Image not available
Illustrative purposes only
3RV2021-1AA20
Thermal Magnetic Circuit Breaker, MPCB, 3RV2, 3P, 100 kA, 400 V, 1.6 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Thermal Magnetic Circuit Breakers
- Product Range: SIRIUS 3RV2 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 78.91 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RV2021-1AA20** **Data sheet** Circuit breaker size S0 for motor protection, CLASS 10 A-release 1.1...1.6 A N- release 21 A Spring-type terminal Standard switching capacity |**product brand name**|SIRIUS| |---|---| |**product designation**|Circuit breaker| |**design of theproduct**|For motorprotection| |**product type designation**|3RV2| |**General technical data**|| |**Product equipment of circuit breaker for motor protection**|Yes| |**complete unit withprotection device**|| |**size of the circuit-breaker**|S0| |**size of contactor can be combined company-specific**|S00, S0| |product function disconnector functionality|Yes| |product extension auxiliaryswitch|Yes| |**power loss[W] for rated value of the current**|| |● at AC in hot operatingstate|7.25 W| |● at AC in hot operatingstateperpole|2.4 W| |**type of calculation ofpower loss current-dependent**|quadratic| |insulation voltage with degree ofpollution 3 at AC rated value|690 V| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● in networks with ungrounded star point between main and|400 V| |auxiliarycircuit|| |● in networks with grounded star point between main and|400 V| |auxiliarycircuit|| |**protection class IP**|| |● on the front accordingto IEC 60529|IP20| |● on the front|IP20| |● of the terminal|IP20| |**shock resistance according to IEC 60068-2-27**|25g/ 11 ms| |**mechanical service life(operating cycles)**|| |● of the main contacts typical|100 000| |● of auxiliarycontacts typical|100 000| |electrical endurance(operatingcycles)typical|100 000| |**reference code according to IEC 81346-2**|Q| |**continuous current rated value**|1.6 A| |**Substance Prohibitance(day/month/year)**|10/01/2009| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|406g| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-20 ... +60 °C| |● duringstorage|-50 ... +80 °C| |● duringtransport|-50 ... +80 °C| |**temperature compensation**|-20 ... +60 °C| |relative humidityduringoperation|10 ... 95 %| |**Main circuit**|| |**number ofpoles for main current circuit**|3| |**adjustable current response value current of the current-**|1.1 ... 1.6 A| |**dependent overload release**|| |**type of voltage for main current circuit**|AC| Subject to change without notice © Copyright Siemens 3RV20211AA20 Page 1/6 5/31/2026 ||**operating voltage**||| |---|---|---|---| ||● rated value|690 V|| ||● rated value|20 ... 690 V|| ||● at AC-3 rated value maximum|690 V|| ||● at AC-3e rated value maximum|690 V|| ||**operating frequency rated value**|50 ... 60 Hz|| ||**operational current rated value**|1.6 A|| ||**operational current**||| ||● at AC-3 at 400 V rated value|1.6 A|| ||● at AC-3e at 400 V rated value|1.6 A|| ||**operating power**||| ||● at AC-3||| ||— at 230 V rated value|0.3 kW|| ||— at 400 V rated value|0.6 kW|| ||— at 500 V rated value|0.8 kW|| ||— at 690 V rated value|1.1 kW|| ||● at AC-3e||| ||— at 230 V rated value|0.3 kW|| ||— at 400 V rated value|0.6 kW|| ||— at 500 V rated value|0.8 kW|| ||— at 690 V rated value|1.1 kW|| ||**operating frequency**||| ||● at AC-3 maximum|15 1/h|| ||● at AC-3e maximum|15 1/h|| ||**Auxiliary circuit**||| ||**type of voltage for auxiliary and control circuit**|AC/DC|| ||**number of NC contacts for auxiliary contacts**|0|| ||**number of NO contacts for auxiliary contacts**|0|| ||number of CO contacts for auxiliarycontacts|0|| ||**Protective and monitoring functions**||| ||**product function**||| ||●ground fault detection|No|| ||●phase failure detection|Yes|| ||**trip class**|CLASS 10|| ||**design of the overload release**|thermal|| ||**protection function thermal overloadprotection(ANSI 49)**|Yes|| ||**maximum short-circuit current breaking capacity (Icu)**||| ||● at AC at 240 V rated value|100 kA|| ||● at AC at 400 V rated value|100 kA|| ||● at AC at 500 V rated value|100 kA|| ||● at AC at 690 V rated value|100 kA|| ||**operating short-circuit current breaking capacity (Ics) at AC**||| ||● at 240 V rated value|100 kA|| ||● at 400 V rated value|100 kA|| ||● at 500 V rated value|100 kA|| ||● at 690 V rated value|100 kA|| ||response value current of instantaneous short-circuit trip unit|21 A|| ||**UL/CSA ratings**||| ||**full-load current(FLA) for 3-phase AC motor**||| ||● at 480 V rated value|1.6 A|| ||● at 600 V rated value|1.6 A|| ||**yielded mechanicalperformance[hp]**||| ||● for single-phase AC motor||| ||— at 230 V rated value|0.1 hp|| ||● for 3-phase AC motor||| ||— at 460/480 V rated value|1 hp|| ||— at 575/600 V rated value|0.8 hp|| ||**UL File Number(CCN)**|E47705(NLRV, NLRV7), E156943(NKJH, NKJH7)|| ||**Short-circuit protection**||| Subject to change without notice © Copyright Siemens 3RV20211AA20 Page 2/6 5/31/2026 |**product function short circuitprotection**|Yes| |---|---| |**design of the short-circuit trip**|magnetic| |certificate of suitabilityaccordingto ATEX directive 2014/34/EU|DMT 02 ATEX F 001| |**type of protection according to ATEX directive 2014/34/EU**|Ex II(2)GD| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mountingonto 35 mm DIN rail accordingto DIN EN 60715| |**Mounting method of circuit breaker for Transformer**<br>**protection, Generator protection and system protection**<br>**optional standard bar mounting**|Yes| |**height**|119 mm| |**width**|45 mm| |**depth**|97 mm| |**required spacing**|| |● with side-by-side mounting|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|0 mm| |● forgroundedparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— at the side|30 mm| |— downwards|50 mm| |● for liveparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|50 mm| |— downwards|50 mm| |— at the side|30 mm| |● forgroundedparts at 400 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● for liveparts at 400 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● forgroundedparts at 500 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● for liveparts at 500 V|| |— downwards|30 mm| |— upwards|30 mm| |— at the side|9 mm| |● forgroundedparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|30 mm| |— forwards|0 mm| |● for liveparts at 690 V|| |— downwards|50 mm| |— upwards|50 mm| |— backwards|0 mm| |— at the side|30 mm| Subject to change without notice © Copyright Siemens 3RV20211AA20 Page 3/6 5/31/2026 |— forwards|0 mm| |---|---| |**Connections/ Terminals**<br>~~ee~~|| |**product component removable terminal for auxiliary and**<br>**control circuit**<br>~~ee~~|No<br>~~ee~~| |**type of electrical connection**|| |● for main current circuit|spring-loaded terminals| |**arrangement of electrical connectors for main current**<br>**circuit**|Top and bottom| |**type of connectable conductor cross-sections**|| |● for main contacts|| |— solid or stranded|2x(1 ... 10 mm²)| |— finelystranded with core endprocessing|2x(1 ... 6 mm²)| |— finelystranded without core endprocessing|2x(1 ... 6 mm²)| |● for AWG cables for main contacts|2x(18 ... 8)| |**connectable conductor cross-section for main contacts**|| |● solid or stranded|1 ... 10 mm²| |● finelystranded with core endprocessing|1 ... 6 mm²| |● finelystranded without core endprocessing|1 ... 6 mm²| |**AWG number as coded connectable conductor cross**<br>**section for main contacts**|18 ... 8| |**design of screwdriver shaft**|Diameter 3 mm| |**size of the screwdriver tip**|3,0 x 0,5 mm| |**Safety related data**<br>~~———————————————~~|| |product function suitable for safetyfunction<br>~~———————————————~~|Yes<br>~~———————————————~~| |**suitability for use**<br>~~———————————————~~|~~———————————————~~| |● safety-related switchingon|No| |● safety-related switchingOFF|Yes| |**service life maximum**|10 a| |**test wear-related service life necessary**|Yes| |**proportion of dangerous failures**|| |● with low demand rate accordingto SN 31920|40 %| |● with high demand rate accordingto SN 31920|50 %| |**B10 value with high demand rate according to SN 31920**|5 000| |**failure rate [FIT] with low demand rate according to SN**<br>**31920**<br>~~Sn~~|50 FIT<br>~~Sn~~| |ISO 13849<br>~~Sn~~|| |**device type according to ISO 13849-1**<br>~~Sn~~|3<br>~~Sn~~| |**overdimensioning according to ISO 13849-2 necessary**<br>~~Sn~~<br>~~EE~~|Yes<br>~~Sn~~| |IEC 61508<br>~~EE~~|| |**safety device type according to IEC 61508-2**<br>~~EE~~|Type A| |**T1 value**<br>~~EE~~|| |● for proof test interval or service life according to IEC<br>61508<br>~~EE~~|10 a| |Electrical Safety<br>~~EE~~|| |**protection class IP on the front according to IEC 60529**<br>~~EE~~|IP20| |**touch protection on the front according to IEC 60529**<br>~~EE~~|finger-safe, for vertical contact from the front| |**Display**<br>~~a~~|| |displayversion for switchingstatus<br>~~a~~|Handle<br>~~a~~| |**Approvals Certificates**<br>~~a~~|| |Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>2.68 kg<br>● global warming potential [CO2 eq] / during sales<br>0.143 kg<br>● global warming potential [CO2 eq] / during operation<br>72.7 kg<br>● global warming potential [CO2 eq] / after end of life<br>-0.445 kg<br>● global warming potential [CO2 eq] / total<br>75.078 kg<br>**Environment**<br>**General Product Approval**<br>~~a~~|| Subject to change without notice © Copyright Siemens 3RV20211AA20 Page 4/6 5/31/2026 **==> picture [510 x 520] intentionally omitted <==** **----- Start of picture text -----**<br> General Product Approval<br>For use in hazardous locations Test Certificates Maritime application<br>- -<br>Special Test Certific Type Test Certific<br>ate ates/Test Report<br>Maritime application other<br>= in Miscellaneous Confirmation<br>other Railway<br>Miscellaneous Confirmation Special Test Certific-<br>ate<br>QC PASS<br>—_ a<br>e Further information e<br>Information on the packaging<br>https://support.industry.siemens.com/cs/ww/en/view/109813875<br>Information for data generation and storage<br>https://support.industry.siemens.com/cs/ww/en/view/109995012<br>Information- and Downloadcenter (Catalogs, Brochures,…)<br>https://www.siemens.com/ic10<br>Industry Mall (Online ordering system)<br>https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2021-1AA20<br>Service&Support (Manuals, Certificates, Characteristics, FAQs,...)<br>https://support.industry.siemens.com/cs/ww/en/ps/3RV2021-1AA20<br>Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)<br>https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2021-1AA20&lang=en<br>Cax online generator<br>https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2021-1AA20<br>Characteristic curves<br>https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no><br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3RV20211AA20 Page 5/6 5/31/2026 **last modified:** **==> picture [30 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 5/5/2026<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3RV20211AA20 Page 6/6 5/31/2026
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →