3RP2505-2BW30
Time Delay Relay, 240 VDC, 0.05 s, 100 h, 3RP Series, 2CO, DIN Rail
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Time Delay Relays - Electromechanical
- Product Range: SIRIUS 3RP25 Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 171.7 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RP2505-2BW30** **Data sheet** Timing relay, Multifunction 2 change-over contacts, 27 functions 7 time ranges (0.05 s...100 h) 12-240 V AC/DC at 50/60 Hz AC with LED Spring-type terminal (push-in) |Timing relay, Multifunction 2 change-over contacts, 27 functions 7 time ranges<br>(0.05 s...100 h) 12-240 V AC/DC at 50/60 Hz AC with LED Spring-type terminal<br>(push-in)<br>**product brand name**<br>SIRIUS<br>**product designation**<br>timingrelay<br>**design of theproduct**<br>27 functions<br>**product type designation**<br>3RP25<br>**General technical data**<br>**product featureprotective coating onprinted-circuit board**<br>No<br>**product component**<br>● relayoutput<br>Yes<br>● semi-conductor output<br>No<br>**product extension required remote control**<br>No<br>**product extension optional remote control**<br>No<br>**power loss[W] maximum**<br>2 W<br>insulation voltage for overvoltage category III according to IEC<br>60664 with degree ofpollution 3 rated value<br>300 V<br>**test voltage for isolation test**<br>2.5 kV<br>**degree ofpollution**<br>3<br>**surge voltage resistance rated value**<br>4 000 V<br>**shock resistance according to IEC 60068-2-27**<br>11g/ 15 ms<br>**vibration resistance according to IEC 60068-2-6**<br>10 ... 55 Hz / 0.35 mm<br>**mechanical service life(operating cycles) typical**<br>10 000 000<br>electrical endurance(operatingcycles)at AC-15 at 230 V typical<br>100 000<br>**adjustable time**<br>0.05 s ... 100 h<br>**relative setting accuracy relating to full-scale value**<br>5 %; +/-<br>**thermal current**<br>5 A<br>**ONperiod/maximum minimum**<br>35 ms<br>**recovery time**<br>250 ms<br>**reference code according to IEC 81346-2**<br>K<br>**relative repeat accuracy**<br>1 %; +/-<br>**influence of the surrounding temperature**<br>1% in the whole temperature range to the set runtime<br>**power supply influence**<br>1% in the whole voltage range to the set runtime<br>**Substance Prohibitance(day/month/year)**<br>09/12/2014<br>**SVHC substance name**<br>Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1<br>**Net Weight**<br>0.159 kg<br>**Control circuit/ Control**<br>**type of voltage of the control supply voltage**<br>AC/DC<br>**control supply voltage at AC**|Timing relay, Multifunction 2 change-over contacts, 27 functions 7 time ranges<br>(0.05 s...100 h) 12-240 V AC/DC at 50/60 Hz AC with LED Spring-type terminal<br>(push-in)|| |---|---|---| ||SIRIUS|| ||timingrelay|| ||27 functions|| ||3RP25|| ||AC/DC|| |||| Subject to change without notice © Copyright Siemens 3RP25052BW30 Page 1/6 6/2/2026 |● at 50 Hz rated value|12 ... 240 V| |---|---| |● at 60 Hz rated value|12 ... 240 V| |**control supply voltage 1 at AC**|| |● at 50 Hz|12 ... 240 V| |● at 60 Hz|12 ... 240 V| |**control supply voltage frequency 1**|50 ... 60 Hz| |**control supply voltage at DC rated value**|12 ... 240 V| |**control supply voltage 1 at DC**|12 ... 240 V| |**operating range factor control supply voltage rated value at**<br>**DC**|| |● initial value|0.8| |● full-scale value|1.1| |**operating range factor control supply voltage rated value at**<br>**AC at 50 Hz**|| |● initial value|0.8| |● full-scale value|1.1| |**operating range factor control supply voltage rated value at**<br>**AC at 60 Hz**|| |● initial value|0.8| |● full-scale value|1.1| |**inrush currentpeak**|| |● at 24 V|0.3 A| |● at 240 V|5 A| |**duration of inrush currentpeak**|| |● at 24 V|0.3 ms| |● at 240 V|0.5 ms| |**Switching Function**|| |**switching function**|| |● ON-delay|Yes| |● ON-delay/instantaneous contact|Yes| |●passingmake contact|Yes| |●passingmake contact/instantaneous contact|Yes| |● OFF delay|No| |**switching function**|| |● flashingsymmetricallywith interval start/instantaneous|Yes| |● flashingsymmetricallywith interval start|Yes| |● flashingsymmetricallywithpulse start/instantaneous|Yes| |● flashingsymmetricallywithpulse start|Yes| |● flashingasymmetricallywith interval start|No| |● flashingasymmetricallywithpulse start|No| |**switching function**|| |● star-delta circuit with delaytime|No| |● star-delta circuit|Yes| |**switching function with control signal**|| |● additive ON-delay|Yes| |●passingbreak contact|Yes| |●passingbreak contact/instantaneous|Yes| |● OFF delay|Yes| |● OFF delay/instantaneous|Yes| |●pulse delayed|Yes| |●pulse delayed/instantaneous|Yes| |●pulse-shaping|Yes| |●pulse-shaping/instantaneous|Yes| |● additive ON-delay/instantaneous|Yes| |● ON-delay/OFF-delay/instantaneous|Yes| |●passingmake contact|Yes| |●passingmake contact/instantaneous contact|Yes| |**switching function of interval relay with control signal**|| |● retrotriggerable with deactivated control<br>signal/instantaneous contact|Yes| Subject to change without notice © Copyright Siemens 3RP25052BW30 Page 2/6 6/2/2026 |● retrotriggerable with switched-on control signal|Yes| |---|---| |● retrotriggerable with switched-on control<br>signal/instantaneous contact|Yes| |● retriggerable with deactivated control signal|Yes| |**design of the control terminal non-floating**|Yes| |**Short-circuit protection**|| |design of the fuse link for short-circuit protection of the auxiliary<br>switch required|fuse gL/gG: 4 A| |**Auxiliary circuit**|| |**material of switching contacts**|AgSnO2| |**number of NC contacts**|| |● delayed switching|0| |● instantaneous contact|0| |**number of NO contacts**|| |● delayed switching|0| |● instantaneous contact|0| |**number of CO contacts**|| |● delayed switching|2| |● instantaneous contact|0| |**operational current of auxiliary contacts at AC-15**|| |● at 24 V|3 A| |● at 250 V|3 A| |**operational current of auxiliary contacts at DC-13**|| |● at 24 V|1 A| |● at 125 V|0.2 A| |● at 250 V|0.1 A| |**operating frequency with 3RT2 contactor maximum**|5 000 1/h| |**contact reliability of auxiliary contacts**|one incorrect switching operation of 100 million switching operations (17 V, 5<br>mA)| |**contact rating of auxiliary contacts according to UL**|R300 / B300| |**switching capacity current with inductive load**|0.01 ... 3 A| |**Inputs/ Outputs**|| |**product function**|| |● at the relayoutputs switchover delayed/without delay|Yes| |● non-volatile|No| |**ampacity of the output relay at DC-13**|| |● at 24 V|1 A| |● at 125 V|0.2 A| |**Electromagnetic compatibility**|| |EMC emitted interference accordingto IEC 61812-1|ambience A(industrial sector)| |EMC immunityaccordingto IEC 61812-1|corresponds to degree of severity3| |**conducted interference**|| |● due to burst accordingto IEC 61000-4-4|2 kV network connection / 1 kV control connection| |● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV| |● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV| |**field-based interference according to IEC 61000-4-3**|10 V/m| |**electrostatic discharge according to IEC 61000-4-2**|4 kV contact discharge / 8 kV air discharge| |**Safety related data**|| |categoryaccordingto EN 954-1|none| |Electrical Safety|| |**protection class IP on the front according to IEC 60529**|IP20| |**type of insulation**|Basic insulation| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|Yes| |**type of electrical connection**|spring-loaded terminal(push-in)| |● for auxiliaryand control circuit|spring-loaded terminals(push-in)| |**type of connectable conductor cross-sections**|| |● solid|1x (0.5 ... 4 mm²)| Subject to change without notice © Copyright Siemens 3RP25052BW30 Page 3/6 6/2/2026 |● finelystranded with core endprocessing|● finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²)| |---|---|---| |● finelystranded without core endprocessing||0.5 ... 4 mm²| |● for AWG cables solid||1x(20 ... 12)| |● for AWG cables stranded||20 ... 12| |**connectable conductor cross-section**||| |● solid||0.5 ... 4 mm²| |● finelystranded with core endprocessing||0.5 ... 2.5 mm²| |● finelystranded without core endprocessing||0.5 ... 4 mm²| |**AWG number as coded connectable conductor cross**<br>**section**||| |● solid||20 ... 12| |● stranded||20 ... 12| |**Installation/ mounting/ dimensions**<br>~~ee~~||| |**mounting position**<br>~~ee~~||any<br>~~ee~~| |**fastening method**||screw and snap-on mountingonto 35 mm DIN rail| |**height**||100 mm| |**width**||22.5 mm| |**depth**||90 mm| |**required spacing**||| |● with side-by-side mounting||| |— forwards||0 mm| |— backwards||0 mm| |— upwards||0 mm| |— downwards||0 mm| |— at the side||0 mm| |● forgroundedparts||| |— forwards||0 mm| |— backwards||0 mm| |— upwards||0 mm| |— at the side||0 mm| |— downwards||0 mm| |● for liveparts||| |— forwards||0 mm| |— backwards||0 mm| |— upwards||0 mm| |— downwards||0 mm| |— at the side||0 mm| |**Ambient conditions**<br>~~ee~~||| |installation altitude at height above sea level maximum<br>~~ee~~||2 000 m<br>~~ee~~| |**ambient temperature**||| |● duringoperation||-25 ... +60 °C| |● duringstorage||-40 ... +85 °C| |● duringtransport||-40 ... +85 °C| |relative humidityduringoperation||10 ... 95 %| |**Approvals Certificates**<br>~~ee~~||| |**Environment**<br>~~ee~~|**General Product Approval**<br>~~ee~~|| Subject to change without notice © Copyright Siemens 3RP25052BW30 Page 4/6 6/2/2026 **Maritime application** **other** Confirmation **Railway** Confirmation **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RP2505-2BW30 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RP2505-2BW30 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RP2505-2BW30 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RP2505-2BW30&lang=en Subject to change without notice © Copyright Siemens 3RP25052BW30 Page 5/6 6/2/2026 **==> picture [409 x 356] intentionally omitted <==** **----- Start of picture text -----**<br> -K<br>M<br>last modified: 5/29/2026 G<br>C<br>C<br>A1 B1 15 21/25<br>A2 A2 CN ON CN ON<br>16 18 22/26 24/28<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 3RP25052BW30 Page 6/6 6/2/2026
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →