Image not available
Illustrative purposes only
3RV2031-4JA10-0BA0
Thermal Magnetic Circuit Breaker, MPCB, 3RV2, 3P, 65 kA, 400 V, 65 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type:
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 315.18 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2031-4JA10-0BA0** **Data sheet** Special type Circuit breaker size S2 for motor protection, CLASS 10 A-release 54...65 A N-release 845 A screw terminal Standard switching capacity Ambient temperature -50 °C 250 switching cycles |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S2| |**size of contactor can be combined company-specific**|S2| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|26 W| |● at AC in hot operatingstateperpole|8.7 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP00| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms Sinus| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|250| |● of auxiliarycontacts typical|250| |electrical endurance(operatingcycles)typical|250| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|65 A| |**Substance Prohibitance(day/month/year)**|04/10/2015| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|1.166 kg| |**Ambient conditions**|| Subject to change without notice © Copyright Siemens 3RV20314JA100BA0 Page 1/6 6/4/2026 |installation altitude at height above sea level maximum|2 000 m| |---|---| |**ambient temperature**|| |● duringoperation|-50 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**<br>**dependent overload release**|54 ... 65 A| |**type of voltage for main current circuit**|AC| |**operating voltage**|| |● rated value|690 V| |● rated value|20 ... 690 V| |● at AC-3 rated value maximum|690 V| |**operating frequency rated value**|50 ... 60 Hz| |**operational current rated value**|65 A| |**operational current**|| |● at AC-3 at 400 V rated value|65 A| |**operating power**|| |● at AC-3|| |— at 230 V rated value|18.5 kW| |— at 400 V rated value|30 kW| |— at 500 V rated value|45 kW| |— at 690 V rated value|55 kW| |**operating frequency**|| |● at AC-3 maximum|15 1/h| |**Auxiliary circuit**|| |**type of voltage for auxiliary and control circuit**|AC/DC| |**number of NC contacts for auxiliary contacts**|0| |**number of NO contacts for auxiliary contacts**|0| |number of CO contacts for auxiliarycontacts|0| |**Protective and monitoring functions**|| |**product function**|| |●ground fault detection|No| |●phase failure detection|Yes| |**trip class**|CLASS 10| |**design of the overload release**|thermal| |**protection function thermal overloadprotection(ANSI 49)**|Yes| |**maximum short-circuit current breaking capacity (Icu)**|| |● at AC at 240 V rated value|100 kA| |● at AC at 400 V rated value|65 kA| |● at AC at 500 V rated value|8 kA| |● at AC at 690 V rated value|4 kA| |**operating short-circuit current breaking capacity (Ics) at AC**|| |● at 240 V rated value|25 kA| |● at 400 V rated value|30 kA| |● at 500 V rated value|4 kA| |● at 690 V rated value|2 kA| |response value current of instantaneous short-circuit trip unit|845 A| |**Short-circuit protection**|| |**product function short circuitprotection**|Yes| |**design of the short-circuit trip**|magnetic| |**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**|| |● at 240 V|none required| |● at 400 V|gG 160 A| |● at 500 V|gG 125 A| Subject to change without notice © Copyright Siemens 3RV20314JA100BA0 Page 2/6 6/4/2026 |● at 690 V|gG 100 A| |---|---| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715| |**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes| |**height**|140 mm| |**width**|55 mm| |**depth**|149 mm| |**required spacing**|| |● with side-by-side mounting|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|0 mm| |● forgroundedparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— at the side|10 mm| |— downwards|50 mm| |● for liveparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|10 mm| |● forgroundedparts at 400 V|| |— downwards|50 mm| |— upwards|50 mm| |— at the side|10 mm| |● for liveparts at 400 V|| |— downwards|50 mm| |— upwards|50 mm| |— at the side|10 mm| |● forgroundedparts at 500 V|| |— downwards|50 mm| |— upwards|50 mm| |— at the side|10 mm| |● for liveparts at 500 V|| |— downwards|50 mm| |— upwards|50 mm| |— at the side|10 mm| |● forgroundedparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— at the side|10 mm| |● for liveparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— at the side|10 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| |**type of electrical connection**|| |● for main current circuit|screw-type terminals| |**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom| Subject to change without notice © Copyright Siemens 3RV20314JA100BA0 Page 3/6 6/4/2026 |**type of connectable conductor cross-sections**|||||||||| |---|---|---|---|---|---|---|---|---|---| |● for main contacts|||||||||| |— solid or stranded||2x(1 ... 35 mm²|1 ... 35 mm²), 1x(1 ... 50 mm²)||||||| |— finelystranded with core endprocessing||2x(1 ... 25 mm²|1 ... 25 mm²), 1x(1 ... 35 mm²)||||||| |**connectable conductor cross-section for main contacts**|||||||||| |● solid or stranded||1 ... 50 mm²||1 ... 50 mm²|||||| |● finelystranded with core endprocessing||1 ... 35 mm²||1 ... 35 mm²|||||| |**tightening torque**|||||||||| |● for main contacts with screw-type terminals||3 ... 4.5 N·m|||||||| |**design of screwdriver shaft**||Diameter 5 to 6 mm|||Diameter 5 to 6 mm||||| |**size of the screwdriver tip**||Pozidriv size 2|||||||| |**design of the thread of the connection screw**|||||||||| |● for main contacts||M6|||||||| |IEC 61508<br>**T1 value**<br>~~ee~~|||||||||| |● for proof test interval or service life according to IEC||10 a|||||||| |61508|||||||||| |Electrical Safety<br>**protection class IP on the front according to IEC 60529**<br>IP20<br>~~ee~~|||||||||| |**touch protection on the front according to IEC 60529**||finger-safe, for vertical contact from the front|||||||| |**Display**<br>displayversion for switchingstatus<br>Handle<br>~~Onstl~~|||||||||| |**Approvals Certificates**<br>Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>~~————~~||12.8 kg<br>~~=~~|||||||| |● global warming potential [CO2 eq] / during sales||0.477 kg|||||||| |● global warming potential [CO2 eq] / during operation||230 kg|||||||| |● global warming potential [CO2 eq] / after end of life||-3.4 kg|||||||| |● global warming potential [CO2 eq] / total||239.877 kg|||||||| |**Environment**||||**General Product Approval**|**General Product Approval**||||| |Environmental Con-|||||||||| |firmations|||||||||| |**General Product Approval**||||**Test Certificates**||||**Maritime application**|| ||VK|||Special Test Certific-<br>ate<br>~~———_ ~~||Type Test Certific-<br>ates/Test Report<br> ~~—~~|||| |**Maritime application**||||||||**other**|| |San<br>om|Regn<br>is|||®<br>@|||"|Miscellaneous<br>~~a~~|| |**other**||||**Railway**|||||| |Confirmation<br>Miscellaneous<br>~~rn~~||||Confirmation||Special Test Certific-|||| ||||||||ate||| **Further information** ~~eC‘~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 Subject to change without notice © Copyright Siemens 3RV20314JA100BA0 Page 4/6 6/4/2026 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2031-4JA10-0BA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RV2031-4JA10-0BA0 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2031-4JA10-0BA0&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2031-4JA10-0BA0 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **==> picture [203 x 225] intentionally omitted <==** Subject to change without notice © Copyright Siemens 3RV20314JA100BA0 Page 5/6 6/4/2026 **==> picture [343 x 368] intentionally omitted <==** **----- Start of picture text -----**<br> -F<br>||<br>ae<br>I> I> I><br>last modified: 5/5/2026 G<br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3RV20314JA100BA0 Page 6/6 6/4/2026
Updated at March 30, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →