| |● for AWG cables for control circuit solid|1x(20 ... 12), 2x(20 ... 14)| |**wire length**|| |● between soft starter and motor maximum|800 m| |● at the digital inputs at DC maximum|1 000 m| |**tightening torque**|| |● for main contacts with screw-type terminals|4.5 ... 6 N·m| |● for auxiliary and control contacts with screw-type<br>terminals|0.8 ... 1.2 N·m| |**tightening torque[lbf·in]**|| |● for main contacts with screw-type terminals|40 ... 53 lbf·in| |● for auxiliary and control contacts with screw-type<br>terminals|7 ... 10.3 lbf·in| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C; Please observe deratingat temperatures of 40 °C or above| |● duringstorage and transport|-40 ... +80 °C| |**environmental category**|| |● during operation according to IEC 60721|3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2<br>(sand must notget into the devices), 3M6| |● during storage according to IEC 60721|1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get<br>inside the devices), 1M4| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2(max. fall height 0.3 m)| |**Electromagnetic compatibility**|| |**EMC emitted interference**|acc. to IEC 60947-4-2: Class A| |**Communication/ Protocol**|| |**communication module is supported**|| |● PROFINET standard|Yes| |● PROFINET high-feature|Yes| |● EtherNet/IP|Yes| |● Modbus RTU|Yes| |● Modbus TCP|Yes| |● PROFIBUS|Yes| |**UL/CSA ratings**|| |**manufacturer's article number**|| |**● of circuit breaker usable for Standard Faults**|| |— at 460/480 V accordingto UL|Siemens type: 3VA51, max. 125 A; Iq= 10 kA| |— 60/480 V accordingto UL|Siemens type: 3VA51, max. 125 A; Iqmax = 65 kA| |— at 460/480 V at inside-delta circuit accordingto UL|Siemens type: 3VA51, max. 125 A; Iq= 10 kA| |— 60/480 V at inside-delta circuit accordingto UL|Siemens type: 3VA51, max. 125 A; Iqmax = 65 kA| |— at 575/600 V accordingto UL|Siemens type: 3VA51, max. 125 A; Iq= 10 kA| |— 75/600 V at inside-delta circuit accordingto UL|Siemens type: 3VA51, max. 125 A; Iqmax = 65 kA| |— at 575/600 V at inside-delta circuit accordingto UL|Siemens type: 3VA51, max. 125 A; Iq= 10 kA| |**● of the fuse**|| |— usable for Standard Faults up to 575/600 V<br>accordingto UL|Type: Class RK5 / K5, max. 300 A; Iq = 10 kA| |— usable for High Faults up to 575/600 V according to<br>UL|Type: Class J / L, max. 250 A; Iq = 100 kA| |— usable for Standard Faults at inside-delta circuit up<br>to 575/600 V according to UL|Type: Class RK5 / K5, max. 300 A; Iq = 10 kA| Subject to change without notice © Copyright Siemens 3RW55271HA06 Page 5/7 5/30/2026 |— usable for High Faults at inside-delta circuit up to<br>575/600 V accordingto UL|Type: Class J / L, max. 250 A; Iq = 100 kA| |---|---| |**operating power[hp] for 3-phase motors**|| |● at 200/208 V at 50 °C rated value|25 hp| |● at 220/230 V at 50 °C rated value|30 hp| |● at 460/480 V at 50 °C rated value|60 hp| |● at 575/600 V at 50 °C rated value|75 hp| |● at 200/208 V at inside-delta circuit at 50 °C rated value|40 hp| |● at 220/230 V at inside-delta circuit at 50 °C rated value|50 hp| |● at 460/480 V at inside-delta circuit at 50 °C rated value|100 hp| |● at 575/600 V at inside-delta circuit at 50 °C rated value<br>~~_py~~|125 hp<br>~~py~~| |**contact rating of auxiliary contacts according to UL**<br>~~_py~~|R300-B300<br>~~py~~| |Electrical Safety<br>~~_py~~|| |**protection class IP on the front according to IEC 60529**<br>~~_py~~|IP00; IP20 with cover<br>~~py~~| |**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front with cover| |**ATEX**<br>~~a~~|| |**Safety Integrity Level (SIL) according to IEC 61508 relating**<br>**to ATEX**<br>~~a~~|SIL 1<br>~~a~~| |**PFHD with high demand rate according to IEC 61508**<br>**relating to ATEX**|5E-7 1/h| |**PFDavg with low demand rate according to IEC 61508**<br>**relating to ATEX**|0.008| |**hardware fault tolerance according to IEC 61508 relating to**<br>**ATEX**|0| |**T1 value for proof test interval or service life according to**<br>**IEC 61508 relating to ATEX**|3 a| |**certificate of suitability**|| |● ATEX|Yes| |● IECEx|Yes| |● accordingto ATEX directive 2014/34/EU|BVS 18 ATEX F 003 X| |**type of protection according to ATEX directive 2014/34/EU**|II (2)G [Ex eb Gb] [Ex db Gb] [Ex pxb Gb], II (2)D [Ex tb Db] [Ex pxb Db], I (M2)<br>[Ex db Mb]| |**Approvals Certificates**<br>~~ee~~|| |Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>92.599 kg<br>● global warming potential [CO2 eq] / during sales<br>2.37 kg<br>● global warming potential [CO2 eq] / during operation<br>324 kg<br>● global warming potential [CO2 eq] / after end of life<br>-19.4 kg<br>● global warming potential [CO2 eq] / total<br>399 kg<br>**Environment**<br>**General Product Approval**<br>~~ee~~|| **General Product Approval EMV** **For use in hazardous locations** **Test Certificates Maritime application** - Type Test Certific ates/Test Report ~~=~~ e **other** Subject to change without notice © Copyright Siemens 3RW55271HA06 Page 6/7 5/30/2026 > Confirmation ~~—_ ——~~ Confirmation ~~e~~ **Further information** ~~C~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW5527-1HA06 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RW5527-1HA06 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW5527-1HA06&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW5527-1HA06 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **Characteristic: Tripping characteristics, I²t, Let-through current** https://support.industry.siemens.com/cs/ww/en/ps/3RW5527-1HA06/char **Characteristic: Installation altitude** https://www.automation.siemens.com/bilddb/index.aspx?gridview=view2&objkey=G_NSB0_XX_01704&showdetail=true&view=Search **Simulation Tool for Soft Starters (STS)** https://support.industry.siemens.com/cs/ww/en/view/101494917 **==> picture [438 x 305] intentionally omitted <==** **----- Start of picture text -----**<br> -Q<br>|<br>last modified: 9/5/2025<br>1/L1 3/L2 5/L3 A1 13 NO 23 NO 95 43 NO L+ M DI 1 DI 2 DI 3 DI 4<br>2/T1 4/T2 6/T3 A2 14 24 98 NO 96 NC 44 AQ I+ AQ U+ AQ- T1 T2<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3RW55271HA06 Page 7/7 5/30/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →