- Manufacturer: ETA
- Product type: Thermal Magnetic Circuit Breakers
- No. of Poles: 2 Pole
- Product Range: 3120
- Current Rating: 1A
- Voltage Rating VAC: 240V
- Circuit Breaker Mounting: Panel
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 37.2 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Thermal Circuit Breaker 3120-F... Description** The 3120 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 3120 is ideally suited for overload protection of motors, pumps, transformers and cables. The 3120 circuit breaker is also available as a switch-only version in accordance with the IEC/EN 61058 (see data sheet switch 3120-F-..Q1). **Product characteristics:** l rocker or push button actuation l single pole and double pole versions l reliable switching behaviour (positively trip-free) l convenient snap-in mounting l international approvals ~~_~~ **Options and add-on modules:** ~~.~~ l illumination l water splash protection **Technical data** l auxiliary contacts **Technical data** l auxiliary contacts l under voltage trip l remote trip **For details please see Technical information** l magnetic trip Rated voltage AC 240 V, DC 50 V l push-in terminals l appliance inlet module Current rating range 0.1...20 A (up to 30A upon request for single pole units) **Typical life 1-pole Typical applications** AC 240 V: 0.1...20 A 30,000 operations at 1 x IN, inductive Medical and laboratory equipment, apparatus and machine DC 50 V: 0.1...4 A 30,000 operations at 1 x IN, inductive construction, professional tools, household and garden appliances, 4.5...16 A 30,000 operations at 1 x IN, resistive offices machines, audio equipment, machine tools DC 28 V: 0.1...20 A 30,000 operations at 1 x IN, inductive **Typical life 2-pole Current ratings and internal resistance values** AC 240 V: 0.1...16 A 50,000 operations at 1 x IN, inductive 17...20 A 30,000 operations at 1 x IN, inductive **Current rating Internal Current rating Internal** DC 50 V: 0.1...16 A 50,000 operations at 1 x IN, inductive **(A) resistance (A) resistance** 17...20 A 50,000 operations at 1 x IN, inductive **per pole (Ω) per pole (Ω)** Ambient temperature -30 … 60 °C 0.1 94 4 0.0435 Insulation coordination 2.5 kV /2 reinforced insulation at (IEC 60664) operating area 0.2 24 4.5 0.0435 **Dielectric strength** 0.3 12 5 0.0325 Operating area test voltage AC 3,000 V 0.4 5.30 6 0.0215 pole to pole (2-pole) test voltage AC 1,500 V Insulation resistance > 100 MΩ (DC 500 V) 0.5 4.20 7 0.0165 0.6 2.90 8 0.0165 Interrupting capacity Icn 0.1...2 A 10 x IN 2.5...20 A 1-pole 150 A 0.8 1.50 10 < 0.02 2-pole 250 A 1 0.9 12 < 0.02 Interrupting capacity (UL 1077) 1.2 0.80 14 < 0.02 IN UN Inc 1-pole, 2- pole 0.1...20 A AC 250 V 5000 A, C, 1 1.5 0.45 15 < 0.02 1-pole, 2- pole 0.1...20 A DC 50 V 1000 A, C, 1 2 0.27 16 < 0.02 Degree of protection operating area IP40 2.5 0.0785 18 < 0.02 (IEC 60529) terminal area IP00 3 0.0595 20 < 0.02 with water splash cover IP54 or IP66 Vibration 8 g (57-500 Hz), ± 0.61 mm (10-57 Hz) ~~=S555~~ 3.5 0.0565 ~~===~~ test to IEC 60068-2-6, test Fc 10 frequency cycles/axis ~~==~~ **Current consumption of illumination** Shock 30 g (11 ms) test to IEC 60068-2-27, test Ea **Operating voltage Current consumption** Corrosion 96 hours at 5 % salt mist, **Y R G** test to IEC 60068-2-11, test Ka Humidity 240 hrs in 95 % RH DC 12 V 5.2 mA 2 mA 1.4 mA test to IEC 60068-2-78, DC 24 V 4.5 mA 2.2 mA 1.6 mA test Cab DC 48 V 4.5 mA 2 mA 1.6 mA Mass approx. 33 g (2-pole) approx. 27 g (1-pole) AC 115 V 2.8 mA 1.1 mA 1 mA approx. 42 g (2-pole with PT terminals) AC 230 V 2.2 mA 0.9 mA 0.9 mA **www.e-t-a.de** 1806 1 ## **Thermal Circuit Breaker 3120-F...** ## **Order numbering code** ## **Order numbering code** |**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**3120**||thermal rocker-actuated circuit breaker||||||||||||||||||||| |||**Mounting method**||||||||||||||||||||| |||**F**||flange mounting snap-in frame||||||||||||||||||| |||<br> <br> <br> <br> <br> <br> <br> <br> <br> <br> <br> <br> <br> <br>|<br> <br> <br> <br> <br> <br> <br> <br> <br> <br> <br> <br> <br> <br>|**Size of frame**||||||||||||||||||| |||||**3**||standard, to fit mounting cut-out 50.5 x 21.5 mm||||||||||||||||| |||||**5**||standard, to fit mounting cut-out 44.5 x 22 mm||||||||||||||||| |||||**7**||special style, to fit mounting cut-out 44.5 x 22 mm||||||||||||||||| |||||<br> <br> <br> <br> <br> <br> <br> <br> <br> <br>|<br> <br> <br> <br> <br> <br> <br> <br> <br> <br>|**Number of poles**||||||||||||||||| |||||||**1**||1-pole, thermally protected||||||||||||||| |||||||**2**||2-pole, thermally protected||||||||||||||| |||||||**5**||2-pole, 1-pole thermally protected||||||||||||||| |||||||<br> <br> <br> <br> <br> <br>|<br> <br> <br> <br> <br> <br>|**Mounting frame design (F3 & F5)**||||||||||||||| |||||||||**1**<br>collar height 1 mm||||||||||||||| |||||||||**3**<br>collar height 9 mm||||||||||||||| |||||||||**4**<br>collar height 2 mm with water<br>splash protection (IP54)||||||||||||||| |||||||||**Mounting frame design (F7)**||||||||||||||| |||||||||**R**||black||||||||||||| |||||||||**T**||black with snap-on water splash cover||||||||||||| |||||||||||**Terminal configuration**||||||||||||| |||||||||||**PT**push-in terminals||||||||||||| |||||||||||**P7**blade terminals||||||||||||| |||||||||||**H7**as P7, terminals 11 and 21 with flat head<br>screws M3.5 - standard for units with<br>undervoltage release module||||||||||||| |||||||||||**N7**as P7, with additional shunt terminals 12(i)<br>and 22(i)||||||||||||| |||||||||||**G7**as N7, terminals 11 and 21 with flat head<br>screws M3.5||||||||||||| |||||||||||||**Characteristic curve**||||||||||| |||||||||||||**T1**||thermal trip||||||||| |||||||||||||||**Actuator style**||||||||| |||||||||||||||**W**rocker for frame size F3 & F5||||||||| |||||||||||||||**A**||rocker for frame size F7||||||| |||||||||||||||<br> <br> <br> <br> <br> <br> <br> <br> <br>||**Colour and illumination**||||||| |||||||||||||||||**01.**|||rocker black opaque|||| |||||||||||||||||**02.**|||rocker white opaque|||| |||||||||||||||||**04.**|||rocker red opaque|||| |||||||||||||||||**14. R**|||rocker red translucent with<br>LED illumination|||| |||||||||||||||||**15. Y**|||rocker orange translucent with<br>LED illumination|||| |||||||||||||||||**19. G**|||rocker green translucent with<br>LED illumination|||| ||||||||||||||||||**A**<br>**D**<br>**F**<br>**Q**<br>**X** <br>**Q**<br> <br> <br> <br> <br>||**Marking for rocker style W**|||| |||||||||||||||||||||||0<br>I<br>I<br>0<br>ON<br>OFF<br>A<br>D<br>F X<br>Q: 0 and 1<br>moulded in| ||||||||||||||||||||**Marking for rocker style A**|||| ||||||||||||||||||||»I«and»O«moulded in|||| |||||||||||||||||||<br> <br> <br> <br>|**Illumination voltage range**<br>(=operating voltage)|||| ||||||||||||||||||||**1**|DC 12 V||| ||||||||||||||||||||**2**|DC 24 V||| ||||||||||||||||||||**3**|AC 115 V||| ||||||||||||||||||||**4**|AC 230 V||| ||||||||||||||||||||**5**|DC 48 V||| |||||||||||||||||||||||| |**3120-F**||||**7**||**2**||**R-**||**P7 T1-A**||||||**14 QR 4**||||||| |||||||||||||||||||<br>|<br>|**Current ratings**<br>**0.1...20 A**||| |||||||||||||||||||||||| |**3120-F**||||**7**||**2**||**R-**||**P7 T1-A**||||||**14 QR 4**||||**- 10 A**<br>ordering example||| |**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**|**Type No.**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**3120**||thermal circuit breaker with push button actuation||||||||||||||||||| |||**Mounting**||||||||||||||||||| |||**F**||flange mounting snap-in frame||||||||||||||||| |||<br> <br> <br> <br> <br> <br> <br> <br> <br>|<br> <br> <br> <br> <br> <br>|**Size**||||||||||||||||| |||||**2**||special frame for fitting splash cover||||||||||||||| |||||**3**||mounting cut-out 50.5 x 21.5 mm (panel thickness<br>1-6.35 mm)||||||||||||||| |||||<br> <br> <br> <br> <br> <br>|<br> <br> <br> <br> <br> <br>|**Number of poles**||||||||||||||| |||||||**1**||1-pole, thermally protected||||||||||||| |||||||**2**||2-pole, thermally protected||||||||||||| |||||||**5**||2-pole, 1-pole thermally protected||||||||||||| |||||||<br> <br>||**Style**||||||||||||| |||||||||**F**||frame with 2 push buttons||||||||||| |||||||||**G**||frame with one push button (reset only)||||||||||| |||||||||||**Terminal configuration**||||||||||| |||||||||||**PT**push-in terminals||||||||||| |||||||||||**P7**blade terminals||||||||||| |||||||||||**H7**as P7, terminals 11 and 21 with flat head<br>screws M3.5 - standard for units with<br>undervoltage release module||||||||||| |||||||||||**N7**as P7, with additional shunt terminals 12(i)<br>and 22(i)||||||||||| |||||||||||**G7**as N7, terminals 11 and 21 with flat head<br>screws M3.5||||||||||| |||||||||||||**Characteristic curve**||||||||| |||||||||||||**T1**||thermal trip||||||| |||||||||||||||**Actuators / colour / illumination**||||||| |||||||||||||||**D01X**1 push button*black opaque||||||| |||||||||||||||**D02X**1 push button*white opaque||||||| |||||||||||||||**D04X**1 push button*red opaque||||||| |||||||||||||||**D19XG**1 push button* green translucent<br>with LED illumination||||||| |||||||||||||||**SGRX**2 push buttons green/red opaque<br>without illumination||||||| |||||||||||||||**SGRXG**2 push buttons green/red translucent<br>with LED illumination||||||| ||||||||||||||||||**Illumination voltage range**<br>(=operating voltage)|||| ||||||||||||||||||**1**||DC 12 V|| ||||||||||||||||||**2**||DC 24 V|| ||||||||||||||||||**3**||AC 115 V|| ||||||||||||||||||**4**||AC 230 V|| ||||||||||||||||||**5**||DC 48 V|| ||||||||||||||||||<br>||**Current ratings**|| ||||||||||||||||||||**0.1...20 A**|| |||||||||||||||||||||| **3120- F 3 2 F - P7 T1- S GRXG 4-10 A** ordering example *reset only **Packaging unit: 20, 25, 35, 50 or 60 pcs, depending on the version** **www.e-t-a.de** 2 1806 **Thermal Circuit Breaker 3120-F...** ## **Preferred types** |**preferred type F7**<br>**2-pole protected**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**|**preferred ratings (A)**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||**0.5 **|**1 **|**1.5 **|**2**|**3**|**4**|**5**|**6**|**8 **|**10 **|**12 **|**15 **|**16 **|**20**| |3120-F72R-P7T1-<br>A14QR4-|x|x|x|x|x|x|x|x|x|x|x|x|x|x| |**preferred type F3**<br>**1-poleprotected**|**0.5 **|**1**|**2**|**3**|**4**|**5**|**6**|**8 **|**10 **|**12 **|**15 **|**16 **|**20**|| |3120-F311-P7T1-<br>W02D-||x|||x|x|x|x|x||x||x|| |**preferred type F3**<br>**2-poleprotected**|**0.5 **|**1**|**2**|**3**|**4**|**5**|**6**|**8 **|**10 **|**12 **|**15 **|**16 **|**20**|| |3120-F321-P7T1-<br>W01D-|x|x|x|x|x|x|x|x|x|x|x|x|x|| |**preferred type F5**<br>**2-poleprotected**|**0.5 **|**1**|**2**|**3**|**4**|**5**|**6**|**8 **|**10 **|**12 **|**15 **|**16 **|**20**|| |3120-F521-P7T1-<br>W01D-||x|x|x|x|x|x|x|x|x|x|x|x|| ## **Approvals** |**Approval**<br>**authority**|**Standard**|**Rated**<br>**voltage**|**Current rating range**| |---|---|---|---| |VDE|IEC/EN 60934|AC 240 V<br>DC 50 V<br>DC 50 V<br>DC 28 V|0.1 A…20 A<br>0.1...20A (2-pole)<br>0.1...4 A (1-pole)<br>01 A20 A| |UL|UL 1077|<br>AC 250 V<br>DC 50 V<br>AC 250 V|. …<br>0,1 A…20 A<br>0,1 A…20 A<br>30 A (2 poles in par-<br>allel)| |CSA|C22.2 No 235|AC 250 V<br>DC 50 V<br>AC 250 V|0,1 A…20 A<br>0,1 A…20 A<br>30 A(2poles inparallel)| |CQC|GB 17701|AC 240 V<br>DC 50 V|0.1 A…20 A<br>0.1 A…20 A| ## **Schematic diagrams** **==> picture [249 x 191] intentionally omitted <==** **----- Start of picture text -----**<br> 2-pole, 2-pole,<br>thermally protected on both poles thermally protected on one pole only<br>11 line 21 11 line 21<br>12(i) 22(i) 12(i) 22(i)<br>12(k) load 22(k) 12(k) load<br>1-pole,<br>thermally protected<br>line<br>11<br>12(i) 22(i)<br>12(k) load<br>**----- End of picture text -----**<br> ## **Time/current characteristics** **==> picture [229 x 467] intentionally omitted <==** **----- Start of picture text -----**<br> single or double pole load<br>0.1…2 A<br>10000 +60 °C<br>+140 °F<br>+23 °C<br>+73.4 °F<br>-30 °C<br>1000 -22 °F<br>100<br>10<br>1<br>0.1<br>1 2 4 6 8 10 20 40<br>… times rated current<br>2.5…20 A<br>10000 +60 °C<br>+140 °F<br>+23 °C<br>+73.4 °F<br>-30 °C<br>1000 -22 °F<br>100<br>10<br>1<br>0.1<br>1 2 4 6 8 10 20 40<br>… times rated current<br>Trip time in seconds<br>Trip time in seconds<br>**----- End of picture text -----**<br> ||The time/current characteristic depends on the ambient temperature.|The time/current characteristic depends on the ambient temperature.|The time/current characteristic depends on the ambient temperature.|The time/current characteristic depends on the ambient temperature.|| |---|---|---|---|---|---| ||In order to eliminate nuisance tripping, please|multiply the|current||| ||rating by a derating factor (see chapter Technical|Information)|||| ||ambient<br>temperature [°C]<br>-30<br>-20<br>-10<br>0|23<br>40||50|60| ||Temperature factor<br>0.8<br>0.84<br>0.88<br>0.92|1<br>1.08||1.14|1.23| **www.e-t-a.de** 1806 3 **Thermal Circuit Breaker 3120-F...** ## **Dimensions** **==> picture [461 x 475] intentionally omitted <==** **----- Start of picture text -----**<br> 3120-F2.F-… 3120-F2.F-PT... 12.65 12.65 5.5<br>water splash cover<br>retaining clip (see accessories)<br>panel<br>cover<br>35.4 74<br>hole for screw<br>16.2 60 [±0.1] 16.1 ø 4 mm e.g.: EJOT PT<br>screw K40 14.1<br>ø3.2<br>ø 3.2<br>PT-screw<br>type K40 12(i) 12(k) 11 12(i) 12(k) 11<br>ø4 mm<br>10.7<br>3.5 3<br>21 15.5 21 42.5<br>41<br>blade terminal EN 60934 – 6.3 x 0.8<br>flat head screw M3.5x6<br>tightening torque max. 0.8 Nm<br>3120-F3.1 3120-F3.1-PT 12.65 12.65 5.5<br>25<br>OFF position<br>25<br>16<br>54 16 54<br>12(i) 12(k) 11 12(i) 12(k) 11<br>10.7 3.5 3<br>21 15.5 21 42.5<br>41<br>blade terminal<br>EN 60934 – 6.3 x 0.8<br>flat head screw M3.5x6<br>tightening torque max. 0.8 Nm<br>10.7<br>15 14 9<br>10<br>10.2 10.2<br>4.5 3.5<br>33<br>49<br>10<br>10.7<br>7<br>9<br>35 33 48<br>10<br>**----- End of picture text -----**<br> **3120-F 3.3** collar height 9 mm **3120-F 3.4** with water splash protection (IP54) **==> picture [187 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> 25 54<br>19.5 35<br>12(i) 12(k) 11<br>10.7 3.5 3<br>21 15.5<br>41<br>blade terminal EN 60934 – 6.3 x 0.8<br>flat head screw M3.5x6<br>tightening torque max. 0.8 Nm<br>9<br>35 33<br>10<br>**----- End of picture text -----**<br> **==> picture [191 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> 27 56<br>19.5 35<br>12(i) 12(k) 11<br>10.7 3.5 3<br>21 15.5<br>41<br>blade terminal EN 60934 – 6.3 x 0.8<br>flat head screw M3.5x6<br>tightening torque max. 0.8 Nm<br>10<br>3.8<br>33<br>10<br>**----- End of picture text -----**<br> **www.e-t-a.de** 4 1806 **Thermal Circuit Breaker 3120-F...** ## **Dimensions** ## **3120-F3.F-…-S…** ## **3120-F3.G-...-D...** **==> picture [455 x 183] intentionally omitted <==** **----- Start of picture text -----**<br> optional illumination in ON position optional illumination in ON position<br>OFF position OFF position<br>25 54 25 54<br>16.2 14.2 16.2 14.2<br>12(i) 12(k) 11 12(i) 12(k) 11<br>10.7 3.5 3 10.7 3.5 3<br>21 15.5 21 15.5<br>blade terminal EN 60934 – 6.3 x 0.8 41 blade terminal EN 60934 – 6.3 x 0.8 41<br>flat head screw M3.5x6 flat head screw M3.5x6<br>tightening torque max. 0.8 Nm tightening torque max. 0.8 Nm<br>15 10 15 10<br>33 33<br>10 10<br>**----- End of picture text -----**<br> **==> picture [206 x 395] intentionally omitted <==** **----- Start of picture text -----**<br> 3120-F 5.1<br>25<br>optional illumination<br>16 48<br>12(i) 12(k) 11<br>10.7 3.5 3<br>21 15.5<br>blade terminal EN 60934 – 6.3 x 0.8 41<br>flat head screw M3.5x6<br>tightening torque max. 0.8 Nm<br>3120-F5.3<br>25 48<br>19.5 35<br>12(i) 12(k) 11<br>3.5 3<br>10.7<br>21 15.5<br>41<br>blade terminal EN 60934 – 6.3 x 0.8<br>flat head screw M3.5x6<br>tightening torque max. 0.8 Nm<br>7<br>35 33<br>10<br>2 11<br>33<br>**----- End of picture text -----**<br> **==> picture [163 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> 12.65 12.65 5.5<br>25<br>16 48<br>12(i) 12(k) 11<br>21 42.5<br>10.7<br>9<br>48<br>**----- End of picture text -----**<br> **==> picture [51 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 3120-F5.1-PT<br>**----- End of picture text -----**<br> ## **3120-F5.4** **==> picture [180 x 148] intentionally omitted <==** **----- Start of picture text -----**<br> 25 48<br>19.5<br>35<br>12(i) 12(k) 11<br>3.5 3<br>10.7<br>15.5<br>21<br>41<br>blade terminal EN 60934 – 6.3 x 0.8<br>flat head screw M3.5x6<br>tightening torque max. 0.8 Nm<br>2<br>11<br>33<br>**----- End of picture text -----**<br> **www.e-t-a.de** 1806 5 **Thermal Circuit Breaker 3120-F...** ## **Dimensions** **==> picture [225 x 663] intentionally omitted <==** **----- Start of picture text -----**<br> Style F7.R<br>25 48 [±0.2]<br>.984 1.89 [±.008]<br>15.5 44.2-0.2<br>.610 1.74-.008<br>LINE<br>12(i) 12(k) 11<br>10.7 3.5 3<br>.421 .138 .118<br>21 15.5<br>.827 .610<br>41<br>blade terminals EN60934 - 6,3 x 0,8 1.61<br>flat head screw M3.5x6<br>tightening torque max. 0.8 Nm<br>3120-F7.R-PT<br>12.65 12.65 5.5<br>25<br>.984 0.49 0.49 0.22<br>15.5<br>48<br>.610 1.89<br>12(i) 12(k) 11<br>21 42.5<br>.827 1.67<br>Style F7.T<br>34 60<br>1.34 2.36<br>18.6 44.8<br>.732 1.76<br>LINE<br>12(i) 12(k) 11<br>10.7 3.5 3<br>.421 .138 .118<br>21 15.5<br>.827 .610<br>41<br>blade terminals 1.61<br>EN60934 - 6,3 x 0,8<br>flat head screw M3.5x6<br>tightening torque max. 0.8 Nm<br>8.9 .350 3<br>.118<br>33 1.30<br>10 .394<br>10.7 0.42<br>9.4 0.37<br>48 1,89<br>11.5 .453<br>33 1.30<br>10 .394<br>**----- End of picture text -----**<br> ## **Cut-out dimensions** **==> picture [249 x 290] intentionally omitted <==** **----- Start of picture text -----**<br> 3120-F2… t: metal min. 2 mm (.079 in.)<br> plastic min. 3 mm (.118 in.)<br>60±0.15<br>2.36 [+.006]<br>50.5 [+0.5] R2<br>1.99 [+.020] .079<br>Edges of working parts: ISO 13715<br>Cut-out for mounting style -F3 Cut-out for mounting<br>with rocker and push button style -F5/-F7<br>- 0.4-.016 with rocker - 0.4-.016<br>- 0.2 - 0.2 min. 2<br>-.008 min. 2.5 -.008 min .079<br>min .098<br>max. R1.5<br>max. R2 max .059<br>max .079<br>±0.05<br>±0.05 ±.002<br>±.002 44.5 [+0.2]<br>50.5 [+0.3] max. R0.3 1.75 [+.008]<br>1.99 [+.012] max .012<br>max. R0.3<br>max .012<br>Edges of working parts: ISO 13715<br>t<br>+0.2 +.008<br>+0.2 +.008 ø4.3 .169<br>26 1.02<br>1-6.35 .039-.250<br> 1-4 mm .039-.157 in.<br>+0.3 +.012<br>+0.2 +.008 22 .866<br>21.5 .846<br>**----- End of picture text -----**<br> ## **Cable cross sections PT terminals** |**cable**|**cross section with direct**<br>**hi ii**| |---|---| |rigid|**pus-n wrng**<br>1…4 mm2<br>(stripping length: 10 mm)| |flexible with wire end ferrule<br>(with or without plastic sleeve)|0.5…2.5 mm2| |**cable**|**cross section when opening**<br>**the push-in terminals**| |rigid|0.5…4 mm2<br>(stripping length: 10 mm)| |flexible without wire end ferrule|0.5…2.5 mm2| **www.e-t-a.de** 6 1806 **Thermal Circuit Breaker 3120-F...** ## **Installation drawing** **==> picture [101 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 3120 with blade terminals<br>**----- End of picture text -----**<br> **==> picture [225 x 149] intentionally omitted <==** **----- Start of picture text -----**<br> When installing the circuit breaker apply pressure on bezel only.<br>operating area<br>7 7 8 7 10<br>mounting area<br>10 15.5<br>**----- End of picture text -----**<br> ## **Terminal types** **==> picture [187 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 3120-F521-G7 3120-F551-G7<br>**----- End of picture text -----**<br> **==> picture [95 x 105] intentionally omitted <==** **==> picture [95 x 105] intentionally omitted <==** **==> picture [187 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 3120-F521-N7 3120-F551-N7<br>**----- End of picture text -----**<br> ## **3120 with push-in terminals** When installing the circuit breaker apply pressure on bezel only. **==> picture [217 x 131] intentionally omitted <==** **----- Start of picture text -----**<br> operating area<br>7 7 8 7 10<br>mounting area<br>25 30.5<br>**----- End of picture text -----**<br> **==> picture [95 x 105] intentionally omitted <==** **==> picture [91 x 100] intentionally omitted <==** **==> picture [187 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 3120-F521-H7 3120-F551-H7<br>**----- End of picture text -----**<br> **==> picture [212 x 105] intentionally omitted <==** **==> picture [186 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 3120-F521-P7 3120-F551-P7<br>**----- End of picture text -----**<br> **==> picture [95 x 100] intentionally omitted <==** **==> picture [92 x 101] intentionally omitted <==** **www.e-t-a.de** 1806 7 **Thermal Circuit Breaker 3120-F...** ## **Accessories** **==> picture [434 x 356] intentionally omitted <==** **----- Start of picture text -----**<br> Insulated cover Rear terminal shroud black (IP64)<br>Y 303 068 01 Y 304 275 01<br>2.5 40.5<br>.098 1.59 1.75+0.5-0.25 20.5<br>.069 [+.020] -.010 .807<br>20<br>.787<br>Terminal adapter<br>Y 303 862 01<br>4<br>ø8<br>.157<br>.315<br>Water splash cover, transparent (IP66)<br>for mounting style -F2..<br>X 221 619 01 48<br>1.89<br>blade terminal DIN 46244-C-Ms-S<br>(QC 2x.110)<br>Blanking piece in -F3 frame ø8<br>Y 303 885 31 .315<br>54 matt finish 25<br>2.13 .984<br>31 16.5 ø4.4<br>1.22 .650 .173<br>60<br>2.36<br>73<br>41 21 2.87<br>R3.5<br>.138<br>9<br>.354<br>0.9 .035 50 1.97<br>+5 +.197<br>70 2.76<br>10 .394<br>3.7 .146<br>13.5 .531 4<br>.157<br>25 .984<br>16.5 .650<br>1<br>.039<br>3.4 .134<br>35 1.38<br>33 1.30 36 1.42<br>**----- End of picture text -----**<br> **==> picture [228 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> Blanking piece in -F3 frame<br>Y 303 885 31<br>54 matt finish 25<br>2.13 .984<br>31 16.5<br>1.22 .650<br>41 21<br>1.61 .827<br>1<br>.039<br>33 1.30 36 1.42<br>**----- End of picture text -----**<br> **==> picture [174 x 254] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting of<br>X221 619 01<br>**----- End of picture text -----**<br> All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. **www.e-t-a.de** 8 1806 **Thermal Circuit Breaker 3120-F...** ## **Accessories** ## **Plug-in connector Y 31214001** Connecting cables can be pre-wired. Two retaining clips ensure a tight fit. **==> picture [360 x 193] intentionally omitted <==** **----- Start of picture text -----**<br> 5,5 12<br>42 21,2<br>4,5<br>24<br>**----- End of picture text -----**<br> ## Benefits: - Reduced installation time and costs for final assembly - Quick replacement of devices ## Note: ## Delivery without receptacles. Dimensions of receptacles (width 6.3 mm) are in accordance with DIN 46340 part 3, shape A. Examples of suitable receptacles: Stocko RSB 7916 F6,3-1 / Klaucke type 2730 / Vogt type 3832d.67 / TE FASTON Terminals 250 Series / Delphi Packard 58 Series ## Plug-in connector mounted on circuit breaker: **==> picture [239 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> 42 21,2<br>33<br>24<br>**----- End of picture text -----**<br> **==> picture [123 x 179] intentionally omitted <==** **www.e-t-a.de** 1806 9 **Thermal Circuit Breaker 3120-F...** ## **Description - Appliance inlet module X3120-A/-B** The appliance inlet module X3120 with circuit breaker type 3120-F5/ -F7/-F8 combines up to four functions within a single component: A C14/C20 appliance inlet, a rocker-actuated or push button switch and resettable overcurrent protection and a filter. Screw-type mount- ing from the front or from the rear. **Typical applications** Electrical medical apparatus, laboratory equipment, professional audio equipment and office machines. **1 X3120-A X3120-B Approvals** ~~>~~ **X3120-A – C14 inlet Authority Standard Voltage ratings Max. current Order numbering code** ENEC IEC/EN AC 240 V 10 A 60320-1 **Type No.** UL/CSA UL 498 AC 250 V 15 A **X3120** Appliance inlet module for circuit breaker type 3120 **Module** CQC CCC AC 250 V 10 A **A** appliance inlet C14 (with filter) **B** appliance inlet C20 (without filter) **Approvals X3120-A – filter 04 Mounting** screw-type mounting Design coresponding to UL 1283, CSA 22.2 No. 8 1986, **Filter** IEC/EN 60939 **00** without filter **01** general performance IEC inlet filter **X3120-B – C20 inlet 03** general performance IEC inlet filter, medical version **Authority Standard Voltage ratings Max. current 06** high performance IEC inlet filter, medical version **Filter current rating** ENEC IEC/EN AC 240 V 16 A **00** without filter 60320-1 **01** 1 A UL/CSA UL 498 AC 240 V 20 A **03** 3 A **06** 6 A **08** 8 A **10** 10 A **Selection current rating of the filter 12** 12 A **15** 15 A **Version Current rating Minimum current rating of the filter circuit breaker 01** not wired; mounting position 3120: OFF position to connector 0,1...1 A 1 A **11** wired; mounting position 3120: 1,2...3 A 3 A OFF position to connector **Assembly status** 3,5...6 A 6 A **M** module supplied with circuit breaker 7...8A 8 A 3120 and filter (module A) fitted ~~——~~ 9...10 A 10 A **X3120- B 04 00 00 01 M** ordering example 12 A 12 A 14...15 A 15 A ~~2Sll=~~ Circuit breaker type 3120 with thermal release protects the filter in case of overloads. For the protection of the filter in the event of higher overcurrents we recommend circuit breaker type 3120 with thermal-magnetic release (3120...M1...). Further technical information upon request. All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. **www.e-t-a.de** 10 1806 ## **Thermal Circuit Breaker 3120-F...** ## **Technical Data (type X3120-B, without filter)** ## **Technical Data (type X3120-A with filter)** |Rated voltage|AC 240 V| |---|---| |Current rating|16 A (IEC)| |(inlet)|20 A(UL/CSA)| |Ambient temperature|-25°C ...+60°C| |Number of poles|L, N + earth| |Protection class:|I| |Mounting method:|screw-type mounting| ||(front or rear)| |Connection:|blade terminals DIN 46244<br>6.3 mm x 0.8 mm| |Housing material:|thermoplastics, black UL94V-0| |Appliance inlet:|C20 according to IEC/EN 60320-1,| ||UL498| |Mains switch:|<br>Circuit breaker 3120-F5/-F7/-F8| ||(3120-F8 with push button actuation:| ||technical data upon request)| |Rated voltage|AC 250 V| |---|---| |Current rating (inlet)|10 A (IEC)| ||15 A(UL/CSA)| |Current rating (filter)|1 A,3 A,6 A,8 A,10 A,12 A,15 A| |Ambient temperature|-25°C ...+60°C| |Number of poles|L, N + earth| |Protection class:|I| |Mounting method:|screw-type mounting| |Connection:|(front or rear)<br>blade terminals DIN 46244| ||6.3 mm x 0.8 mm| |Housing material:|thermoplastics, black UL94V-0| |Appliance inlet:|C14 according to IEC/EN 60320-1,| ||UL498| |Mains switch:|<br>Circuit breaker 3120-F5/-F7/-F8| ||(3120-F8 with push button actuation:| ||technical data upon request)| ## **Dimensions (type X3120-B)** **==> picture [249 x 232] intentionally omitted <==** **----- Start of picture text -----**<br> 5.5<br>0.21<br>circuit breaker 3120<br>26<br>Ø 3.3<br>37 Ø .130 47 1.0<br>1.457 1.85<br>90 3.54 100 3.9<br>**----- End of picture text -----**<br> ## **Dimensions (type X3120-A)** **==> picture [249 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> 40 11.8<br>1.57 .465<br>Ø 3.3<br>36.2 Ø .130 49.3<br>1.43 1.94<br>80 3.15 91.5 3.60<br>**----- End of picture text -----**<br> ## **Cut-out dimensions (type X3120-B)** **==> picture [249 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> 79.5 ±0.3<br>90 ±0.1<br>M3/ Ø3.3<br>32.5 ±0.3<br>**----- End of picture text -----**<br> ## **Cut-out dimensions (type X3120-A)** **==> picture [249 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> R3.0 [+.0] -1.0 (4x) 72.0 -.0 [+.3]<br>.12 [+.00] -.03 (4x) 2.83 [+.01] -.00<br>80.0 ± .1<br>3.15±.00<br>+.3 -.0 +.01 -.00<br>Ø 3.6 (2x) Ø .14 (2x)<br>29.0 1.14<br>**----- End of picture text -----**<br> **www.e-t-a.de** 1806 11 ## **Thermal Circuit Breaker 3120-F...** ## **Electrical schematics X3120-A** **==> picture [176 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> X3120-A0401<br>General performance filter<br>Cx 2xL 2xCy N' 11<br>N 12 (K)<br>PE PE 3120<br>P 3 ! O rho 22 (K)<br>Line P' 21<br>Load<br>X3120-A0403 und X3120-A0406<br>Medical version<br>Cx R 2xL N' 11<br>N 12 (K)<br>PE PE 3120<br>P 22 (K)<br>Line P' 21<br>Load<br>**----- End of picture text -----**<br> ## **X3120-A0401 and X3120-A0403 - General performance filter** **==> picture [406 x 34] intentionally omitted <==** **----- Start of picture text -----**<br> Typical filter attenuation: Per CISPR 17<br>A = 50 Ω / 50 Ω sym; B = 50 Ω / 50 Ω asym; C = 0.1 Ω / 100 Ω sym; D = 100 Ω / 0.1 Ω sym<br>1 and 3 A types 6 to 10 A types 12 and 15 A types<br>**----- End of picture text -----**<br> ## **X3120-A0406 - High performance filter** - Typical filter attenuation: Per CISPR 17 A = 50 Ω / 50 Ω sym; B = 50 Ω / 50 Ω asym; C = 0.1 Ω / 100 Ω sym; D = 100 Ω / 0.1 Ω sym 1 and 3 A types 6 to 10 A types 12 and 15 A types **www.e-t-a.de** 12 1806 **Thermal Circuit Breaker 3120-F...** ## **Filter selection table** |**Filter**|**Rated current**<br>**50°C (25°C)**<br>**A**|**Leakage current**<br>**250VAC/50 Hz**<br>**µA**|**Inductance L**<br>**mH**|**Capacitance Cx**<br>**µF**|**Capacitance Cy**<br>**nF**|**Resistance R**<br>**kΩ**| |---|---|---|---|---|---|---| |X3120-A040101..M|1 (1.2)|373|12|0.1|2.2|| |X3120-A040103..M|3 (3.5)|373|2.5|0.1|2.2|| |X3120-A040106..M|6 (7.2)|373|0.78|0.1|2.2|| |X3120-A040108..M|8 (10.6)|373|0.5|0.1|2.2|| |X3120-A040110..M|10 (11.6)|373|0.225|0.1|2.2|| |X3120-A040112..M|12 (12)|373|0.11|0.1|2.2|| |X3120-A040115..M|15 (15)|373|0.075|0.1|2.2|| |||||||| |X3120-A040301..M|1 (1.2)|2|12|0.1||1000| |X3120-A040303..M|3 (3.5)|2|2.5|0.1||1000| |X3120-A040306..M|6 (7.2)|2|0.78|0.1||1000| |X3120-A040308..M|8 (10.6)|2|0.5|0.1||1000| |X3120-A040310..M|10 (11.6)|2|0.225|0.1||1000| |X3120-A040312..M|12 (12)|2|0.11|0.1||1000| |X3120-A040315..M|15 (15)|2|0.075|0.1||1000| |||||||| |X3120-A040601..M|1 (1.2)|2|59.53|0.1||1000| |X3120-A040603..M|3 (3.5)|2|13.45|0.1||1000| |X3120-A040606..M|6 (7.2)|2|4.1|0.1||1000| |X3120-A040608..M|8 (10.6)|2|2.3|0.1||1000| |X3120-A040610..M|10 (11.6)|2|1.02|0.1||1000| |X3120-A040612..M|12 (12)|2|0.58|0.1||1000| |X3120-A040615..M|15 (15)|2|0.4|0.1||1000| **www.e-t-a.de** 1806 13 ## **Thermal Circuit Breaker 3120-F...** ## **Description undervoltage release module X3120-U** Add-on module for circuit breaker type 3120. The undervoltage release module trips the 3120 circuit breaker/switch combination in the event of a voltage drop or power failure. When the voltage is restored, the 3120 must be reset to reconnect the load, thereby avoiding the safety hazards associated with automatic re-start of machinery. **Note:** Basic unit 3120-...-H7 or -G7 requires screw terminals. Not possible in combination with PT terminals. ## **Typical applications** All machines and devices where automatic re-start after restoration of power could be dangerous, e.g. drilling machines, electric saws, sausage slicers etc. ## **Order numbering code** **Type No. X3120** module for type 3120 **Module U** undervoltage release module **Design 00** standard (without separate connections) **01** 1 blade terminals 2.8x0.8 **02** 2 blade terminals 2.8x0.8 **Rated voltage 00** AC 230/240 V 50/60 Hz **01** AC 120 V 50/60 Hz **Assembly status M** module mounted to circuit breaker 3120 **X3120- U 00 00 M** ordering example ## **Dimensions** **==> picture [249 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> flat head screw M3.5x6for mains connection 41 +0.1- 0.2<br>tightening torque max. 0.8 Nm 1.61 [+.004] - .008<br>6.6<br>.260 21 blade terminal<br>.827 21 DIN 46244-A2.8-0.8<br>22 .827 (QC .110)<br>1 terminal<br>.866 X3120-U01…<br>23.5<br>.925 Without separate terminal(s): X3120-U00…<br>33.5 1.32 15°<br>7.6 .299<br>**----- End of picture text -----**<br> ## **Schematic diagrams** **==> picture [249 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> X3120-U00… X3120-U01… X3120-U02…<br>line line line line line<br>11 21 11 A2 21 11 A1 A2 21<br>12(i) 22(i) 12(i) 22(i) 12(i) 22(i)<br>12(k) 22(k) 12(k) 22(k) 12(k) 22(k)<br>load load load<br>U< U< U<<br>**----- End of picture text -----**<br> ## **Technical data** |Voltage ratings|AC 100 V; 120 V; 230/240 V (50/60 Hz);| |---|---| ||DC 24 V| |Voltage tolerances|+ 10 % / - 15 %| |Typical life|20,000 cycles| |Current consumption|approx. 2.5 mA| |Release values|0.2 x UN< U < 0.7 x UN| ||(at a rated voltage of AC 100 V| ||the device can trip at 70 V and| ||must trip at 20 V)| |Release delay|< 20 ms| |Latch-in values|≥ 85 % UN| |Ambient temperature|-30 … 60 °C| |Vibration|8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)| ||test to IEC 60068-2-6, test Fc| ||10 frequency cycles/axis| |Shock|30 g (11 ms)| ||test to IEC 60068-2-27, test Ea| |Corrosion|48 hours at 5 % salt mist,| ||test to IEC 60068-2-11, test Ka| |Humidity|240 hrs in 95 % RH| ||test to IEC 60068-2-78,| ||test Cab| |Mass|approx. 53 g (including base unit)| All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. **www.e-t-a.de** 14 1806 ## **Thermal Circuit Breaker 3120-F...** ## **Description auxiliary contact module X3120-S** Add-on module for circuit breaker type 3120-F. The auxiliary contact module has a change-over contact as signal contact and is operated with actuation of the CBE. Not possible in combination with PT terminals. ## **Typical applications** Status monitoring of CBE and/or the connected loads. ## **Order numbering code** ## **Type No.** - **X3120** module for types 3120 and 3140 |||**Module**|**Module**|**Module**|**Module**|**Module**|**Module**|**Module**|**Module**|**Module**|**Module**||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||**S**||auxiliary contact module|||||||||| |||||**Contact configuration**|||||||||| |||||**0**||change-over contact|||||||| |||||||**Terminal design**|||||||| |||||||**1**||blade terminals 2.8 x 0.5 (||||QC .110), silver-plated|| |||||||||**Contact rating**|||||| |||||||||AC voltage||||DC voltage|| |||||||||rated voltage|||rated<br>current|rated<br>voltage|rated<br>current| |||||||||**A**10 V - 250 V|||0.1...4 A|12 V|0.1...4 A| |||||||||||||24 V|0.1...4 A| |||||||||||||60 V|0.1...1 A| |||||||||||||110 V|0.1...0.5 A| |||||||||||||220 V|0.1...0.25 A| |||||||||**B**5 V - 250 V|||5 ...100<br>mA|5 V - 250 V|5...100 mA| |||||||||<br>|**Assembly status**<br>**M**module mounted to circuit breaker 3120||||| ||||||||||||||| |**X3120- S**||||**0**||**1**||**A M**<br>ordering example|||||| * without approval mark ## **Dimensions** **==> picture [249 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> 21 10<br>.827 .394 14<br>.551<br>blade terminals DIN 46244-A2.8-0.5-Ms (QC .110)<br>plated<br>7.5 7.5<br>.295 .295 2<br>19.8 .079<br>.780<br>25.5 1.00<br>8.5 .335<br>**----- End of picture text -----**<br> ## **Schematic diagram** ||11|line<br>21<br>34<br>32<br>22(i)<br>31<br>22(k)<br>load<br>module mounted| |---|---|---| ||12(i)<br>12(k)|| |||| |**Technical data**||| |||| |Rated voltage||AC 250 V, DC 220 V| |Current ratings||0.1...4 A / 5...100 mA| |Typical life||50,000 cycles| |Ambient temperature||-30…60 °C| |**Dielectric strength**<br>between main and<br>auxiliary circuit||test voltage AC 3,000 V| |Insulation resistance||> 100 MOhm (DC 500 V)| |Vibration||6 g<br>(57-500 Hz), ± 0.46 mm (10-57 Hz)<br>test to IEC 60068-2-6, test Fc<br>10 frequency cycles/axis| |Shock||15 g (11 ms)<br>test to IEC 60068-2-27, test Ea| |Corrosion||96 hours at 5 % salt mist,<br>test to IEC 60068-2-11, test Ka| |Humidity||240 hrs in 95 % RH<br>test to IEC 60068-2-78,<br>test Cab| |Mass||approx. 38 g (including base unit)| All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. **www.e-t-a.de** 1806 15 ## **Thermal Circuit Breaker 3120-F...** ## **Description remote trip module X3120-M** A module which adds remote trip capability to all versions of type 3120-F. A voltage applied across the coil, by means of an external sensor for example, will cause disconnection of the main switch/ circuit breaker mechanism. Not possible in combination with PT terminals. ## **Typical applications** Electrical remote trip of safety systems. ## **Order numbering code** **Type No.** **X3120** module for type 3120 **Module M** magnetic relay trip module **Style 2** magnetic remote trip coil **Terminal design P7** blade terminals DIN 46244-A6.3-0.8 **Assembly status M** module mounted to circuit breaker 3120 **Rated voltage AC 120, 230 V DC 12, 24 V** **X3120- M 2 P7 M -12 V** ordering example ## **Standard voltage ratings and typical internal resistance values** |**voltage rating**|**internal**<br>**internal**<br>**resistance (Ω)**|**voltage rating**|**internal**<br>**internal**<br>**resistance (Ω)**| |---|---|---|---| |DC 12 V|0.78|AC 120 V|71.0| |DC 24 V|3.3|AC 230 V|312| ## **Dimensions** **==> picture [249 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> 10.7 18<br>blade terminals .421 .709<br>DIN 46244-C-Ms-S 21 14<br>(QC 2x.110) .827 .551<br>30 1.18<br>9<br>.354<br>**----- End of picture text -----**<br> ## **Schematic diagram** |m<br>m|12(k)<br>line<br>12(i)<br>22(i)<br>22(k)<br>11<br>21<br>load<br>FA<br>12<br>remote trip<br>12(n)<br>odule<br>ounted| |---|---| ||| |**Technical data**|| ||| |Voltage ratings|AC 120...230 V; DC 12...24 V| |Power consumption|approx. 200 Watt| |Pulse operation|20 ms < tON< 100 ms / tOFF> 10 sec| |Trip time|< 20 ms| |Typical life<br>Ambient temperature|50,000 operations at UN<br>-30…60 °C| |**Dielectric strength**<br>between main<br>and trip current circuit<br>test voltage AC 3,000 V|| |Insulation resistance<br>> 100 MOhm (DC 500 V)|| |Vibration<br>8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)<br>test to IEC 60068-2-6, test Fc<br>10 frequency cycles/axis|| |Shock<br>30 g (11 ms)<br>test to IEC 60068-2-27, test Ea|| |Corrosion<br>96 hours at 5 % salt mist,<br>test to IEC 60068-2-11, test Ka|| |Humidity<br>240 hrs in 95 % RH<br>test to IEC 60068-2-78,<br>test Cab|| |Mass<br>approx. 53 g (including base unit)|| All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. **www.e-t-a.de** 16 1806
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →