Image not available
Illustrative purposes only
3320125000
AC/DC Power Supply, Medical, 1 Output, 60 W, 12 VDC, 5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MASCOT
- Product type: AC / DC External Plug In Adaptor Power Supplies
- SVHC: No SVHC (10-Jun-2022)
- Plug Type: Mains Plug Sold Separately
- Product Range: 3320 Series
- No. of Outputs: 1 Output
- Output Connector: 2.1mm / 2.5mm Barrel Plug
- Output Power Max: 60W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 55.86 € |
| Current stock | 10+ |
| Lead time | 30 days |
PO Box 177 ● 1601 Fredrikstad NORWAY ● sales@mascot.no ● www.mascot.no
## Model 3320
## 60 W max out • 90-264 VAC input
Universal input voltage (90-264VAC)
- Fixed output voltages Short circuit proof ECO-design compliance:
CoC Tier 2, DoE level VI, CEC, MEPS
Approvals:
- Medically certified
Safety: EN 60601-1 ed. 3.1 EMC: EN 60601-1-2 ed. 4
- UL approved
Custom specifications on request:
## Available versions
5V / 8A 6V / 6,66A 7,5V / 7A 9V / 6A 12V / 5A 15V / 4A 18V / 3,33A 24V / 2,5A 36V / 1,66A
Output voltage, connectors, cords, logo print, housing/open frame/IP rating and certificates. For more information: custom design info sheet
Notes: Plug-in/desktop unit 90-264V Exchangeable AC and DC plugs Order plugs and mains cord separately
MASCOT POWER SUPPLIES DATE 03.11.21
SPECIFICATIONS FOR TYPE 3320 Power Supply
PAGE
1 (1)
**==> picture [499 x 279] intentionally omitted <==**
**----- Start of picture text -----**<br>
MASCOT TYPE 3320:<br>Input voltage: 90 -264VAC | 90-264VAC | 90-264VAC | 90-264VAC | 90-264VAC | 90-264VAC | 90-264VAC | 90-264VAC | 90-264VAC<br>47 - 63Hz 47 - 63Hz 47 - 63Hz 47 - 63Hz 47 - 63Hz 47 - 63Hz 47 - 63Hz 47 - 63Hz 47 - 63Hz<br>Output voltage: 5V + 3% 6V + 3% 7.5V + 3% QV + 3% 12V +3% 15V + 3% 18V + 3% 24V + 3% 36V + 3%<br>52.5W<br>[Min.outputcurent www www<br>Load regulation (0 - 100% load. Measured on pcb):<br>Mains regulation: (Mains variation: 90 - 264V, 100% load<br>Efficiency (at 100% load, 230V) approx.<br>Standby power: Input voltage 230VAC <0.075W <0.075W <0.15W <0.15W <0.15W <0.15W <0.15W <0.15W <0.15W<br>y Power: Input voltage 115VAC <0.075W <0.075W <0.15W <0.15W <0.15W <0.15W <0.15W<br>Average efficiency at 100%, 75% | Input voltage 230VAC 720.6%<br>and 25% load Input voltage 115VAC 287.3% >88.6%<br>Efficiency level VI:<br>Overshoot (90 - 10% load variation): < 200mV < 200mV < 200mV < 200mV < 200mV < 200mv < 200mV < 200mV < 200mV<br>PHolduptime:Undershoot 10 - 90% load variation):|Measured on pcb ome< 250mV | <tts 250mV | <tts 250m | <mas 250mV | < 250mV>s0ms | < 250mV>8ms | <10s 250mV | <>t0ms 250mV | <>i0ms 250mV _ |<br>Temperature range: “Operating: -20 to +40°C<br>*With derating: +60°C<br>*Storage: -25 to +85°C<br>[Dering {SWC over 40°C<br>IEC 60601-19% / IEC 62368-1<br>Insulation class: Class Il<br>Insulation voltage: Primary — secondary: 4000VAC / 5700VDC<br>EMC standards: EMC med. EN 60601-1-2_/ Emission EN 61000-6-3_/ Immunity EN 61000-6-1<br>IPax<br>Linputterminl 2-pins 1EC320 C8 connector<br>Output terminals: Cord with/without plug. Exchangeable plugs available.<br>131 * 67.5 x 36mm<br>[weight<br>**----- End of picture text -----**<br>
## Standard output cordsets
|||||Length (M)||
|---|---|---|---|---|---|
|5V *ov * 7,5V *9¥V|131616|Openends|14|0.75|EMI core, OD:5.4mm@<br>UL1185|
||131581||||EMI core, UL1185|
|15V*18V*24V|131514|Femaleconn|18|ED|Coax w. EM core<br>UL1185|
Technical drawing
**==> picture [235 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
131mm<br>J kK<br>’);[ \) 57.5mm<br>is aa ™A<br>we, 36mm<br>U/ y<br>**----- End of picture text -----**<br>
## EU & UK Declaration of Conformity @)7Z2@S.G40%
**==> picture [421 x 449] intentionally omitted <==**
**----- Start of picture text -----**<br>
We, the responsible manufacturer;<br>Company Name: Mascot Electronics AS<br>Postal Address: P.O.Box 177, N-1601 Fredrikstad, NORWAY<br>Visiting Address: Mosseveien 109, N-1624 Gressvik, NORWAY<br>Telephone: (+47) 69 36 43 00 E-mail: sales@mascot.com WEB: www.mascot.com<br>declare that this Declaration is issued under our sole responsibility and belongs to the following product(s):<br>Product and Power Supply Unit<br>intended purpose:<br>Brand(s): 2) and/or TILASLGE {may also carry additional customer name, logo or trade mark)<br>Type(s)/ 3320 (may also carry additional customer model name)<br>Model(s)/UDI-DI: models: 3320-50, 3320-60, 3320-75, 3320-90, 3320-12, 3320-15, 3320-18,<br>3320-24 & 3320-36<br>Batch / Serial No./ all CE- and/or UKCA- marked products produced from the date indicated below<br>UDI-PI: (for production date: see marking on the product)<br>Description: Input: max. 1.35 A 100-120 V / 220-240 VAC 50-60 Hz, Class | or Il<br>Output: 3320-50: 5 VDC+3% max. 8 A/ 40 W<br>3320-60: 6 VDC +3% max. 6.66 A/ 40 W<br>3320-75: 7.5 VDC + 3% max. 7A /40W<br>3320-90: S$ VDC +3% max. 6 A/ 40 W<br>3320-12: 12 VDC 13% max. 5 A/40W<br>3320-15: 15 VDC + 3% max. 4A /40W<br>3320-18: 18 VDC + 3% max. 3.33 A/ 40W<br>3320-24: 24VDC+3% max. 2.5A/40W<br>3320-36: 36 VDC + 3% max. 1.66A/40W<br>The product(s) described above are in conformity with the relevant European Union harmonisation<br>legislation for CE-marking:<br>2014/35/EU *) EU Directive - Safety of electrical equipment ("Low-Voltage Directive") (LVD)<br>recast, repealing Directives 2006/95/EC & 73/23/EEC<br>2014/30/EU *) EU Directive - Electromagnetic Compatibility (EMC)<br>recast, repealing Directives 2004/108/EC & 89/336/EEC<br>(EU) 2017/745 EU Regulation - Medical Devices Regulation (MDR), Risk Class | Device<br>amending Directive 2001/83/EC, Regulations (EC) 178/2002 & (EC) 1223/2009 and<br>repealing Directives 90/385/EEC & 93/42/EEC<br>2009/125/EC *) EU Directive - Energy Related Products, Ecodesign (ERP)<br>recast, repealing Directive 2005/32/EC (EUP)<br>2015/863/EU EU Directive - Restriction on use of Hazardous Substances in EEE ("RoHS3")<br>recast, repealing Directives 2002/95/EC, 2008/35/EC & 2011/65/EU<br>**----- End of picture text -----**<br>
The product(s) described above are in conformity with the relevant U.K. legislation for UKCA-marking: Electrical Equipment (Safety) Regulations 2016
Electromagnetic Compatibility (EMC) Regulations 2016 The Medical Devices (Amendment etc.) (EU Exit) Regulations 2020, Risk Class | Device Ecodesign for Energy-Related Products (External Power Supplies) Regulations 2020 Draft Regulation, awaiting implementation
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
Page 1 of 3
## EU & UK Declaration of Conformity
**==> picture [329 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
The following harmonised standards and technical specifications have been applied:<br>**----- End of picture text -----**<br>
**==> picture [430 x 430] intentionally omitted <==**
**----- Start of picture text -----**<br>
(International editions and comments indicated in brackets):<br>Electrical Safety (to LVD-Directive):<br>EN 62368-1 *) EN 62368-1:2014 + /AC:2015 + /AC:2017 + /A11:2017 A/V, IT & Comm., Edition 2.0<br>(IEC 62368-1:2014 + /COR1:2015 + /COR2:2015, Edition 2.0) (also /EC 62368-1:2018 +/COR1:2020, Ed 3.0, not<br>yet an EN-norm)<br>Electrical Safety and Electromagnetic Compatibility (to MDR-Regulation):<br>EN 60601-1 EN 60601-1:2006 + /AC:2010 +/A1:2013 Medical electrical equipment, Edition 3.1<br>(IEC 60601-1:2005 + /A1:2012)<br>EN 60601-1-2 EN 60601-1-2:2015 Medical equipment, EMC - Requirements and tests, Edition 4.0<br>(IEC 60601-1-2:2014, Edition 4.0)<br>Electromagnetic Compatibility (to EMC-Directive):<br>EN 61000-6-1 a) EN 61000-6-1:2007 Immunity-residential, comm. & light-industrial environment, Edition 2.0<br>(IEC 61000-6-1:2005, Edition 2.0) (also IEC 61000-6-1:2016, Edition 3.0, not yet an EN-norm)<br>EN 61000-6-3 *) EN 61000-6-3:2007 + /A1:2011 & /AC:2012 Emission-residential, comm. & light-industrial environment, Edition<br>2.1<br>(IEC 61000-6-3:2007 + /A1:2010, Edition 2.1)<br>EN 55032 oF EN 55032:2015 + /A11:2020 Emission-Multimedia Equipment, Edition 2.1<br>(CISPR 32:2015 +/A1:2019, Edition 2.1)<br>EN 55025 3) EN 55035:2017 Immunity- Multimedia Equipment, Edition 1.0<br>(CISPR 35:2016, Edition 1.0}<br>Ecodesign to EU ERP-Directive:<br>Commission Regulation (EC) No 2019/1782 *) implementing Directive 2005/32/EC with regard to ecodesign requirements for no-<br>load condition electric power consumption and average active efficiency of external<br>power supplies (Repealing Commission Regulation (EC) No 2019/1782 from 2020-<br>04-01) (Note: not applicable to Battery Chargers, ref. Article 1.2 item c) }<br>Ecodesign for U.K.:<br>Draft Regulation only (awaiting implementation} *) Draft "Ecodesign for Energy-Related Products (External Power Supplies} Regulations<br>2020” (Note: not applicable to Battery Chargers)<br>Ecodesign for U.S.A.:<br>US Code of Federal Regulations (CFR) *) 10 CFR Part 430 - Energy Conservation Program for Consumer Products,<br>Also called "DoE compliance” 10 CFR Part 430, Subpart B - Test Procedures,<br>10 CFR Appendix Z to Subpart B of Part 430, Uniform Test Method for Measuring<br>the Energy Consumption of External Power Supplies.<br>California Code of Regulations (CCR) *) CCR Title 20- Public Utilities and Energy,<br>Also called "CEC-400 compliance” referring to CEC-400-2017- Division 2 - State Energy Resources Conservation and Development Commission,<br>002 "2016 Appliance Efficiency Regulations” issued by California Chapter4 - Energy Conservation, Article 4 - Appliance Efficiency Regulations,<br>Energy Commission Sections 1601 to 1609<br>Restriction of the Use of certain Hazardous Substances (RoHS) for EU:<br>2015/863/EU "RoHS3" EU Directive - Restriction on use of Hazardous Substances in EEE Restriction of the<br>Use of certain Hazardous Substances in Electrical and Electronic Equipment<br>Restriction of the Use of certain Hazardous Substances for UK:<br>The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations<br>2012<br>**----- End of picture text -----**<br>
Additional information: Compliance with harmonised standards and technical specifications may have been verified by the manufacturer, by third party testing or by a Certification Body (NCB). *) used above denotes verified by the manufacturer only. The products are considered Risk Class | devices according to EU Medical Device Regulation (MDR) and the U.K. Medical Devices (Amendment etc.) (EU Exit) Regulations 2020. The products provides two Means Of Patient Protection (2 MOPP) to standard IEC 60601-1.
Page 2 of 3
Mascot AS, PO Box 177 ● 1601 Fredrikstad NORWAY ● sales@mascot.no ● www.mascot.no
Date: Sun Mar 03 2024
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →