Image not available
Illustrative purposes only
3RV20214PA10
Thermal Magnetic Circuit Breaker, Size S0, SIRIUS 3RV2 Series, 36 A, 3 Pole, 690 V, DIN Rail
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- No. of Poles: 3 Pole
- Product Range: SIRIUS 3RV2 Series
- Current Rating: 36A
- Voltage Rating VAC: 690V
- Voltage Rating VDC: -
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 312.79 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2021-4PA10**
**Data sheet**
Circuit breaker size S0 for motor protection, CLASS 10 A-release 30...36 A N- release 432 A screw terminal Standard switching capacity
|**product brand name**|SIRIUS|
|---|---|
|**product designation**|Circuit breaker|
|**design of theproduct**|For motorprotection|
|**product type designation**|3RV2|
|**General technical data**||
|**Product equipment of circuit breaker for motor protection**|Yes|
|**complete unit withprotection device**||
|**size of the circuit-breaker**|S0|
|**size of contactor can be combined company-specific**|S00, S0|
|product function disconnector functionality|Yes|
|product extension auxiliaryswitch|Yes|
|**power loss[W] for rated value of the current**||
|● at AC in hot operatingstate|16.25 W|
|● at AC in hot operatingstateperpole|5.4 W|
|**type of calculation ofpower loss current-dependent**|quadratic|
|insulation voltage with degree ofpollution 3 at AC rated value|690 V|
|**surge voltage resistance rated value**|6 kV|
|**maximumpermissible voltage forprotective separation**||
|● in networks with ungrounded star point between main and|400 V|
|auxiliarycircuit||
|● in networks with grounded star point between main and|400 V|
|auxiliarycircuit||
|**protection class IP**||
|● on the front accordingto IEC 60529|IP20|
|● on the front|IP20|
|● of the terminal|IP20|
|**shock resistance according to IEC 60068-2-27**|25g/ 11 ms|
|**mechanical service life(operating cycles)**||
|● of the main contacts typical|100 000|
|● of auxiliarycontacts typical|100 000|
|electrical endurance(operatingcycles)typical|100 000|
|**reference code according to IEC 81346-2**|Q|
|**continuous current rated value**|36 A|
|**Substance Prohibitance(day/month/year)**|10/01/2009|
|**Net Weight**|381g|
|**Ambient conditions**||
|installation altitude at height above sea level maximum|2 000 m|
Subject to change without notice © Copyright Siemens
3RV20214PA10 Page 1/7
5/29/2026
|**ambient temperature**||
|---|---|
|● duringoperation|-20 ... +40 °C|
|● duringstorage|-50 ... +80 °C|
|● duringtransport|-50 ... +80 °C|
|**temperature compensation**|-20 ... +60 °C|
|relative humidityduringoperation|10 ... 95 %|
|**Main circuit**||
|**number ofpoles for main current circuit**|3|
|**adjustable current response value current of the current-**<br>**dependent overload release**|30 ... 36 A|
|**type of voltage for main current circuit**|AC|
|**operating voltage**||
|● rated value|690 V|
|● rated value|20 ... 690 V|
|● at AC-3 rated value maximum|690 V|
|**operating frequency rated value**|50 ... 60 Hz|
|**operational current rated value**|36 A|
|**operational current**||
|● at AC-3 at 400 V rated value|36 A|
|**operating power**||
|● at AC-3||
|— at 230 V rated value|7.5 kW|
|— at 400 V rated value|18.5 kW|
|— at 500 V rated value|22 kW|
|— at 690 V rated value|30 kW|
|**operating frequency**||
|● at AC-3 maximum|15 1/h|
|**Auxiliary circuit**||
|**type of voltage for auxiliary and control circuit**|AC/DC|
|**number of NC contacts for auxiliary contacts**|0|
|**number of NO contacts for auxiliary contacts**|0|
|number of CO contacts for auxiliarycontacts|0|
|**Protective and monitoring functions**||
|**product function**||
|●ground fault detection|No|
|●phase failure detection|Yes|
|**trip class**|CLASS 10|
|**design of the overload release**|thermal|
|**protection function thermal overloadprotection(ANSI 49)**|Yes|
|**maximum short-circuit current breaking capacity (Icu)**||
|● at AC at 240 V rated value|100 kA|
|● at AC at 400 V rated value|20 kA|
|● at AC at 500 V rated value|6 kA|
|● at AC at 690 V rated value|3 kA|
|**operating short-circuit current breaking capacity (Ics) at AC**||
|● at 240 V rated value|100 kA|
|● at 400 V rated value|10 kA|
|● at 500 V rated value|3 kA|
|● at 690 V rated value|2 kA|
|response value current of instantaneous short-circuit trip unit|432 A|
|**UL/CSA ratings**||
|**full-load current(FLA) for 3-phase AC motor**||
|● at 480 V rated value|36 A|
|● at 600 V rated value|36 A|
|**yielded mechanicalperformance[hp]**||
|● for single-phase AC motor||
|— at 110/120 V rated value|3 hp|
|— at 230 V rated value|5 hp|
|● for 3-phase AC motor||
Subject to change without notice © Copyright Siemens
3RV20214PA10 Page 2/7
5/29/2026
||— at 200/208 V rated value|10 hp||
|---|---|---|---|
||— at 220/230 V rated value|10 hp||
||— at 460/480 V rated value|25 hp||
||**UL File Number(CCN)**|E47705(NLRV, NLRV7)||
||**Short-circuit protection**|||
||**product function short circuitprotection**|Yes||
||**design of the short-circuit trip**|magnetic||
||**design of the fuse link for IT network for short-circuit**<br>**protection of the main circuit**|||
||● at 400 V|gG 63 A||
||● at 500 V|gG 63 A||
||● at 690 V|gG 63 A||
||certificate of suitabilityaccordingto ATEX directive 2014/34/EU|DMT 02 ATEX F 001||
||**type of protection according to ATEX directive 2014/34/EU**|Ex II(2)GD||
||**Installation/ mounting/ dimensions**|||
||**mounting position**|any||
||**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715||
||**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes||
||**height**|97 mm||
||**width**|45 mm||
||**depth**|97 mm||
||**required spacing**|||
||● with side-by-side mounting|||
||— forwards|0 mm||
||— backwards|0 mm||
||— upwards|70 mm||
||— downwards|70 mm||
||— at the side|9 mm||
||● forgroundedparts|||
||— forwards|0 mm||
||— backwards|0 mm||
||— upwards|70 mm||
||— at the side|30 mm||
||— downwards|70 mm||
||● for liveparts|||
||— forwards|0 mm||
||— backwards|0 mm||
||— upwards|70 mm||
||— downwards|70 mm||
||— at the side|30 mm||
||● forgroundedparts at 400 V|||
||— downwards|30 mm||
||— upwards|30 mm||
||— at the side|9 mm||
||● for liveparts at 400 V|||
||— downwards|30 mm||
||— upwards|30 mm||
||— at the side|9 mm||
||● forgroundedparts at 500 V|||
||— downwards|30 mm||
||— upwards|30 mm||
||— at the side|9 mm||
||● for liveparts at 500 V|||
||— downwards|30 mm||
||— upwards|30 mm||
||— at the side|9 mm||
||● forgroundedparts at 690 V|||
||— downwards|70 mm||
Subject to change without notice © Copyright Siemens
3RV20214PA10 Page 3/7
5/29/2026
|— upwards|70 mm|
|---|---|
|— backwards|0 mm|
|— at the side|30 mm|
|— forwards|0 mm|
|● for liveparts at 690 V||
|— downwards|70 mm|
|— upwards|70 mm|
|— backwards|0 mm|
|— at the side|30 mm|
|— forwards|0 mm|
|**Connections/ Terminals**||
|**product component removable terminal for auxiliary and**<br>**control circuit**|No|
|**type of electrical connection**||
|● for main current circuit|screw-type terminals|
|**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom|
|**type of connectable conductor cross-sections**||
|● for main contacts||
|— solid or stranded|2x(1 ... 2.5 mm²), 2x(2.5 ... 10 mm²)|
|— finelystranded with core endprocessing|2x(1 ... 2.5 mm²), 2x(2.5 ... 6 mm²), 1x 10 mm²|
|● for AWG cables for main contacts|2x(16 ... 12), 2x(14 ... 8)|
|**connectable conductor cross-section for main contacts**||
|● solid or stranded|1 ... 10 mm²|
|● finelystranded with core endprocessing|1 ... 10 mm²|
|**AWG number as coded connectable conductor cross**<br>**section for main contacts**|16 ... 8|
|**tightening torque**||
|● for main contacts with screw-type terminals|2 ... 2.5 N·m|
|**design of screwdriver shaft**|Diameter 5 to 6 mm|
|**size of the screwdriver tip**|Pozidriv size 2|
|**design of the thread of the connection screw**||
|● for main contacts|M4|
|**Safety related data**||
|product function suitable for safetyfunction|Yes|
|**suitability for use**||
|● safety-related switchingon|No|
|● safety-related switchingOFF|Yes|
|**service life maximum**|10 a|
|**test wear-related service life necessary**|Yes|
|**proportion of dangerous failures**||
|● with low demand rate accordingto SN 31920|40 %|
|● with high demand rate accordingto SN 31920|50 %|
|**B10 value with high demand rate according to SN 31920**|5 000|
|**failure rate [FIT] with low demand rate according to SN**<br>**31920**|50 FIT|
|ISO 13849||
|**device type according to ISO 13849-1**|3|
|**overdimensioning according to ISO 13849-2 necessary**|Yes|
|IEC 61508||
|**safety device type according to IEC 61508-2**|Type A|
|**T1 value**||
|● for proof test interval or service life according to IEC<br>61508|10 a|
|Electrical Safety||
|**protection class IP on the front according to IEC 60529**|IP20|
|**touch protection on the front according to IEC 60529**|finger-safe, for vertical contact from the front|
|**Display**||
|displayversion for switchingstatus|Handle|
|**Approvals Certificates**||
Subject to change without notice © Copyright Siemens
3RV20214PA10 Page 4/7
5/29/2026
**==> picture [510 x 701] intentionally omitted <==**
**----- Start of picture text -----**<br>
ee Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing 2.68 kg<br>● global warming potential [CO2 eq] / during sales 0.143 kg<br>● global warming potential [CO2 eq] / during operation 72.7 kg<br>● global warming potential [CO2 eq] / after end of life -0.445 kg<br>● global warming potential [CO2 eq] / total 75.078 kg<br>Environment General Product Approval<br>Environmental Con-<br>firmations<br>sp e Se o {[e<br>For use in hazard-<br>General Product Approval ous locations<br>For use in hazard-<br>ous locations Test Certificates Maritime application<br>- -<br>Special Test Certific Type Test Certific<br>ate ates/Test Report<br>eo —~——e @ &<br>Maritime application other<br>Confirmation Miscellaneous Confirmation<br>: —==<br>other Railway<br>Miscellaneous Confirmation Special Test Certific-<br>ate<br>— eg — —<br>e Further information C<br>Information on the packaging<br>https://support.industry.siemens.com/cs/ww/en/view/109813875<br>Information for data generation and storage<br>https://support.industry.siemens.com/cs/ww/en/view/109995012<br>Information- and Downloadcenter (Catalogs, Brochures,…)<br>https://www.siemens.com/ic10<br>Industry Mall (Online ordering system)<br>https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2021-4PA10<br>Service&Support (Manuals, Certificates, Characteristics, FAQs,...)<br>https://support.industry.siemens.com/cs/ww/en/ps/3RV2021-4PA10<br>Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)<br>https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2021-4PA10&lang=en<br>Cax online generator<br>https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2021-4PA10<br>Characteristic curves<br>https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no><br>**----- End of picture text -----**<br>
Subject to change without notice © Copyright Siemens
3RV20214PA10 Page 5/7
5/29/2026
**==> picture [511 x 718] intentionally omitted <==**
Subject to change without notice © Copyright Siemens
3RV20214PA10 Page 6/7
5/29/2026
**==> picture [343 x 368] intentionally omitted <==**
**----- Start of picture text -----**<br>
-F<br>||<br>ae<br>I> I> I><br>last modified: 5/5/2026 G<br>1/L1 3/L2 5/L3<br>/T1 /T2 /T3<br>2 4 6<br>**----- End of picture text -----**<br>
Subject to change without notice © Copyright Siemens
3RV20214PA10 Page 7/7
5/29/2026
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →